Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linearly polarized target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The strangeness program at GlueX

The GlueX experiment located at Jefferson Lab studies the spectrum of hadrons using photoproduction on a LH2 target in a wide variety of final states. With its detector system capable of measuring neutral and charged final state particles over almost the full solid angle, and very good particle iden- tification capabilities, GlueX can measure many different hadrons containing strangeness. A linearly polarized photon beam allows the measurement of po- larization observables, which contain information about the production mecha- nisms involved in generating strange particles in photoproduction. In addition, GlueX can perform precise cross-section measurements, which help to study the spectrum of strange hadrons. In this presentation, the GlueX experiment is introduced, and recent progress of its strangeness program is discussed. We present recent results on ?0 beam asymmetries, ?(1520) spin-density matrix elements and ongoing studies of the ?(1405) lineshape. We also present our recent progress on measurements of ?? ? and ?(?) photoproduction. Also, future prospects for strangeness measurements at GlueX are discussed.

Pauli, Peter↗

Polarization and Color Filtering Applied to Enhance Photogrammetric Measurements of Reflective Surfaces

Techniques for enhancing photogrammetric measurement of reflective surfaces by reducing noise were developed utilizing principles of light polarization. Signal selectivity with polarized light was also compared to signal selectivity using chromatic filters. Combining principles of linear cross polarization and color selectivity enhanced signal-to-noise ratios by as much as 800 fold. More typical improvements with combining polarization and color selectivity were about 100 fold. We review polarization-based techniques and present experimental results comparing the performance of traditional retroreflective targeting materials, cornercube targets returning depolarized light, and color selectivity.

Wells, Jeffrey M.↗

Microstrip patch antenna panel for large aperture L-band phased array

This paper describes the design and development of a large, lightweight antenna panel for an active phased array operating at L-band. The panel was developed under a JPL program of technology development for space based radar. It utilizes dual-stacked patch elements that are interconnected with corporate feed manifold of striplines. This paper focuses on the electromagnetic design and performance of the radiating elements, with emphasis on scan performance, and also addresses mechanical and thermal aspects of the panel. The element in the array environment has a bandwidth of more than 80MHz centered at 1260MHz and is fed so that it can radiate orthogonal linear polarizations. The envisioned phased array, with a nominal aperture of 50m x 2m, is designed to scan +/-45 degrees in azimuth and +/-20 degrees in elevation. The panel of radiating elements has a mass density of 3.9 kg/m2, which represents approximately 50% of the target 8kg/m2 total panel mass density that includes T/R modules and feed manifolds.

T/R modules↗

Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection

Here, a straightforward in situ detection method for dengue infection was demonstrated through the molecular imprinting of a dengue nonstructural protein 1 (NS1) epitope into an electropolymerized molecularly imprinted polyterthiophene (E-MIP) film sensor. The key enabling step in the sensor fabrication is based on an epitope imprinting strategy, in which short peptide sequences derived from the original target molecules were employed as the main template for detection and analysis. The formation of the E-MIP sensor films was facilitated using cyclic voltammetry (CV) and monitored in situ by electrochemical quartz crystal microbalance (EC-QCM). Surface properties were analyzed using different techniques including atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and polarization modulation-infrared reflection-adsorption (PM-IRRAS). The standard calibration curve (R = 0.9830) was generated for the detection of the epitope, Ac-VHTWTEQYKFQ-NH 2 , with a linear range of 0.2 to 30 μg/mL and detection limit of 0.073 μg/mL. A separate calibration curve (R = 0.9786) was obtained using spiked buffered solutions of dengue NS1 protein, which resulted in a linear range of 0.2 to 10 μg/mL and a detection limit of 0.056 μg/mL. The fabricated E-MIP sensor exhibited long-term stability, high sensitivity, and good selectivity towards the targeted molecules. These results indicated that the formation of the exact and stable cavity imprints in terms of size, shape, and functionalities was successful. In our future work, we aim to use our E-MIP sensors for NS1 detection in real-life samples such as serum and blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of NAVSTAR satellite L band ionospheric calibrations with Faraday rotation measurements

It is pointed out that interplanetary navigation at the Jet Propulsion Laboratory (JPL) is performed by analyzing measurements derived from the radio link between spacecraft and earth and, near the target, onboard optical measurements. For precise navigation, corrections for ionospheric effects must be applied, because the earth's ionosphere degrades the accuracy of the radiometric data. These corrections are based on ionospheric total electron content (TEC) determinations. The determinations are based on the measurement of the Faraday rotation of linearly polarized VHF signals from geostationary satellites. Problems arise in connection with the steadily declining number of satellites which are suitable for Faraday rotation measurements. For this reason, alternate methods of determining ionospheric electron content are being explored. One promising method involves the use of satellites of the NAVSTAR Global Positioning System (GPS). The results of a comparative study regarding this method are encouraging.

Royden, H. N.↗

Electrostatic Design and Characterization of a 200 keV Photogun and Wien Spin Rotator

High-energy nuclear physics experiments at the Jefferson Lab Continuous Electron Beam Accelerator Facility (CEBAF) require high spin-polarization electron beams produced from strained super-lattice GaAs photocathodes activated to negative electron affinity in a high voltage photogun operating at 130 kV dc. A pair of Wien filter spin rotators in the injector provides precise control of the electron beam polarization at the end station target. An upgrade of the CEBAF injector to better support the upcoming Moller experiment requires increasing the electron beam energy to 200 keV, resulting in better transmission through injector apertures and improved photocathode lifetime. In addition, the energy increase is expected to reduce unwanted helicity correlated intensity and position systematics. These requirements led to the design of a shielding electrode described in this work, which minimizes the electric field at the triple-point junction and linearizes the potential along the insulator, thus reducing the risk of field emission induced insulator arcing. The Wien spin rotator design was modified for increasing the electric field from 1.6 to 2.7 MV/m and the magnetic field from 9.1 to 13 mT. The upgrades required detailed modeling in Solidworks, electrostatic simulations using CST, beam dynamics using GPT, device implementation, and in situ high voltage characterization of the world?s first 200 keV polarized photoelectron gun and compatible Wien filter spin rotator.

Palacios-Serrano, Gabriel↗

An Electrochemical Strategy to Synthesize Disilanes and Oligosilanes from Chlorosilanes**

Abstract Silanes are important compounds in industrial and synthetic chemistry. Here, we develop a general approach for the synthesis of disilanes as well as linear and cyclic oligosilanes via the reductive activation of readily available chlorosilanes. The efficient and selective generation of silyl anion intermediates, which are arduous to achieve by other means, allows for the synthesis of various novel oligosilanes by heterocoupling. In particular, this work presents a modular synthesis for a variety of functionalized cyclosilanes, which may give rise to materials with distinct properties from linear silanes but remain challenging synthetic targets. In comparison to the traditional Wurtz coupling, our method features milder conditions and improved chemoselectivity, broadening the functional groups that are compatible in oligosilane preparation. Computational studies support a mechanism whereby differential activation of sterically and electronically distinct chlorosilanes are achieved in an electrochemically driven radical‐polar crossover mechanism.

Guan, Weiyang↗

Measurement of Compton Scattering at MAMI for the Extraction of the Electric and Magnetic Polarizabilities of the Proton

A precise measurement of the differential cross sections dσ/dΩ and the linearly polarized photon beam asymmetry Σ 3 for Compton scattering on the proton below pion threshold has been performed with a tagged photon beam and almost 4π detector at the Mainz Microtron. The incident photons were produced by the recently upgraded Glasgow-Mainz photon tagging facility and impinged on a cryogenic liquid hydrogen target, with the scattered photons detected in the Crystal Ball/TAPS setup. Using the highest statistics Compton scattering data ever measured on the proton along with two effective field theories (both covariant baryon and heavy-baryon) and one fixed-t dispersion relation model, constraining the fits with the Baldin sum rule, we have obtained the proton electric and magnetic polarizabilities with unprecedented precision: α E1 = 10.99 ± 0.16 ± 0.47 ± 0.17 ± 0.34, β M1 = 3.14 ± 0.21 ± 0.24 ± 0.20 ± 0.35; in units of 10 -4 fm 3 where the errors are statistical, systematic, spin polarizability dependent, and model dependent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parameterizing Spectral Surface Reflectance Relationships for the Dark Target Aerosol Algorithm Applied to A Geostationary Imager

Originally developed for the Moderate Resolution Imaging Spectroradiometer (MODIS) in polar, sun-synchronous low-earth orbit (LEO), the Dark Target (DT) aerosol retrieval algorithm relies on the assumption of a Surface Reflectance Parameterization (SRP) over land surfaces. Specifically for vegetated and dark-soiled surfaces, values of surface reflectance in blue and red visible-wavelength bands are assumed to be nearly linearly related to each other and to the value in a shortwave infrared (SWIR) wavelength band. This SRP also includes dependencies on scattering angle and a normalized difference vegetation index computed from two SWIR bands (NDVISWIR). As the DT retrieval algorithm is being ported to new sensors to continue and expand the aerosol data record, we assess whether the MODIS-assumed SRP can be used for these sensors. Here, we specifically assess SRP for the Advanced Baseline Imager (ABI) aboard, the Geostationary Operational Environmental Satellite (GOES)-16/East (ABIE). First, we find that using MODIS-based SRP leads to higher biases and artificial diurnal signatures in aerosol optical depth (AOD)retrievals from ABIE. The primary reason appears to be that geostationary orbit (GEO) encounters an entirely different set of observation geometry than does LEO, primarily with regards to solar angles coupled with fixed view angles. Therefore, we have developed a new SRP for GEO that draws the angular shape of the surface bidirectional reflectance. We also introduce modifications to the parametrization of both red-SWIR and blue-red spectral relationships to include additional information.The revised Red-SWIR SRP includes solar zenith angle, NDVISWIR, and land-type percentage from an ancillary database. The blue-red SRP adds dependencies on the scattering angle and NDVISWIR. The new SRPs improve the AOD retrieval of ABIE in terms of overall less bias and mitigation of the overestimation around local noon. The average bias of DT AOD compared to AERONET AOD shows a reduction from 0.08 to 0.03, while the bias of local solar noon decreases from 0.12 to 0.03.The agreement between DT and AERONET AOD is established through regression slope of 1.06 and y-intercept of 0.01with correlation coefficient is0.74. By using the new SRP, the percentage of data falling within the expected error range (±0.05 + 15%) is notably risen from 54% to 78%.

Mijin Kim↗

An Electrochemical Strategy to Synthesize Disilanes and Oligosilanes from Chlorosilanes**

Silanes are important compounds in industrial and synthetic chemistry. Here, we develop a general approach for the synthesis of disilanes as well as linear and cyclic oligosilanes via the reductive activation of readily available chlorosilanes. The efficient and selective generation of silyl anion intermediates, which are arduous to achieve by other means, allows for the synthesis of various novel oligosilanes by heterocoupling. In particular, this work presents a modular synthesis for a variety of functionalized cyclosilanes, which may give rise to materials with distinct properties from linear silanes but remain challenging synthetic targets. In comparison to the traditional Wurtz coupling, our method features milder conditions and improved chemoselectivity, broadening the functional groups that are compatible in oligosilane preparation. Furthermore, computational studies support a mechanism whereby differential activation of sterically and electronically distinct chlorosilanes are achieved in an electrochemically driven radical-polar crossover mechanism.

36 MATERIALS SCIENCE↗

Predicting Excitation Energies of Twisted Intramolecular Charge-Transfer States with the Time-Dependent Density Functional Theory: Comparison with Experimental Measurements in the Gas Phase and Solvents Ranging from Hexanes to Acetonitrile

Electronically excited states characterized by intramolecular charge transfer play an essential role in many biological processes and optical devices. The ability to make quantitative ab initio predictions of the relative energetics involved is a challenging yet desirable goal, especially for large molecules in solution. In this work, we present a data set of 61 experimental measurements of absorption and emission processes, both in the gas phase and in solvents representing a broad range of polarities, which involve intramolecular charge transfer mediated by a nonzero, "twisted" dihedral angle between one or more donor and acceptor subunits. Among a variety of density functionals investigated within the framework of linear-response theory, the "optimally tuned" LRC-ωPBE functional, which utilizes a system-specific yet nonempirical procedure to specify the range-separation parameter, emerges as the preferred choice. For the entire set of excitation energies, involving changes in dipole moment ranging from 4 to >20 Debye, the mean signed and absolute errors are 0.02 and 0.18 eV, respectively (compared, e.g., to -0.30 and 0.30 for PBE0, 0.44 and 0.47 for LRC-ωPBEh, 0.83 and 0.83 for ωB97X-V). We analyze the performance of polarizable continuum solvation models available in Q-Chem that partition the solvent response into fast and slow time scales, and clear trends emerge when measurements corresponding to the four small 4-(dimethylamino)benzonitrile (DMABN)-like molecules and a charged species are excluded. We make the case that the large errors found only for small molecules in the gas phase and weak solvents cannot be expected to improve via the optimal tuning procedure, which enforces a condition that is exact only in the well-separated donor-acceptor limit, and present empirical evidence implicating the outsized importance for small donor-acceptor systems of relaxation effects that cannot be accounted for by the linear-response time-dependent density functional theory within the adiabatic approximation. Finally, we demonstrate the utility of the optimally tuned density functional approach by targeting the charge-transfer states of a large biomimetic model system for light-harvesting structures in Photosystem II.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Analytical Calibration Approach for the Polarimetric Airborne C Band Radiometer

Passive microwave remote sensing is sensitive to the quantity and distribution of water in soil and vegetation. During summer 2000, the Microwave Geophysics Group a t the University of Michigan conducted the seventh Radiobrighness Energy Balance Experiment (REBEX-7) over a corn canopy in Michigan. Long time series of brightness temperatures, soil moisture and micrometeorology on the plot were taken. This paper addresses the calibration of the NASA GSFC polarimetric airborne C band microwave radiometer (ACMR) that participated in REBEX-7. These passive polarimeters are typically calibrated using an end-to-end approach based upon a standard artificial target or a well-known geophysical target. Analyzing the major internal functional subsystems offers a different perspective. The primary goal of this approach is to provide a transfer function that not only describes the system in its entire5 but also accounts for the contributions of each subsystem toward the final modified Stokes parameters. This approach does not assume that the radiometric system is linear as it does not take polarization isolation for granted, and it also serves as a realistic instrument simulator, a useful tool for future designs. The ACMR architecture can be partitioned into functional subsystems. The characteristics of each subsystem was extensively measured and the estimated parameters were imported into the overall dosed form system model. Inversion of the model yields a calibration for the modeled Stokes parameters with uncertainties of 0.2 K for the V and H polarizations and 2.4 K for the 3rd and 4th parameters. Application to the full Stokes parameters over a senescent cornfield is presented.

Pham, Hanh↗

Radiometric calibration of a polarization-sensitive sensor

The radiometric accuracy of a sensor is adversely affected by scene polarization if its optical system is sensitive to polarization. Tests performed on the reflective bands of the NS001 Thematic Mapper simulator, an aircraft multispectral scanner, show that it is very sensitive to the polarization state of the incoming radiations. For 100 percent linearly polarized light, errors in the measured intensity vary from -40 to +40 percent, depending on the scan angle and spectral band. To estimate polarization-induced errors in the intensity measured at aircraft level, the intensity and polarization of the atmospheric radiances were simulated using a realistic earth-atmosphere radiative transfer model. For the polarization of atmospheric radiances in the solar meridian plane over a vegetated target, intensity errors may range from -10 to + 10 percent. The polarization-induced errors are highest in the shortest NS001 spectral band (0.450-0.525 microns) because of large atmospheric polarizations contributed by Rayleigh particles and small diluting effects caused by the small contributions of weakly polarized radiations coming from aerosols and the surface. Depending on the illumination and view angles, the errors in derived surface reflectance due to the radiance errors can be very large. In particular, for large off-nadir view angles in the forward scattered direction when the sun is low, the relative errors in the derived surface reflectance can be as large as 4 to 5 times the relative error in the radiances. Polarization sensitivity errors cannot be neglected for the shorter wavelengths when the surface reflectance contribution to atmospheric radiances is very small.

Ahmad, Suraiya P.↗

Electrochromatographic separation of proteins

We have developed a modified electrochromatography system which minimizes Joule heating at electric field strengths up to 125 V/cm. A non-linear equilibrium model is described which incorporates electrophoretic mobility, hydrodynamic flow velocity, and an electrically induced concentration polarization at the surface of the stationary phase. This model is able to provide useful estimates of protein retention time and velocity in a column packed with Sephadex gel and subjected to an electric field. A correlation of electrophoretic mobility of peptide and proteins with respect to their charge, molecular mass, and asymmetry enables the selection of solute target molecules for electrochromatographic separations. Good separation of protein mixtures have been obtained.

NASA Discipline Life Support Systems↗

Wave-Front Error Measurements and Alignment of CLASP2 Telescope with a Dual-Band Pass Cold Mirror Coated Primary Mirror

"Chromospheric LAyer Spectro-Polarimeter (CLASP2)" is the next sounding rocket experiment of the "Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)" that succeeded in observing for the first time the linear polarization spectra in the hydrogen Lyman- line (121.6 nm) and is scheduled to be launched in 2019. In CLASP2, we will carry out full Stokes-vector spectropolarimetric observations in the Mg II h & k lines near 280 nm with the spectro-polarimeter (SP), while imaging observations in the Lyman- line will be conducted with the slitjaw optics (SJ). For the wavelength selection of CLASP2, the primary mirror of the telescope uses a new dual-band pass cold mirror coating targeting both at 121.6 nm and 280 nm. Therefore, we have to perform again the alignment of the telescope after the installation of the recoated primary mirror. Before unmounting the primary mirror from the telescope structure, we measured the wave-front error (WFE) of the telescope. The measured WFE map was consistent with what we had before the CLASP flight, clearly indicating that the telescope alignment has been maintained even after the flight. After the re-coated primary mirror was installed the WFE was measured, and coma aberration was found to be larger. Finally, the secondary mirror shim adjustments were carried out based on the WFE measurements. In CLASP2 telescope, we improved a fitting method of WFE map (applying 8th terms circular Zernike polynomial tting instead of 37th terms circular Zernike fitting) and the improved method enables to achieve better performance than CLASP telescope. Indeed, WFE map obtained after the final shim adjustment indicated that the required specification (< 5:5 m RMS spot radius) that is more stringent than CLASP telescope was met.

chromosphere; polarimetry; sounding rocket↗

NASA Tech Briefs, April 2013

Topics covered include: Fully Integrated, Miniature, High-Frequency Flow Probe Utilizing MEMS Leadless SOI Technology; Nanoscale Surface Plasmonics Sensor With Nanofluidic Control; Advanced Dispersed Fringe Sensing Algorithm for Coarse Phasing Segmented Mirror Telescopes; Neural Network Back-Propagation Algorithm for Sensing Hypergols; Bulk Moisture and Salinity Sensor; Change-Based Satellite Monitoring Using Broad Coverage and Targetable Sensing; Circularly Polarized Microwave Antenna Element with Very Low Off-Axis Cross-Polarization; Ultra-Low Heat-Leak, High-Temperature Superconducting Current Leads for Space Applications; Flash Cracking Reactor for Waste Plastic Processing; An Automated Safe-to-Mate (ASTM) Tester; Wireless Chalcogenide Nanoionic-Based Radio-Frequency Switch; Compute Element and Interface Box for the Hazard Detection System; DOT Transmit Module; Composite Aerogel Multifoil Protective Shielding; Li-Ion Electrolytes with Improved Safety and Tolerance to High-Voltage Systems; Polymer-Reinforced, Non-Brittle, Lightweight Cryogenic Insulation; Controlled, Site-Specific Functionalization of Carbon Nanotubes with Diazonium Salts; Regenerable Sorbent for CO2 Removal; Sprayable Aerogel Bead Compositions With High Shear Flow Resistance and High Thermal Insulation Value; Lexan Linear Shaped Charge Holder with Magnets and Backing Plate; Robotic Ankle for Omnidirectional Rock Anchors; Wind, Wave, and Tidal Energy Without Power Conditioning; An Active Heater Control Concept to Meet IXO Type Mirror Module Thermal-Structural Distortion Requirement; Waterless Clothes-Cleaning Machine; Integrated Electrical Wire Insulation Repair System; LVGEMS Time-of-Flight Mass Spectrometry on Satellites; Surface Inspection Tool for Optical Detection of Surface Defects; Per-Pixel, Dual-Counter Scheme for Optical Communications; Certification-Based Process Analysis; Surface Navigation Using Optimized Waypoints and Particle Swarm Optimization; Smart-Divert Powered Descent Guidance to Avoid the Backshell Landing Dispersion Ellipse; Estimating Foreign-Object-Debris Density from Photogrammetry Data; Adaptive Sampling of Spatiotemporal Phenomena with Optimization Criteria; Building a 2.5D Digital Elevation Model From 2D Imagery; Eyes on the Earth 3D; Target Trailing With Safe Navigation for Maritime Autonomous Surface Vehicles; Adams-Based Rover Terramechanics and Mobility Simulator - ARTEMIS; ISTP CDF Skeleton Editor; Uplink Summary Generator (ULSGEN) Version 1.0; Robotics On-Board Trainer (ROBoT); Software Engineering Tools for Scientific Models; Automatic Data Filter Customization Using a Genetic Algorithm; Tracker Toolkit; Towards Efficient Scientific Data Management Using Cloud Storage; On a Formal Tool for Reasoning About Flight Software Cost Analysis; A Nanostructured Composites Thermal Switch Controls Internal and External Short Circuit in Lithium Ion Batteries; Spacecraft Crew Cabin Condensation Control; and Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex.

Source record↗

Calibration Design and Assessment of the Airborne Conical Scanning Millimeterwave Imaging Radiometer (CoSMIR)

The airborne Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) will provide measurements useful for atmospheric studies and satellite calibration and validation (cal/val). Designed to match the tropospheric sounding channels of the Defense Meteorological Satellite Program QMSP) Special Sensor Microwave Imager/Sounder (SSMIS), the CoSMIR consists of four radiometers operating at 50-54 (3 channels - 50.3, 52.8, and 53.6), 91.655 (dual polarization), 150.0, and 193.31 (3 channels 11, 13, and 16.6) GHz. The design of CoSMIR was primarily driven by its intended initial use as an SSMIS cal/val sensor. In particular, three design features were directly affected by this requirement: frequency planning, calibration target design, and the mechanical gimbals. An initial calibration assessment of CoSMIR was performed to determine any needed improvements. We used a combination of laboratory and field measurements to do this. Laboratory measurements included comparisons to a liquid nitrogen standard, IF amplifier and diode linearity tests, LO leakage and reflection testing, and antenna to calibration target coupling tests. Results of these tests will be reported. We also performed a satellite underflight under DM SP F-15 and have compared CoSMIR imagery to SSM/T-2 and SSM/I imagery. Additional information is included in the original extended abstract.

Piepmeier, J. R.↗

Reversible electron spirals by chirped attopulses at zero time delay

A class of linear, spiral phenomena is discovered in the photoelectron momentum distribution when studying photoionization of S -state atoms by a pair of linearly chirped, oppositely circularly polarized attosecond pulses eventually delayed in time by $\tau$. This controllable effect, dubbed. reversible electron spirals because of its energy-dependent sense of rotation, is identified and can be isolated in the absence of time delay for the case of opposite chirp rates. Further, the astrophysical concept of spiral arm pitch angle is borrowed to gain a better insight into the energy dependence of the reversible spiral rotation, to determine the attochirp as well as the binding energy characteristic of an atomic target. Our results indicate potential applications in attochirpmetry and polarimetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗