Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LITHIUM 10”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Preparation of a high concentration of lithium-7 atoms in a magneto-optical trap

This study is aimed at obtaining high concentration of optically cooled lithium-7 atoms for preparing strongly interacting ultracold plasma and Rydberg matter. A special setup has been constructed, in which two high-power semiconductor lasers are used to cool lithium-7 atoms in a magneto-optical trap. At an optimum detuning of the cooling laser frequency and a magnetic field gradient of 35 G/cm, the concentration of ultracold lithium-7 atoms reaches about 10{sup 11} cm{sup −3}. Additional independent information about the concentration and number of ultracold lithium-7 atoms on different sublevels of the ground state was obtained by using of an additional probing laser.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physico-chemical mechanisms involved in the acceleration of the hydration of calcium sulfoaluminate cement by lithium ions

This work investigates the influence of lithium ions on the hydration at 25 °C of two calcium sulfoaluminate (CSA) cements comprising 0 or 10% gypsum. Small concentrations of lithium salts (LiOH, LiNO{sub 3}) accelerate the early hydration of both CSA cements either in paste or in diluted and stirred suspension. The effect of the lithium cation is much stronger than its counter-ion. Hydration is accelerated by an increase in the lithium concentration up to 30 μmol Li/g of the used CSA cement (with a high ye'elimite content), and then levels off. The postulated mechanism relies on a fast precipitation of amorphous Li-containing Al(OH){sub 3}, which acts as seeds for accelerating the precipitation of amorphous Al(OH){sub 3} that speeds up the whole hydration process. This process seems to be closely related to the one involved in the acceleration of the hydration of calcium aluminate cement by lithium ions.

36 MATERIALS SCIENCE↗

Prediction of neutron production and energy spectrum by the inverse kinematic reaction between an incident 7 Li 3+ beam and a proton target in PHITS

A neutron source using the inverse kinematic reaction between lithium and proton, p( 7 Li, n) 7 Be, achieves forward-directed neutrons, potentially enhancing neutron yield in the forward direction. Despite the advantage, no evaluated-cross-section data for this reaction can be used in Monte Carlo simulation codes, such as PHITS. To solve this problem, this study aims to evaluate the applicability of the user-defined cross-section data, Frag data, for p ( 7 Li, n) 7 Be in PHITS. The simulations reproduced collisions between 7 Li 3+ ions and polypropylene targets. The Frag data was edited based on the JENDL-5 by utilizing the two-body collision kinematics. The neutron yield and angular distribution were investigated in the simulation. As a result, the forward neutron convergence with a reasonable neutron yield and energy spectrum was observed. The expected neutron yield in the forward 1-steradian area is 2.46 × 10 10 n/s when lithium-ion energy and current are 16.45 MeV and 0.1 mA.

43 PARTICLE ACCELERATORS↗

Single crystal structure and SHG of defect pyrochlores CsB{sup V}MoO{sub 6} (B{sup V}=Nb,Ta)

The crystal structure and non-linear optical properties of CsNbMoO{sub 6} and CsTaMoO{sub 6} defect pyrochlores have been studied. The single crystals of these compounds grown by the flux method possess an octahedral faceting and reach up to 50 µm in size. The crystal structures of CsB{sup V}MoO{sub 6} (B{sup V}=Nb, Ta) were investigated by X-ray diffraction method. Both compounds crystallize in the cubic symmetry with noncentrosymmetric space group F-43m. The second harmonic generation of CsNbMoO{sub 6} and CsTaMoO{sub 6}was found to be 1.6×10{sup −2} and 8.5×10{sup −4} of lithium niobate, correspondingly. It has been determined that distortions of [MO{sub 6}] polyhedra (M=Nb, Ta, Mo) as well as polarizability and covalency of Nb–O and Ta–O bonds have a great effect on the second harmonic generation. - Highlights: • CsNbMoO{sub 6} and CsTaMoO{sub 6} homogeneous single crystals have been grown. • The crystal structure of CsTaMoO{sub 6} has been studied. • Nonlinear optical properties of CsNbMoO{sub 6} and CsTaMoO{sub 6} have been found. • The microscopic origin of the second harmonic generation (SHG) response have been identified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculations of stopping powers of 100 eV-30 keV electrons in 31 elemental solids

We present calculated electron stopping powers (SPs) for 31 elemental solids (Li, Be, glassy C, graphite, diamond, Na, Mg, K, Sc, Ti, V, Fe, Y, Zr, Nb, Mo, Ru, Rh, In, Sn, Cs, Gd, Tb, Dy, Hf, Ta, W, Re, Os, Ir, and Bi). These SPs were determined with an algorithm previously used for the calculation of electron inelastic mean free paths and from energy-loss functions (ELFs) derived from experimental optical data. The SP calculations were made for electron energies between 100 eV and 30 keV and supplement our earlier SP calculations for ten additional solids (Al, Si, Cr, Ni, Cu, Ge, Pd, Ag, Pt, and Au). Plots of SP versus atomic number for the group of 41 solids show clear trends. Multiple peaks and shoulders are seen that result from the contributions of valence-electron and various inner-shell excitations. Satisfactory agreement was found between the calculated SPs and values from the relativistic Bethe SP equation with recommended values of the mean excitation energy (MEE) for energies above 10 keV. We determined effective MEEs versus maximum excitation energy from the ELFs for each solid. Plots of effective MEE versus atomic number showed the relative contributions of valence-electron and different core-electron excitations to the MEE. For a maximum excitation energy of 30 keV, our effective MEEs agreed well for Be, graphite, Na, Al, and Si with recommended MEEs; a difference for Li was attributed to sample oxidation in the SP measurements for the recommended MEE. Substantially different effective MEEs were found for the three carbon allotropes (graphite, diamond, and glassy C)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modified predictive formula for the electron stopping power

We report an improved predictive formula for the electron stopping power (SP) based on an analysis and fit of SPs and electron inelastic mean free paths (IMFPs) calculated from optical data for 37 elemental solids and energies between 200 eV and 30 keV. The formula is a function of energy, density, and IMFP, and is recommended for solids with atomic numbers larger than 6. While the mean deviation between predicted and calculated SPs was 7.25%, larger deviations were found for four additional materials, Li (22.2%), Be (17.9%), graphite (15.3%), and diamond (15.7%). The predictive SP formula can be applied to multicomponent materials. Test comparisons for two compounds, guanine and InSb, showed average deviations of 16.0% and 19.1%, respectively. The improved SP formula is expected to be useful in simulations of electron trajectories in solids with the continuous slowing-down approximation (e.g., in Auger-electron spectroscopy and electron microprobe analysis)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of keV-Neutron Capture Gamma Rays for Se Isotopes

Neutron capture gamma rays were measured for all stable Se isotopes in an incident neutron energy region from 15 to 100 keV. A neutron time-of-flight method was adopted with a ns-pulsed neutron source based on the {sup 7}Li(p,n){sup 7}Be reaction and with a large anti-Compton NaI(Tl) spectrometer. A pulse-height weighting technique was applied to the observed capture gamma-ray pulse-height spectra to obtain the capture yields. Using the standard capture cross sections of {sup 197}Au, the capture cross sections of stable Se isotopes were derived with an error of about 5%. The capture gamma-ray spectra were obtained by unfolding the observed capture gamma-ray pulse-height spectra. The present results for the capture cross sections are compared with the previous measurements and the evaluations of JENDL-3.3 and ENDF/B-VI.8 and VII.0.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Silicon detectors for monitoring neutron beams in n-TOF beamlines

During 2014, the second experimental area (EAR2) was completed at the n-TOF neutron beam facility at CERN (n-TOF indicates neutron beam measurements by means of time of flight technique). The neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target. The resulting neutron beam covers the energy range from thermal to several GeV. In this paper, we describe two beam diagnostic devices, both exploiting silicon detectors coupled with neutron converter foils containing {sup 6}Li. The first one is based on four silicon pads and allows monitoring of the neutron beam flux as a function of the neutron energy. The second one, in beam and based on position sensitive silicon detectors, is intended for the reconstruction of the beam profile, again as a function of the neutron energy. Several electronic setups have been explored in order to overcome the issues related to the gamma flash, namely, a huge pulse present at the start of each neutron bunch which may blind the detectors for some time. The two devices were characterized with radioactive sources and also tested at the n-TOF facility at CERN. The wide energy and intensity range they proved capable of sustaining made them attractive and suitable to be used in both EAR1 and EAR2 n-TOF experimental areas, where they became immediately operational.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High pressure neutron diffraction on WAND 2 with a Paris-Edinburgh press

The Paris-Edinburgh press is a widely available, highly adaptable pressure cell commonly used while collecting neutron scattering data. Here, we detail the use of the VX3 and VX5 Paris-Edinburgh presses on the Wide-Angle Neutron Diffractometer (WAND 2 ) at the High Flux Isotope Reactor at Oak Ridge National Laboratory. We first give a detailed overview of the instrument setup and alignment capabilities used at WAND 2 . We then demonstrate the high pressure capabilities through three examples. In this work, the first example focuses on diffraction data obtained from a lithium-diamond mixture to 10 GPa with the use of single toroidal cubic boron nitride anvils. Other examples include the room temperature compressions of germanium (up to 16 GPa) and the mineral malachite with double toroidal sintered diamond anvils. This work thereby represents the first studies above 10 GPa at the High Flux Isotope Reactor and opens the door for future user experiments at these elevated pressures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron capture cross sections of {sup 74}Ge, {sup 76}Ge, and {sup 75}As at 25 keV

The neutron capture cross sections of {sup 74}Ge, {sup 76}Ge, and {sup 75}As have been measured at the Karlsruhe Van de Graaff accelerator by means of the activation technique. The neutron source reaction {sup 7}Li(p,n){sup 7}Be was used for simulating a thermal energy distribution for kT=25 keV to determine the astrophysically relevant stellar cross sections directly. Based on an extended series of activations, consistent results could be obtained, corresponding to Maxwellian average cross sections at kT=30 keV of 37.6{+-}3.9 mb for {sup 74}Ge, 21.5{+-}1.8 mb for {sup 76}Ge, and 362{+-}19 mb for {sup 75}As. These results are more accurate than previous data and are, therefore, important for resolving previous discrepancies. By extrapolation Maxwellian averaged cross sections were derived for thermal energies from 5 to 100 keV. The implications of these results for the s-process abundances in massive stars and for the background conditions in double {beta} decay experiments are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of the stellar (n,{gamma}) cross section of {sup 40}Ca with accelerator mass spectrometry

The stellar (n,{gamma}) cross section of {sup 40}Ca at kT=25 keV has been measured with a combination of the activation technique and accelerator mass spectrometry (AMS). This combination is required when direct off-line counting of the produced activity is compromised by the long half-life and/or missing {gamma}-ray transitions. The neutron activations were performed at the Karlsruhe Van de Graaff accelerator using the quasistellar neutron spectrum of kT=25 keV produced by the {sup 7}Li(p,n){sup 7}Be reaction. The subsequent AMS measurements were carried out at the Vienna Environmental Research Accelerator (VERA) with a 3 MV tandem accelerator. The doubly magic {sup 40}Ca is a bottle-neck isotope in incomplete silicon burning, and its neutron capture cross section determines the amount of leakage, thus impacting on the eventual production of iron group elements. Because of its high abundance, {sup 40}Ca can also play a secondary role as ''neutron poison'' for the s-process. Previous determinations of this value at stellar energies were based on time-of-flight measurements. Our method uses an independent approach, and yields for the Maxwellian-averaged cross section at kT=30 keV a value of <{sigma}>{sub 3}0 keV=5.73{+-}0.34 mb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characteristics of an OSLD in the diagnostic energy range

Purpose: Optically stimulated luminescence (OSL) dosimetry has been recently introduced in radiation therapy as a potential alternative to the thermoluminescent dosimeter (TLD) system. The aim of this study was to investigate the feasibility of using OSL point dosimeters in the energy range used in diagnostic imaging. Methods: NanoDot OSL dosimeters (OSLDs) were used in this study, which started with testing the homogeneity of a new packet of nanoDots. Reproducibility and the effect of optical treatment (bleaching) were then examined, followed by an investigation of the effect of accumulated dose on the OSLD indicated doses. OSLD linearity, angular dependence, and energy dependence were also studied. Furthermore, comparison with LiF:Mg,Ti TLD chips using standard CT dose phantoms at 80 and 120 kVp settings was performed. Results: Batch homogeneity showed a coefficient of variation of <5%. Single-irradiation measurements with bleaching after each OSL readout was found to be associated with a 3.3% reproducibility (one standard deviation measured with a 8 mGy test dose), and no systematic change in OSLDs sensitivity could be noted from measurement to measurement. In contrast, the multiple-irradiation readout without bleaching in between measurements was found to be associated with an uncertainty (using a 6 mGy test dose) that systematically increased with accumulated dose, reaching 42% at 82 mGy. Good linearity was shown by nanoDots under general x-ray, CT, and mammography units with an R{sup 2} > 0.99. The angular dependence test showed a drop of approximately 70% in the OSLD response at 90 deg. in mammography (25 kVp). With the general radiography unit, the maximum drop was 40% at 80 kVp and 20% at 120 kVp, and it was only 10% with CT at both 80 and 120 kVp. The energy dependence study showed a range of ion chamber-to-OSLDs ratios between 0.81 and 1.56, at the energies investigated (29-62 keV). A paired t-test for comparing the OSLDs and TLDs showed no significant variation (p > 0.1). Conclusions: OSLDs exhibited good batch homogeneity (<5%) and reproducibility (3.3%), as well as a linear response. In addition, they showed no statistically significant difference with TLDs in CT measurements (p > 0.1). However, high uncertainty (42%) in the dose estimate was found as a result of relatively high accumulated dose. Furthermore, nanoDots showed high angular dependence (up to 70%) in low kVp techniques. Energy dependence of about 60% was found, and correction factors were suggested for the range of energies investigated. Therefore, if angular and energy dependences are taken into consideration and the uncertainty associated with accumulated dose is avoided, OSLDs (nanoDots) can be suitable for use as point dosimeters in diagnostic settings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster - 24: Characterization of the energy dependence of high-sensitivity MCP-N TLD and Al2O3:C OSLD in-vivo dosimetry systems for 40–100 kVp energies

Purpose: To characterize the energy dependence of high-sensitivity MCP-N TLD and Al{sub 2}O{sub 3}:C OSLD dosimetry systems at low (40–100 kVp) energies for in-vivo dosimetry. Methods: We assessed the variation of response with energy of two detectors in the 40–100 kVp energy range: high-sensitivity MCP-N TLDs (LiF:Mg,Cu,P) and OSLDs (Al{sub 2}O{sub 3}:C). The detectors were irradiated with an XRad 320ix biological irradiator under reference conditions. The delivered dose was 10 cGy for 7 beam qualities ranging from 40–100 kVp, 1.7–4.0 mm Al, and effective energies 26.9–37.9 keV. Both sets of detectors were also irradiated under reference conditions at 6 MV using a Varian Clinac 21Ex to assess the change in response from high-energy beams. Results: The MCP-N high-sensitivity TLDs were relatively insensitive to energies in the kV range, as their response varied by ±5%, i.e. well within the reproducibility limits of these detectors. However, the OSLDs exhibited a linearly-decreasing response with energy with a response 18.7% higher at 40 kVp than at 100 kVp for the same nominal dose. Compared to the 6 MV beams used in conventional radiotherapy, OSLDs responded 3.3–3.9 times higher depending on beam quality while the MCP-N TLD response was unchanged within experimental uncertainty. Conclusions: Unlike the more commonly used TLD-100, the high-sensitivity MCP-N TLDs exhibit little to no energy response. OSLDs are shown to be highly energy-dependent, both from MV to kV and within the kV range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alkali metal-sulfur secondary battery containing cathode material particulates

Provided is a rechargeable alkali metal-sulfur cell comprising an anode active material layer, an electrolyte, and a cathode active material layer comprising multiple particulates, wherein at least one of the particulates comprises one or a plurality of sulfur-containing material particles being embraced or encapsulated by a thin layer of a conductive sulfonated elastomer composite having from 0.01% to 50% by weight of a conductive reinforcement material dispersed in a sulfonated elastomeric matrix material, wherein the conductive reinforcement material is selected from graphene sheets, carbon nanotubes, carbon nanofibers, metal nanowires, conductive polymer fibers, or a combination thereof and the composite has a recoverable tensile strain from 2% to 500%, a lithium ion conductivity from 10−7 S/cm to 5×10−2 S/cm, and a thickness from 0.5 nm to 10 μm. This battery exhibits an excellent combination of high sulfur content, high sulfur utilization efficiency, high energy density, and long cycle life.

Zhamu, Aruna↗

Extended cycle life implications of fast charging for lithium-ion battery cathode

Enabling extreme fast charging (XFC, =10–15 min charging) requires a comprehensive understanding of its implications. While lithium plating is a key bottleneck for the anode, the full extent of limitations for the cathode are not well-understood, particularly in extended-cycle settings with well-defined battery designs and conditions. This article presents cycle-life implications of XFC on cathodes at multiple length scales, combining electrochemical analyses, degradation modeling, and post-test characterizations. The comprehensive test matrix includes 41 well-defined gr/NMC pouch cells under varied fast-charge rates (1–9C) and state-of-charges cycled up to 1000 times. Cathode issues remain minimal in early cycling, but begin to accelerate in later life, when distinct cracking is found and identified as a fatigue mechanism. The bulk structure of cathodes remains intact, but distinct particle surface reconstruction is observed; however, this shows less pronounced effect on cathode aging than does cracking.

25 ENERGY STORAGE↗

Radiation damage and defect behavior in proton irradiated lithium-counterdoped n+p silicon solar cells

Two lithium-counterdoped n+p silicon solar cells with different lithium concentrations were irradiated by 10-MeV protons. Cell performance was measured as a function of fluence, and it was found that the cell with the highest concentration of lithium had the highest radiation resistance. Deep level transient spectroscopy which showed two deep level defects that were lithium related. Relating the defect energy levels obtained from this study with those from earlier work using 1-MeV electron irradiation shows no correlation of the defect energy levels. There is one marked similarity: the absence of the boron-interstitial-oxygen-interstitial defect. This consistency strengthens the belief that lithium interacts with oxygen to prevent the formation of the boron interstitial-oxygen interstitial defect. The results indicate that, in general, addition of lithium in small amounts to the p-base of a boron doped silicon solar cell such that the base remains p-type, tends to increase the radiation resistance of the cell.

Stupica, John↗

Lithium Dendrite-Free Li 7 N 2 I-LiOH Solid Electrolytes for High Energy Lithium Batteries

All-solid-state lithium batteries (ASSLBs) hold great potential to improve the safety and energy density of today’s lithium-ion batteries by using non-flammable inorganic solid electrolytes. Solid electrolytes (SEs) are believed to prevent Li dendrite growth because of high mechanical strength and high Li+ transference numbers. Significant advances in SE have been achieved, among which, Li7La3Zr2O12 (LLZO) and Li2S–P2S5 (LPS) are the most promising SEs for bulk-type solid-state lithium batteries because of high ionic conductivities (>10-4 S/cm2). However, in contrast to our expectations, the growth of lithium dendrites is not suppressed but is facilitated in LLZOs and LPSs regardless of dopants, porosity, and crystallinity of the electrolytes. Despite the unity Li transference number and over two-times of shear modulus than that of Li metal, the critical current densities for Li plating and stripping in these SEs are less than 1.0 mA cm-2, which is one-fourth to one-tenth of that in liquid electrolytes at room temperature. The incompatibility between LLZO and LPS with Li metal seriously limits the energy density of all-solid-state batteries. The mechanism for lithium dendrite formation and growth in SEs are still disputable. Lack of understanding of the Li dendrite formation mechanism seriously impeded the development of solid-state lithium batteries. The development of the criterion for Li dendrite suppression is essential for the success of solid electrolyte lithium batteries. In this project, a criterion for Li dendrite suppression will be developed through thermodynamics and kinetics analysis of lithium dendrite nucleation/growth, which will guide the solid-state electrolyte design. Li7N2I-LiOH, Li5NI2-LiOH and Li3YCl6 solid electrolyte with high ionic conductivity and low electronic conductivity were used to validate the criterion for lithium dendrite suppression. Different surface modifications were also explored to enhance the dendrite suppression capability of SSEs.

25 ENERGY STORAGE↗

{sup 8}Be scattering potentials from reaction analyses

New angular distributions for the {sup 7}Li({sup 10}B,{sup 9}Be){sup 8}Be reaction at an energy of E{sub lab}({sup 10}B)=51 MeV for the ground and excited states of {sup 8}Be were analyzed within the coupled-reaction-channels method. The reactions are dominated by single proton transfer at forward angles except for that to the {sup 8}Be 11.35-MeV state, which requires multistep routes for its population. The {sup 8}Be+{sup 9}Be potential parameters for ground and excited states of {sup 8}Be were deduced by fitting {sup 7}Li({sup 10}B,{sup 9}Be){sup 8}Be and {sup 10}B({sup 7}Li,{sup 9}Be){sup 8}Be reaction data and are compared with a previously determined {sup 7}Be+{sup 9}Be potential. The {sup 8}Be+{sup 9}Be real potential is very similar to that for {sup 7}Be+{sup 9}Be, whereas the imaginary one for {sup 8}Be+{sup 9}Be has a much greater spatial extent than that for {sup 7}Be+{sup 9}Be.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗