Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEAD 192”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

64 records · Page 4

Ultra heavy cosmic ray experiment (A0178)

The Ultra Heavy Cosmic Ray Experiment (UHCRE) is based on a modular array of 192 side viewing solid state nuclear track detector stacks. These stacks were mounted in sets of four in 48 pressure vessels using 16 peripheral LDEF trays. The geometry factor for high energy cosmic ray nuclei, allowing for Earth shadowing, was 30 sq m sr, giving a total exposure factor of 170 sq m sr y at an orbital inclination of 28.4 degs. Scanning results indicate that about 3000 cosmic ray nuclei in the charge region with Z greater than 65 were collected. This sample is more than ten times the current world data in the field (taken to be the data set from the HEAO-3 mission plus that from the Ariel-6 mission) and is sufficient to provide the world's first statistically significant sample of actinide cosmic rays. Results are presented including a sample of ultra heavy cosmic ray nuclei, analysis of pre-flight and post-flight calibration events and details of track response in the context of detector temperature history. The integrated effect of all temperature and age related latent track variations cause a maximum charge shift of + or - 0.8e for uranium and + or - 0.6e for the platinum-lead group. Astrophysical implications of the UHCRE charge spectrum are discussed.

Thompson, A.↗

Progress report on the ultra heavy cosmic ray experiment (AO178)

The Ultra Heavy Cosmic Ray Experiment (UHCRE) is based on a modular array of 192 side-viewing solid state nuclear track detector stacks. These stacks were mounted in sets of four in 48 pressure vessels employing sixteen peripheral Long Duration Exposure Facility (LDEF) trays. The extended duration of the LDEF mission has resulted in a greatly enhanced scientific yield from the UHCRE. The geometry factor for high energy cosmic ray nuclei, allowing for Earth shadowing, was 30 sq m-sr, giving a total exposure factor of 170 sq m-sr-y at an orbital inclination of 28.4 degrees. Scanning results indicate that about 3000 cosmic ray nuclei in the charge region with Z greater than 65 were collected. This sample is more than ten times the current world data in the field (taken to be the data set from the HEAO-3 mission plus that from the Ariel-6 mission) and is sufficient to provide the world's first statistically significant sample of actinide (Z greater than 88) cosmic rays. Results to date are presented including details of ultra-heavy cosmic ray nuclei, analysis of pre-flight and post-flight calibration events and details of track response in the context of detector temperature history. The integrated effect of all temperature and age related latent track variations cause a maximum charge shift of +/- 0.8 e for uranium and +/- 0.6 e for the platinum-lead group. The precision of charge assignment as a function of energy is derived and evidence for remarkably good charge resolution achieved in the UHCRE is considered. Astrophysical implications of the UHCRE charge spectrum are discussed.

Thompson, A.↗

SU-F-I-56: High-Precision Gamma-Ray Analysis of Medical Isotopes

Purpose: Advanced, time-resolved, Compton-suppressed gamma-ray spectroscopy with germanium detectors is implemented for assaying medical isotopes to study the radioactive decay process leading to a more accurate appraisal of the received dose and treatment planning. Lowell’s Array for Radiological Assay (LARA), a detector array that is comprised of six Compton-suppressed high-purity germanium detectors, is currently under development at UMass-Lowell which combines Compton-suppression and time-and-angle correlations to allow for highly efficient and highly sensitive measurements. Methods: Two isotopes produced Brookhaven Linac Isotope Producer (BLIP) were investigated. {sup 82}Sr which is the parent isotope for producing {sup 82}Rb is often used in cardiac PET. {sup 82}Sr gamma-ray spectrum is dominated by the 511keV photons from positron annihilation which prevent precise measurement of co-produced contaminant isotopes. A second project was to investigate the production of platinum isotopes. Natural platinum was bombarded with protons from 53MeV to 200MeV. The resulting spectrum was complicated due to the large number of stable platinum isotopes in the target, the variety of open reaction channels (p,xn), (p,pxn), (p,axn). Results: By using face-to-face NaI(Tl) counters 90-degrees to the Compton-suppressed germaniums to detect the 511keV photons, a much cleaner and more sensitive measurement of {sup 85}Sr and other contaminants was obtained. For the platinum target, we identified the production of {sup 188–189–191–195}Pt, {sup 191–192–193–194–195–196}Au and {sup 186–188–189–190–192–194–189–190–192–194}Ir. For example, at the lower energies (53 and 65MeV), we measured {sup 191}Pt production cross-sections of 144mb and 157mb. Considerable care was needed in following the process of dissolving and diluting the samples to get consistent results. The new LARA array will help us better ascertain the absolute efficiency of the counting system and more reliable production cross-sections. Conclusion: Modern HPGe spectroscopic techniques provide enhanced sensitivity, promising precise quantification of the quality of radioisotopes used in medical physics. Using new decay information may have non-trivial impact on treatment planning and dose-assessment.

07 ISOTOPE AND RADIATION SOURCES↗

Predicting Cancer Risk from Ionizing Radiation

The ability to predict cancer risk associated with exposure to low doses of high-LET ionizing radiation (IR) remains a challenge. Epidemiological methods lack the sensitivity and power to provide detailed risk estimates for cancer and ignore individual variance in IR sensitivity. We have hypothesized that DNA repair capacity can be used as a marker to evaluate and differentiate individual radiation sensitivity. More specifically, this work is based on the concept that the combined time-dose dependence of radiation-induced foci (RIF) of p53-binding protein 1 (53BP1) following low-LET exposure contains sufficient information to infer sensitivity to any other LET. Our hypothesis was tested in 15 different mouse strains as well as in primary human immune cells. We first approached individual ionizing radiation sensitivity in a mouse model by culturing primary skin fibroblasts extracted from 76 mice of 15 different genetic backgrounds and exposing them to HZE particles and X-rays. This work is one of the most extensive studies on the kinetics and possible genetic underpinnings of radiation-induced DNA damage and repair. Our results is in agreement with a DNA repair model we previously postulated, where nearby DNA double strand breaks (DSB) in the nucleus are brought together for more efficient repair, leading to RIF clustering. Such mechanism was evidenced by a specific dose and LET dependence of RIF numbers. Briefly, RIF quantification after low-LET X-ray exposure showed an asymptotic saturation for doses between 1 Gy and 4 Gy 4 hours post-irradiation across all 15 strains. The clustering of DSB across all strains also led to more RIF/Gy for lower LET (X-ray and 350 MeV/n Ar) than for higher LET (600 MeV/n Fe) 4 hours post-exposure. Considering the fact that the number of DSB/Gy should be independent of LET, our data suggest there are more DSB in individual RIF as the LET increases. RIF numbers for 24 and 48 hours post-exposure led to the inverse trend, with more remaining RIF/Gy for higher LET (by 600 MeV/n Fe). This result suggests cells have more difficulty resolving RIF from higher LET as they the number DSB/RIF increases. Note that for most conditions, the variance of RIF/Gy was small within individual animals of the same strain and large between strains, suggesting a strong genetics component. Furthermore, we present our preliminary data from an ongoing study on human genetic associations with IR sensitivity. To address the human variability in responses to HZE particle irradiation in a maximally comprehensive manner, we are in the process of collecting and isolating primary blood mononuclear cells from 768 healthy subjects of European descent, 18-75 years of age, 50/50 male/female distribution. We have analyzed 53BP1+ RIF formation as well as oxidative stress and cell death in primary cells from 192 subjects in response to the same HZE particles as used in mice: 600 MeV/n Fe, 350 MeV/n Ar and 350 MeV/n Si, 1.1 and 3 particles/100m2, 4 and 24 hours after irradiation. We will next complete the quantification of HZE particle-induced DNA and cellular damage in the remaining subjects and compare it to their responses to low-LET irradiation. Finally, we will perform GWAS analysis to identify human genomic associations with IR sensitivity and potential targets for biomarker development.

High-LET radiation↗

Comparison of Geant4-DNA and RITRACKS/RITCARD: Microdosimetry, Nanodosimetry and DNA Damage Predictions for Low to High LET Ions

Low linear energy transfer (LET) ionizing radiations induce homogeneously distributed DNA damage at the cellular scale, while high LET ionizing radiations are well known to create complex biological damage including clustered double strand breaks (DSB). Clustered DSB are critical events that are difficult to repair, leading to increased biological outcomes compared to low LET radiation exposure. Recent studies have shown that DNA compaction, which can be actively modified by the cell to allow DNA repair, influences the yield of DSB [1]. The goal of this work is to determine the impact of DNA compaction on chromosome aberration formation, a biomarker of radiation-induced cancer risk. The RITRACKS track structure code [2], together with the RITCARD code [3], allow one to simulate the transport of high LET ions, calculate DNA damage and repair, and chromosome aberration formation, but does not include detailed geometrical models of DNA. The Geant4-DNA toolkit provides such detailed models with different levels of DNA compaction [1,4], but does not model chromosome aberration formation. In this work, these highly detailed DNA geometries are used to compute DNA breaks with Geant4-DNA and combine the results with the RITCARD tool to compute chromosome aberrations. As a first step, we compared the transport models used in RITRACKS and Geant4-DNA and newly released heavy ion model transport (G4DNARuddIonisationExtendedModel Geant4 v11.2) to ensure consistency between the physical stage of the two radiation transport codes. We compared energy deposition at the micrometric and nanometric scales for different ions (H 250 MeV, H 150 Me, He 250 MeV/n, C 290 MeV/n, O 350 MeV/n, O 55 MeV/n, Si 170MeV/n, Ti 300 MeV/n, Ti 300 MeV/n, Fe 600 MeV/n, Fe 450 MeV/n and Fe 300 MeV/n) with LET ranging from ~0.4 keV/μm up to 235 keV/μm. Excellent agreement is found for both microdosimetric and nanodosimetric spectra for all ion types and energies. The calculation of DNA breaks and their complexity with the Geant4-DNA is an ongoing work, and comparison with RITCARD will be presented based on result availability at the time of the conference. [1] Tang et al. (2019). Med. Phys., 46(3), 1501-1511. [2] Plante et al. (2008). NJP, 10(12), 125020. [3] Plante et al. (2019). Rad. Res., 192(3), 282-298. [4] Incerti et al. (2018). Med. Phys., 45(8), e722-e739.

Floriane Poignant↗

SU-F-T-30: Comprehensive Dosimetric Characterization of the Novel Direction Modulation Brachytherapy (DMBT) Tandem Applicator Using Monte Carlo Simulations

Purpose: To characterize the dosimetric properties/distributions of the novel proposed direction modulated brachytherapy (DMBT) tandem applicator in combination with 192Ir HDR source, and compare against conventional tandem design, using Monte Carlo simulations. Methods: The proposed DMBT tandem applicator is designed for image-guided adaptive brachytherapy, especially MRI, of cervical cancer. It has 6 peripheral holes of 1.3-mm width, grooved along a 5.4-mm diameter nonmagnetic tungsten alloy rod of density 18.0 g/cc, capable of generating directional dose profiles – leading to enhanced dose sculpting capacity through inverse planning. In-water dosimetric parameters for the DMBT and conventional tandems have been calculated for various radial distances away and around the tandems. For the DMBT tandem, the cumulative dose from the 192Ir source occupying 1) one and 2) all six holes in equal dwell times was calculated and normalized to match the dose rate of the open source (in conventional tandem) at 1 cm from the center. This is done to compare and contrast the characteristic dose distributions to that of the isotropic TG43-based 192Ir source. Results: All dose rates were normalized at 1-cm radius from the center of the applicators, containing source(s). The normalized dose rates at 0.5, 3.0, and 5.0-cm radiuses were then 388, 11.3, and 4.1% for conventional tandem, 657, 8.1, and 2.7% for DMBT tandem with the source in one hole at front entrance, and 436, 10.9, and 3.8% for DMBT tandem with the source in all six holes. For the DMBT tandem case with the source in one hole, the backside transmissions were 47, 2.4, and 0.9%, respectively. Conclusion: The DMBT tandem is able to generate closely similar dosimetric characteristics as that of the single-channel conventional tandem if needed (with the source occupying all six holes), at the same time, generate directional radiation profile(s) for favorably enabling 3D dose sculpting capability.

60 APPLIED LIFE SCIENCES↗

WE-DE-201-03: Combined Use of 192Ir, 60Co, and 169Yb Sources with the Novel Direction Modulated Brachytherapy Tandem Applicator for High Dose Rate Brachytherapy Planning of Cervical Cancer

Purpose: To evaluate the improvement in plan quality when various combinations of 192Ir, 60Co, and 169Yb sources are used in combination with a novel direction modulated brachytherapy (DMBT) tandem applicator for high dose rate brachytherapy of cervical cancer. Methods: The proposed DMBT tandem applicator is designed for image-guided adaptive brachytherapy (IGABT), especially MRI, of cervical cancer. It has 6 peripheral holes of 1.3-mm width, grooved along a 5.4-mm diameter nonmagnetic tungsten alloy rod of density 18.0 g/cc, capable of generating directional dose profiles - leading to enhanced dose sculpting capacity through inverse planning. Monte Carlo simulations of the three HDR sources individually inside the DMBT applicator were performed and imported into an in-house developed inverse optimization code. We then performed inverse planning with 14 cervical cancer patients enrolled in EMBRACE study. In all patients, 3D MRI-based planning was performed while utilizing 1) tandem-ring and needles attached-to-ring (7 patients) and 2) tandem-ring and needles both attached-to-ring and free-hand-loaded (7 patients), in accordance with the GEC-ESTRO recommendations. All plans were normalized to receive the same HRCTV D90 and DVH parameters were evaluated. Results: The DMBT tandem was used in all cases. Overall, the combined use of two sources (192Ir-60Co and 192Ir-169Yb, but not 60Co-169Yb) generally produced better quality plans than with the 192Ir source alone in terms of sparing OARs. For example, up to 3.5, 4.4, and 3.9% individual reductions in D2cc were observed for the bladder, rectum, and sigmoid, respectively, between 192Ir-60Co and 192Ir-only plans for patient cases in #1. While up to 5.5, 2.0, and 5.7% individual reductions were observed for patient cases in #2. Conclusion: We have demonstrated that, in addition to “directional modulation” of DMBT, use of multiple sources with sufficient differences in energy can be utilized to achieve additional improvement in plan quality for IGABT of cervical cancer.

60 APPLIED LIFE SCIENCES↗

SU-E-T-375: Evaluation of a MapCHECK2(tm) Planar 2-D Diode Array for High-Dose-Rate Brachytherapy Treatment Delivery Verifications

Purpose: Despite improvements of HDR brachytherapy delivery systems, verification of source position is still typically based on the length of the wire reeled out relative to the parked position. Yet, the majority of errors leading to medical events in HDR treatments continue to be classified as missed targets or wrong treatment sites. We investigate the feasibility of using dose maps acquired with a two-dimensional diode array to independently verify the source locations, dwell times, and dose during an HDR treatment. Methods: Custom correction factors were integrated into frame-by-frame raw counts recorded for a Varian VariSource™ HDR afterloader Ir-192 source located at various distances in air and in solid water from a MapCHECK2™ diode array. The resultant corrected counts were analyzed to determine the dwell position locations and doses delivered. The local maxima of polynomial equations fitted to the extracted dwell dose profiles provided the X and Y coordinates while the distance to the source was determined from evaluation of the full width at half maximum (FWHM). To verify the approach, the experiment was repeated as the source was moved through dwell positions at various distances along an inclined plane, mimicking a vaginal cylinder treatment. Results: Dose map analysis was utilized to provide the coordinates of the source and dose delivered over each dwell position. The accuracy in determining source dwell positions was found to be +/−1.0 mm of the preset values, and doses within +/−3% of those calculated by the BrachyVision™ treatment planning system for all measured distances. Conclusion: Frame-by-frame data furnished by a 2 -D diode array can be used to verify the dwell positions and doses delivered by the HDR source over the course of treatment. Our studies have verified that measurements provided by the MapCHECK2™ can be used as a routine QA tool for HDR treatment delivery verification.

60 APPLIED LIFE SCIENCES↗

TH-CD-201-01: BEST IN PHYSICS (THERAPY): Assessment of Thin-Film CdTe as An Effective Detector for Microdosimety at Gold-Tissue Interface

Purpose: Presence of interfaces between high and low atomic number materials, often encountered in diagnostic imaging and radiation therapy, leads to radiation dose perturbation. This phenomenon is characterized by a very narrow region of sharp dose enhancement at the interface. The rapid fall-off of the dose enhancement over a very short distance from the interface makes the experimental dosimetry nontrivial. We use an in-house-built inexpensive thin-film Cadmium Telluride (CdTe) photodetector to study this effect at the gold-tissue interface and verify our experimental results with Monte Carlo (MC) modeling. Methods: Three micron thick CdTe photodetectors were fabricated in our lab. One, ten or one hundred micron thick gold foils placed in a tissue-equivalent-phantom were irradiated with a clinical Ir-192 high dose rate source and current measured with a CdTe detector in each case was compared against the current measured for all uniform tissue-equivalent phantom. Percentage signal enhancement (PSE) due to each gold foil was compared against MC modeled percentage dose enhancement (PDE), obtained from the geometry mimicking the experimental setup. Results: The experiment based PSEs due to 1, 10, and 100 micron thick gold foils at the closest measured distance of measurement (12.5 micron) from the interface were 42.6 ± 10.8, 137.0 ± 11.9 and 203.0 ± 15.4 respectively. The corresponding MC modeled PDEs were 38.1 ± 1, 164 ± 1 and 249 ± 1 respectively. The experimental and MC modeled values showed a closer agreement at the larger distances from the interface. Conclusion: The dose enhancement near the gold-tissue interface was measured using an in-house-built high-resolution CdTe-based photodetector and validated with MC simulations. A close agreement of the experimental results with the corresponding MC modeled results shows that CdTe detector can be utilized for mapping interface dose distribution encountered in the application of ionizing radiation.

60 APPLIED LIFE SCIENCES↗

Constraining gas motion and non-thermal pressure beyond the core of the Abell 2029 galaxy cluster with XRISM

We report on a detailed spectroscopic study of the gas dynamics and hydrostatic mass bias of the galaxy cluster Abell 2029, utilizing high-resolution observations from XRISM Resolve. Abell 2029, known for its cool core and relaxed X-ray morphology, provides an excellent opportunity to investigate the influence of gas motions beyond the central region. Expanding upon prior studies that revealed low turbulence and bulk motions within the core, our analysis covers regions out to the scale radius $R_{2500}$ (670 kpc) based on three radial pointings extending from the cluster center toward the northern side. We obtain accurate measurements of bulk and turbulent velocities along the line of sight. The results indicate that non-thermal pressure accounts for no more than 2% of the total pressure at all radii, with a gradual decrease outward. The observed radial trend differs from many numerical simulations, which often predict an increase in non-thermal pressure fraction at larger radii. These findings suggest that deviations from hydrostatic equilibrium are small, leading to a hydrostatic mass bias of around 2% across the observed area.

X-rays: galaxies: clusters↗