Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load coordination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Reinforcement Learning to Enhance Optimal Operation of Resilient Community Energy Systems

This paper presents a novel model-free multi-agent Reinforcement Learning (RL) control method to enhance the resilience of community energy systems in island mode, which coordinates multiple objectives without the necessity of identifying system models that require expert knowledge. Specifically, a community-level coordinator agent is designed to allocate renewable energy resources among different buildings, and multiple building-level agents are developed to optimize load schedules based on limited energy resources and requirements of building loads and occupants’ comfort. In a two-day evaluation, our RL approach demonstrated a similar performance against MPC without requiring system models and formulation of optimization problems as required in MPC.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Flexible Grid Interconnections

Key Considerations: - Long-term coordination and collaboration with utilities and ISOs may provide mutual benefits and support flexible interconnectivity. - Onsite storage and energy production can reduce load fluctuations and support grid resilience in the future. - Geography and resource availability can impact energy demand and grid flexibility.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

A Coordinated-Anion-Enriched Electrolyte for Lean-Electrolyte Li–S Batteries

The solid electrolyte interphase (SEI) on Li and cathode electrolyte interphase (CEI) at sulfurized polyacrylonitrile (SPAN) formed in the commonly used liquid electrolytes cannot accommodate the large volume change of both Li anode and SPAN cathode, resulting in severe electrolyte and Li consumption and fast capacity decay under high mass loading and lean electrolyte condition. Herein, a LiF-rich SEI and a LiF-Li x N y O z co-enriched CEI are simultaneously formed by adding ionic liquid (Py 13 TFSI) in the localized high-concentration electrolyte (LHCE), which forms a coordinated-anion-enriched solvation structure. In this study, the LiF-rich interphase results in less stress/strain during large volume changes of Li and SPAN and therefore achieving obviously improved stability even at a high areal capacity. Consequently, Li (50 μm)||SPAN (6 mg cm -2 ) pouch cells under the lean electrolyte condition (E/S ratio of 5 mL g SPAN -1 ) delivers a stable cycle life of 120 cycles with 79.2% capacity retention, demonstrating great promise for high-energy-density lithium-sulfur batteries.

25 ENERGY STORAGE↗

Understanding the Origin of Negative Temperature Dependence and Activity of N-Coordinated Cobalt Sites During Ethylene Dimerization

The on-demand production of short-chain linear alpha olefins (LAOs; C4-C8) via C2H4 dimerization and oligomerization is industrially attractive, prompting extensive research on designing active, selective, and stable catalysts for industrial use. Cobalt supported on ammoniated carbon (Co(NH3)x/C) catalysts have shown remarkable activity and selectivity in this process. However, critical aspects such as the active phase, active site structure, the role of the catalyst support, cobalt loading effects, and the inverse correlation of the reaction rate with temperature remain inadequately understood. This study systematically explores these factors using a combination of steady-state differential catalytic tests, in situ molecular characterization including diffuse reflectance UV-Vis (DR-UV-Vis), Infrared, and Raman spectroscopies, and ex situ X-ray diffraction (XRD) and high annular aberration-corrected dark field transmission electron microscopy (HAADF-STEM). Various supports (SiO2, Al2O3, NH4-ZSM-5, g-C3N4, and C) and cobalt loadings (1.0-3.0 Co nm-2) were studied to determine the optimal catalyst composition and identify the active phase and sites. Carbon-supported catalysts uniquely produce C4-8 LAOs during C2H4 dimerization, with site-time-yield remaining constant (~10-3 s-1) for 1.0-4.0 Co nm-2 at prolonged reaction times (24-48?h time-on-stream). At higher loadings of 6.0 Co nm-2, the formation of crystalline CoO and Co3O4 phases reduces catalytic activity and LAO selectivity. Our findings show that active catalysts lack crystalline cobalt oxides and instead feature dispersed Co2+ sites, tetra-coordinated to a mix of N/NH3 and O/H2O ligands, which catalyze C2H4 dimerization via the Cossee-Arlman mechanism, exhibiting 1st order dependence on C2H4 concentration. The observed inverse rate-temperature correlation is attributed to compensation effects (i.e., presence of Cremer-Constable relationship) linked to changes in adsorption enthalpic and entropic factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model-Free Control of Grid-Interactive Efficient Buildings Under Communication Time Delays

Grid-interactive efficient buildings (GEBs) have recently been used to enhance the reliability and stability of the electric grid through demand response (DR) programs. However, most existing DR control strategies require accurate modeling of the various building thermostatically controlled loads (TCLs) and are computationally expensive. To address these challenges, a model-free control (MFC)-based strategy has recently been introduced for coordinating and controlling GEBs. MFC is a data-enabled control strategy that is computationally efficient and does not require the analytical models of the various building equipment. In this paper, we numerically investigate the impact of communication time delays on the performance of MFC in maintaining the TCLs' temperatures within the desired comfort levels while meeting the assigned power allocation constraint.

Telsang, Bhagyashri [University of Tennessee, Knox↗

FLYING SERVING: On-the-Fly Parallelism Switching for Large Language Model Serving

Production LLM serving must simultaneously deliver high throughput, low latency, and sufficient context capacity under non-stationary traffic and mixed request requirements. Data parallelism (DP) maximizes throughput by running independent replicas, while tensor parallelism (TP) reduces per-request latency and pools memory for long-context inference. However, existing serving stacks typically commit to a static parallelism configuration at deployment; adapting to bursts, priorities, or long-context requests is often disruptive and slow. We present Flying Serving, a vLLM-based system that enables online DP-TP switching without restarting engine workers. Flying Serving makes reconfiguration practical by virtualizing the state that would otherwise force data movement: (i) a zero-copy Model Weights Manager that exposes TP shard views on demand, (ii) a KV Cache Adaptor that preserves request KV state across DP/TP layouts, (iii) an eagerly initialized Communicator Pool to amortize collective setup, and (iv) a deadlock-free scheduler that coordinates safe transitions under execution skew. Across three popular LLMs and realistic serving scenarios, Flying Serving improves performance by up to 4.79 × under high load and 3.47 × under low load while supporting latency- and memory-driven requests.

Gao, Shouwei [ORNL]↗

Best Practices for Resilience in Smart Grid-Interactive Efficient Buildings

The Federal Energy Management Program (FEMP) supports federal agencies' energy decisions with information and guidance on design, funding, and operations to ensure federal buildings are efficient and resilient. The modernization of building infrastructure and the evolution of buildings to support decarbonization involves complex implementation of multiple components across several systems. This includes energy-efficient equipment, on-site energy generation and storage systems, and control systems. These systems have operational modes that can operate more efficiently if they are able to behave responsively to the conditions of the electrical grid. These grid-interactive efficient buildings (GEB) allow facilities to manage power demand according to operational constraints and market signals issued by grid operators. With proper design and planning, these same capabilities have the potential to enable building and facility resilience - coordinating with microgrids, maintaining power on critical circuits to sustain essential operations, and monitoring building health and safety status during an outage. By managing the load of buildings, GEBs can also reduce the cost of backup generation and make better use of renewable power sources on site. This document outlines some of the processes and considerations to guide the design and operation of GEBs in ways that promote facility resilience.

building decarbonization↗

Q-IRIS: The Evolution of the IRIS Task-Based Runtime to Enable Classical-Quantum Workflows

Extreme heterogeneity in emerging HPC systems are starting to include quantum accelerators, motivating runtimes that can coordinate between classical and quantum workloads. We present a proof-of-concept hybrid execution framework integrating the IRIS asynchronous task-based runtime with the XACC quantum programming framework via the Quantum Intermediate Representation Execution Engine (QIR-EE). IRIS orchestrates multiple programs written in the quantum intermediate representation (QIR) across heterogeneous backends (including multiple quantum simulators), enabling concurrent execution of classical and quantum tasks. Although not a performance study, we report measurable outcomes through the successful asynchronous scheduling and execution of multiple quantum workloads. To illustrate practical runtime implications, we decompose a four-qubit circuit into smaller subcircuits through a process known as quantum circuit cutting, reducing per-task quantum simulation load and demonstrating how task granularity can improve simulator throughput and reduce queueing behavior -- effects directly relevant to early quantum hardware environments. We conclude by outlining key challenges for scaling hybrid runtimes, including coordinated scheduling, classical-quantum interaction management, and support for diverse backend resources in heterogeneous systems.

Miniskar, Narasinga Rao [ORNL] (ORCID:000000018259↗

Theoretical modeling of a bottom-raised oscillating surge wave energy converter structural loadings and power performances

Here, this study presents theoretical formulations to evaluate the fundamental parameters and performance characteristics of a bottom-raised oscillating surge wave energy converter (OSWEC) device. Employing a flat plate assumption and potential flow formulation in elliptical coordinates, closed-form equations for the added mass, radiation damping, and excitation forces/torques in the relevant pitch-pitch and surge-pitch directions of motion are developed and used to calculate the system's response amplitude operator and the forces and moments acting on the foundation. The model is benchmarked against numerical simulations using WAMIT and WEC-Sim, showcasing excellent agreement. The sensitivity of plate thickness on the analytical hydrodynamic solutions is investigated over several thickness-to-width ratios ranging from 1:80 to 1:10. The results show that as the thickness of the benchmark OSWEC increases, the deviation of the analytical hydrodynamic coefficients from the numerical solutions grows from 3% to 25%. Differences in the excitation forces and torques, however, are contained within 12%. While the flat plate assumption is a limitation of the proposed analytical model, the error is within a reasonable margin for use in the design space exploration phase before a higher-fidelity (and thus more computationally expensive) model is employed. A parametric study demonstrates the ability of the analytical model to quickly sweep over a domain of OSWEC dimensions, illustrating the analytical model's utility in the early phases of design.

13 HYDRO ENERGY↗

Deciphering the Dynamic Balance Between Solvation Strength and Polysulfides Reaction Heterogeneity in Practical Lithium‐Sulfur Batteries

Achieving stable interfacial chemistry in lithium–sulfur batteries under practical conditions remains a key barrier to commercialization. Here, we demonstrate that interfacial dynamics can be effectively regulated by coupling solvation-power control with intrinsic heterogeneity of sulfur redox chemistry through the introduction of a weakly solvating fluorinated cosolvent, LIB 1200ET (1200ET). Compared with conventional fluorinated ethers, 1200ET efficiently shifts Li + solvation environment toward a more non-coordinated configuration at low volume fractions, enabling substantial solvation modulation without significantly impairing sulfur redox kinetics. This solvation transition weakens Li + –solvent interactions while strengthening Li + –anion and Li + –lithium polysulfide (LPS) coordination, suppressing LPS solubility and promoting reconstruction of solid–electrolyte interphase (SEI). Regulated LPS chemistry, together with 1200ET, leads to formation of a S 4+ -rich, LiF-reinforced SEI with enhanced ionic conductivity and mechanical robustness. Spatially resolved sulfur K-edge X-ray absorption spectroscopy on pouch cells reveals pronounced current-density-dependent chemical heterogeneity, distinguishing kinetically dominated and solvation-controlled regions. Under practical conditions (3.7 mg cm −2 sulfur loading, E/S = 6 µL mg −1 ), a single-layer pouch cell delivers 527 mAh g −1 over 200 cycles at C/3, while an Ah-level multilayer pouch cell achieves an energy density of 358 Wh kg −1 . These results establish non-coordinating cosolvent-driven solvation engineering as a scalable strategy for practical Li–S batteries.

36 MATERIALS SCIENCE↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

State Requirements for Electric Distribution System Planning

Utilities have conducted distribution planning since they first began building and operating electricity systems. But filing these plans for regulatory and stakeholder review is a relatively recent phenomenon. This report summarizes legislative and regulatory requirements for regulated electric utilities to file some type of distribution system plan in 20 U.S. jurisdictions. Some plans focus on expedited cost recovery for certain types of distribution system improvements; other plans focus on investments for grid modernization or distributed energy resources. Increasingly, states are adopting requirements for Integrated Distribution Plans. Such plans provide holistic grid investment strategies that address state and local policies and increasing complexity at the grid edge. The report covers the following topics for distribution system plans, highlighting advanced practices: -State goals and objectives -Procedural requirements -Forecasting loads and distributed energy resources -Hosting capacity analysis -Baseline information requirements -Grid modernization strategy -Grid needs assessment -Non-wires solutions -Reliability and resilience analyses -Stakeholder engagement -Equity -Pilots -Coordination with other planning processes The report includes links to legislation; regulatory requirements, proceedings, and orders; and filed utility plans. The U.S. Department of Energy’s Office of Electricity provided funding support.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

A Methodology to Evaluate the Grid Reliability Impact of Oscillations Induced by Large Loads

The rapid growth of hyperscale AI data centers is bringing renewed attention to the reliability risk that sustained forced oscillations pose to bulk power systems, with cyclic computational workloads emerging as a new forcing source. Unlike the broadband, stochastic disturbances from traditional industrial loads such as arc furnaces, AI training and inference facilities can inject large active power swings concentrated at specific frequencies over extended durations - characteristics that existing grid planning practices do not account for. While the North American Electric Reliability Corporation (NERC) has recognized this gap and called for system-level studies of large load interconnections, no standardized methodology exists to screen, simulate, and quantify these risks at the planning stage. This report presents the Risk Assessment Tool for Large Load-induced Events (RATLLE), a Python-based, publicly available script suite developed at the Pacific Northwest National Laboratory to evaluate bulk power system reliability risks from data center-induced oscillations. RATLLE implements a three-module workflow: a screening module that identifies vulnerable interconnection locations and excitable system modes; a simulation module that models cyclic data center load behavior using a commercial positive sequence simulation platform; and an analysis module that computes risk metrics and generates interactive visualization dashboards. The risk metrics, formulated around simulation observables, map oscillation impacts to a three-stage severity scale spanning latent equipment fatigue through imminent cascading failure. The methodology is demonstrated on two Western Electricity Coordinating Council (WECC) system models: a publicly available 240-bus reduced representation and a detailed 2031 Heavy Winter planning case. Case studies illustrate that even modest 50 MW forced oscillations at resonant frequencies can produce wide-area power swings, N-1 security constraint violations, and cascading generator trips through protection actions - outcomes that would not occur under normal operating conditions without oscillations present. The results underscore the need for standardized oscillation impact assessment in large load interconnection studies and provide a reproducible, extensible framework for utilities to adopt or customize within their existing planning workflows.

Biswas, Shuchismita↗

Runaway electron-induced plasma facing component damagein tokamaks

This Roadmap article addresses the critical and multifaceted challenge of plasma facing component (PFC) damage caused by runaway electrons (REs) in tokamaks, a phenomenon that poses a significant threat to the viability and longevity of future fusion reactors such as ITER and DEMO. The dramatically increased RE production expected in future high-current tokamaks makes it very difficult to avoid or mitigate REs in such devices when a plasma discharge terminates abnormally. Preventing damage from the intense localised heat loads they can cause requires a holistic approach that considers plasma, REs and PFC damage. Despite decades of progress in understanding the physics of REs and the thermomechanical response of PFCs separately, their complex interplay remains poorly understood. This document aims to initiate a coordinated, interdisciplinary approach to bridge this gap by reviewing experimental evidence, advancing diagnostic capabilities, and improving modelling tools across different scales, dimensionalities, and fidelities. Key topics include RE beam formation and transport, damage mechanisms in both brittle and metallic PFCs, and observed effects in major facilities such as JET, DIII-D, WEST and EAST. The Roadmap emphasises the urgency of predictive, high-fidelity modelling validated against well-diagnosed controlled experiments, particularly in the light of recent changes in ITER’s wall material strategy and the growing importance of private sector fusion initiatives. Each section of the Roadmap article is written to provide a concise overview of one area of this multidisciplinary subject, with an assessment of the status, a look at current and future challenges, and a brief summary. The ultimate goal of this initiative is to guide future mitigation strategies and design resilient components that can withstand the intense localised loads imposed by REs, thus ensuring the safe and sustainable operation of the next generation of fusion power plants.

Ratynskaia, Svetlana [KTH Royal Inst. of Technolog↗

Determining the Minimum Phase‐to‐Phase Gap Distance for Unconventional Transmission Lines Using Numerical Method

With the increasing demand for power transmission, compact, high surge impedance loading (HSIL) high-voltage transmission lines have emerged as a viable solution due to their reduced land acquisition costs and higher power delivery capability. The compactness of a transmission line depends on effective insulation coordination, particularly in determining the phase-to-phase clearance, which is governed by the critical flashover voltage under switching and lightning overvoltage conditions. Traditional methods for phase-to-phase clearance rely on empirical formulas derived from experimental data, which are convenient for conventional high-voltage lines. However, unconventional HSIL lines require a faster and more adaptable evaluation method, as they involve optimized conductor positioning to reduce right-of-way requirements while enhancing natural power loadability. This study presents a simplified numerical approach to determine the minimum phase-to-phase gap, utilizing arc propagation viability curves, and offers an efficient alternative to conventional empirical methods. The proposed method was successfully applied to a 500 kV conventional line as well as 500 and 735 kV unconventional line designs, demonstrating its capability in accurately assessing insulation requirements. Results reveal that the method can support reduced gap clearances while still maintaining reliability, thereby validating its usefulness in optimizing compact transmission line configurations.

Arafat, Easir [The University of Texas at Dallas, ↗

GridPIQ Reference Data

GridPIQ uses dozens of publicly available datasets to provide context for a user's grid project, as well as defaults for users to choose from. Users can choose to import their own data to better customize their analysis or use GridPIQ-supplied defaults. This allows users to get up and running with an analysis very quickly without having to spend significant time pulling together input data. To run an electric vehicle (EV) smart charging project, a user will need to provide or select from prepopulated values for the regional load profile shape and peak load, region of interest and closest weather station, EV charging profile, number of EVs to add for the analysis, maximum EV charging power, location of chargers relative to grid infrastructure, and allowable charging times (for coordinated charging mode). The outputs of the analysis are changes in air quality, EV energy consumption, EV peak demand, and EV hourly consumption profile—before and after project implementation." For a detailed description of the tool methodology, including all the publicly available datasets used by the tool, see the [GridPIQ documentation](https://gridpiq.pnnl.gov/v2-beta/doc/).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Getting brighter: Impacts of improved day-ahead solar forecasts in high-solar, high-storage electricity systems

This paper analyzes the impacts of improved day-ahead solar forecasts on costs and dispatch in the solar-rich Southeast U.S. It uses an optimized high-solar, high-storage resource portfolio in which solar generation capacity accounts for 45 % of total installed capacity (34 %–36 % of generation) and energy storage capacity (43 GW) is equivalent to 33 % of peak demand. In a base scenario, improved day-ahead solar forecasts reduce production costs by $\$87$ million per year ($\$0.13$ per MWh load, $2023$$). This level of savings is within the range or lower than earlier studies of solar forecast improvements at lower levels of solar generation (<25 % of total generation). In this study, solar expansion was accompanied by two important sources of flexibility for managing solar forecast error: energy storage and day-ahead solar curtailment. Furthermore, the analysis finds that regional coordination complements day-ahead solar forecast improvements while natural gas commitment flexibility is a substitute for forecast improvements, as the improved solar forecast leads to sub-optimal commitment of thermal units. Day-ahead solar forecast improvements reduce reserves required to manage forecast error by 30 %. Fewer reserves to manage large, infrequent solar forecast errors could be an important benefit of improved solar forecasts.

14 SOLAR ENERGY↗