Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEAKAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Embolization for Thoracic Duct Collateral Leakage in High-Output Chylothorax After Thoracic Surgery

PurposeThis study was designed to investigate thoracic duct collateral leakage and the supply route of lymphatic fluid by lymphangiography and transcatheter thoracic ductography and to evaluate the results of embolization for thoracic duct collateral leakage performed to cut off this supply route.MethodsData were retrospectively collected from five patients who underwent embolization for thoracic duct collateral leakage in persistent high-output chylothorax after thoracic surgery. Extravasation of lipiodol at the ruptured thoracic duct collaterals was confirmed in all patients on lymphangiography. Transcatheter thoracic ductography was used to identify extravasation of iodinated contrast agent and to identify communication between the thoracic duct and leakage site. Thoracic duct embolization (TDE) was performed using the percutaneous transabdominal approach to cut off the supply route using N-butyl cyanoacrylate (NBCA) mixed with lipiodol (1:5–1:20).ResultsClinical success (drainage volume ≤10 mL/kg/day within 7 days after TDE) was achieved in all patients. The collateral routes developed as consequence of surgical thoracic duct ligation. In three patients, NBCA-Lipiodol reached the leakage site through direct communication between the thoracic duct and the ruptured lymphatic duct. In the other two patients, direct communication and extravasation was not detected on thoracic ductography, and NBCA-Lipiodol did not reach the leakage site. However, NBCA-Lipiodol did reach the cisterna chyli, lumbar trunks, and some collateral routes via the cisterna chyli or lumbar lymphatics. As a result, leakage was stopped.ConclusionsTDE was effective for the management of leakage of the collaterals in high-output chylothorax after thoracic surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Semi-Analytical Solution for Large-Scale Injection-Induced PressurePerturbation and Leakage in a Laterally Bounded Aquifer-AquitardSystem

A number of (semi-)analytical solutions are available to drawdown analysis and leakage estimation of shallow aquifer-aquitard systems. These solutions assume that the systems are laterally infinite. When a large-scale pumping from (or injection into) an aquifer-aquitard system of lower specific storativity occurs, induced pressure perturbation (or hydraulic head drawdown/rise) may reach the lateral boundary of the aquifer. We developed semi-analytical solutions to address the induced pressure perturbation and vertical leakage in a 'laterally bounded' system consisting of an aquifer and an overlying/underlying aquitard. A one-dimensional radial flow equation for the aquifer was coupled with a one-dimensional vertical flow equation for the aquitard, with a no-flow condition imposed on the outer radial boundary. Analytical solutions were obtained for (1) the Laplace-transform hydraulic head drawdown/rise in the aquifer and in the aquitard, (2) the Laplace-transform rate and volume of leakage through the aquifer-aquitard interface integrated up to an arbitrary radial distance, (3) the transformed total leakage rate and volume for the entire interface, and (4) the transformed horizontal flux at any radius. The total leakage rate and volume depend only on the hydrogeologic properties and thicknesses of the aquifer and aquitard, as well as the duration of pumping or injection. It was proven that the total leakage rate and volume are independent of the aquifer's radial extent and wellbore radius. The derived analytical solutions for bounded systems are the generalized solutions of infinite systems. Laplace-transform solutions were numerically inverted to obtain the hydraulic head drawdown/rise, leakage rate, leakage volume, and horizontal flux for given hydrogeologic and geometric conditions of the aquifer-aquitard system, as well as injection/pumping scenarios. Application to a large-scale injection-and-storage problem in a bounded system was demonstrated.

54 ENVIRONMENTAL SCIENCES↗

Design Support of an Above Cap-rock Early Detection Monitoring System using Simulated Leakage Scenarios at the FutureGen2.0 Site

The FutureGen 2.0 Project will design and build a first-of-its-kind, near-zero emissions coal-fueled power plant with carbon capture and storage (CCS). To assess storage site performance and meet the regulatory requirements of the Class VI Underground Injection Control (UIC) Program for CO 2 Geologic Sequestration, the FutureGen 2.0 project will implement a suite of monitoring technologies designed to evaluate CO 2 mass balance and detect any unforeseen loss in CO 2 containment. The monitoring program will include direct monitoring of the reservoir, and early-leak-detection monitoring directly above the primary confining zone. This preliminary modeling study described here focuses on hypothetical leakage scenarios into the first permeable unit above the primary confining zone (Ironton Sandstone) and is used to support assessment of early-leak detection capabilities. Future updates of the model will be used to assess potential impacts on the lowermost underground source of drinking water (Saint Peter Sandstone) for a range of theoretical leakage scenarios. This preliminary modeling evaluation considers both pressure response and geochemical signals in the overlying Ironton Sandstone. This model is independent of the FutureGen 2.0 reservoir model in that it does not simulate caprock discontinuities, faults, or failure scenarios. Instead this modeling effort is based on theoretical, volumetric-rate based leakage scenarios. The scenarios include leakage of 1% of the total injected CO 2 mass, but spread out over different time periods (20, 100, and 500 years) with each case yielding a different mass flux (i.e., smaller mass fluxes for longer duration leakage cases]. A brine leakage scenario using a volumetric leakage similar to the 20 year 1% CO 2 case was also considered. A framework for the comparison of the various cases was developed based on the exceedance of selected pressure and geochemical thresholds at different distances from the point of leakage and at different vertical positions within the Ironton Sandstone. These preliminary results, and results from an updated models that incorporate additional site-specific characterization data, support development/refinement of the monitoring system design.

54 ENVIRONMENTAL SCIENCES↗

Modeling of time-lapse seismic monitoring using CO 2 leakage simulations for a model CO 2 storage site with realistic geology: Application in assessment of early leak-detection capabilities

Time-lapse surface seismic surveys have been widely used at carbon sequestration sites for site characterization, monitoring subsurface CO 2 plume migration, and detecting potential CO 2 leakage from a storage reservoir. Monitoring in the first permeable unit directly above the primary seal is important for early detection of CO 2 leakage. Forward modeling of time-lapse seismic data can be used to assess the utility of the seismic method for CO 2 leakage detection. We develop a workflow for forward modeling of time-lapse seismic data, including constructing seismic velocity models using flow simulation outputs, modeling of pre-stack and post-stack synthetic seismic data following seismic data processing sequence and analysis of processed synthetic time-lapse seismic data. We apply the forward modeling and analysis workflow to assessing the detectability and the earliest detection time of seismic monitoring using the hypothetical CO 2 leakage scenarios for a model geologic storage site with realistic geology. We then derive the detection thresholds using the simulated normalized root-mean-square (NRMS) differences for the no-leakage case at a range of signal-to-noise ratios, representing the background noise levels in seismic data. We then compare NRMS differences triggered by the CO 2 leakage to the detection thresholds at each time step to quantify the detectability and the earliest detection time of seismic monitoring. We analyze the effects of the acquisition parameters and elastic parameters on the produced synthetic seismic data and earliest detection time. Our modeling results indicate that high signal-to-noise ratio is needed to detect the CO 2 leakage at the model site. Minimizing the background noise in seismic data is crucial for improving the detectability of the seismic method. Increasing the shot density or increasing the dominant frequency of the source wavelet is likely to increase the possibility of the leakage detection and reduce the time needed for the detection. The elastic parameters used in the rock physics modeling have significant effects on the resultant seismic velocity models and synthetic seismic data, highlighting their critical roles in understanding and interpreting time-lapse seismic reflection data associated with CO 2 monitoring, verification and accounting activities.

58 GEOSCIENCES↗

Leakage From Coexisting Geologic Forcing and Injection‐Induced Pressurization: A Semi‐Analytical Solution for Multilayered Aquifers With Multiple Wells

Abstract Abnormal fluid pressures (above or below hydrostatic pressure) can develop and persist in sedimentary basins. The common occurrence of abnormal pressures may cause challenges for project permitting of geological carbon sequestration (GCS), particularly in reservoirs with pre‐injection overpressure. The leaky wells that may exist in some sedimentary basins can provide flow paths between deep brine aquifers and shallower freshwater aquifers. Pre‐injection relative overpressures can cause brine leakage through leaky wells even before any injection occurs. The tendency for flow through leaky wells is coupled with the process of pressure dissipation that occurs through aquitards. Specifically, with non‐zero permeability, aquitards can dissipate pressure over large areal extents and thereby reduce leakage rates through leaky wells. This study presents development of a semi‐analytical solution for hydraulic head and brine leakage in multilayered aquifer–aquitard systems with geologic pressure forcing. The geologic forcing that causes abnormal pressures in the multilayered system can coexist with any number of injection, extraction, and leaky wells that also affect fluid pressure. The semi‐analytical model is applied to explore how leakage through leaky wells varies as functions of pressurization rate, along with aquitard and leaky well properties in an overpressured multilayered system. The results show that although injection‐induced pressures can dissipate rapidly through suitably permeable aquitards, coexisting geologic forcing may create sustained rates of brine leakage into freshwater aquifers through leaky wells. In GCS, a very low‐permeability aquitard with high capillary entry pressure to free‐phase CO 2 is desired to serve as the caprock to prevent leakage of CO 2 from the storage reservoir. Nevertheless, the results from this study show that the brine leakage impact to shallow freshwater aquifers through leaky wells might substantially decrease with increasing aquitard permeability values, as long as small aquitard permeability and high capillary entry pressure serve to prevent CO 2 leakage.

Cihan, A.↗

Leakage Risk Assessment for a Potential CO 2 Storage Project in Saskatchewan, Canada

A CO 2 sequestration project is being considered to (1) capture CO 2 emissions from the Consumers Cooperative Refineries Limited at Regina, Saskatchewan and (2) geologically sequester the captured CO 2 locally in a deep saline aquifer. This project is a collaboration of several industrial and governmental organizations, including the Petroleum Technology Research Centre (PTRC), Sustainable Development Technology Canada (SDTC), SaskEnvironment Go Green Fund, SaskPower, CCRL, Schlumberger Carbon Services, and Enbridge. The project objective is to sequester 600 tonnes CO 2 /day. Injection is planned to start in 2012 or 2013 for a period of 25 years for a total storage of approximately 5.5 million tonnes CO 2 . This report presents an assessment of the leakage risk of the proposed project using a methodology known as the Certification Framework (CF). The CF is used for evaluating CO 2 leakage risk associated with geologic carbon sequestration (GCS), as well as brine leakage risk owing to displacement and pressurization of brine by the injected CO 2 . We follow the CF methodology by defining the entities (so-called Compartments) that could be impacted by CO 2 leakage, the CO 2 storage region, the potential for leakage along well and fault pathways, and the consequences of such leakage. An understanding of the likelihood and consequences of leakage forms the basis for understanding CO 2 leakage risk, and forms the basis for recommendations of additional data collection and analysis to increase confidence in the risk assessment.

02 PETROLEUM↗

Predicting Envelope Leakage in Attached Dwellings

The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting Envelope Leakage in Attached Dwellings

The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Land-use Leakage

Leakage occurs whenever actions to mitigate greenhouse gas emissions in one part of the world unleash countervailing forces elsewhere in the world so that reductions in global emissions are less than emissions mitigation in the mitigating region. While many researchers have examined the concept of industrial leakage, land-use policies can also result in leakage. We show that land-use leakage is potentially as large as or larger than industrial leakage. We identify two potential land-use leakage drivers, land-use policies and bioenergy. We distinguish between these two pathways and run numerical experiments for each. We also show that the land-use policy environment exerts a powerful influence on leakage and that under some policy designs leakage can be negative. International “offsets” are a potential mechanism to communicate emissions mitigation beyond the borders of emissions mitigating regions, but in a stabilization regime designed to limit radiative forcing to 3.7 2/m2, this also implies greater emissions mitigation commitments on the part of mitigating regions.

54 ENVIRONMENTAL SCIENCES↗

Low Leakage Valves for Long Duration Missions

I.Nomenclaturemtypical_mission=internal mass of propellant lost over the course of a mission with Qtypicalmmission_goal=mass of propellant loss over the course of a mission with Qgoaltmission=theoretical mission durationQtypical=internal leakage rate found in commercially available valvesQgoal=internal leakage rate design goalρH2_STP=density of hydrogen at standard temperature and pressure.1NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)2NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)3NASA AST, Liquid Propulsion Valve Engineer (Retired).Valves, Actuators, and Ducts Design and Development Branch (ER14)4JSEG ESSCA, Engineering Specialist.Valves Actuators and Ducts Design and Development Branch (ER14)5NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)6JSEG ESSCA, Valve Design and Development Engineer.Valves Actuators and Ducts Design and Development Branch (ER14) II.IntroductionCurrent aerospace cryogenic valves present challenges to potential long duration missions that utilize cryogenic propellants. Small interplanetary and long-life communication satellites typically utilize hypergolic propellants that operate at higher temperatures, making it easier to achieve very low internal leakage rates. Larger vehicles for long duration missions will likely need to utilize cryogenic-based chemical and nuclear systems to achieve mission requirements. Some early propulsion concepts are projected to require valves with a nominal size ranging from 3” to 10”.Currently available cryogenic aerospace valves typically have internal leakage rates which can range from 100 to 300 SCIM for 3” valves, or upwards of 2,000 SCIM for 10” valves. With just a few of these valves in a system, internal leakage could account for multiple tons of propellant loss over the course of a potential Mars mission, as shown in Figure 1.Figure 1 - Potential Propellant Loss Over the Course of a Long Duration MissionMost internal leakage rates can be attributed to inherent imperfections and misalignments, which result in imperfect contact between sealing surfaces, as shown in Figure 2.Figure 2 - Imperfections and Misalignments Between Sealing Surfaces The ER14 Branch at Marshall Space Flight Center (MSFC) has created a self-aligning seat and poppet design (shown in Figure 3) that allows a valve to be more tolerant of imperfect contacts. This design utilizes a metallic poppet head with five degrees of freedom that allows the poppet toself-align with the seat, reducing the need for tight tolerances.Figure 3 - Self-Aligning Seat and Poppet DesignIII.Test Valve DescriptionA series of development tasks have been conducted to study potential improvements to internal leakage rates. These tasks include 3 test valves (shown in Figure 4) to demonstrate the potential application to various configurations and sizes:A 3” isolation valve for liquid flows (similar to a fill and drain valve)A 3” relief valve for low temperature gas flows.An 8” pre-valve (similar to the engine isolation valve needed on a Nuclear Thermal Propulsion (NTP) engine).Figure 4 - Low Leakage Development Test ValvesThese valves have been developed and are currently being tested at liquid nitrogen (LN2) temperatures, and are anticipated to undergo testing at liquid hydrogen (LH2) temperatures in late 2022

Cody L Gilliland↗

Assessing hydrogen supply chains: An integrated review of leakage and energy efficiency studies

This paper examines hydrogen leakage and efficiency across the supply chain for liquid, gaseous, and mixed hydrogen systems. These factors are crucial for assessing hydrogen's role in mitigating emissions and facilitating a clean energy transition. Drawing on a comprehensive review of existing literature and model-based analysis, the study compiles leakage rates and efficiency metrics at each stage of the supply chain: production, storage, transmission, distribution, and end-use. These data inform system scenarios that estimate the impact of leakage on overall performance and climate benefits. The analysis also identifies persistent data gaps, particularly for liquid and mixed system configurations, and outlines priorities for future research. A comparison of hydrogen system types shows that gaseous pathways generally achieve the highest efficiencies (28 %–39 %) and the lowest leakage rates (∼4.5 %) across the supply chain. Liquid hydrogen systems, while favorable for long-distance and high-volume transport due to their higher energy density, exhibit lower efficiency (∼28 %) and a greater leakage potential (∼12 %). Mixed systems, which combine gaseous and liquid elements (e.g., pipeline transmission followed by liquefaction and truck distribution), show compounded energy losses and moderate-to-high leakage rates (6.8 %–9.4 %), highlighting trade-offs associated with added system complexity. The study highlights opportunities for technological advancements, including optimizing liquefaction, enhancing insulation for storage and transportation, and refining refueling equipment. These improvements are crucial for maximizing the climate benefits of hydrogen. The results offer actionable insights for researchers, industry, and policymakers working to develop low-leakage, high-efficiency hydrogen infrastructure.

08 HYDROGEN↗

Underground sources of drinking water chemistry changes in response to potential CO 2 leakage

The purpose of this study was to quantify changes to underground sources of drinking water (USDW) quality in response to potential CO 2 leakage from geologic CO 2 sequestration (GCS) reservoirs. Here, the developed a framework of combined laboratory experiments and reactive transport simulations and used this framework to evaluate the Ogallala aquifer overlying the Farnsworth Unit (FWU), an active GCS site, as a case study. Using chemical reaction parameters obtained from laboratory experiments and numerical simulations, site-specific mechanisms of CO 2 -water-sediment interactions at the USDW aquifer were interpreted. Long-term risks of potential CO 2 leakage were then evaluated with field-scale numerical models using the regional hydrogeological characteristics and reaction parameters obtained from our experiments and simulations. Results suggest that carbonate mineral impurity and cation exchange are key mechanisms for interactions between CO 2 and the aquifer sediment. Additionally, for a large leakage rate of 0.1 % injection from one leaky well, the leakage plume might impact an area of 300 m in diameter and significantly affect the local water quality by changing pH and cation concentrations (e.g., Zn, Ba and Sr). After leakage ceases, the zone of impacted fluids would not migrate significantly in subsequent decades due to a low regional groundwater flowrate (for this case study). The relatively small area of impact might not be detected in a monitoring well given the broader spacing in a typical field scenario. Effective early leakage detection may require additional tools, e.g., borehole CO 2 movement, four-dimensional seismicity, CO 2 soil flux, samples from deeper aquifers, etc., to ensure effective leakage detection and long-term safety of GCS projects.

58 GEOSCIENCES↗

Low dislocation density InAlN/AlN/GaN heterostructures grown on GaN substrates and the effects on gate leakage characteristics

This paper reports on the electrical characterization of Ni/Au Schottky diodes fabricated on InAlN high-electron-mobility transistor (HEMT) structures grown on low dislocation density free-standing GaN substrates. InAlN HEMT structures were grown on sapphire and GaN substrates by metal-organic vapor phase epitaxy, and the effects of threading dislocation density on the leakage characteristics of Ni/Au Schottky diodes were investigated. Threading dislocation densities were determined to be 1.8 × 10{sup 4 }cm{sup −2} and 1.2 × 10{sup 9 }cm{sup −2} by the cathodoluminescence measurement for the HEMT structures grown on GaN and sapphire substrates, respectively. Leakage characteristics of Ni/Au Schottky diodes were compared between the two samples, and a reduction of the leakage current of about three to four orders of magnitude was observed in the forward bias region. For the high reverse bias region, however, no significant improvement was confirmed. We believe that the leakage current in the low bias region is governed by a dislocation-related Frenkel–Poole emission, and the leakage current in the high reverse bias region originates from field emission due to the large internal electric field in the InAlN barrier layer. Our results demonstrated that the reduction of dislocation density is effective in reducing leakage current in the low bias region. At the same time, it was also revealed that another approach will be needed, for instance, band modulation by impurity doping and insertion of insulating layers beneath the gate electrodes for a substantial reduction of the gate leakage current.

36 MATERIALS SCIENCE↗

Low leakage current in heteroepitaxial Al 0.7 Sc 0.3 N ferroelectric films on Ga N

Wurtzite ( Al , Sc ) N ferroelectrics are attractive for microelectronics applications due to their chemical and structural compatibility with wurtzite semiconductors, such as Ga N and ( Al , Ga ) N . However, the leakage current in epitaxial stacks reported to date should be reduced for reliable device operation. Here, we demonstrate low leakage current in epitaxial Al 0.7 Sc 0.3 N films on Ga N with well-saturated ferroelectric hysteresis loops that are orders of magnitude lower (i.e., 0.07 A cm − 2 ) than previously reported films (1–19 A cm − 2 ) having similar or better structural characteristics. We also show that, for these high-quality epitaxial ( Al , Sc ) N films, structural quality (edge and screw dislocations), as measured by diffraction techniques, is not the dominant contributor to leakage. Instead, the small leakage in our films is limited by thermionic emission across the interfaces, which is distinct from the large leakage due to trap-mediated bulk transport in the previously reported ( Al , Sc ) N films. To support this conclusion, we show that Al 0.7 Sc 0.3 N on lattice-matched In 0.18 Ga 0.82 N buffers with improved structural characteristics but higher interface roughness exhibit increased leakage characteristics. This demonstration of low leakage current in heteroepitaxial ( Al , Sc ) N films and understanding of the importance of interface barrier and surface roughness can guide further efforts toward improving the reliability of wurtzite ferroelectric devices. Published by the American Physical Society 2025

36 MATERIALS SCIENCE↗

Assessment of Multiple Monitoring Methods for Detection of Brine and CO2 Leakage

We assess the effectiveness of four surface-based geophysical methods and in situ monitoring of pressure and chemical changes for detecting brine and CO2 leakage from legacy wells into underground sources of drinking water (USDW) overlying a CO2 storage reservoir. This is the first such effort to evaluate and compare six monitoring methods for detection of CO2 leakage. This assessment, conducted in support of the USDOE National Risk Assessment Partnership (NRAP), utilizes 3000 synthetic data sets, generated in an uncertainty quantification (UQ) model framework. This framework combines the results of (1) a CO2 storage reservoir model of a hypothetical storage operation of 5 MT/yr for 50 years into the 1700-m deep Vedder Fm. at a site near Kimberlina, California with (2) wellbore leakage models of a legacy well and (3) multi-phase flow and reactive transport models of brine and CO2 plume migration in aquifer layers overlying the storage reservoir. Leakage drives subsurface changes, quantified by pressure plumes, CO2-saturation plumes, and total dissolved solids (TDS) plumes, the latter being related to changes in pH and species concentrations. Depending on the depth of leakage, aquifer permeability, and regional groundwater gradient, pressure plume volumes can become larger than the CO2 and TDS plumes; however, reaching detectable thresholds may take too long to be useful. For a single monitoring well located 500 m downgradient of a leaky legacy well, a depth of 570 m is found to be optimal for sampling pressure and chemical changes. We assess four surface-based geophysical monitoring methods: electrical resistivity tomography (ERT), magnetotellurics (MT), gravity, and seismic methods. Sensors cover a 4-km × 2-km area. Both ERT and MT methods are sensitive to changes in CO2 saturation and TDS concentration, whereas gravity and seismic methods detect changes in CO2 saturation. The six monitoring methods complement each other in space and time, and we find that a minimum of 20 kT of CO2 leakage is required for the leakage plume to be detected. Of the four surface-based geophysical methods, gravity monitoring appears to be the most sensitive to CO2 leaks, while the usefulness of in situ pressure and chemical monitoring will depend on the level of unfilterable background noise. Geophysical monitoring methods may detect a leak anywhere in a large area and in a large depth range, but the effectiveness of pressure and chemical monitoring depends on the number of monitoring wells, where those wells are located, and the depth of sampling. Surface-based geophysical monitoring methods are cost-effective alternatives to in situ pressure and chemical monitoring methods.

NRAP, CCS, monitoring, geophysical methods, gravit↗

Using distributed temperature sensing to detect CO 2 leakage along the injection well casing

The objective of this study is to evaluate the sensitivity of Distributed Temperature Sensing (DTS) data to detect CO 2 leakage along an injection well casing. This paper describes the relationship between the CO 2 leakage rate and temperature response at DTS locations, and the method and numerical model used for understanding such a relationship. The uncertainties in the parameters are propagated to the interpretation of DTS measurements, which may lead to false positive and false negative identifications of CO 2 leakage. We propose to identify CO 2 leakage by analyzing both temperature history plots at selected vertical locations as well as the vertical temperature profiles at different times. The analysis should be combined with numerical simulations for the estimation of leakage rates. In addition, leakage needs to be confirmed by data from a warm-up test (temperature recovery after injection of cold CO 2 is stopped) to minimize the probability of false identifications.

42 ENGINEERING↗

Cobalt chloride attenuates hypobaric hypoxia induced vascular leakage in rat brain: Molecular mechanisms of action of cobalt chloride

This study reports the efficacy of cobalt preconditioning in preventing hypobaric hypoxia induced vascular leakage (an indicator of cerebral edema) using male Sprague-Dawley rats as model system. Exposure of animals to hypobaric hypoxia led to a significant increase in vascular leakage, reactive oxygen species (ROS), nitric oxide (NO), and vascular endothelial growth factor (VEGF) levels. There was a marked increase in Nuclear Factor {kappa}B (NF{kappa}B) DNA binding activity and levels of pro-inflammatory cytokines such as Monocyte chemoattractant protein (MCP-1), Interferon-{gamma} (IFN-{gamma}), Interleukin-1 (IL-1), and Tumor Necrosis Factor-{alpha} (TNF-{alpha}) and cell adhesion molecules such as Vascular Cell Adhesion Molecule-1 (VCAM-1), and P-selectin. Chemical preconditioning by cobalt for 7 days (12.5 mg Co/kg b.w., oral) significantly attenuated cerebral vascular leakage and the expression of inflammatory mediators induced by hypoxia. Administration of NF{kappa}B inhibitor, curcumin (50 mg/kg b.w.; i.p.) appreciably inhibited hypoxia induced vascular leakage indicating the involvement of NF{kappa}B in causing vascular leakage. Interestingly, cobalt when administered at 12.5 mg Co/kg b.w. (i.p.), 1 h before hypoxia could not prevent the vascular leakage indicating that cobalt per se did not have an effect on NF{kappa}B. The lower levels of NF{kappa}B observed in the brains of cobalt administered animals might be due to higher levels of antioxidant and anti-inflammatory proteins (hemeoxygenase-1 and metallothionein). To conclude cobalt preconditioning inhibited hypobaric hypoxia induced cerebral vascular leakage by lowering NF{kappa}B DNA binding activity and its regulated pro-inflammatory mediators. This is contemplated to be mediated by cobalt induced reduction in ROS/NO and increase in HO-1 and MT.

60 APPLIED LIFE SCIENCES↗

Localized divertor leakage measurements using isotopic tungsten sources during edge-localized mode-y H-mode discharges on DIII-D

Experiments carried out on DIII-D using a novel setup of isotopic tungsten (W) sources in the outer divertor have characterized how the W leakage from this region depends on both the exact source location and edge-localized mode (ELM) behavior. The sources are toroidally-symmetric and poloidally-localized to two regions: (1) the outer strike point (OSP) with natural abundance of W isotopes; and (2) the far-target with highly-enriched 182 W isotopes. With the use of a dual-faced collector probe (CP) in the main scrape-off layer (SOL) near the outside midplane and source-rate spectroscopy, a proxy for divertor impurity leakage is developed herein. Using this proxy, it is found that for the OSP W location, there is a nearly linear increase of leakage with the power across the separatrix ( ), which is consistent with the effect of an increased upstream ion temperature parallel gradient force in the near-SOL; trends in the pedestal density and collisionality are also seen. Conversely, it is found that for the far-target W location leakage falls off rapidly as increases and ELM size decreases, which is suggestive that ELM size plays a role in the leakage from this location. Indications for main SOL W contamination is evidenced by the measurement of large deposition asymmetries on the two opposite CP faces. These measurements are coupled with interpretive modeling showing SOL W accumulation near the separatrix furthest from both targets driven by forces parallel to the magnetic field. This experimental setup, together with the target and upstream W measurements, provides information on the transport from different divertor W source locations and leakage. These studies help to elucidate the physics driving divertor impurity source rates and leakage, with and without ELMs, and provide better insight on the link in the chain connecting wall impurity sources to core impurity levels in magnetic fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗