Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laboratory analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Mathematical analysis of laboratory microbial experiments demonstrating deterministic chaotic dynamics

Presented is a system of four ordinary differential equations and a mathematical analysis of microbiological experiments in a four-component chemostat—nutrient n, rods r, cocci c, and predators p. The analysis is consistent with the conclusion that previous experiments produced features of deterministic chaotic and classical dynamics depending on dilution rate. The surrogate model incorporates as much experimental detail as possible, but necessarily contains unmeasured parameters. The objective is to understand better the differences between model simulations and experimental results in complex microbial populations. The key methodology for simulation of chaotic dynamics, consistent with the measured dilution rate and microbial volume averages, was to cause the preference of p for r vs. c to vary with the r and c concentrations, to make r more competitive for nutrient than c, and to recycle some dying p biomass, leading to a modified version of the Monod kinetics model. Our mathematical model demonstrated that the occurrence of chaotic dynamics requires a predator, p, preference for r versus c to increase significantly with increases in r and c populations. Also included is a discussion of several generalizations of the existing model and a possible involvement of the minimum energy dissipation principle. This principle appears fundamental to thermodynamic systems including living systems. Several new experiments are suggested.

59 BASIC BIOLOGICAL SCIENCES↗

Regulator Interface Strategies Implemented at the Y-12 National Security Complex Old Salvage Yard Soils Remediation Project, Oak Ridge, TN - 12162

The Oak Ridge Y-12 National Security Complex housed an area known as the Old Salvage Yard (OSY) that was approximately 7 acres. The OSY was used as an area for the accumulation, processing and storage of scrap metal and equipment from Y-12 operations extending from 1968 until 2009. Areas in the northern sections of OSY also have been used for the storage of used oils containing solvents and the accumulation and recycling or de-heading and crushing of 55-gal metal drums. Scrap metal operations historically involved the accumulation, sorting, storage, public sale or disposal of scrap metal and equipment. Non-containerised storage of scrap metal was routine until 1995 when scrap metal received at OSY was placed in B-24 and B-25 boxes. Under the American Recovery and Reinvestment Act (ARRA), approximately 26,759 cubic meters of scrap metal and debris were removed and disposed at both on and off-site disposal facilities including the on-site, Oak Ridge Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) landfill in 2010 and 2011. This removal action was performed in accordance with a CERCLA Record of Decision (ROD) and a close working relationship with both the U.S. Environmental Protection Agency (EPA) Region IV and Tennessee Department of Environment and Conservation (TDEC). Due to efficiencies and the excellent cooperative relationship forged with EPA Region IV and TDEC for Y-12 ARRA Cleanup Projects, a surplus of funding was available for additional remediation work that was completed in fiscal year (FY) 2011. The underlying OSY soils were targeted for characterization and potential remediation. To expedite these important activities, the U.S. Department of Energy Oak Ridge Environmental Management partnered with the regulators during detailed planning sessions through a variety of means to quickly and efficiently characterize and pinpoint areas requiring remediation according to previous ROD commitments. Data Quality Objectives (DQOs), data-sharing, real-time characterization reporting, surface and groundwater modeling and other interface planning activities were utilized to help facilitate and complete characterization and remediation activities. As a result of these strategies, the surgical extraction of one contiguous area of soil approximately 354 cubic meters is planned for FY12. The strategies discussed resulted in a major reduction of footprint remediation (i.e., 2.8% of the original estimate) which was originally estimated at over 26,759 cubic meters. The original estimate was developed using historical data collected at various times over the period of 20 years. By leveraging a hybrid sampling approach that involved both statistically-based and biased sampling locations, the area of contamination was significantly reduced resulting in both a compliant remedial design that is cost effective while mitigating a principle threat sources to surface and groundwater at the Y-12 plant. One remedial action boundary of 354 cubic meters was verified in the northern section of the Western OSY area known as the old drum de-header station for VOCs. The original estimate for disposal was in excess of 26,759 cubic meters. This area is scheduled for waste characterization and profile development in the first half of fiscal year 2012. The anticipated disposal facility is an on-site Oak Ridge CERCLA disposal landfill known as the Environmental Management Waste Management Facility (EMWMF). By utilizing the careful strategic planning, field-based screening and close cooperation of regulatory stakeholders as detailed in this paper, the total area of soil requiring remedial action within the Y-12 OSY footprint was 354 cubic meters or 2.8% of the original planned estimate. A potential waste reduction of 97.2% was realized over the original planned estimate for OSY Soils. Significant cost savings were achieved by - Minimizing the footprint of the remedial action; - Confirmatory analysis of soils instead of use of historical sampling results for waste profile development; - Targeting traditional laboratory analysis for soils that failed field screen protocols for radionuclides, heavy metals and VOCs; - Providing accurate and precise definition of RABs; and - Reduction of target contaminants for focused laboratory analysis instead of broad-range contaminants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CXTFIT/Excel A modular adaptable code for parameter estimation, sensitivity analysis and uncertainty analysis for laboratory or field tracer experiments

We implemented the widely used CXTFIT code in Excel to provide flexibility and added sensitivity and uncertainty analysis functions to improve transport parameter estimation and to facilitate model discrimination for multi-tracer experiments on structured soils. Analytical solutions for one-dimensional equilibrium and nonequilibrium convection dispersion equations were coded as VBA functions so that they could be used as ordinary math functions in Excel for forward predictions. Macros with user-friendly interfaces were developed for optimization, sensitivity analysis, uncertainty analysis, error propagation, response surface calculation, and Monte Carlo analysis. As a result, any parameter with transformations (e.g., dimensionless, log-transformed, species-dependent reactions, etc.) could be estimated with uncertainty and sensitivity quantification for multiple tracer data at multiple locations and times. Prior information and observation errors could be incorporated into the weighted nonlinear least squares method with a penalty function. Users are able to change selected parameter values and view the results via embedded graphics, resulting in a flexible tool applicable to modeling transport processes and to teaching students about parameter estimation. The code was verified by comparing to a number of benchmarks with CXTFIT 2.0. It was applied to improve parameter estimation for four typical tracer experiment data sets in the literature using multi-model evaluation and comparison. Additional examples were included to illustrate the flexibilities and advantages of CXTFIT/Excel. The VBA macros were designed for general purpose and could be used for any parameter estimation/model calibration when the forward solution is implemented in Excel. A step-by-step tutorial, example Excel files and the code are provided as supplemental material.

54 ENVIRONMENTAL SCIENCES↗

Automated Laboratory and Field Radionuclide Analysis Systems

Automated laboratory radionuclide analysis systems greatly simplify the human component of processing and can offer greater reproducibility while saving time and effort. Automated field radionuclide analysis systems can provide more timely data reporting than previously available while reducing the costs associated with shipping field samples to a laboratory for analysis. This chapter describes general aspects of automating these systems and presents a number of examples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Idaho National Laboratory’s Analysis of ARRA-Funded Plug-in Electric Vehicle and Charging Infrastructure Projects: Final Report

Battelle Energy Alliance, LLC, managing and operating contractor for the U.S. Department of Energy’s (DOE) Idaho National Laboratory (INL), is the lead laboratory for U.S. Department of Energy’s Advanced Vehicle Testing Activity (AVTA). INL’s conduct of the AVTA resulted in a significant base of knowledge and experience in the area of testing light-duty vehicles that reduced transportation-related petroleum consumption. Due to this experience, INL was tasked by DOE to develop agreements with companies that were the recipients of The American Recovery and Reinvestment Act of 2009 (ARRA) grants, that would allow INL to collect raw data from light-duty vehicles and charging infrastructure. INL developed non-disclosure agreements (NDAs) with several companies and their partners that resulted in INL being able to receive raw data via server-to-server connections from the partner companies. This raw data allowed INL to independently conduct data quality checks, perform analysis, and report publicly to DOE, partners, and stakeholders, how drivers used both new vehicle technologies and the deployed charging infrastructure. The ultimate goal was not the deployment of vehicles and charging infrastructure, cut rather to create real-world laboratories of vehicles, charging infrastructure and drivers that would aid in the design of future electric drive transportation systems. The five projects that INL collected data from and their partners are: • ChargePoint America - Plug-in Electric Vehicle Charging Infrastructure Demonstration • Chrysler Ram PHEV Pickup - Vehicle Demonstration • General Motors Chevrolet Volt - Vehicle Demonstration • The EV Project - Plug-in Electric Vehicle Charging Infrastructure Demonstration • EPRI / Via Motors PHEVs – Vehicle Demonstration The document serves to benchmark the performance science involved the execution, analysis and reporting for the five above projects that provided lessons learned based on driver’s use of the vehicles and recharging decisions made. Data is reported for the use of more than 25,000 vehicles and charging units.

33 ADVANCED PROPULSION SYSTEMS↗

Adsorptive Films in Support of In-field UF6 Destructive Assay Sample Collection and Analysis

International Atom Energy Agency (IAEA) safeguard verification measures in gaseous centrifuge enrichment plants (GCEPs) rely on environmental sampling, non-destructive assay (NDA), and destructive assay (DA) sampling and analysis to determine uranium enrichment. UF6 bias defect measurements are made by DA sampling and analysis to assure that enrichment is consistent with declarations. DA samples are collected from a limited number of cylinders for high precision, offsite mass spectrometer analysis. Samples are typically drawn from a sampling tap into a UF6 sample bottle, then packaged, sealed, and shipped under IAEA chain of custody to an offsite analytical laboratory. Future DA safeguard measures may require improvements in efficiency and effectiveness as GCEP capacities increase and UF6 shipping regulations become increasingly more restrictive. The Pacific Northwest National Laboratory (PNNL) DA sampler concept and Laser Ablation Absorption Ratio Spectrometry (LAARS) assay method are under development to potentially provide DA safeguard tools that increase inspection effectiveness and reduce sample shipping constraints. The PNNL DA sampler concept uses a handheld sampler to collect DA samples for either onsite LAARS assay or offsite laboratory analysis. The DA sampler design will use a small sampling planchet that is coated with an adsorptive film to collect controlled quantities of UF6 gas directly from a cylinder or process sampling tap. Development efforts are currently underway at PNNL to enhance LAARS assay performance to allow high-precision onsite bias defect measurements. In this paper, we report on the experimental investigation to develop adsorptive films for the PNNL DA sampler concept. These films are intended to efficiently capture UF6 and then stabilize the collected DA sample prior to onsite LAARS or offsite laboratory analysis. Several porous material composite films were investigated, including a film designed to maximize the chemical adsorption and binding of gaseous UF6 onto the sampling planchet.

destructive assay↗

Corrective Action Investigation Plan for Corrective Action Unit 371: Johnnie Boy Crater and Pin Stripe Nevada Test Site, Nevada, Revision 0

Corrective Action Unit (CAU) 371 is located in Areas 11 and 18 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 371 is comprised of the two corrective action sites (CASs) listed below: • 11-23-05, Pin Stripe Contamination Area • 18-45-01, U-18j-2 Crater (Johnnie Boy) These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on November 19, 2008, by representatives of the Nevada Division of Environmental Protection; U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 371. Appendix A provides a detailed discussion of the DQO methodology and the DQOs specific to each CAS. The scope of the corrective action investigation for CAU 371 includes the following activities: • Move surface debris and/or materials, as needed, to facilitate sampling. • Conduct radiological surveys. • Measure in situ external dose rates using thermoluminescent dosimeters or other dose measurement devices. • Collect and submit environmental samples for laboratory analysis to determine internal dose rates. • Combine internal and external dose rates to determine whether total dose rates exceed final action levels (FALs). • Collect and submit environmental samples for laboratory analysis to determine whether chemical contaminants are present at concentrations exceeding FALs. • If contamination exceeds FALs, define the extent of the contamination exceeding FALs. • Investigate waste to determine whether potential source material is present. This Corrective Action Investigation Plan has been developed in accordance with the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; U.S. Department of Energy; and U.S. Department of Defense. Under the Federal Facility Agreement and Consent Order, this Corrective Action Investigation Plan will be submitted to the Nevada Division of Environmental Protection for approval. Fieldwork will be conducted following approval of the plan.

54 ENVIRONMENTAL SCIENCES↗

Riverine Plastic Pollution: Sampling and Analysis Methods

Riverine plastic pollution has been found in all major U.S. rivers, but the exact amount of plastic being released to the oceans has not been quantified. Field studies conducted in U.S. rivers have used a range of sampling and analysis techniques and rarely measured the mass of the plastic collected. Measurements of riverine plastic pollution are needed to calibrate and validate models used to estimate the U.S. riverine plastic emissions to the oceans. This report surveys measurement methods used to quantify riverine pollution and current estimates of U.S. riverine plastic pollution from measurements and models. Measurement methods include field sampling and laboratory analysis. Field sampling methods are described for large (macro) and small (micro) plastic particles. Laboratory analysis methods are described for macro and microplastic with an emphasis on the detailed characterization processes of microplastics. Waterborne leachate analysis is also briefly described. Three models are described that estimate plastic pollution based on mismanaged plastic waste in the river catchment basins. The models were validated and calibrated with global data sources. The data sources were predominantly outside of the U.S., where the magnitude and composition of plastic pollution is different than what is found in U.S. rivers. Comprehensive measurements of riverine plastics are needed not only to characterize the riverine plastic pollution, but also parameterize and validate models of plastic fate and transport. This report also describes five key U.S. rivers that span a range of sizes and environmental conditions that could be sampled to obtain data to support characterization and model development of plastic pollution from rivers to oceans. Sampling and analysis protocol recommendations are made to ensure the highest quality of data are collected in the five rivers.

54 ENVIRONMENTAL SCIENCES↗

On the importance of phase saturation heterogeneity in the analysis of laboratory studies of hydrate dissociation

Methane hydrates (MHs) have been considered as the future source of energy because of its vast resource volume and high energy density. Energy recovery from MH-bearing sediments has attracted intensifying research activities. Fundamentally, heat transfer, fluid flow through porous media, and the kinetics of hydrate reaction are the three key processes controlling the behavior of MH dissociation and the associated fluid production. Earlier studies have suggested that heterogeneous spatial distribution of SH is inevitable in MH-bearing samples synthesized in laboratory. In this paper, we extend our study to analyze numerically the simulation results from the two realizations of the samples (homogeneous and heterogeneous) to identify differences in the fluid production and to determine if they are sufficiently different. Additionally, we conduct a sensitivity analysis and a statistical analysis on the key transport and kinetic rate parameters that could affect hydrate dissociation and fluid production in the context of a heterogeneous hydrate-bearing sample, in an effort to provide insights that could lead to improved designs for laboratory experiments and (possibly) field applications. Our results suggest that the approximation of an artificial hydrate-bearing core with heterogeneous phase saturations by an assumption of uniform phase saturation distributions results in practically similar fluid production profile except for the very early stage with maximum 20.0% deviation in the water production. From the sensitivity and statistical analysis, we determine that gas production depends strongly on the kinetic rate constant, K d 0 and the composite thermal conductivity of the hydrate-bearing sediments, λ θ ; while, water production is very sensitive to K d 0 and the absolute permeability of the sandy medium, k. Understanding the effect of phase heterogeneity and the relative importance of key parameters on the production behavior of hydrate-bearing sediments could provide basis for novel production technologies that lead to enhanced gas production and energy efficiency in the energy recovery process.

42 ENGINEERING↗

Corrective Action Investigation Plan for Corrective Action Unit 367: Area 10 Sedan, Ess and Uncle Unit Craters Nevada Test Site, Nevada, Revision 0

Corrective Action Unit 367 is located in Area 10 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 367 comprises the four corrective action sites (CASs) listed below: • 10-45-01, U-10h Crater (Sedan) • 10-45-02, Ess Crater Site • 10-09-03, Mud Pit • 10-45-03, Uncle Crater Site The CASs in CAU 367 are being investigated because hazardous and/or radioactive contaminants may be present in concentrations that exceed risk-based corrective action (RBCA) levels. Existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend CAAs for the CASs. Additional information will be generated by conducting a CAI before evaluating and selecting CAAs. The scope of the corrective action investigation for CAU 367 includes the following activities: • Move surface debris and/or materials, as needed, to facilitate sampling. • Conduct radiological surveys. • Collect and submit environmental samples for laboratory analysis to determine the area where TED at the site exceeds FALs (i.e., corrective action boundary). • Evaluate TED to potential receptors in areas along Mercury Highway that have been impacted by a release of radionuclides from the Sedan test. • Collect and submit environmental samples for laboratory analysis related to the drilling mud within CAS 10-09-03, Mud Pit, and any encountered stains or waste as necessary to determine whether COCs are present. • If COCs are present, collect additional step-out samples to define the extent of the contamination. • Collect samples of investigation-derived waste, as needed, for waste management purposes.

54 ENVIRONMENTAL SCIENCES↗

Sustaining On-going Risk Communication at the Riverton, Wyoming, Processing Site - 20310

An environmental risk assessment report has been completed to provide an updated assessment regarding current site conditions for the Riverton, Wyoming, Processing site. Argonne National Laboratory conducted the assessment in collaboration with the U.S Department of Energy (DOE) Office of Legacy Management (LM) and the Northern Arapaho Natural Resources Office (NANRO). The data quality objectives process conducted confirmed that data from plants growing on the Riverton site would be useful and would address an outstanding concern. Data available from site soil, groundwater, and surface water were also used in the assessment in conjunction with the new plant data. A plant survey was then conducted in 2018 to identify the plants at the Riverton site with known traditional Native American cultural uses for sampling and analysis. Laboratory analysis was conducted on the plant samples for the contaminants of concern. Samples were collected from plants growing on the groundwater plume area of the site, and the same was done for eight other areas not affected by the groundwater plume but still within the institutional control boundary. These eight areas served as reference areas for this study. This human health and ecological assessment update provide the quantitative risk information that was qualitatively addressed in a 1995 Risk Assessment Report on plants, livestock, and surface water exposures at the Riverton site [1]. The conditions at the Riverton site are protective of human health and the environment given the results of the update, in combination with past completed remedial action and ongoing monitoring activities and IC implementation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of renal stone composition by using fast kilovoltage switching dual-energy computed tomography compared to laboratory stone analysis: a pilot study

Purpose: To prospectively examine the diagnostic performance of fast kilovoltage switching dual-energy computed tomography (DECT) in characterization of in vivo renal stone composition compared with postoperative stone analysis. Methods: Consecutive consenting patients scheduled for endoscopic kidney stone surgery in a tertiary referral hospital from June 2015 to January 2016 were enrolled. Patients were preoperatively scanned with single-source, fast kilovoltage switching DECT. Stone compositions were determined regarding the effective atomic number measurements. Results of the stone compositions from DECT were compared to postoperative infrared spectroscopy stone analysis as the standard reference. Results: For the 39 patients enrolled in the study, DECT was able to detect uric acid stone with sensitivity of 88.9% and specificity of 100%. There was 100% positive predictive value, 96.8% negative predictive value, and 97.4% accuracy. For non-contrast CT scan, sensitivity was 88.9%, specificity was 96.7%, positive predictive value was 88.9%, negative predictive value was 96.7%, and accuracy was 94.8%. Of the 39 samples examined, 21 (54%) were single composition, whereas 18 (46%) were combined. Single composition stones were correctly characterized by DECT in 100% (8/8) for uric acid. Whereas the result of uric acid stone containing stone discrimination in mixed composition was not so good with Z{sub eff} alone, iodine imaging can compensated this fault. Conclusions: DECT provides excellent accuracy in characterizing uric acid stone compositions. With the addition of iodine image, all of uric acid-containing stones can be determined by the DECT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Critical review of the Mogi failure criterion based on true-triaxial laboratory data analysis and theoretical considerations

The influence of the intermediate principal stress, σ 2 , is disregarded when rock strength is analyzed using the Mohr-Coulomb or Hoek-Brown criteria. Several polyaxial strength criteria have been proposed to account for the influence of σ 2 . One of the methods that received considerable attention is the Mogi criterion. The criterion modifies the Nadai or Drucker-Prager approaches by exchanging the normal octahedral stress with what is introduced as the mean effective stress, σ m,2 . This change is based on experimental evidence that the influence of the intermediate principal stress on strength is less pronounced than the influence of the minimum principal stress. However, the Mogi criterion was derived somewhat empirically and consequently it is essential to analyze its potential theoretical deficiencies. In the current note, we analyzed the Mogi failure criterion, describing its characteristics in both τ oct –σ m,2 and σ 1 -σ 2 spaces. We investigated the relation between Mohr-Coulomb and Mogi criteria, which marks the basis for the commonly used Mogi-Coulomb approach. Here, we compared the performance of the Mogi criterion against available polyaxial strength data using three fitting approaches: Mogi-Coulomb based on triaxial compression results only, linear Mogi based on all polyaxial strength results, and power law Mogi also based on all data. The analysis reveals several serious deficiencies of the Mogi approach which all suggest that the Mogi criterion cannot properly represent the σ 2 dependence of rock strength in many cases.

58 GEOSCIENCES↗

Analysis of laboratory data on ultrasonic monitoring of permeability reduction due to biopolymer formation in unconsolidated granular media

We show how to estimate the fluid permeability changes due to accumulated biopolymer within the pore space of a granular material using laboratory measurements of overall permeability, together with various well-known quantitative measures (e.g., porosity, specific surface area, and formation factor) of the granular medium microstructure. The main focus of the paper is on mutual validation of existing theory and a synthesis of new experimental results. Here, we find that the theory and data are in good agreement within normal experimental uncertainties. We also establish quantitative empirical relationships between seismic and/or acoustic attenuation and overall permeability for these same systems.

58 GEOSCIENCES↗