Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Large Aperture Array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Novel Battery Management System with Distributed Wireless and Fiber Optic Sensors for Early Detection and Suppression of Thermal Runaway in Large Battery Packs, FY13 Q4 Report, ARPA-E Program: Advanced Management Protection of Energy Storage Devices (AMPE

Technology has been developed that enables monitoring of individual cells in highcapacity lithium-ion battery packs, with a distributed array of wireless Bluetooth 4.0 tags and sensors, and without proliferation of extensive wiring harnesses. Given the safety challenges facing lithium-ion batteries in electric vehicle, civilian aviation and defense applications, these wireless sensors may be particularly important to these emerging markets. These wireless sensors will enhance the performance, reliability and safety of such energy storage systems. Specific accomplishments to date include, but are not limited to: (1) the development of wireless tags using Bluetooth 4.0 standard to monitor a large array of sensors in battery pack; (2) sensor suites enabling the simultaneous monitoring of cell voltage, cell current, cell temperature, and package strain, indicative of swelling and increased internal pressure, (3) small receivers compatible with USB ports on portable computers; (4) software drivers and logging software; (5) a 7S2P battery simulator, enabling the safe development of wireless BMS hardware in the laboratory; (6) demonstrated data transmission out of metal enclosures, including battery box, with small variable aperture opening; (7) test data demonstrating the accurate and reliable operation of sensors, with transmission of terminal voltage, cell temperature and package strain at distances up to 110 feet; (8) quantification of the data transmission error as a function of distance, in both indoor and outdoor operation; (9) electromagnetic interference testing during operation with live, high-capacity battery management system at Yardney Technical Products; (10) demonstrated operation with live high-capacity lithium-ion battery pack during charge-discharge cycling; (11) development of special polymer-gel lithium-ion batteries with embedded temperature sensors, capable of measuring the core temperature of individual of the cells during charge-discharge cycling at various temperatures, thereby enabling earlier warning of thermal runaway than possible with external sensors. Ultimately, the team plans to extend this work to include: (12) flexible wireless controllers, also using Bluetooth 4.0 standard, essential for balancing large-scale battery packs. LLNL received $925K for this project, and has $191K remaining after accomplishing these objectives.

25 ENERGY STORAGE↗

NORSAR Final Scientific Report Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration

Correlation detection is a relatively new approach in seismology that offers significant advantages in increased sensitivity and event screening over standard energy detection algorithms. The basic concept is that a representative event waveform is used as a template (i.e. matched filter) that is correlated against a continuous, possibly multichannel, data stream to detect new occurrences of that same signal. These algorithms are therefore effective at detecting repeating events, such as explosions and aftershocks at a specific location. This final report summarizes the results of a three-year cooperative project undertaken by NORSAR and Lawrence Livermore National Laboratory. The overall objective has been to develop and test a new advanced, automatic approach to seismic detection using waveform correlation. The principal goal is to develop an adaptive processing algorithm. By this we mean that the detector is initiated using a basic set of reference ('master') events to be used in the correlation process, and then an automatic algorithm is applied successively to provide improved performance by extending the set of master events selectively and strategically. These additional master events are generated by an independent, conventional detection system. A periodic analyst review will then be applied to verify the performance and, if necessary, adjust and consolidate the master event set. A primary focus of this project has been the application of waveform correlation techniques to seismic arrays. The basic procedure is to perform correlation on the individual channels, and then stack the correlation traces using zero-delay beam forming. Array methods such as frequency-wavenumber analysis can be applied to this set of correlation traces to help guarantee the validity of detections and lower the detection threshold. In principle, the deployment of correlation detectors against seismically active regions could involve very large numbers of very specific detectors. To meet this challenge, we have examined two strategies: (1) use of subspace detectors, a multi-dimensional extension of correlators, which allow representation and detection of signals exhibiting some degree of variation; and (2) autonomous calibration of many subspace and correlation detectors in an adaptive detection framework, subject to analyst review. Because correlation detectors are relatively new to seismology, a significant amount of research on how to tune these detectors has been needed to address later calibration efforts that will arise as they are adopted for operational use. We have approached these challenges by carrying out a number of case studies, encompassing various monitoring scenarios such as earthquake aftershock sequences and swarms, recurring mining explosions, other types of explosions, and rockbursts. We have studied several different geographical regions (the European Arctic, Central Asia, and the western United States). We have drawn on available Ground Truth data in assessing the results of the various processing schemes. In all cases, we have benefited from the high-quality seismic arrays or networks available in these regions, and we have thus been able to evaluate the performance of array-based correlation processing under a variety of conditions. The main results of the project are summarized as follows: (1) Array-based waveform correlation has been demonstrated to lower significantly detection thresholds in comparison with standard single-channel waveform correlation. (2) Frequency-wavenumber analysis of the correlation traces on a small-aperture array provides an effective method for screening out a certain category of false alarms, and can therefore be used to improve detector sensitivity by lowering the threshold for automatic array detection. (3) We have developed and tested a framework for autonomous correlation detection. The framework comprises a set of conventional (STA/LTA) detectors on a collection of array beams, augmented by correlation and subspace detectors. The detectors are applied in parallel. (4) We have experimentally tested the processing of a large aftershock sequence using various transformations of the signals from the main event to construct what we denote an incoherent correlation detector or characteristic function correlation detector. (5) An important application of multi-channel waveform correlation is to identify instances of erroneous instrumental timing. We provide examples of detected timing errors on single channels of an array, as well as on a remote three-component station.

58 GEOSCIENCES↗

Spatial Heterodyne Raman Spectrometer (SHRS) for In Situ Chemical Sensing Using Sapphire and Silica Optical Fiber Raman Probes

A spatial heterodyne Raman spectrometer (SHRS), constructed using a modular optical cage and lens tube system, is described for use with a commercial silica and a custom single-crystal (SC) sapphire fiber Raman probe. The utility of these fiber-coupled SHRS chemical sensors is demonstrated using 532 nm laser excitation for acquiring Raman measurements of solid (sulfur) and liquid (cyclohexane) Raman standards as well as real-world, plastic-bonded explosives (PBX) comprising 1,3,5- triamino- 2,4,6- trinitrobenzene (TATB) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) energetic materials. The SHRS is a fixed grating-based dispersive interferometer equipped with an array detector. Each Raman spectrum was extracted from its corresponding fringe image (i.e., interferogram) using a Fourier transform method. Raman measurements were acquired with the SHRS Littrow wavelength set at the laser excitation wavelength over a spectral range of ∼1750 cm −1 with a spectral resolution of ∼8 cm −1 for sapphire and ∼10 cm −1 for silica fiber probes. The large aperture of the SHRS allows much larger fiber diameters to be used without degrading spectral resolution as demonstrated with the larger sapphire collection fiber diameter (330 μm) compared to the silica fiber (100 μm). Unlike the dual silica fiber Raman probe, the dual sapphire fiber Raman probe did not include filtering at the fiber probe tip nearest the sample. Even so, SC sapphire fiber probe measurements produced less background than silica fibers allowing Raman measurements as close as ∼85 cm −1 to the excitation laser. Despite the short lengths of sapphire fiber used to construct the sapphire probe, well-defined, sharp sapphire Raman bands at 420, 580, and 750 cm −1 were observed in the SHRS spectra of cyclohexane and the highly fluorescent HMX-based PBX. SHRS measurements of the latter produced low background interference in the extracted Raman spectrum because the broad band fluorescence (i.e., a direct current, or DC, component) does not contribute to the interferogram intensity (i.e., the alternating current, or AC, component). SHRS spectral resolution, throughput, and signal-to-noise ratio are also discussed along with the merits of using sapphire Raman bands as internal performance references and as internal wavelength calibration standards in Raman measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High fidelity ultrasound imaging of concrete structures

As plans are made to extend licenses for the aging fleet of commercial nuclear power plants for periods of sixty years and beyond, research into the long-term integrity of their concrete structures has increased. Ultrasound tomography is a useful tool for nondestructive evaluation of these concrete structures. Typically, pulse-echo measurements are made over a large surface and are processed using a reconstruction algorithm, producing a 3D image of the structure that highlights embedded defects. These measurements are processed using a delay-and-sum algorithm such as the synthetic aperture focusing technique (SAFT). Oak Ridge National Laboratory is developing novel ultrasound model-based image reconstruction (U-MBIR) algorithms to improve the imaging capability of pulse-echo ultrasound array imagers. U-MBIR is an inversion technique that reconstructs the sample under test from the ultrasound measurements by formulating and solving a mathematical optimization problem using two sets of terms: one set ensures that the reconstruction matches measured data based on a model for the physics of beam propagation with the noise in the detector, and another set ensures that the reconstruction has certain properties based on a model for the object being scanned. This paper compares three techniques: SAFT, frequency-banded SAFT (FB-SAFT), and U-MBIR. The U-MBIR method produces higher quality images of the underlying concrete structures compared to the images produced using SAFT and FB-SAFT from the same set of measurements. This paper also illustrates the detection of various defects with higher confidence due to the lower noise and artifact-free U-MBIR images.

Ezell, N Dianne↗

Lens and Camera Arrays for Sky Surveys and Space Surveillance

In recent years, a number of sky survey projects have chosen to use arrays of commercia l cameras coupled with commercial photographic lenses to enable low-cost, wide-area observation. Projects such as SuperWASP, FAVOR, Raptor, Lotis, PANOPTES, and Dragonfly rely on multiple cameras with commercial lenses to image wide areas of the sky each night. The sensors are usually commercial astronomical change coupled devices (CCD) or digital single reflex (DSLR) cameras, while the lenses are large-aperture, high-end consumer items intended for general photography. While much of this equipment is very capable and relatively inexpensive, this approach comes with a number of significant limitations that reduce sensitivity and overall utility of the image data. The most frequently encountered limitations include lens vignetting, narrow spectral bandpass, and relatively large point spread function. Understanding these limits helps to assess the utility of the data, and identify areas where advanced optical designs could significantly improve survey performance.

42 ENGINEERING↗

Ultrasonic Flaw Detection of Cracks and Machined Flaws as Observed Through Austenitic Stainless Steel Piping Welds

Piping welds in the pressure boundary of light water reactors (LWRs) are subject to a volumetric examination based on Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code. Due to access limitations and high background radiation levels, the technique used is primarily ultrasonic rather than radiographic. Many of the austenitic welds in safety-related piping systems provide limited access to both sides of the weld, so a far-side examination is necessary. Historically, far-side inspections have performed poorly because of the coarse and elongated grains that make up the microstructures of austenitic weldments. The large grains cause the ultrasound to be scattered, attenuated, and redirected. Additionally, grain boundaries or weld geometry may reflect coherent ultrasonic echoes, making flaw detection and discrimination a more challenging endeavor. Previous studies conducted at the Pacific Northwest National Laboratory (PNNL) on ultrasonic far-side examinations in austenitic piping welds involved the application of conventional transducers, use of low-frequency Synthetic Aperture Focusing Techniques (SAFT), and ultrasonic phased-array (PA) methods on specimens containing implanted thermal fatigue cracks and machined reflectors [1-2]. From these studies, PA inspection provided the best results, detecting nearly all of the flaws from the far side. These results were presented at the Fifth International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurised Components in 2006. This led to an invitation to examine field-removed specimens containing service-induced intergranular stress corrosion cracks (IGSCC) at the Electric Power Research Institute’s (EPRI) Nondestructive Evaluation (NDE) Center, in Charlotte, North Carolina. Results from this activity are presented.

36 MATERIALS SCIENCE↗

Do circumnuclear dense gas disks drive mass accretion onto supermassive black holes?

We present a positive correlation between the mass of dense molecular gas (M{sub dense}) of ∼100 pc scale circumnuclear disks (CNDs) and the black hole mass accretion rate ( M-dot {sub BH}) in a total of 10 Seyfert galaxies, based on data compiled from the literature and an archive (median aperture θ {sub med} = 220 pc). A typical M{sub dense} of CNDs is 10{sup 7–8} M{sub ⊙}, estimated from the luminosity of the dense gas tracer, the HCN(1–0) emission line. Because dense molecular gas is the site of star formation, this correlation is virtually equivalent to the one between the nuclear star-formation rate and M-dot {sub BH} revealed previously. Moreover, the M{sub dense}-- M-dot {sub BH} correlation was tighter for CND-scale gas than for the gas on kiloparsec or larger scales. This indicates that CNDs likely play an important role in fueling black holes, whereas greater than kiloparesec scale gas does not. To demonstrate a possible approach for studying the CND-scale accretion process with the Atacama Large Millimeter/submillimeter Array, we used a mass accretion model where angular momentum loss due to supernova explosions is vital. Based on the model prediction, we suggest that only the partial fraction of the mass accreted from the CND ( M-dot {sub acc}) is consumed as M-dot {sub BH}. However, M-dot {sub acc} agrees well with the total nuclear mass flow rate (i.e., M-dot {sub BH} + outflow rate). Although these results are still tentative with large uncertainties, they support the view that star formation in CNDs can drive mass accretion onto supermassive black holes in Seyfert galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploring cosmic origins with CORE: Survey requirements and mission design

Future observations of cosmic microwave background (CMB) polarisation have the potential to answer some of the most fundamental questions of modern physics and cosmology, including: what physical process gave birth to the Universe we see today? What are the dark matter and dark energy that seem to constitute 95% of the energy density of the Universe? Do we need extensions to the standard model of particle physics and fundamental interactions? Is the ΛCDM cosmological scenario correct, or are we missing an essential piece of the puzzle? In this paper, we list the requirements for a future CMB polarisation survey addressing these scientific objectives, and discuss the design drivers of the COREmfive space mission proposed to ESA in answer to the "M5" call for a medium-sized mission. The rationale and options, and the methodologies used to assess the mission's performance, are of interest to other future CMB mission design studies. COREmfive has 19 frequency channels, distributed over a broad frequency range, spanning the 60–600 GHz interval, to control astrophysical foreground emission. The angular resolution ranges from 2' to 18', and the aggregate CMB sensitivity is about 2 μK∙arcmin. The observations are made with a single integrated focal-plane instrument, consisting of an array of 2100 cryogenically-cooled, linearly-polarised detectors at the focus of a 1.2-m aperture cross-Dragone telescope. The mission is designed to minimise all sources of systematic effects, which must be controlled so that no more than 10 -4 of the intensity leaks into polarisation maps, and no more than about 1% of E-type polarisation leaks into B-type modes. COREmfive observes the sky from a large Lissajous orbit around the Sun-Earth L2 point on an orbit that offers stable observing conditions and avoids contamination from sidelobe pick-up of stray radiation originating from the Sun, Earth, and Moon. The entire sky is observed repeatedly during four years of continuous scanning, with a combination of three rotations of the spacecraft over different timescales. With about 50% of the sky covered every few days, this scan strategy provides the mitigation of systematic effects and the internal redundancy that are needed to convincingly extract the primordial B-mode signal on large angular scales, and check with adequate sensitivity the consistency of the observations in several independent data subsets. COREmfive is designed as a "near-ultimate" CMB polarisation mission which, for optimal complementarity with ground-based observations, will perform the observations that are known to be essential to CMB polarisation science and cannot be obtained by any other means than a dedicated space mission. It will provide well-characterised, highly-redundant multi-frequency observations of polarisation at all the scales where foreground emission and cosmic variance dominate the final uncertainty for obtaining precision CMB science, as well as 2' angular resolution maps of high-frequency foreground emission in the 300–600 GHz frequency range, essential for complementarity with future ground-based observations with large telescopes that can observe the CMB with the same beamsize.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and development of the 3.2 gigapixel camera for the Large Synoptic Survey Telescope

The Large Synoptic Survey Telescope (LSST) is a large aperture, wide-field facility designed to reflect deep images of half the sky every few nights. There is only a single instrument on the telescope, a 9.6 square degree visible-band camera, which is mounted close to the secondary mirror, and points down toward the tertiary. The requirements of the LSST camera present signifcant technical design challenges. To cover the entire 0.35 to 1 μm visible band, the camera incorporates an array of 189 over-depleted bulk silicon CCDs with 10 μm pixels. The CCDs are assembled into 3 x 3 "rafts", which are then mounted to a silicon carbide grid to achieve a total focal plane flatness of 15 μm p-v. The CCDs have 16 amplifiers per chip, enabling the entire 3.2 Gigapixel image to be read out in 2 seconds. Unlike other astronomical cameras, a vast majority of the focal plane electronics are housed in the cryostat, which uses a mixed refrigerant Joule-Thompson system to maintain a -100ºC sensor temperature. The shutter mechanism uses a 3 blade stack design and a hall-effect sensor to achieve high resolution and uniformity. There are 5 filters stored in a carousel around the cryostat and the auto changer requires a dual guide system to control its position due to severe space constraints. This paper presents an overview of the current state of the camera design and development plan.

99 GENERAL AND MISCELLANEOUS↗

CLOUDS TOWARD THE VIRGO CLUSTER PERIPHERY: GAS-RICH OPTICALLY INERT GALAXIES

Aperture synthesis observations of two H I cloud complexes located in the periphery of the Virgo galaxy cluster are presented. These low H I-mass clouds (M{sub H{sub I}}< 10{sup 9} M{sub sun}) are seen projected on the M region of the western Virgo cluster, where the galaxy population is thought to lie behind the main A cluster surrounding M87. The kinematic measurements of both unresolved Arecibo and resolved Very Large Array (VLA)-C observations are in good agreement. The H I detections cannot be identified with any optical, IR, or UV emission from available archival imaging. They are inert at these wavelengths. The H I masses of the individual VLA detections range from 7.28 {<=} log(M{sub H{sub I}}/M{sub sun}){<=} 7.85. The total dynamical mass estimates are several times their H I content, ranging from 7.00 {<=} log(M{sub dyn}/M{sub sun}){<=} 9.07, with the assumption that the clouds are self-gravitating and in dynamical equilibrium. We report the observed parameters derived from the VLA observations. One of these H I clouds appears to be the most isolated optically inert detection observed in the outer reaches of Virgo.

79 ASTRONOMY AND ASTROPHYSICS↗

A Dual-Sided Coded-Aperture Radiation Detection System , Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment

We report the development of a large-area, mobile, coded-aperture radiation imaging system for localizing compact radioactive sources in three dimensions while rejecting distributed background. The 3D Stand-Off Radiation Detection System (SORDS-3D) has been tested at speeds up to 95 km/h and has detected and located sources in the millicurie range at distances of over 100 m. Radiation data are imaged to a geospatially mapped world grid with a nominal 1.25- to 2.5-m pixel pitch at distances out to 120 m on either side of the platform. Source elevation is also extracted. Imaged radiation alarms are superimposed on a side-facing video log that can be played back for direct localization of sources in buildings in urban environments. The system utilizes a 37-element array of 5 x 5 x 50 cm{sup 3} cesium-iodide (sodium) detectors. Scintillation light is collected by a pair of photomultiplier tubes placed at either end of each detector, with the detectors achieving an energy resolution of 6.15% FWHM (662 keV) and a position resolution along their length of 5 cm FWHM. The imaging system generates a dual-sided two-dimensional image allowing users to efficiently survey a large area. Imaged radiation data and raw spectra are forwarded to the RadioNuclide Analysis Kit (RNAK), developed by our collaborators, for isotope ID. An intuitive real-time display aids users in performing searches. Detector calibration is dynamically maintained by monitoring the potassium-40 peak and digitally adjusting individual detector gains. We have recently realized improvements, both in isotope identification and in distinguishing compact sources from background, through the installation of optimal-filter reconstruction kernels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

APERTURE SYNTHESIS IMAGING OF V892 Tau AND PV Cep: DISK EVOLUTION

I present a study of two Herbig Ae stars that are in completely different evolutionary stages: V892 Tau and PV Cep. Using sub-arcsecond interferometric observations obtained with the Combined Array for Research in Millimeter-wave Astronomy at {lambda} = 1.3 and 2.7 mm, I have for the first time resolved their disks. I deduce that the 5 Myr old V892 Tau has a low dust opacity index {beta} = 1.1 and a disk mass of {approx}0.03 M{sub sun}. These values correspond to the growth of its dust into large, up to centimeters size, structures. In contrast, the very young (a few x10{sup 5} yr) PV Cep has a quite high opacity index {beta} = 1.75 and a more massive disk 0.8 M{sub sun}. PV Cep has the youngest resolved disk around any Herbig Ae star. Unlike the youngest T Tauri and Class 0 stars, which contain large and processed grains, the young Herbig Ae star, PV Cep, disk contains interstellar-medium-like unprocessed dust. This suggests that PV Cep's dust evolution is slower than T Tauri stars'. I also present high spatial resolution interferometric observations of the PV Cep outflow. The outflow inclination is consistent with the orientation of the known Herbig-Haro flow in that region, HH315.

79 ASTRONOMY AND ASTROPHYSICS↗

Binary pseudorandom array test standard optimized for characterization of large field-of-view optical interferometers

Recently, a technique for calibrating the modulation transfer function (MTF) of a broad variety of metrology instrumentation has been demonstrated. This technique is based on test samples structured as one-dimensional binary pseudo-random (BPR) sequences and two-dimensional BPR arrays (BPRAs). The inherent power spectral density of BPR gratings (sequences) and arrays has a deterministic white-noise-like character that allows direct determination of the MTF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments directed to the optimization of the sample design, fabrication, application, and data processing procedures, suitable for thorough characterization of large aperture optical interferometers. Compared with the previous coded-aperture based design, the improved, 'highly randomized' BPRA pattern of the new test standard provides better accuracy and reliability of instrument MTF and aberration characterization, and enables operation optimization of large aperture optical interferometers. We describe the pattern generation algorithm and tests to verify the compliance to desired BPRA topography. The data acquisition and analysis procedures for different applications of the technique are also discussed.

Yashchuk, Valeriy V.↗

Mechanical design and vibro-acoustic testing of ultrathin carbon foils for a spacecraft instrument

IBEX-Hi is an electrostatic analyzer spacecraft instrument designed to measure the energy and flux distribution of energetic neutral atoms (ENAs) emanating from the interaction zone between the Earth's solar system and the Milky Way galaxy. A key element to this electro-optic instrument is an array of fourteen carbon foils that are used to ionize the ENAs. The foils are comprised of an ultrathin (50-100 {angstrom} thick) layer of carbon suspended across the surface of an electroformed Nickel wire screen, which in turn is held taught by a metal frame holder. The electro formed orthogonal screen has square wire elements, 12.7 {micro}m thick, with a pitch of 131.1 wires/cm. Each foil holder has an open aperture approximately 5 cm by 2.5 cm. Designing and implementing foil holders with such a large surface area has not been attempted for spaceflight in the past and has proven to be extremely challenging. The delicate carbon foils are subject to fatigue failure from the large acoustic and vibration loads that they will be exposed to during launch of the spacecraft. This paper describes the evolution of the foil holder design from previous space instrument applications to a flight-like IBEX-Hi prototype. Vibro-acoustic qualification tests of the IBEX-Hi prototype instrument and the resulting failure of several foils are summarized. This is followed by a discussion of iterative foil holder design modifications and laser vibrometer modal testing to support future fatigue failure analyses, along with additional acoustic testing of the IBEX-Hi prototype instrument. The results of these design and testing activities are merged and the resulting flight-like foil holder assembly is proposed.

47 OTHER INSTRUMENTATION↗

The Stability of Fiber Spectrographs in the Faint-source Regime

The use of optical fibers in astronomical instrumentation offers high-multiplex and light-gathering flexibility. However, with most previous fiber spectrographs optimized for large fields of view on modest-aperture telescopes, the performance of fibers in the context of faint targets on large telescopes remains largely untested. In this paper, we evaluate aspects of fiber stability, especially as they apply in the context of precision sky subtraction of faint sources at modest spectral resolution ($R$ ~ 3000). After introducing a framework for describing potential systematic errors, we use publicly available data from existing instruments, including instrumentation used by the fourth-generation Sloan Digital Sky Survey’s MaNGA project (MaNGA: Mapping Nearby Galaxies at Apache Point Observatory) and the Very Large Telescope’s FLAMES: Fiber Large Array Multi Element Spectrograph. We isolate sources of fiber systematics and estimate the observed amplitude of persistent residuals as well as stochastic noise contributions resulting from changing fiber stresses. Comparing these levels against their impact on various sky subtraction schemes demonstrates that 0.1% precision sky subtraction with fiber instruments is possible. As a demonstration, we show that the MaNGA instrument can deliver 0.2% residuals on bright near-IR sky lines with nonlocal sky subtraction, if pseudo-slit limitations are addressed by allocating 50% of its fibers to sky. We further highlight recently published deep exposures that achieved a 1$σ$ background level of 27.6 AB per square arc second, equivalent to a precision of 0.2% of the sky background continuum.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining wave-front in different visual angle simultaneously, which provides an approach in building up 3-D model of eye refractor tomographically. Funded by the key Laboratory of High Power Laser and Physics, CAS Research Project of National University of Defense Technology No. JC13-07-01; National Natural Science Foundation of China No. 61205144.

60 APPLIED LIFE SCIENCES↗

An array of virtual Frisch-grid CdZnTe detectors and a front-end application-specific integrated circuit for large-area position-sensitive gamma-ray cameras

We developed a robust and low-cost array of virtual Frisch-grid CdZnTe (CZT) detectors coupled to a front-end readout ASIC for spectroscopy and imaging of gamma rays. The array operates as a self-reliant detector module. It is comprised of 36 close-packed 6x6x15 mm 3 detectors grouped into 3x3 sub-arrays of 2x2 detectors with the common cathodes. The front-end analog ASIC accommodates up to 36 anode and 9 cathode inputs. Several detector modules can be integrated into a single- or multi-layer unit operating as a Compton or a coded-aperture camera. We present the results from testing two fully assembled modules and readout electronics. The further enhancement of the arrays’ performance and reduction of their cost are made possible by using position-sensitive virtual Frisch-grid detectors, which allow for accurate corrections of the response of material non-uniformities caused by crystal defects.

36 MATERIALS SCIENCE↗

5.5 W near-diffraction-limited power from resonant leaky-wave coupled phase-locked arrays of quantum cascade lasers

Five, 8.36 μm-emitting quantum-cascade lasers (QCLs) have been monolithically phase-locked in the in-phase array mode via resonant leaky-wave coupling. The structure is fabricated by etch and regrowth which provides large index steps (Δn = 0.10) between antiguided-array elements and interelement regions. Such high index contrast photonic-crystal (PC) lasers have more than an order of magnitude higher index contrast than PC-distributed feedback lasers previously used for coherent beam combining in QCLs. Absorption loss to metal layers inserted in the interelement regions provides a wide (∼1.0 μm) range in interelement width over which the resonant in-phase mode is strongly favored to lase. Room-temperature, in-phase-mode operation with ∼2.2 kA/cm{sup 2} threshold-current density is obtained from 105 μm-wide aperture devices. The far-field beam pattern has lobewidths 1.65× diffraction limit (D.L.) and 82% of the light in the main lobe, up to 1.8× threshold. Peak pulsed near-D.L. power of 5.5 W is obtained, with 4.5 W emitted in the main lobe. Means of how to increase the device internal efficiency are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗