Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LABORATORY ANIMALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

X-Rays Compton Detectors For Biomedical Application

Collimators are usually needed to image sources emitting X-rays that cannot be focused. Alternately, one may employ a Compton Camera (CC) and measure the direction of the incident X-ray by letting it interact with a thin solid, liquid or gaseous material (Tracker) and determine the scattering angle. With respect to collimated cameras, CCs allow higher gamma-ray efficiency in spite of lighter geometry, and may feature comparable spatial resolution. CCs are better when the X-ray energy is high and small setups are required. We review current applications of CCs to Gamma Ray Astronomy and Biomedical systems stressing advantages and drawbacks. As an example, we focus on a particular CC we are developing, which is designed to image small animals administered with marked pharmaceuticals, and assess the bio-distribution and targeting capability of these latter. This camera has to address some requirements: relatively high activity of the imaged objects; detection of gamma-rays of different energies that may range from 140 keV (Tc99m) to 511 keV; presence of gamma and beta radiation with energies up to 2 MeV in case of 188Re. The camera consists of a thin position-sensitive Silicon Drift Detector as Tracker, and a further downstream position-sensitive system employing scintillating crystals and a multi-anode photo-multiplier (Calorimeter). The choice of crystal, pixel size, and detector geometry has been driven by measurements and simulations with the tracking code GEANT4. Spatial resolution, efficiency and scope are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thiazolidinediones abrogate cervical cancer growth

Peroxisome proliferator-activated receptor gamma (PPAR γ) is activated by thiazolidinedione drugs (TZDs) and can promote anti-cancer properties. We used three TZDs (pioglitazone, rosiglitazone, and ciglitazone) to target cervical cancer cell lines and a nude mouse animal model. Each agent increased activation of PPAR γ, as judged by a luciferase reporter gene assay in three HPV-associated cell lines (CaSki, SiHa, and HeLa cells) while decreasing cellular proliferation in a dose-dependent manner. They also promoted Oil Red O accumulation in treated cell lines and upregulated the lipid differentiation marker adipsin. Interestingly, xenograft HeLa tumors in nude mice treated with 100 mg/kg/day pioglitazone exhibited decreased growth compared to control mice or mice treated with standard cervical chemotherapy. In conclusion, TZDs slow tumor cell growth in vitro and in vivo with decreases in cell proliferation and increases in PPAR γ and adipsin. These agents may be interesting treatments or treatment adjuncts for HPV-associated cancers or perhaps even precancerous conditions. - Highlights: • Thiazolidinediones decreases cervical cancer proliferation. • Pioglitazone increases cervical cancer differentiation. • Pioglitazone decreases tumor growth in mice. • Pioglitazone may be a useful treatment adjunct.

60 APPLIED LIFE SCIENCES↗

Lymphangiography and Post-lymphangiographic Multidetector CT for Preclinical Lymphatic Interventions in a Rabbit Model

Purpose: To describe the feasibility of lymphangiography and the visibility of the lymphatic system using post-lymphangiographic multidetector CT (MDCT) for preclinical lymphatic interventions in a rabbit model. Materials and Methods: Lymphangiography via the popliteal lymph node or vessel after surgical exposure was performed, using six healthy female Japanese White rabbits. Lipiodol was manually injected for lymphangiography. Post-lymphangiographic MDCT examinations were performed in all rabbits. The dataset images were subjected to image processing analysis utilizing the three-dimensional maximum intensity projection technique. Three reviewers evaluated the degree of depiction of the lymphatic system using a four-point visual score (1, poor; 2, fair; 3, good; 4, excellent). The distance between the body surface and cisterna chyli was measured on post-lymphangiographic MDCT axial image. Results: Lymphangiography was successfully performed in all rabbits. The popliteal lymph node was detectable in 90%. The visualization of lymphatic system via the popliteal node was achieved in 89%. Mean visual scores of > 3.0 were realized by the right femoral lymphatic vessel, left femoral lymphatic vessel, left iliac lymphatic vessel, left lumbar lymphatic trunks and cisterna chyli, whereas mean visual scores of < 3.0 were yielded by the right iliac lymphatic vessel, right lumbar lymphatic trunks and thoracic duct. The distance between the body surface and cisterna chyli on post-lymphangiographic MDCT axial images was 4.33 ± 0.14 cm. Conclusion: Lymphangiography is feasible, and the visibility of the lymphatic system on post-lymphangiographic MDCT in a rabbit model provides enough information for interventional radiologists to perform preclinical lymphatic interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of photon irradiation treatment upon calcium content of ribs of Wistar rats using micro-XRF

Therapeutic doses of radiation have been shown to have deleterious consequences on bone health. Among the treatment strategies used for breast cancer treatment, the most used are radiotherapy and chemotherapy. Radiotherapy may be given to destroy the cancer cells using high-dose x-rays. Protocols vary considerably, but generally whole body irradiation totals from 10 to 15 Gy, whereas local therapy totals from 40 to 70 Gy. In clinical practice, the quantitative evaluation of bone tissue relies on measurements of bone mineral density values, which are closely associated with the risk of osteoporotic fracture. Improved survivorship rates of cancer patients receiving radiotherapy increase the importance of understanding the mechanisms and long-term effects of radiation-induced bone loss. In this work, we investigated the variation on calcium distribution in ribs of female Wistar rats (Rattus norvegicus) submitted to photon irradiation with a single dose of 20 Gy. The determination of the calcium distribution was performed using synchrotron radiation microfluorescence (SR-{mu}XRF) at the X-ray Fluorescence beamline at Brazilian Synchrotron Light Laboratory (LNLS). Animals were irradiated using the linear accelerator Varian registered (CLINAC 2100) at the University Centre for Cancer Control of the State University of Rio de Janeiro (CUCC/UERJ). The total dose delivered was 20 Gy. The animals were about three months old and weighting about 200g. They were distributed into two groups (seven per group): control (did not receive any treatment) and irradiated (submitted to irradiation procedure) groups. Results showed that calcium content decreased within the dorsal ribs of rats submitted to radiotherapy in comparison to the control group.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Behavior of Americium in Simulated Wounds in Nonhuman Primates

An americium solution injected intramuscularly into several nonhuman primates (NHPs) was found to behave differently than predicted by the wound models described in the NCRP Report 156. This was because the injection was made along with a citrate solution, which is known to be more soluble than chlorides, oxides, or nitrates on which the NCRP Report was based. We developed a multi-exponential wound model specific to the injected americium solution based on the retention in the intramuscular sites. The model was coupled with the americium systemic model to interpret the urinary excretion data and assess the intake, and it was determined that the models were adequate to predict early urinary excretion in most cases but unable to predict late urinary excretion. This was attributed to the differences in the systemic handling of americium between humans and nonhuman primates. Furthermore, information on the type of wounds, solubility, particle size, mass, chemical form, etc., should always be considered when performing wound dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiobiology, Omics and Microdosimetry of Systemic and Targeted Radiotherapeutics Workshop

The Radiobiology, Omics and Microdosimetry of Systemic and Targeted Radiotherapeutics Workshop fostered engagement across disciplines on critical topics that impact the development of targeted radionuclide therapies, bringing together scientific and medical professionals actively involved in radiotherapeutic design, optimization testing, patient treatment, and clinical trials along with basic science researchers, whose novel techniques have the potential to further our understanding of targeted radionuclide therapy. Discussion of the applications of radiotherapeutics to pediatric and adult, brain, prostate and blood cancers, and metastatic disease allowed scientific research to be presented in the context of real-world medical applications and provided an important backdrop to the basic research performed in computers, laboratories, and animal facilities. The workshop format, presentations, and panel discussions were designed to consider a holistic approach to the development of systemic and targeted radiotherapies, integrating radiobiology and microdosimetry, biological assessments on the microscale, and physiologically relevant models of tumor and tissue microenvironments. Important needs highlighted in the workshop include better models to assess the biological effects of radionuclide therapy, novel strategies to target radiotherapeutics to disease sites with high specificity, and new dosimetry techniques that address the importance of tumor microenvironments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

classLog: Logistic regression for the classification of genetic sequences

Introduction Sequencing and phylogenetic classification have become a common task in human and animal diagnostic laboratories. It is routine to sequence pathogens to identify genetic variations of diagnostic significance and to use these data in realtime genomic contact tracing and surveillance. Under this paradigm, unprecedented volumes of data are generated that require rapid analysis to provide meaningful inference. Methods We present a machine learning logistic regression pipeline that can assign classifications to genetic sequence data. The pipeline implements an intuitive and customizable approach to developing a trained prediction model that runs in linear time complexity, generating accurate output rapidly, even with incomplete data. Our approach was benchmarked against porcine respiratory and reproductive syndrome virus (PRRSv) and swine H1 influenza A virus (IAV) datasets. Trained classifiers were tested against sequences and simulated datasets that artificially degraded sequence quality at 0, 10, 20, 30, and 40%. Results When applied to a poor-quality sequence data, the classifier achieved between >85% to 95% accuracy for the PRRSv and the swine H1 IAV HA dataset and this increased to near perfect accuracy when using the full dataset. The model also identifies amino acid positions used to determine genetic clade identity through a feature selection ranking within the model. These positions can be mapped onto a maximum-likelihood phylogenetic tree, allowing for the inference of clade defining mutations. Discussion Our approach is implemented as a python package with code available at https://github.com/flu-crew/classLog .

Zeller, Michael A.↗

Operation and Maintenance of the National Radiobiology Archives

The National Radiobiology Archives (NRA) are an archival program, started in 1989, to collect, organize and maintain data, laboratory notebooks, and animal tissue specimens from government (Department of Energy and its predecessor agencies) sponsored radiobiology life-span animal studies. These unique records, histopathology slides and paraffin embedded tissue blocks are maintained in a central facility and are available for further research study. The materials include electronic and paper records for each of more than 6,000 life-span-observations on dogs as well as details of major studies involving nearly 30,000 mice. Although these studies were performed over many years and at different laboratories with differing data management systems, the NRA has translated them into a standardized set of relational database tables. These can be distributed to interested individuals on written request. Specific Aims are: (1) To Maintain the Archive of Written Records from the Animal Experiments - The USTUR continued to maintain the NRA archives which consist of approximately 175 storage boxes containing laboratory notebooks, animal exposure records, animal pathologic records, and radiographs. These were stored in a 6,000 square foot leased facility in Richland, WA. Additionally, through a collaboration with Pacific Northwest National Laboratory's (PNNL) Low Dose Program, many of these records were scanned into digital files. These totaled 34 GB of data, which are saved in 2,407 separate PDF files that are organized by box number and animal identification number. (2) To Maintain the Archive of Animal Tissues at Washington State University - The USTUR continued to house the NRA dog tissue collection in the leased facility. The NRA tissue collection consisted of pathology slides and tissue blocks. Approximately 25% of the laboratory facility was dedicated to the storage of the NRA materials. (3) To Organize the Datasets of These Animals in the Context of Other Datasets so That They Can be Used by the Scientific Community at Large - As was reported in the FY2009 NRA progress report, Dr. Chuck Watson (NRA Database Consultant) completed his service as the US representative on the European Radiobiological Archives (ERA) Advisory Board during FY2009. Unfortunately, due to the lack of financial support during FY2010, the NRA was not able to make further contributions to the ERA's efforts.

59 BASIC BIOLOGICAL SCIENCES↗

Imminent Cardiac Risk Assessment via Optical Intravascular Biochemical Analysis

Heart disease is by far the biggest killer in the United States, and type II diabetes, which affects 8% of the U.S. population, is on the rise. In many cases, the acute coronary syndrome and/or sudden cardiac death occurs without warning. Atherosclerosis has known behavioral, genetic and dietary risk factors. However, our laboratory studies with animal models and human post-mortem tissue using FT-IR microspectroscopy reveal the chemical microstructure within arteries and in the arterial walls themselves. These include spectra obtained from the aortas of ApoE-/- knockout mice on sucrose and normal diets showing lipid deposition in the former case. Also pre-aneurysm chemical images of knockout mouse aorta walls, and spectra of plaque excised from a living human patient are shown for comparison. In keeping with the theme of the SPEC 2008 conference Spectroscopic Diagnosis of Disease this paper describes the background and potential value of a new catheter-based system to provide in vivo biochemical analysis of plaque in human coronary arteries. We report the following: (1) results of FT-IR microspectroscopy on animal models of vascular disease to illustrate the localized chemical distinctions between pathological and normal tissue, (2) current diagnostic techniques used for risk assessment of patients with potential unstable coronary syndromes, and (3) the advantages and limitations of each of these techniques illustrated with patent care histories, related in the first person, by the physician coauthors. Note that the physician comments clarify the contribution of each diagnostic technique to imminent cardiac risk assessment in a clinical setting, leading to the appreciation of what localized intravascular chemical analysis can contribute as an add-on diagnostic tool. The quality of medical imaging has improved dramatically since the turn of the century. Among clinical non-invasive diagnostic tools, laboratory tests of body fluids, EKG, and physical examination are still the first line of defense. However, with the fidelity of 64-slice CT imaging, this technique has recently become an option when the patient presents with symptoms of reduced arterial flow. Single photon emission computerized tomography (SPECT) treadmill exercise testing is a standard non-invasive test for decreased perfusion of heart muscle, but is time consuming and not suited for emergent evaluation. Once the invasive clinical option of catherization is chosen, this provides the opportunity for intravascular ultrasound (IVUS) imaging. As the probe is pulled through the artery, the diameter at different parts is measurable, and monochrome contrast in the constricted area reveals the presence of tissue with a different ultrasonic response. Also, via an optical catheter with a fiber-optic conductor, the possibly of spectroscopic analysis of arterial walls is now a reality. In this case, the optical transducer is coupled to a near-infrared spectrometer. Revealing the arterial chemical health means that plaque vulnerability and imminent risk could be assessed by the physician. The classical emergency use of catherization involves a contrast agent and dynamic X-ray imaging to locate the constriction, determine its severity, and possibly perform angioplasty, and stent placement.

60 APPLIED LIFE SCIENCES↗

Knockout of exogenous EGFP gene in porcine somatic cells using zinc-finger nucleases

Research highlights: {yields} EGFP gene integrated in porcine somatic cells could be knocked out using the ZFN-KO system. {yields} ZFNs induced targeted mutations in porcine primary cultured cells. {yields} Complete absence of EGFP fluorescence was confirmed in ZFN-treated cells. -- Abstract: Zinc-finger nucleases (ZFNs) are expected as a powerful tool for generating gene knockouts in laboratory and domestic animals. Currently, it is unclear whether this technology can be utilized for knocking-out genes in pigs. Here, we investigated whether knockout (KO) events in which ZFNs recognize and cleave a target sequence occur in porcine primary cultured somatic cells that harbor the exogenous enhanced green fluorescent protein (EGFP) gene. ZFN-encoding mRNA designed to target the EGFP gene was introduced by electroporation into the cell. Using the Surveyor nuclease assay and flow cytometric analysis, we confirmed ZFN-induced cleavage of the target sequence and the disappearance of EGFP fluorescence expression in ZFN-treated cells. In addition, sequence analysis revealed that ZFN-induced mutations such as base substitution, deletion, or insertion were generated in the ZFN cleavage site of EGFP-expression negative cells that were cloned from ZFN-treated cells, thereby showing it was possible to disrupt (i.e., knock out) the function of the EGFP gene in porcine somatic cells. To our knowledge, this study provides the first evidence that the ZFN-KO system can be applied to pigs. These findings may open a new avenue to the creation of gene KO pigs using ZFN-treated cells and somatic cell nuclear transfer.

60 APPLIED LIFE SCIENCES↗

No-touch measurements of vital signs in small conscious animals

Measuring the heartbeat and respiration of small conscious animals is important for assessing their health and behavior, but present techniques such as electrocardiogram (ECG), ultrasound, and auscultation rely on close skin contact with the animal. These methods can also require surface preparation, cause discomfort or stress to animals, and even require anesthetic administration, especially for birds, reptiles, and fish. Here, we show that radio frequency near-field coherent sensing (NCS) can provide a new solution to animal vital sign monitoring while ensuring minimal pain and distress. We first benchmarked NCS with synchronous ECG on an anesthetized rat. NCS was then applied to monitor a conscious hamster from outside its cage, and was further extended to a parakeet, Russian tortoise, and betta fish in a noninvasive manner. Our system can revolutionize vital sign monitoring of small conscious animals in their laboratory living quarters or natural habitats.

47 OTHER INSTRUMENTATION↗

Biosafety and biosecurity in veterinary laboratories

Here, with recent outbreaks of MERS-Cov, Anthrax, Nipah, and Highly Pathogenic Avian Influenza, much emphasis has been placed on rapid identification of infectious agents globally. As a result, laboratories are building capacity, conducting more advanced and sophisticated research, increasing laboratory staff, and establishing collections of dangerous pathogens in an attempt to reduce the impact of infectious disease outbreaks and characterize disease causing agents. With this expansion, the global laboratory community has started to focus on laboratory biosafety and biosecurity to prevent the accidental and/or intent ional release o f these agents. Laboratory biosafety and biosecurity systems are used around the world to help mit igate the risks posed by dangerous pathogens in the laboratory. Veterinary laboratories carry unique responsibilities to workers and communities to safely and securely handle disease causing microorganisms. Many microorganisms studied in veterinary laboratories not only infect animals, but also have the potential to infect humans. This paper will discuss the fundamentals of laboratory biosafety and biosecurity.

59 BASIC BIOLOGICAL SCIENCES↗

Past and Future Work on Radiobiology Mega-Studies: A Case Study At Argonne National Laboratory

Between 1952 and 1992, more than 200 large radiobiology studies were conducted in research institutes throughout Europe, North America, and Japan to determine the effects of external irradiation and internal emitters on the lifespan and tissue toxicity development in animals. At Argonne National Laboratory, 22 external beam studies were conducted on nearly 700 beagle dogs and 50,000 mice between 1969 and 1992. These studies helped to characterize the effects of neutron and gamma irradiation on lifespan, tumorigenesis, and mutagenesis across a range of doses and dosing patterns. The records and tissues collected at Argonne during that time period have been carefully preserved and redisseminated. Using these archived data, ongoing statistical work has been done and continues to characterize quality of radiation, dose, dose rate, tissue, and gender-specific differences in the radiation responses of exposed animals. The ongoing application of newly-developed molecular biology techniques to the archived tissues has revealed gene-specific mutation rates following exposure to ionizing irradiation. The original and ongoing work with this tissue archive is presented here as a case study of a more general trend in the radiobiology megastudies. These experiments helped form the modern understanding of radiation responses in animals and continue to inform development of new radiation models. Recent archival efforts have facilitated open access to the data and materials produced by these studies, and so a unique opportunity exists to expand this continued research.

59 BASIC BIOLOGICAL SCIENCES↗

Large Game Distribution Camera Study at Los Alamos National Laboratory

The unique habitats at the Laboratory support a diverse community of wildlife. The habitat types that include Pinon Juniper, Ponderosa Pine, and Mixed-conifer forests each provide different resources important for a variety of species. Wildlife monitoring for large game animals can be challenging because they avoid interactions with humans, and prefer undeveloped areas. This study was conducted to analyze the distribution of predators and other game animals seasonally across the Laboratory. This research informs decisions regarding wildlife management recommendations for conservation and protection. This study utilized game cameras to remotely monitor wildlife. As camera technology has advanced, game cameras have become adequate for documenting individuals, and are commonly used in wildlife studies on predation, abundance, occupancy, diversity, and endangered species detection. Twenty cameras were placed across the LANL landscape using a modified systematic sampling design. They were deployed in February 2018 and retrieved in January 2019, thus each camera sampled for one full year. All images were reviewed and the species, number, age, and sex of all animals in the photo were recorded. Here we present data for the most abundant species encountered: deer, elk, coyote, bear, bobcat, mountain lion, and fox respectively. The data were summarized by species and season. Future work will include occupancy modelling for each species. This will allow the development of heat maps showing species distributions across the Laboratory.

59 BASIC BIOLOGICAL SCIENCES↗

Large Game Distribution Camera Study at Los Alamos National Laboratory [Poster]

The unique habitats at the Laboratory support a diverse community of wildlife. The habitat types that include Pinon Juniper, Ponderosa Pine, and Mixed-conifer forests each provide different resources important for a variety of species. Wildlife monitoring for large game animals can be challenging because they avoid interactions with humans, and prefer undeveloped areas. This study was conducted to analyze the distribution of predators and other game animals seasonally across the Laboratory. The data gathered will be used to make recommendations regarding wildlife management for conservation and protection. Utilizing game cameras to remotely monitor wildlife was determined to be the most effective, noninvasive method to gather the necessary data. As camera technology has advanced, game cameras have become adequate for documenting individuals, and are commonly used in wildlife studies on predation, abundance, occupancy, diversity, and endangered species detection. Twenty cameras were placed across the LANL landscape using a modified systematic sampling design. They were deployed in February 2018 and retrieved in January 2019, thus each camera sampled for one full year. All images were reviewed and the species, number, age, and sex of all animals in the photo were recorded. Here we present data for the most abundant species encountered: deer, elk, coyote, bear, bobcat, mountain lion, and fox respectively. The data were summarized by species and season. Future work will include occupancy modelling for each species. This will allow the development of heat maps showing species distributions across the Laboratory.

54 ENVIRONMENTAL SCIENCES↗

Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the use of resolution recovery techniques (i.e. modeling the finite collimator spatial resolution in iterative reconstruction algorithms) can significantly reduce the partial volume errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-U-02: The Development of a Practical Ultrasonic System for Cross-Sectional Imaging of Small Animals

Purpose: To test the feasibility of developing a practical medium frequency ultrasound tomography method for small animal imaging. The ability to produce cross-sectional or full body images of a live small animal using a low-cost tabletop ultrasound scanner without any special license would be very beneficial to long term biological studies, where repeated scanning is often required over an extended period of time. Methods: The cross sectional images were produced by compounding multiple B-scans of a laboratory phantom or an animal acquired at different projection angles. Two imaging systems were used to test the concept. The first system included a programmable 64-channel phased array controller driving a 128-channel, 5–10 MHz linear probe to produce 143 B-Mode projections of the spinning object. The second system designed and manufactured in house, produced 64 or 128 B-Mode projections with a single unfocused 8 MHz transducer scanning with a 0.116 mm step size. Results: The phased array system provided good penetration through the phantoms/mice (with the exception of the lungs) and allowed to acquire data in a very short time. The cross-sectional images have enough resolution and dynamic range to detect both high- and low-contrast organs. The single transducer system takes longer to scan, and the data require more sophisticated processing. To date, our images allow seeing details as small as 1–2 mm in the phantoms and in small animals, with the contrast mostly due to highly reflecting bones and air inclusions. Conclusion: The work indicates that very detailed and anatomically correct images can be created by relatively simple and inexpensive means. With more advanced algorithms and improved system design, scan time can be reduced considerably, enabling high-resolution full 3D imaging. This will allow for quick and easy scans that can help monitor tumor growth and/or regression without contributing any dose to the animal. The authors would like to acknowledge the financial and engineering support from Tessonics.

60 APPLIED LIFE SCIENCES↗