Ions with low charges in the solar wind as measured by SWICS on board Ulysses

We present new data on rare ions in the solar wind. Using the Ulysses-SWICS instrument with its very low background we have searched for low-charge ions during a 6-d period of low-speed solar wind and established sensitive upper limits for many species. In the solar wind, we found He(1+)/He(2+) of less than 5 x 10 exp -4. This result and the charge state distributions of heavier elements indicate that all components of the investigated ion population went through a regular coronal expansion and experienced the typical electron temperatures of 1 to 2 million Kelvin. We argue that the virtual absence of low-charge ions demonstrates a very low level of nonsolar contamination in the source region of the solar wind sample we studied. Since this sample showed the FlP effect typical for low-speed solar wind, i.e., an enhancement in the abundances of elements with low first ionization potential, we conclude that this enhancement was caused by an ion-atom separation mechanism operating near the solar surface and not by foreign material in the corona.

Geiss, J.↗

Miniature quadrupole mass spectrometer array

The present invention provides a minature quadrupole mass spectrometer array for the separation of ions, comprising a first pair of parallel, planar, nonmagnetic conducting rods each having an axis of symmetry, a second pair of planar, nonmagnetic conducting rods each having an axis of symmetry parallel to said first pair of rods and disposed such that a line perpendicular to each of said first axes of symmetry and a line perpendicular to each of said second axes of symmetry bisect each other and form a generally 90 degree angle. A nonconductive top positioning plate is positioned generally perpendicular to the first and second pairs of rods and has an aperture for ion entrance along an axis equidistant from each axis of symmetry of each of the parallel rods, a nonconductive bottom positioning plate is generally parallel to the top positioning plate and has an aperture for ion exit centered on an axis equidistant from each axis of symmetry of each of the parallel rods, means for maintaining a direct current voltage between the first and second pairs of rods, and means for applying a radio frequency voltage to the first and second pairs of rods.

Chutjian, Ara↗

Miniature quadrupole mass spectrometer array

The present invention provides a minature quadrupole mass spectrometer array for the separation of ions, comprising a first pair of parallel, planar, nonmagnetic conducting rods each having an axis of symmetry, a second pair of planar, nonmagnetic conducting rods each having an axis of symmetry parallel to said first pair of rods and disposed such that a line perpendicular to each of said first axes of symmetry and a line perpendicular to each of said second axes of symmetry bisect each other and form a generally 90 degree angle. A nonconductive top positioning plate is positioned generally perpendicular to the first and second pairs of rods and has an aperture for ion entrance along an axis equidistant from each axis of symmetry of each of the parallel rods, a nonconductive bottom positioning plate is generally parallel to the top positioning plate and has an aperture for ion exit centered on an axis equidistant from each axis of symmetry of each of the parallel rods, means for maintaining a direct current voltage between the first and second pairs of rods, and means for applying a radio frequency voltage to the first and second pairs of rods.

Chutjian, Ara↗

Ion optics system incorporating radio frequency mass separation

Results of an experimental study are presented. They show that an RF mass discriminator, based on a Bennett mass spectrometer concept, can be used to discriminate between two species of ions with about a 2-to-1 charge-to-mass ratio. Such a device would be useful for separating monatomic and diatomic oxygen ions in a system designed to simulate the environment that spacecraft encounter in low earth orbit. The influence of changing mass discriminator parameters - such as the spacing of its grids, the amplitude and frequency of RF voltage signals applied to it and the current density of ions incident upon it - on its species discrimination capabilities is discussed. Experimental results are also compared to the results of a simple theoretical model to gain insight into the processes occurring in the discriminator. These results are shown to be in good agreement.

Anderson, John R.↗

Termolecular ionic recombination at high ambient gas density

It is shown that the importance of diffusion relative to drift in ion-ion recombination is a decreasing function of the separation between the ions (contrary to a common supposition). Langevin's formula for the recombination coefficient is obtained very simply using a physical model which allows for both diffusion and drift.

Bates, D. R.↗

Alkaline battery, separator therefore

An improved battery separator for alkaline battery cells has low resistance to electrolyte ion transfer and high resistance to electrode ion transfer. The separator is formed by applying an improved coating to an electrolyte absorber. The absorber, preferably, is a flexible, fibrous, and porous substrate that is resistant to strong alkali and oxidation. The coating composition includes an admixture of a polymeric binder, a hydrolyzable polymeric ester and inert fillers. The coating composition is substantially free of reactive fillers and plasticizers commonly employed as porosity promoting agents in separator coatings. When the separator is immersed in electrolyte, the polymeric ester of the film coating reacts with the electrolyte forming a salt and an alcohol. The alcohol goes into solution with the electrolyte while the salt imbibes electrolyte into the coating composition. When the salt is formed, it expands the polymeric chains of the binder to provide a film coating substantially permeable to electrolyte ion transfer but relatively impermeable to electrode ion transfer during use.

Schmidt, George F.↗

Separation of isobaric Amino Acids and Small Molecule Metabolites Using Multipass Ion Mobility Analysis

Amino acids along with small molecule metabolites are important biomarkers for the study and detection of diseases that are initially analyzed in untargeted omics fashion. Amino acids and many metabolites are isomeric, and their specific form can have a significant impact on biological function. Chromatographic separation of isomers is challenging, and they cannot be resolved by mass spectrometry alone. Ion mobility is a technique that allows the separation of ions based on their size, shape, and charge. Here we present the results of the separation of isobaric amino acids and small molecule metabolites using a system that allows for multi-pass ion mobility separation which, in turn, enhances the ion mobility resolution of the separation. Amino acid standards and small molecule metabolites commercially available were infused directly into a SELECT SERIES™ Cyclic™ IMS system. Solutions of individual and mixture of the isobaric species were used and the mobility conditions were optimized for multiple passes for each corresponding set of isobaric species. Both ionization polarities and various solvent adducts were tested to provide the best signal intensity and separation. Amino acids such as leucine and isoleucine have previously been separated with ion mobility in a system with lower ion mobility resolution (SYNAPT™ G2 mass spectrometer) rendering about 90% of valley and mobility resolution of around 40 Ω/ΔΩ. With the enhanced ion mobility resolution using the cyclic IMS technique we have obtained almost complete separation of those amino acids rendering a valley of about 10% after 15 passes. For this case, the mobility resolution is around 250 Ω/ΔΩ. Another example is the separation of glucose-6-phosphate from glucose-1-phosphate, and fructose-6phosphate which were separated after 10 passes. For this case, the mobility resolution is around 205 Ω/ΔΩ.

Hernando J Olivos↗

Capillary electrophoresis: Biotechnology for separation of DNA and chromosomes

Electrophoresis has been used for the separation of particles, ions, and molecules for a number of years. The technology for separation and detection of the results has many applications in the life sciences. One of the major goals of the scientific community is to separate DNA molecules and intact chromosomes based upon their different lengths or number of base pairs. This may be achieved by using some of the commercially available and widely used methods, but these processes require a considerable amount of time. The challenge is to achieve separation of intact chromosomes in a short time, preferably in a matter of minutes.

Williams, George O., Jr.↗

The binding energies of one and two water molecules to the first transition-row metal positive ions

The bonding of water to the transition metal positive ions is electrostatic in origin. The electrostatic bonding is enhanced by a variety of mechanisms: mixing in 4p character, 4s-3d hybridization, and 4s promotion into the compact 3d orbital. The importance of these effects varies between the different metal ions due to changes in the separation of the metal ion atomic states. Furthermore, the change in the metal-water repulsion when a second water is added also changes the relative importance of the different metal asymptotes. The second water binding energy varies from being 11 kcal/mol smaller than the first for Mn(+) to 3 kcal/mol larger for V(+) and Fe(+).

Rosi, Marzio↗

Particle simulations of electrostatic emissions near the lower hybrid frequency

The linear instability and nonlinear saturation of electrostatic emission near the lower hybrid frequency is examined for model cold and warm ion ring distributions and auroral zone parameters. In the cold ring case, a single coherent mode near omega (LH) evolves, and saturates by ion trapping. In the warm ring case, a discrete spectrum of unstable modes separated by the ion gyrofrequency is generated near and above omega (LH). The latter instability saturates by quasilinear diffusion.

Roth, I.↗

The interaction between an impact-produced neutral gas cloud and the solar wind at the lunar surface

On Apr. 15, 1970, the Apollo 13 S-IVB stage impacted the nighttime lunar surface. Beginning 20 sec after impact, the Suprathermal Ion Detector Experiment and the Solar Wind Spectrometer observed a large flux of positive ions (maximum flux of about 3 x 10 to the 8th ions/sq cm/sec/ster) and electrons. Two separate streams of ions were observed: a horizontal flux that appeared to be deflected solar wind ions and a smaller vertical flux of predominantly heavy ions (greater than 10 amu), which probably were material vaporized from the S-IVB stage. An examination of the data shows that collisions between neutral molecules and hot electrons (50 eV) were probably an important ionization mechanism in the impact-produced neutral gas cloud. These electrons, which were detected by the Solar Wind Spectrometer, are thought to have been energized in a shock front or some form of intense interaction region between the cloud and the solar wind. Thus strong ionization and acceleration are seen under conditions approaching a collisionless state.

Lindeman, R. A.↗

Search for selective ion diffusion through membranes

The diffusion rates of several ions through some membranes developed as battery separators were measured. The ions investigated were Li(+), Rb(+), Cl(-), and So4. The members were crosslinked polyvinyl alcohol, crosslinked polyacrylic acid, a copolymer of the two, crosslinked calcium polyacrylate, cellulose, and several microporous polyphenylene oxide based films. No true specificity for diffusion of any of these ions was found for any of the membranes. But the calcium polyacrylate membrane was found to exhibit ion exchange with the diffusing ions giving rise to the leaching of the calcium ion and low reproducibility. These findings contrast earlier work where the calcium polyacrylate membrane did show specificity to the diffusion of the copper ion. In general, Fick's law appeared to be obeyed. Except for the microporous membranes, the coefficients for ion diffusion through the membranes were comparable with their values in water. For the microporous membranes, the values found for the coefficients were much less, due to the tortuosity of the micropores.

May, C. E.↗

Interaction of two collisionless shocks

Kinetic simulations of the interaction between two collisionless shocks are presented. During the collision of two perpendicular shocks, the shock electromagnetic field structures pass through each other, while the previously shocked ions are kept separate by the electric field arising in the collision. When two supercritical shocks collide, a fraction of ions are accelerated up to an order of magnitude in energy by first being reflected at one shock, then interacting with the electric fields of the other shock.

Cargill, P. J.↗

AUREOL-3 observations of new boundaries in the auroral ion precipitation

Interesting and well-separated structures in the 1-20 keV ion precipitation pattern have been revealed by an analysis of more than 50 crossings of the nightside (21-03 MLT) auroral zone by the AUREOL-3 satellite. First, velocity-dispersed ion structures (VDIS) are crossed near the poleward edge of the oval, and are the best ionospheric signature of ion beams flowing along the plasma sheet boundary layer. Proceeding equatorward, a large majority of VDIS events are bounded by a new and interesting narrow band of strongly reduced precipitation, or a gap, which delineates VDIS from the diffuse precipitation region connected to the CPS. A statistical analysis shows that the gap has an extent of about 1-2 deg, which is almost independent of magnetic activity; its location, about 70 deg ILAT, shifts significantly equatorward with higher magnetic activity levels. Intense electron arcs are observed near the equatorward edge of the gap. An important result is that the overall sequence of VDIS-gap-CPS can be explained in terms of orbital dynamics in the tail. The gap in precipitation appears as the counterpart of the 'wall' regime in the equatorial plane, in which a cross-tail current carried by energetic ions is strongly enhanced between 8 and 12 R(E). This region has important consequences for the development of substorms.

Bosqued, Jean M.↗

Electrostatic Kelvin-Helmholtz instability in a radially injected plasma cloud

An elecrostatic finite-sized particle simulation model is used to study the early time-scale phenomena asociated with an impulsively injected plasma, expanding radially, normal to a strong ambient magnetic field. Results of the simulation show the early formation of a radial polarization electric field due to ion-electron charge separation which causes electrons to drift in the azimuthal direction. Velocity shear within this motion gives rise to a Kelvin-Helmholtz (dioxotron) instability, creating a radial fluted pattern as the plasma expands. In the nonlinear stage of instability, azimuthal variations in the electric field are observed which cause electrons to drift across the magnetic field, thereby reducing the space charge created by energetic ion expansion. The results of a linear stability analysis reveal that for a decreasing amount of charge separation in the plasma, the number of unstable azimuthal modes at maximum growth rate increases. Also, as the thickness of the electron ring increases, a fewer number of unstable modes develops for a given amount of charge separation. It is concluded that electrons become unstable at the very early time scale, within an ion gyroperiod, and that unstable electrons lead to modification of the ion dynamics.

Sydora, R. D.↗

Transport of gyration-dominated space plasmas of thermal origin. I - Generalized transport equations

Grad's 20-moment set of transport equations has been examined in the limit of strong external magnetic fields. This simplified set of equations describes the transport of mass and parallel momentum as well as the transport of parallel and perpendicular energy and heat flow in the magnetic field direction. The effect of collisions was calculated assuming a modified relaxation model. Wave speeds and normal modes of the simplified set of equations were examined for an ion and electron gas. It was found that four of the ten normal modes are electron thermal-heat waves which approximately decouple from the six ion waves in the system. When low-frequency waves are considered (slow-wave approximation), this allows the electron energy and heat flow equations to be solved separately from the ion equations and in a time-independent fashion. When this was done, it was found that, under certain conditions, these equations predict an infinite electron perpendicular temperature, Te-perpendicular, in the collisionless regime. This occurs whenever Te-perpendicular is greater than the parallel temperature, at any point along collisionless and diverging magnetic field lines. When applied appropriately, the significantly simplified set of equations derived here are well suited for application to a large variety of problems in planetary ionospheres and magnetospheres.

Gombosi, Tamas I.↗

The Wind and Temperature Spectrometer (WTS) in the Atmospheric Neutral Density Experiment (ANDE) Satellite

Miniaturization efforts in new spectrometers for ionosphere/thermosphere investigations of the ion-drifts and neutral winds and corresponding temperatures make possible very light (about 250 g) packages consuming less than 0.4 W. Previously described, our approach measures the angular and energy distributions of neutral atoms and molecules (or ions) in two perpendicular planes; using those distributions to determine the full wind vector, the temperature and the relative densities of O and N2, as required for the ANDE mission. The measurements require two separate electron impact ion sources each with its own electron beam cathode. We have developed a low-temperature thermionic emission cathode that delivers 1 mA electron current at 80 mW power, making it possible to operate neutral wind-temperature experiments for the first time with powers less than 0.5 W. Advances in the ion optics of the energy-angle spectrometer enhance the energy resolution-aperture product more than a factor of 3 to enable energy resolutions of a few percent with large apertures. With these technology improvements it is now possible to obtain the full neutral wind vector, temperature and O/N2, density ratio once per second in a 250g/0.4W package with sensitivity up to about 500 km altitude in the thermosphere. We will describe the WTS as deployed in ANDE and show simulated data with the non-linear least squares analysis to illustrate expected performance of the WTS in the estimated errors in the three components of the wind, the temperature, and the relative densities.

Herrero, F. A.↗