Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIQUID WASTES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluation of Hanford Supernatant Waste Evaporation

• Hanford site in Washington has 27 underground “double-shell” storage tanks containing radioactive waste. Storage space is utilized to max capacity. • Construction of new tanks is undesirable, but volume reduction is still possible by vacuum evaporation of liquid waste. • Excess evaporation may create additional problems in solids precipitation, waste density and corrosivity. • Evaporation of liquid waste was simulated to determine possible outcomes.

Barkai, Benjamin [Savannah River National Laborato↗

Challenges and Solutions in Operation and Lay-Up of the Modular Caustic- Side Solvent Extraction Unit - 20078

The Modular Caustic-Side Solvent Extraction (CSSX) Unit (MCU) was designed and constructed to provide interim salt waste processing so that the Liquid Waste Disposition Program (LWDP) could continue waste removal and tank closure until start-up of the Salt Waste Processing Facility (SWPF). MCU processes Clarified Salt Solution (CSS), or salt solution (SS) that has undergone actinide removal/filtration, to produce two waste streams: the cesium laden Strip Effluent (SE), which is incorporated into glass at the Defense Waste Processing Facility (DWPF), and the cesium depleted Decontaminated SS (DSS), which is incorporated into grout at the Saltstone Production Facility (SPF). MCU completed start-up in 2008 with an initial operating life of 3 years and design life of 5 years. Prior to reaching the end of the design life, multiple critical components were upgraded and/or replaced to mitigate risks associated with any delays in SWPF start-up. During the remainder of operation (until June 2019), MCU was challenged to maximize processing with minimal additional modifications to repair/improve aging infrastructure, while maintaining low levels of risk to workers and the environment. Notable challenges during the extended operating life of the facility involved both mechanical and operational issues. Two of the most significant issues were the increased frequency of Process Vessel Ventilation (PVV) High Efficiency Particulate Air (HEPA) filter change-outs and the biofouling of the SE coalescer (SEC). The major impacts of both issues were that replacement of these components 1) resulted in high exposure to workers, and 2) required substantial downtime, thus hindering achievement of processing goals. PVV HEPA filter replacements are required based on dose rate and differential pressure (dP) limits. After introducing a higher-curie feed to MCU, the operating time between change outs was reduced by approximately half. SEC replacements are required based on dP limits. After restarting from an extended outage, the operating life of the SEC was significantly reduced by more than half due to biofouling. As a result of extensive troubleshooting and process improvements, the facility was able to recover performance and extend the operating life of the PVV HEPA filters and the SEC media. Through troubleshooting both of these issues, the facility was also able to learn from prior experience and adapt in order to minimize down time and maintain throughput. Although the facility took advantage of short periods of downtime to perform nonintrusive troubleshooting and minor corrective/preventative maintenance activities, longer outages were periodically required for corrective maintenance involving process cell entry. During these outages, remote tools and specialized shield plates were employed to minimize dose to workers. Mock-ups of non-routine maintenance activities were critical to early identification of potential issues and improvements, which shortened outage duration. Consistent with the facility's operational strategy, evolutions needed for MCU layup were identified and sequenced to ensure safe conditions within the facility, meet pre-defined criteria for lay-up configuration, and protect workers, while minimizing the impact to SWPF integration. De-inventory and flushing of process areas was prioritized so that the total residual inventory was reduced as efficiently as possible. This paper discusses lessons learned and best practices from troubleshooting unique issues, performing complex maintenance activities, and implementing a layup strategy that best supports the overall system mission. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utilizing Commercial Submersible Mixer Pumps for Sludge Removal in Savannah River Site's Tank 26 - 20289

The Savannah River Site (SRS) Liquid Waste System (LWS) safely manages, stores, treats, and dispositions liquid radioactive waste. The LWS consists of 51 underground waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities, known as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). One of the waste storage tanks, Tank 26, was placed into service in 1980 as an F Tank Farm (FTF) Evaporator Feed Tank. From 1980 to 2013, Tank 26 received F Canyon receipts and dilute supernate that was then transferred to the 242-16F FTF Evaporator for volume reduction. In 2013, the steam tube bundle failed in the FTF Evaporator, and the decision was made not to repair/resume evaporator operation. During operation of Tank 26, solids built up to a level of 2.03 m in the tank with a volume of 1062.9 kL. Due to the evaporator failure and subsequent shutdown, the solids in Tank 26 were selected to feed Sludge Batch 10, which is collected and prepped prior to being sent to DWPF for final disposition. To accomplish solids removal, Commercial Submersible Mixer Pumps (CSMPs) were selected to slurry the solids in preparation to be sent to Tank 51. Four CSMPs were installed in Tank 26 with each one installed in a separate quadrant of Tank 26. This work would mark the first deployment of CSMPs in an SRS waste tank. The CSMPs were developed in response to operational issues from previous mixing pumps and budgetary constraints. The CSMPs use the concept of modifying commercially available equipment for nuclear waste applications. The CSMPs consist of a 230-horsepower submersible mixing pump (manufactured by GPM, Inc.) joined to a mast fabricated at SRS. For this application, Savannah River Remediation (SRR) design services was challenged to provide a mast design that required no steel superstructure support system on top of Tank 26. Also, SRR design services provided a simplified Tank 26 riser interface that did not require extensive machine parts to adjust height of the suction screen of the CSMP within the tank. Other design improvements include no requirements for tank top radiation monitors and no requirements for flushing of the CSMPs during startup/shutdown operations. The CSMPs were operated at an initial height of 2.29 m above the Tank 26 bottom for 10 days. After sludge sounding, the CSMPs were lowered to a height of 1.52 m with no issues due to proper work planning and the simplified riser interface. With the CSMPs lowered to a level of 1.52 meters above the tank bottom, the CSMPs were operated for 12 days and another sounding was performed. The sounding level came back matching the disturbance depth results of the first pump run. Chemistry samples were analyzed while the tank was left to settle. The analysis revealed enough weight percent solids to provide good feed to Sludge Batch 10. Also, the results revealed the supernate within the mixture would provide good salt solution feed to Salt Waste Processing Facility (SWPF) Salt Batch 3. So, the plan was modified to let the disturbed solids settle and decant the salt solution for addition to SWPF Salt Batch 3. Then water will be added back to Tank 26, and the CSMPs run in order to wash the solids to decrease settling time prior to being sent to Tank 51 for Sludge Batch 10. Utilizing CSMPs for waste removal in an SRS Tank has provided a cost-effective means for further waste removal efforts. In addition, the CSMPs are easier to operate by utilizing a robust and simplified design. The CSMPs performed quite well with no process shutdown or delays during operation. As a result, CSMPs are integral to the future of removing radioactive waste from storage tanks at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Current Status of the Synroc Waste Treatment Facility - 20263

Construction of the Synroc Waste Treatment Facility is well underway at ANSTO. This plant has been designed to treat intermediate level liquid waste arising from the production of Mo-99 within the newly constructed ANSTO Nuclear Medicine (ANM) precinct [1]. The facility utilises ANSTO Synroc technology that has been tailored to the chemical, physical, and radiological properties of the waste. The result is a highly durable wasteform with a significant reduction in the final volume of the treated waste. This paper presents the construction status of the Synroc Waste Treatment Facility and the status of the associated technology maturation plan. Construction of the building is scheduled for completion in late 2020 followed by process installation and commissioning. A key component of the technology maturation plan has been the construction of an Inactive Engineering Demonstrator [2]. This has aided in the mitigation of risks with respect to technology selection, process integration, and process nuclearisation. Furthermore, the demonstration facility has provided an environment for the design and development of the instrumentation and control philosophy resulting in a seamlessly integrated plant control system. Successful demonstration of the technology by the inactive engineering demonstrator has significantly reduced the associated risks. Details of the Synroc Waste Treatment Facility project progress will also be presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conceptual Model Testing Related to SDU 6 Drainwell Observations

From its inception in the early 1950s through the end of the Cold War in the early 1990s, the Savannah River Site (SRS) produced nuclear materials for national defense in five reactors. Additionally, irradiated reactor fuel and target tubes were dissolved in nitric acid to recover plutonium and uranium using the PUREX (Plutonium Uranium Reduction EXtraction) process. Liquid waste from these chemical separations processes was then stored onsite in 51 underground tanks. Eight waste storage tanks have been operationally closed (i.e. cleaned and grouted) and the remaining tanks hold a mixture of liquids, insoluble solids, and precipitated salts (SRMC-LWP-2022-00001), the latter generated by evaporating water from the liquid waste. Waste is currently being retrieved from tanks and separated into 1) high-radioactivity, low-volume, and 2) low-radioactivity, high-volume components, principally through the Salt Waste Processing Facility (SWPF) (SRMC-LWP-2023-00001). The former waste stream is vitrified in the Defense Waste Processing Facility (DWPF), stored onsite, and destined for offsite disposal in a deep geologic repository. The latter stream is mixed with dry cementitious materials in the Saltstone Production Facility (SPF) and the wet slurry placed in onsite Saltstone Disposal Units (SDUs) within the Saltstone Disposal Facility (SDF), where it hardens into a cement waste form termed saltstone. A low-infiltration surface cover system will be placed over the SDF at closure, where SDUs will then be in the subsurface post-closure (SRR-CWDA-2019-00001).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ECLSS Sustaining Metal Materials Compatibility Final Report, Electrochemical and Crevice Corrosion Test Results

Electrochemical test results are presented for six noble metals evaluated in two acidic test solutions which are representative of waste liquids processed in the Environmental Control and Life Support System (ECLSS) aboard the International Space Station (ISS). The two test solutions consisted of fresh waste liquid which had been modified with a proposed or alternate pretreatment formulation and its associated brine concentrate. The six test metals included three titanium grades, (Commercially Pure, 6Al-4V alloy and 6Al-4V Low Interstitial alloy), two nickel-chromium alloys (Inconel® 625 and Hastelloy® C276), and one high tier stainless steel (Cronidur® 30).

Lee, R. E.↗

Soil Desiccation Treatability Testing at BC Waste Disposal Cribs

During Hanford’s production period, low-level waste products generated from chemical processing of uranium fuel rods were discharged directly to the ground through a system of cribs and trenches located in the 200-BC-1 Operable Unit (OU). The site consists of 6 cribs and 20 trenches that received more than 117,000 m3 of radioactive liquid waste discharged to the soil. These unlined infiltration galleries held volumes of liquid waste while it seeped into the ground, with the understanding that the 100 m (330 ft) thick vadose zone in the area would effectively capture the effluent and prevent groundwater impacts. A conceptual model showing the operation of cribs and trenches is shown in Figure 1. Data show effluent from the 26 cribs and trenches containing about 410 curies of Technetium-99 (Tc-99) is primarily located between 30 m and 70 m (98 ft and 230 ft) depth (Corbin et al., 2005; Ward et al., 2004). Despite no evidence indicating that the contamination has reached the groundwater at BC cribs and trenches, the mobility of Tc-99 had been demonstrated in laboratory tests and was recognized as a threat to groundwater at the site. Using data from numerical models, laboratory analyses, field investigations, and information on historical discharges, the EPA and Ecology identified Tc-99 and U contamination of the vadose zone as a remediation priority. The U.S. DOE was notified by EPA and Ecology regarding risks associated with Tc-99 contamination in a letter requesting development of a strategy for improved methods to understand the nature and extent of vadose zone contamination, specifically Tc-99, and to develop remedial options for addressing such contamination. To develop the appropriate technology for characterizing, remediating, and monitoring the deep vadose zone Tc-99 contamination, the U.S. DOE worked with the EPA and Ecology to create a Treatability Test Plan under a Remedial Investigation/Feasibility Study (RI/FS) for the Hanford 200 Areas. Under this RI/FS, it was determined that a treatability test for soil desiccation should be carried out as it was identified as a promising in-situ treatment technology for mitigating risks posed by Tc-99 contamination to the groundwater table. The BC Cribs and Trenches site was identified as a representative site for Tc-99 and U contamination and selected for the soil desiccation treatability test. In this chapter, we summarize the overlying regulatory framework of RI/FS and treatability tests and illustrate how development and experimentation supported the evaluation of selected remedies. We briefly discuss the RI/FS for the 200 Areas of the Hanford Site and focus on the soil desiccation treatability testing performed at the BC cribs and trenches site under the Deep Vadose Zone Treatability Test Plan for the Hanford Central Plateau (DVZ-TT). The DVZ-TT is one component of the remedial investigation/feasibility study for the Hanford 200 Areas and represents the underlying regulatory framework that drives site operations towards records of decision and site closure.

Mangel, Adam R.↗

Investigation of new hypergol scrubber technology

The ultimate goal of this work is to minimize the liquid waste generated from the scrubbing of hypergolic vent gases. In particular, nitrogen tetroxide, a strong oxidizer used in hypergolic propellant systems, is currently scrubbed with a sodium hydroxide solution resulting in a hazardous liquid waste. This study investigated the use of a solution of potassium hydroxide and hydrogen peroxide for the nitrogen textroxide vent scrubber system. The potassium nitrate formed would be potentially usable as a fertilizer. The hydrogen peroxide is added to convert the potassium nitrite that is formed into more potassium nitrate. Smallscale laboratory tests were conducted to establish the stability of hydrogen peroxide in the proposed scrubbing solution and to evaluate the effectiveness of hydrogen peroxide in converting nitrite to nitrate.

Glasscock, Barbara H.↗

The Influence of Alkalinity on the Uptake of Cs{sup +} and Sr{sup 2+} by Cation-substituted Natisites in Sodium-bearing Conditions - 20336

The titanosilicate natisite (Na{sub 2}TiSiO{sub 5}) is a kinetic phase of the mineral sitinakite (Na{sub 2}Ti{sub 2}O{sub 3}SiO{sub 4}.2H{sub 2}O), which is a reference material in the removal of Cs and Sr from radioactive high-level waste. Natisite is disregarded in the literature as a candidate sorbent for Cs and Sr, despite being more thermally stable than sitinakite, which is a critical property for this application. Replacing portion of the Ti in natisite by other metals is believed to enhance natisite sorption properties. In nuclear waste remediation, Cs and Sr are contained in high-salinity liquid wastes that can either be highly acidic or alkaline. In the present study, Al-, Sn-, and Zr-natisites were synthesized, and compared to pure natisite and sitinakite in batch experiments. Five concentrations of NaOH and NaNO{sub 3} (i.e. source of Na{sup +}) mimicking conditions of high alkalinity, and competing Na{sup +} ions, respectively, were evaluated. Sorption results demonstrate that sitinakite is generally more effective than all four natisites in removing Cs and Sr. However, sitinakite uptake mechanism seems to deteriorate at increasing concentrations of base and Na{sup +}. Although less selective than sitinakite, all natisite sorbents provided a less dramatic decline in Cs and Sr uptake through increasing molarities. Overall, there was an improvement in the sorption of Cs and Sr by the metal-substituted materials over natisite and, in neither of the testing solutions, natisite outperformed its substituted variants. In highly alkaline solutions, Sn- and Zr-Natisite provided for exceptional removal for Sr, removing more than twice the amount sorbed by sitinakite at 0.1 M NaOH. The results obtained for Sr uptake by all four natisite materials in alkaline solutions are promising, especially considering the highly alkaline nature of wastes from the nuclear industry. Future studies should investigate the sorption mechanisms responsible for natisite selectivity for Sr at high pH. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plutonium Solubility and Supernate Concentration for Neutralized Fast Critical Assembly Discards to Savannah River Site Tank Waste

The Savannah River Site (SRS) plans to dissolve non-irradiated stainless steel (SS)-clad bundles of Fast Critical Assembly (FCA) materials in eighteen batches.1 FCA dissolution is currently underway in the 6.3D dissolver by simultaneous chemical and electrolytic dissolution, which is required to generate the harsh conditions necessary for dissolution of metal-oxide (MOX) and non-aluminum spent nuclear fuels (NASNFs).2 Nitric acid and potassium fluoride are used to promote chemical dissolution.2 Gadolinium will be added during processing as a thermal neutron poison for criticality control. There are no plans for recovering plutonium from this waste stream. After FCA dissolution, the acidic (HNO3/KF) “discards” containing the dissolved metals will be neutralized by addition of 50 wt% sodium hydroxide to a final free hydroxide concentration of 1.2 M.1 Neutralization will precipitate a slurry of insoluble solids, predominantly metal oxides/hydroxides of plutonium, uranium, and SS components. Small fractions of the SS components, Pu, U, and Gd will remain dissolved in the supernate. The neutralized slurry will be composited to existing radioactive waste storage tanks within the SRS Concentration, Storage, and Transfer Facilities (CSTF) containing other similar sludge batch (SB) materials.1 The fate of soluble plutonium and freshly-precipitated, colloidal plutonium from this process are of concern since the total Pu can challenge the waste acceptance criteria (WAC) at the downstream SRS Liquid Waste (LW) facility. Supernate decants including the neutralized FCA discards (nFCAd) within the CSTF will be composited with salt batch (StB) materials and transferred to the SRS Salt Waste Processing Facility (SWPF), where total plutonium is also of concern.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Fermentation-Derived Substrates on Hydrogen Production in Zero-Gap Microbial Electrolysis Cells

Zero-gap microbial electrolysis cells (MECs) represent a promising platform for hydrogen production from liquid waste streams due to reduced interelectrode spacing that lowers internal resistance and enhances mass transport. However, the performance and stability of zero-gap MECs treating chemically complex feedstocks remain insufficiently characterized. Here, we operated zero-gap MECs with real, unamended, corn stover dark fermentation effluent containing a wide range of organic substrates. The MECs fed fermentation effluent achieved a maximum current density of 24 A/m2 (15+-6 A/m2 over the cycle) and a hydrogen production rate of 75 L/L-d (42+-19 L/L-d over the cycle). The substrates were consumed at different rates, indicating substrate-selective utilization by the anodic microbial community. Acetate supported high and stable current generation, whereas ethanol, formate, lactate, and amino acids induced varying degrees of inhibition depending on their concentration. Residual sugars caused pronounced current fluctuations, consistent with ongoing fermentation and local pH changes. A diverse microbial community was crucial for efficiently utilizing complex organics and maximizing electrochemical performance. These results demonstrate how and to what extent substrate composition regulates zero-gap MEC performance and that microbial community and operational conditions can be leveraged to enhance performance. These novel findings provide practical guidance for achieving robust hydrogen recovery from chemically heterogeneous real liquid waste streams.

08 HYDROGEN↗

Impact of reactor architecture and design parameters on the performance of microbial electrolysis cells revealed by the electrode potential slope analysis

Microbial electrolysis cells (MECs) are appealing for recovering the chemical energy contained in domestic and industrial liquid wastes as hydrogen gas. Despite several years of research in the field, there is still a lack of critical analysis of how the reactor architecture dictates the electrochemical performance of the cell. In this study, internal resistance and onset voltage from the electrode potential slope analysis (EPS) were used in combination with current density, hydrogen production rate, reactor packing density, electrode spacing, membrane type and composition from 23 different studies to identify the reactor design parameters that primarily govern electrochemical performance of MECs. Using anion exchange membranes resulted in smaller internal resistances (AEM R int = 41± 40 mΩ m 2 ) and larger current density (18 ± 14 A m −2 ) compared to single chamber reactors (SC R int = 68 ± 58 mΩ m 2 ; 22 ± 16 A m −2 ) or MECs with cation exchange membranes (CEM R int = 376 ± 280 mΩ m 2 ; 3.0 ± 2.1 A m −2 ). Higher electrochemical performance for AEM- and SC-MECs translated in larger hydrogen gas production rates (0.122 mL H 2 C −1 for AEM vs 0.117 mL H 2 C −1 for SC), but only when inhibitors against hydrogen scavengers were added in single chamber systems (0.080 mL H 2 C −1 for SC without inhibitors). Following membrane type and composition, maintaining a small electrode spacing was the most critical parameter to improve MEC performance, indicating that the low conductivity of the media primarily limit performance by increasing ohmic resistance. Here, reactor volume and electrode surface area negatively correlated with internal resistance and current density, indicating that better performance of scaled-up reactors can likely be obtained by stacking multiple smaller units rather than just increasing reactor size. Although challenges remain in the implementation of MECs for hydrogen production from liquid wastes, advances in electrochemical engineering of the reactors can facilitate scale up and performance prediction at scale.

Electrochemistry↗

Impact of dilution-induced precipitates on the filtration of Hanford liquid tank wastes

To facilitate its vitrification, a portion of the radioactive wastes currently stored at the Hanford Site will be staged and treated using tank-side operations to render their chemistry compliant with the requirements of Hanford’s low-activity waste vitrification facility. Initial sampling of staged feeds indicates that process-water dilution, used to reduce waste feed sodium content to levels acceptable for vitrification (5–6 M Na), may cause precipitation of fine, difficult to settle solids that could affect downstream tank-side filtration and ion-exchange. However, dilution-induced precipitation has not been demonstrated under controlled, rigorous laboratory conditions. This paper presents a set of qualitative and quantitative assessments of dilution-induced precipitation using a nonradioactive, Hanford Tank AP-105 simulated waste. Further, these studies found that dilution of AP-farm waste simulants induced precipitation of up to 150 ppm solids, regardless of whether dilution was done with process water (which contains, among other analytes, naturally occurring Ca and Mg) or deionized water. Naturally occurring process-water analytes appeared to accelerate the rate (and possibly extent) of precipitation. Filtration of diluted waste simulants also found that the precipitated solids challenged prototypic tank-side filter operations; however, the impact to filtration performance was readily managed through waste staging settle/decant operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of Glycolate Anion on Aqueous Corrosion in DWPF and Downstream Facilities – SCC Testing

Glycolic acid is being evaluated as an alternate reductant in the preparation of High Level Waste for the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS). During processing, the glycolic acid may not be completely consumed with small quantities of the glycolate anion being carried forward to waste facilities. The SRS liquid waste contractor requested an assessment of the influence of the glycolate anion on the corrosion of the materials of construction (MoC) throughout the waste processing system since this concern had not been previously evaluated. The influence of glycolic acid on the occurrence of stress corrosion cracking (SCC) had not been evaluated specifically in the previous testing. The present testing used electrochemical and coupon immersion testing to assess this influence. Additionally, the primary guidance on corrosion for operating DWPF with a formate-based flowsheet is based on testing that utilized test solutions with a small number of constituents. Recent testing used more complex solutions based on flowsheet development for DWPF. Additional electrochemical tests were also conducted to assess the influence of this difference on test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enclosed Cutting-And-Polishing Apparatus

Proposed apparatus cuts and polishes specimens while preventing contamination of outside environment or of subsequent specimens processed in it. Designed for use in zero gravity but also includes features useful in cutting and polishing of toxic or otherwise hazardous materials on Earth. Includes remote manipulator for handling specimens, cutting and polishing wire, inlets for gas and liquid, and outlets for waste liquid and gas. Replaceable plastic liner surrounds working space.

Rossier, R. N.↗

Investigation into Reductive Separation of Tc-99 from Low Activity Waste Off-Gas Condensate by Zero Valent Iron Materials - 20311

This study is investigating the potential for reductive separation of technetium-99 (Tc) from off-gas condensate generated from vitrification of legacy tank waste at the Hanford Tank Waste Treatment and Immobilization Plant. Management of Tc is a high-priority activity for the U.S. Department of Energy (DOE) Office of Environmental Management (EM) complex, which must be addressed based on knowledge gaps and technology development needs outlined in the DOE-EM Technetium Management Program Plan [1]. Technetium is one of the main risk drivers in the permanent disposal of low activity waste (LAW) by vitrification at the Hanford Site due to its high volatility and only fractional incorporation into borosilicate glass. Volatilized Tc will be captured by an off-gas treatment system, and the current plan is to continuously recycle generated condensate back to the LAW glass melter feed. Off-gas recycling is effective at increasing Tc loading in the LAW glass, but it also disproportionately increases concentrations of sulfate, halides, and other volatile compounds impeding overall LAW processing leading to significantly greater waste glass volume requirements. Removal of Tc from secondary liquid waste offers an alternative disposal route to continuous off-gas recycling which may result in significant reduction of the volumes of LAW waste glass and substantial cost savings. The objective of this research funded by the DOE-EM Minority Serving Institutions Partnership Program (MSIPP) is to determine the suitability of zero valent iron (ZVI) as a separation technology to remove Tc from the off-gas condensate stream to minimize its recycle. While ZVI has been proposed for various remediation applications with Tc, it has not been studied for its suitability for removing Tc from the LAW off-gas condensate. The goal is to identify the optimal conditions for which Tc{sup (VII)} will be reduced to Tc{sup (IV)} species and incorporated into an iron matrix. This paper presents a programmatic overview of our evaluation of commercial ZVI materials for their efficiency towards Tc{sup (VII)} reductive removal from simplified off-gas simulant solutions under aerobic conditions. Tc concentrations in solutions were monitored for up to 30 days to determine efficiency and kinetics of reductive removal of Tc. The best performing candidate materials were selected for further experiments evaluating the effects of (1) variable ionic strength, (2) the presence of chromium and corrosive anions, and (3) ZVI aging on Tc{sup (VII)} reductive removal in batch experiments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Biosorption of Uranium by Bone Meal

The treatment of aqueous solution waste containing organic compounds and radionuclides has always been a great concern since the processes available are usually expensive and unfeasible for the low volume of radioactive liquid waste recovered. In view of a more efficient and low cost treatment, biosorption-based technologies for the removal of this hazardous radionuclides, heavy metals, and organic substances from contaminated matrices have been studied as an alternative process. In this context, bone meal is the material of choice, and contains calcium phosphate in the form of hydroxyapatite. Previous studies with hydroxyapatite showed that this material is efficient in removing heavy metals from polluted soils due to its adsorbing ability. In this context, uranium biosorption capacity by using bone meal was evaluated by different experimental conditions. This study aims at analyzing the capacity of bone meal to remove uranium from aqueous solution through biosorption process, considering that this nuclide is radiotoxic and may cause serious environmental problems and risks to human life if not correctly disposed. The biosorption capacity of U by bone meal was evaluated under different experimental conditions. The results suggested that adsorption with this material can be applied in the treatment of aqueous solutions as a low-cost and highly efficient alternative to remove U. Therefore, we believe that our results are useful for other investigators dealing with similar problems. Further work is required to evaluate this material as a potential adsorbent concerning the treatment of liquid organic radioactive waste containing uranium. Next studies are crucial to ascertain the biosorption efficiency, by analyzing other variables, such as adsorbent dosage, pH and temperature.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Algebraic expressions for estimating the impact depths of a surface barrier over a homogeneous soil

Engineered surface barriers are used to isolate subsurface contaminants for effective long-term containment of municipal solid waste, other nonhazardous solid and liquid waste, hazardous and toxic wastes, and radioactive waste. The impact depths of a surface barrier are affected by the pre-barrier recharge rate and the properties of the soil beneath the barrier. In this paper, the pore-size-specific (PSS) water velocity is defined and an algebraic expression of PSS velocity is derived based on the stream tube concept and the Brooks and Corey hydraulic retention model. Algebraic expressions are developed to estimate drainage velocities and barrier impact depths after the emplacement of a surface barrier. Four impact depth terms are used to convey the protective effect: drainage front, average drainage, the location with 50% impact, and drainage tail. The drainage front depth is the deepest point at which the barrier has a detectable impact at a specific time (also called the near zero-impact depth). The average-impact depth is the depth at which average drainage occurs. At the 50% impact depth, the water flux rate is reduced by half because of the surface barrier. Lastly, the drainage tail depth (also called the full-impact depth) is the deepest depth at which the water conditions above it are in equilibrium with the barrier. The algebraic expressions show that the average-impact depth is no more than 1/3 of near zero-impact depth, while the 50% impact depth is slightly larger than 1/2 of the near zero-impact depth. The full-impact depth, depending on the final recharge rate from the surface barrier, is usually much smaller than the other impact depths. These differences lead to a very large transition zone beneath a surface barrier. Numerical simulations were conducted to replicate the same conditions. The numerical results corroborated the analytical models by predicting very similar water content profiles and near zero-, average-, 50%, and full-impact depths. The algebraic expressions provided in this paper are useful for quickly identifying sites where the depth of the existing contaminants could be beyond the protection of a surface barrier.

54 ENVIRONMENTAL SCIENCES↗