Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LASER SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

CORONIUM IN THE LABORATORY: MEASURING THE Fe XIV GREEN CORONAL LINE BY LASER SPECTROSCOPY

The green coronal line at 530.3 nm was first observed during the total solar eclipse of 1869. Once identified as emitted by Fe XIV, it became clear that this highly charged ion was typical for the range of temperatures found in coronal plasmas, stellar winds, outflows, and accretion disks. Under these conditions of high ionization, the strongest transitions are in the X-ray, extreme ultraviolet, and ultraviolet wavelength range, with only few optical lines. For these so-called forbidden coronal lines, only scarce laboratory data is available, and even advanced atomic theory codes cannot yet predict their wavelengths with the accuracy required for precise absolute velocity determinations of such plasmas. Here we report on a study of the Fe XIV line, a key coronal transition of a highly charged ion, using laser spectroscopy in an electron beam ion trap, obtaining the first laboratory measurement of 530.2801(4) nm for its rest wavelength. The result enables the determination of absolute line shifts and line broadenings in hot turbulent plasmas and astrophysical environments, with an error bar of only 0.24 km s{sup –1}. In addition, our measurement provides a much-needed benchmark for advanced atomic structure calculations, which are fundamental for astronomy.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser spectroscopy of metastable palladium at 340 and 363 nm

Here we report measurements of the isotope shift of the mass 104, 105, 106, 108, and 110 stable palladium isotopes for transitions from the metastable state $4d^9(^2D_{5/2})5s$, $^2[5/2]_3 → 4d^9(^2D_{5/2})5p, ^2[7/2]^o_4$ at 340 nm, and $4d^9(^2D_{5/2})5_s, ^2[5/2]_3 → 4d^9(^2D_{5/2})5p, ^2[3/2]^o_2$ at 363 nm. For 105 Pd , we determine the hyperfine structure of both transitions. The measurements were performed by saturation absorption spectroscopy in a custom-built hollow cathode lamp and will serve as a reference for collinear laser spectroscopy of short-lived neutron-rich palladium isotopes. We also report on the observation of a population inversion for the 363-nm transition under certain discharge conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Instantaneous Three-Dimensional Temperature Measurements via Ultrafast Laser Spectroscopy with Structured Light

Detonations and flames are characterized by three-dimensional (3D) temperature fields, yet state-of- the-art temperature measurement techniques yield information at a point or along a line. The goal of the research documented here was to combine ultrafast laser spectroscopy and structured illumination to deliver an unprecedented measurement capability—three-dimensional, instantaneous temperature measurements in a gas-phase volume. To achieve this objective, different parts of the proposed technique were developed and tested independently. Structured illumination was used to image particulate matter (soot) in a turbulent flame at multiple planes using a single laser pulse and a single camera. Emission spectroscopy with structured detection was demonstrated for emission- based measurements of explosives with enhance dimensionality. Finally, an instrument for multi- planar laser-based temperature measurement technique was developed. Structured illumination techniques will continue to be developed for multi-dimensional and multi-parameter measurements. These new measurement capabilities will be important for heat transfer and fluid dynamic research areas.

42 ENGINEERING↗

An experiment concept to measure stratospheric trace constituents by laser heterodyne spectroscopy

Laser heterodyne spectroscopy (LHS) techniques were used to measure radical gases from Spacelab. Major emphasis was placed on the measurement of ClO, ClOnO2, HO2, H2O2, N2O5, and HOCl in solar occultation with vertical resolution less than or equal to 2-km and vertical range from 1O to 70-km. Sensitivity analyses were performed on ClO and O3 to determine design criteria for the LHS instrument. Results indicate that O3 and ClO vertical profiles can be measured with an accuracy more than or equal to 95% and more than or equal to 80%, respectively, over the total profile.

Allario, F.↗

Note: Micro-channel array crucible for isotope-resolved laser spectroscopy of high-temperature atomic beams

Here, we present a novel compact design for a multichannel atomic oven which generates collimated beams of refractory atoms for fieldable laser spectroscopy. Using this resistively heated crucible, we demonstrate spectroscopy of an erbium sample at 1300 °C with improved isotopic resolution with respect to a single-channel design. In addition, our oven has a high thermal efficiency. By minimizing the surface area of the crucible, we achieve 2000 °C at 140 W of applied electrical power. As a result, the design does not require any active cooling and is compact enough to allow for its incorporation into fieldable instruments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stable isotope laser spectroscopy

Recent advances in semiconductor laser technology have produced a reliable lightweight device ideally suited for a spacecraft high resolution molecular spectrometer. Lead-salt tunable diode lasers (TDL) emit in several spectral modes, each with a very narrow linewidth of -0.0003/cm. This spectral resolution is much narrower than typical Doppler broadened molecular linewidths in the mid-IR range. Thus it is possible to detect individual rotational lines within the vibrational band and measure their intensity, which can be used to determine gas concentration. The narrow spectral lines of any impurity gas tend to lie between the narrow lines of the gas of interest. This represents a major advantage over the accepted gas chromatograph mass spectrometer (GCMS) technique for measuring gas concentrations and isotope ratios. The careful and extensive gas purification procedures required to remove impurities for reliable GCMS measurements will not be required for an IR laser gas analysis. The infrared laser gas analysis technique is being developed to measure stable isotopic ratios of gases such as CO2, CH4, N2O, and NH3. This will eventually lead to development of instruments capable of in situ istopic measurements on planets such as Mars. The carbon (C-12, C-13) isotope ratio is indicative of the type of carbon fixation mechanisms (e.g., photosynthesis, respiration) in operation on a planet, while the nitrogen (N-14, N-15) isotope ratio can probably be used to date nitrogen-bearing Martian samples. The absorbance ratio of two adjacent lines of CO2 in the 2300/cm (4.3 micron) region of the spectrum was measured. The precision of the measurement is presently better than 1 percent and significant improvement is anticipated as rapid sweep-integration techniques and computer controlled data acquistion capabilities are incorporated.

Becker, J. F.↗

Infrared laser spectroscopy of jet-cooled carbon clusters - The bending dynamics of linear C9

We report improved measurements for the nu6 antisymmetric stretch fundamental and observation of the (nu6 + nu15) - nu15 and (nu6 + 2nu15) - 2nu15 hot bands of the linear C9 carbon cluster by direct absorption diode laser spectroscopy of a supersonic carbon cluster beam. Analysis of these bands characterizes C9 as a semirigid molecule with a bending potential similar to that of C5 and further evidences the alternation in degree of rigidity of linear carbon clusters with the g-u symmetry of the HOMO.

Van Orden, A.↗

Laser Spectroscopy of Niobium Fission Fragments: First Use of Optical Pumping in an Ion Beam Cooler Buncher

A new method of optical pumping in an ion beam cooler buncher has been developed to selectively enhance ionic metastable state populations. The technique permits the study of elements previously inaccessible to laser spectroscopy and has been applied here to the study of Nb. Model independent mean-square charge radii and nuclear moments have been studied for {sup 90,90m,91,91m,92,93,99,101,103}Nb to cover the region of the N=50 shell closure and N{approx_equal}60 sudden onset of deformation. The increase in mean-square charge radius is observed to be less than that for Y, with a substantial degree of {beta} softness observed before and after N=60.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of pressure-broadening and lineshift coefficients at 77 and 296 K of methane lines in the 727 nm band using intracavity laser spectroscopy

Pressure-broadening coefficients and pressure-induced lineshifts of several rotational-vibrational lines have been measured in the 727 nm absorption band of methane at temperatures of 77 and 296 K, using nitrogen, hydrogen, and helium as the foreign-gas collision partners. A technique involving intracavity laser spectroscopy is used to record the methane spectra. Average values of the broadening coefficients (/cm/atm) at 77 K are: 0.199, 0.139, 0.055, and 0.29 for collision partners N2, H2, He, and CH4, respectively. Typical average values of the pressure-induced lineshifts (/cm/atm) at 77 K and for the range of foreign gas pressures between 10 and 200 torr are -0.052 for N2, -0.063 for H2, and +0.031 for He. All the values obtained at 296 K are considerably different from the corresponding values at 77 K. This represents the first report of pressure-broadening and shifting coefficients for the methane transitions in a region where the delta nu(sub C-H) = 5 band occurs.

Singh, Kuldip↗

High-Resolution Laser Spectroscopy on the Negative Osmium Ion

We have applied a combination of laser excitation and electric-field detachment to negative atomic ions for the first time, resulting in an enhancement of the excited-state detection efficiency for spectroscopy by at least 2 orders of magnitude. Applying the new method, a measurement of the bound-bound electric-dipole transition frequency in {sup 192}Os{sup -} was performed using collinear spectroscopy with a narrow-bandwidth cw laser. The transition frequency was found to be 257.831 190(35) THz [wavelength 1162.747 06(16) nm, wave number 8600.3227(12) cm{sup -1}], in agreement with the only prior measurement, but with more than 100-fold higher precision.

74 ATOMIC AND MOLECULAR PHYSICS↗

Four-photon microwave laser spectroscopy of aqueous solutions of biopolymers

The four-photon laser radiation scattering spectra are obtained in the submillimetre range (75-95 cm{sup -1}) for deionised water, aqueous solutions of DNA and {alpha}-chymotrypsin protein. Narrow resonances are recorded whose frequencies coincide (within the resolution power of a spectrometer) with rotational frequencies in the ground electronic state and vibrational state of ortho and para isomers of H{sub 2}O molecule in a gas phase and with the frequencies of the lines of H{sub 2}O{sub 2} and OH{sup -} molecules. It is shown that the resonance contribution of the rotational lines of ortho isomers of H{sub 2}O to the signal of four-photon scattering of native solutions of biopolymers increases by a factor of at least 8 compared to their contribution to the scattering signal in water, and becomes considerably larger than the contribution from the paraisomer lines. Denaturation of DNA after heating and cooling of the solution leads to the disappearance of such selectivity. (special issue devoted to the 25th anniversary of the a.m. prokhorov general physics institute)

74 ATOMIC AND MOLECULAR PHYSICS↗

Structural trends in atomic nuclei from laser spectroscopy of tin

Tin is the chemical element with the largest number of stable isotopes. Its complete proton shell, comparable with the closed electron shells in the chemically inert noble gases, is not a mere precursor to extended stability; since the protons carry the nuclear charge, their spatial arrangement also drives the nuclear electromagnetism. We report high-precision measurements of the electromagnetic moments and isomeric differences in charge radii between the lowest 1/2 + , 3/2 + , and 11/2 - states in 117–131 Sn, obtained by collinear laser spectroscopy. Supported by state-of-the-art atomic-structure calculations, the data accurately show a considerable attenuation of the quadrupole moments in the closed-shell tin isotopes relative to those of cadmium, with two protons less. Linear and quadratic mass-dependent trends are observed. While microscopic density functional theory explains the global behaviour of the measured quantities, interpretation of the local patterns demands higher-fidelity modelling.

74 ATOMIC AND MOLECULAR PHYSICS↗

Methane overtone absorption by intracavity laser spectroscopy

Interpretation of planetary methane (CH4) visible-near IR spectra, used to develop models of planetary atmospheres, has been hampered by a lack of suitable laboratory spectroscopic data. The particular CH4 spectral bands are due to intrinsically weak, high overtone-combination transitions too complex for classical spectroscopic analysis. The traditional multipass cell approach to measuring spectra of weakly absorbing species is insufficiently sensitive to yield reliable results for some of the weakest CH4 absorption features and is difficult to apply at the temperatures of the planetary environments. A time modulated form of intracavity laser spectroscopy (ILS), has been shown to provide effective absorption pathlengths of 100 to 200 km with sample cells less than 1 m long. The optical physics governing this technique and the experimental parameters important for obtaining reliable, quantitative results are now well understood. Quantitative data for CH4 absorption obtained by ILS have been reported recently. Illustrative ILS data for CH4 absorption in the 619.7 nm and 681.9 nm bands are presented. New ILS facilities at UM-St. Louis will be used to measure CH4 absorption in the 700 to 1000 nm region under conditions appropriate to the planetary atmospheres.

Obrien, James J.↗

Ultraviolet laser spectroscopy of neutral mercury in a one-dimensional optical lattice

We present details on the ultraviolet lattice spectroscopy of the (6s{sup 2}) {sup 1}S{sub 0}{r_reversible} (6s6p) {sup 3}P{sub 0} transition in neutral mercury, specifically {sup 199}Hg. Mercury atoms are loaded into a one-dimensional vertically aligned optical lattice from a magneto-optical trap with an rms temperature of {approx}60 {mu}K. We describe aspects of the magneto-optical trapping, the lattice cavity design, and the techniques employed to trap and detect mercury in an optical lattice. The clock-line frequency dependence on lattice depth is measured at a range of lattice wavelengths. We confirm the magic wavelength to be 362.51(0.16) nm. Further observations to those reported by Yi et al.[Phys. Rev. Lett. 106, 073005 (2011)] are presented regarding the laser excitation of a Wannier-Stark ladder of states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of gas parameters in plasma-assisted supersonic combustion processes using diode laser spectroscopy

We report a procedure for temperature and water vapour concentration measurements in an unsteady-state combustion zone using diode laser absorption spectroscopy. The procedure involves measurements of the absorption spectrum of water molecules around 1.39 {mu}m. It has been used to determine hydrogen combustion parameters in M = 2 gas flows in the test section of a supersonic wind tunnel. The relatively high intensities of the absorption lines used have enabled direct absorption measurements. We describe a differential technique for measurements of transient absorption spectra, the procedure we used for primary data processing and approaches for determining the gas temperature and H{sub 2}O concentration in the probed zone. The measured absorption spectra are fitted with spectra simulated using parameters from spectroscopic databases. The combustion-time-averaged ({approx}50 ms) gas temperature and water vapour partial pressure in the hot wake region are determined to be 1050 K and 21 Torr, respectively. The large signal-to-noise ratio in our measurements allowed us to assess the temporal behaviour of these parameters. The accuracy in our temperature measurements in the probed zone is {approx}40 K. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Four-photon microwave laser spectroscopy of molecules in the hydration layers of biopolymers and nanoparticles

Four-photon laser scattering spectra of bidistilled water and aqueous solutions of biopolymers (proteins and DNA), carbon nanotubes and hydrogen peroxide have been measured in the range {+-}10 cm{sup -1}. The spectra show rotational resonances of H{sub 2}O{sub 2}, ortho-H{sub 2}O and para-H{sub 2}O molecules. The resonance contribution of the H{sub 2}O rotational spectrum to the four-photon scattering signal in the solutions of the biopolymers and hydrophobic nanoparticles is an order of magnitude larger in comparison with water, which points to free rotation of the water molecules near the surface of such particles. This effect is due to the formation of water depletion layers near hydrophobic nanoparticles, as predicted in earlier theoretical studies. (special issue devoted to the 80th birthday of S.A. Akhmanov)

74 ATOMIC AND MOLECULAR PHYSICS↗

Laser-spectroscopy testbed for impurity monitoring in liquid metal-cooled fast reactors

A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.

47 OTHER INSTRUMENTATION↗

Monitoring The Atmosphere By Diode-Laser Spectroscopy

Report describes state of art of tunable-diode-laser second-harmonic spectroscopy applied to measurements of concentrations of trace constituents of atmosphere. Combination of temperature, composition, and drive-current tuning, wavelengths of tunable diode lasers varied over infrared range of 3 to 30 micrometer, containing spectral lines of many molecules of interest in atmospheric research.

Loewenstein, Max↗