Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LiF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effect of oxide impurities on the corrosion behavior of structural materials in molten LiF-NaF-KF

The corrosion of materials in molten fluoride salts is largely influenced by the presence of impurities in the salt. Very few studies have been done on the effect of oxide impurities on the corrosion of structural alloys in molten fluoride salts. In this study, corrosion behavior of selected alloys was studied in molten FLiNaK with the addition of different oxides such as Li 2 O, NiO, and Cr 2 O 3 . The results show that addition of oxides can lead to significant effects on this corrosion, depending on the type and amount of oxide added and the alloy being used.

14 SOLAR ENERGY↗

Effect of metal fluorides on the corrosion of structural materials in molten LiF-NaF-KF

The corrosion of structural materials in molten fluoride salts is predominantly caused by the presence of impurities in the salt. Here, this study focuses on understanding the corrosion behavior of selected alloys in molten FLiNaK salt with addition of similar quantities of metal fluoride impurities such as CrF 2 , CrF 3 , FeF 2 , FeF 3 , and NiF 2 . The results show that the presence of selected metal fluoride impurities increases the extent of corrosion of the selected alloys in molten FLiNaK salt, with the exact effect depending on the thermodynamic stability of the fluoride impurity added as well as the composition of the structural alloy studied.

36 MATERIALS SCIENCE↗

Hexamethyldisiloxane pyrolysis: probing H-atom initiation by femtosecond two-photon LIF

Previous experiments have led to the hypothesis that pyrolysis of silica nanoparticle precursors carried in an inert central gas jet surrounded by a laminar flame is initiated not by thermal decomposition (the measured jet temperatures are too low for pyrolysis), but by reactions with H-atoms diffusing from the surrounding flame into the jet. The current work tests this hypothesis using femtosecond two-photon laser-induced fluorescence (fs-TPLIF) to image H-atom concentrations in the same flame configuration as the previous experiments. Methane flames (ϕ = 0.83, 1.01 and 1.13) were generated using a multi-element diffusion (Hencken) burner equipped with a central tube through which the N2 jet was introduced. The fs-TPLIF line imaging showed significant concentrations of H-atoms in the nitrogen jets at heights above the burner (HAB) close to the methane flame front. The measurements indicate radial diffusion of the H atoms from the flame to the jet is significant. The H-atom concentrations in the jet increased with increasing stoichiometry of the methane flame. Additional experiments were performed with hexamethyldisiloxane entrained in the central jet flow. In each case, a diffusion flame producing silica nanoparticles was established at the boundaries between the central jet and the methane flames. The 2D H-atom images showed a transition from over-ventilated diffusion flames to under-ventilated diffusion flames with increasing equivalence ratio. Furthermore, the fs-TPLIF profiles show a significant production of H-atoms within the jet when the surrounding flame is lean. This knowledge contributes to a deeper understanding of the underlying mechanisms governing these synthesis flame systems and opens avenues for advancing silica nanoparticle synthesis techniques.

Kim, Keunsoo↗

Corrosion of 316H Stainless Steel Specimens in Two FLiBe (LiF-BeF 2 ) Salt Batches

This milestone was originally envisioned for completion in FY21 and was delayed due to the COVID-19 response and difficulties in fabricating fluoride salts. To complete the milestone, commercial FLiBe was compared to a batch of FLiBe produced by the conventional hydrofluorination process. However, the batch was stopped early due to an HF leak and the salt did not undergo the final H2 sparging. Subsequent static compatibility testing of 316H specimens in 316H capsules resulted in small mass losses for the commercial FLiBe and much larger mass losses for the 2nd batch of FLiBe.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Corrosion of 316H Stainless Steel in Flowing FLiBe (LiF-BeF 2 )

This milestone was originally envisioned for completion in FY21 and was delayed due to the COVID-19 response and difficulties in fabricating/obtaining fluoride salts. A monometallic type 316H stainless steel thermal convection loop (TCL) was operated for 1000 h with flowing LiFBeF 2 (i.e. FLiBe) salt and a peak temperature of 650°C. In general, the attack was minimal. However, classic mass transfer was not clearly observed with mass losses in both the hot and cold legs. There was an issue with cleaning the loop with water and specimens may have oxidized, which was not an issue with the previous FLiNaK TCL.

36 MATERIALS SCIENCE↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing the roles of the solid–electrolyte interphase in designing stable, fast-charging, low-temperature Li-ion batteries

Designing the solid–electrolyte interphase (SEI) is critical for stable, fast-charging, low-temperature Li-ion batteries. Fostering a “fluorinated interphase,” SEI enriched with LiF, has become a popular design strategy. Although LiF possesses low Li-ion conductivity, many studies have reported favorable battery performance with fluorinated SEIs. Such a contradiction suggests that optimizing SEI must extend beyond chemical composition design to consider spatial distributions of different chemical species. In this work, we demonstrate that the impact of a fluorinated SEI on battery performance should be evaluated on a case-by-case basis. Sufficiently passivating the anode surface without impeding Li-ion transport is key. We reveal that a fluorinated SEI containing excessive and dense LiF severely impedes Li-ion transport. In contrast, a fluorinated SEI with well-dispersed LiF (i.e., small LiF aggregates well mixed with other SEI components) is advantageous, presumably due to the enhanced Li-ion transport across heterointerfaces between LiF and other SEI components. An electrolyte, 1 M LiPF 6 in 2-methyl tetrahydrofuran (2MeTHF), yields a fluorinated SEI with dispersed LiF. This electrolyte allows anodes of graphite, μSi/graphite composite, and pure Si to all deliver a stable Coulombic efficiency of 99.9% and excellent rate capability at low temperatures. Pouch cells containing layered cathodes also demonstrate impressive cycling stability over 1,000 cycles and exceptional rate capability down to −20 °C. Through experiments and theoretical modeling, we have identified a balanced SEI-based approach that achieves stable, fast-charging, low-temperature Li-ion batteries.

25 ENERGY STORAGE↗

A confocal laser-induced fluorescence diagnostic with an annular laser beam

Here, in this work, we report an annular beam confocal laser-induced fluorescence (LIF) configuration, which allows for high spatial resolution measurements of plasma properties in plasma setups and sources with limited optical access. The proposed LIF configuration utilizes the annular laser beam generated by a pair of diffractive axicons. The LIF signal is collected along the main optical axis within the ring region. It is shown experimentally that at a focal distance of 300 mm, a spatial resolution of ~5.3 mm can be achieved. Using geometric optics estimations, we showed that ~1 mm resolution at the same focal distance could potentially be achieved by modifying laser beam parameters. This approaches the localization accuracy of conventional LIF collection methods (with crossing laser beam injection and fluorescence collection optical paths). Measurements of the ion velocity distribution function in an argon plasma using both the confocal LIF with an annular laser beam and conventional LIF demonstrate a satisfactory agreement. The proposed LIF setup has potential applications for diagnostics in various plasma processing equipment and plasma sources, such as hollow cathodes, microplasmas, electric propulsion, etc.

47 OTHER INSTRUMENTATION↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

Shock-induced melting of [100] lithium fluoride: Sound speed and Hugoniot measurements to 230 GPa

Although [100] lithium flouride (LiF) is the most widely used optical window material in dynamic compression experiments, its high stress (>100 GPa) shock compression response, including melting, is not well understood. To address this need, we measured wave profiles in plate impact experiments to determine the Hugoniot states and longitudinal sound speeds in [100] LiF crystals shock compressed to 231 GPa. The measured peak states are fitted well by a linear shock velocity-particle velocity relation, providing an accurate determination of the LiF Hugoniot curve to significantly higher stresses than previous experiments. The longitudinal sound speeds show a near linear increase with density compression to 182 GPa. Between 182 GPa and 195 GPa, the sound speed and the longitudinal modulus decrease abruptly, due to shock-induced melting. The increasing sound speeds and moduli at higher stresses suggest that shock compressed LiF is fully liquid at 195 GPa and above, allowing determination of the Gruneisen parameter for liquid LiF. Here, the melt stress determined here differs from that predicted by current multiphase equations of state for LiF. Our results provide important insight into the high stress solid and liquid states of shock compressed LiF and point to the need for an improved multiphase equation of state at high pressures and high temperatures.

36 MATERIALS SCIENCE↗