Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

In situ temperature synthesis and characterization of ferroelectric PZN-4.5PT nanoparticles’ thin films using synchrotron light source

Despite the excellent properties of Pb(Zn 1/3 Nb 2/3 )O 3 -4.5PbTiO 3 (PZN-4.5PT) single crystals, the greatest difficulty for their application on electronic devices is to make them to thin layers related to the difficulty to make them as ceramic materials. In this paper, we use the combined USAXS/SAXS/WAXS instrument at 9ID beamline at APS-ANL for in situ characterization of PZN-4.5PT inorganic perovskite nanoparticles thin films deposited on nanotextured silicon to understand the phase transitions and determine the observed microcrystals' structure. Here, the sample was annealed from ambient to 1000°C. The results revealed structure changes in the nanoparticles' thin films which could be explained by the new phase that can be assigned to the Pb 3 (PO 4 )2-based component. The peak at 31° indicates the presence of the rhombohedral phase perovskites assigned to the nanoparticles. WAXS characterization permitted to identification of many transitions during thermal annealing like dehydration or dihydroxylation of phosphorus gel -OH bonds and internal water.

36 MATERIALS SCIENCE↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Probing turbulence with lasers and coherent light sources

Fluid and plasma turbulence consists of multi-scale interactions where the energy of the large scales is dissipated through a cascade to the smallest scales set by the microphysics. Turbulence and mixing can be detrimental to system performance, such as in inertial confinement fusion (ICF). Our current understanding of turbulence is mostly derived from studies of incompressible flows, where the intermediate-scaled eddies in the “inertial range” bridge the transfer of energy from the large eddies to the dissipative range, and that there is no communication between eddies of disparate scales. Whether a similar cascade process exists for compressible turbulence, however, remains to be seen; experiments have been limited by diagnostics and supersonic flow facilities. This project has focused on the development of techniques to measure the evolution of flows and microphysical transport properties using particle tracking velocimetry. This project has investigated three main areas: (1) particle-tracking experiments with x-ray radiography, (2) shock-particle interactions, (3) quantifying viscous effects on particles in shocked flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Accuracy Angle Generator for Angular Calibrations to Support Optical Metrology Laboratories and Light Source Facilities

The overarching vision for this project was to build the most accurate full-rotation angular positioning system in the Americas, and that goal remains. In labs performing similar work, the environment is typically closer to a clean room than an office space, like we had before the upgrades. We are now positioned to achieve our intended result with our upgraded infrastructure, system hardware, calibration techniques, and software. As detailed below, the combination of the pandemic schedule and technical challenges have set us back, but we will continue on the path toward our vision beyond the end of this Phase 2. It’s too important for us, for industry, and for the nation not to do so.

47 OTHER INSTRUMENTATION↗

Results of an interlaboratory study on the working curve in vat photopolymerization II: Towards a standardized method

The working curve measurement in photopolymer additive manufacturing is a ubiquitous measure of the cure depth of a printing resin as a function of radiant exposure of light. The fit parameters from this measurement (the depth of light penetration D p and the critical exposure E c ) are used to evaluate and report a resin’s printability, optimize processing parameters, and inform print and resin quality control. Despite its widespread use, the working curve lacks a standard measurement method. Here, following up on our paper “Results of an Interlaboratory Study on the Working Curve in Vat Photopolymerization” from last year, an interlaboratory study on the working curve was performed using calibrated, reproducible, bandpass filtered light sources. With these light sources, the variability between labs in measured working curves was dramatically reduced from the initial interlaboratory study. Aggregate data from this experiment produced reliable D p and E c measurements at 385 nm of 39.2 ± 3.7 µm and 12.3 ± 3.0 mJ cm −2 , respectively. At 405 nm the values of D p and E c are 69.3 ± 3.8 µm and 17.9 ± 2.3 mJ cm −2 , respectively. The results are agnostic to the thickness measurement tool utilized by participants, ensuring broad applicability across laboratories. We also tested the generalizability of the proposed method of using a filtered light source by filtering a commercial 405 nm light source and obtaining a working curve in agreement with the aggregate data from the interlaboratory study. This interlaboratory study provides a basis for a documentary standard for the working curve, so that the entire photopolymer additive manufacturing industry can share reproducible and interoperable working curve data.

36 MATERIALS SCIENCE↗

Fast image acquisition system and method using pulsed light illumination and sample scanning to capture optical micrographs with sub-micron features

An optical inspection system for detecting sub-micron features on a sample component. The system may have a controller, a camera responsive to the controller for capturing images, an objective lens able to capture submicron scale features on the sample component, and a pulsed light source. The pulsed light source may be used to generate light pulses. The camera may be controlled to acquire images, using the objective lens, only while the pulsed light source is providing light pulses illuminating a portion of the sample component. Relative movement between the sample component and the objective lens is provided to enable at least one of a desired subportion or an entirety of the sample component to be scanned with the camera.

Yoo, Jae Hyuck↗

High-resolution magnetic field fingerprinting of integrated circuit activity with a quantum diamond microscope

Devices for determining a state of a magnetic field-generating article are provided. In various embodiments, a device comprises: a single crystal diamond having a plurality of NV centers, the single crystal diamond configured to be disposed adjacent to a magnetic field-generating article, and configured to generate a fluorescent signal in response to being illuminated by a light source; a coherent light source configured to generate a light beam directed at the single crystal diamond; a microwave (MW) radiation source configured to irradiate the single crystal diamond with a MW signal; a magnetic field source configured to apply a bias magnetic field to the single crystal diamond; a photosensor configured to collect the fluorescent signal generated by the single crystal diamond; and a computing node operatively coupled to each of the coherent light source, the MW radiation source, the magnetic field source, and the photosensor.

Turner, Matthew James↗

Development of a Superconducting Adaptive Gap Undulator Prototype for NSLS-II

The photon flux and brightness of synchrotron radiation, crucial parameters for any light source, vary significantly depending on the type of source employed. Among the 23 Insertion Device (ID) sources at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL), the 12-year-old 3m-long In-Vacuum Undulator (IVU20) stands out for its superior performance, although it no longer represents the cutting edge of technology. Recently, there has been a shift in focus towards developing next-generation sources, particularly Superconducting Undulators (SCUs), characterized by smaller gaps, shorter periods, and maximum lengths. However, despite ongoing research and development efforts, SCUs have yet to surpass their predecessors, the Cryogenic Permanent Magnet Undulators (CPMUs), in terms of performance. This is largely attributed to the limitations posed by traditional superconducting wire, as well as challenges in the design of the magnetic structure and vacuum chamber. In this paper, we aim to overcome such limitations through the development of a unique prototype Superconducting Adaptive Gap Undulator (SC-AGU) magnet core and vacuum chamber design. This paper will outline a novel technical approach aimed at constructing a compact prototype magnet array utilizing state-of-the-art superconducting wire technology. This approach provides a more efficient magnetic structure, allowing for enhanced magnetic field strength and stability.

36 MATERIALS SCIENCE↗

Non-destructive, in-situ evaluation of water presence using thermal contrast and cooled detector

Exemplary methods for detecting presence of water in a sample include: heating a light source to a predetermined temperature at which the light source emits thermal radiation; placing a sample between the light source and a detector; transmitting the thermal radiation from the light source through the sample and onto the detector; and determining a presence or an absence of water within the sample based on the thermal radiation transmitted onto the detector. Exemplary systems for detecting presence of water in a sample are also disclosed.

Bora, Mihail↗