Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Integration and Testing of DERs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Distributed Wind Considerations from the IEEE 1547-2018 Revision

The revision of the U.S. interconnection Standard IEEE 1547 in 2018 (IEEE 1547-2018) has added new interconnection and interoperability requirements for grid-connected distributed wind generators (DWG / wind turbines) and all other distributed energy resources (DERs). These new requirements will enable distributed wind generators to provide greater benefits to electric grid operators and DER operators, but also presents new challenges for the testing and certification of DWG systems. This report provides a summary of recent interconnection standard revisions from a DWG perspective, outlines the potential benefits to the power system from the revisions, evaluates the main concerns from a DWG manufacturer’s perspective, and provides general industry guidance related to IEEE 1547-2018 adoption.

17 WIND ENERGY↗

Visual Tool for Assessing Stability of DER Configurations on Three-Phase Radial Networks

Here, we present a method and tool for evaluating the placement of Distributed Energy Resources (DER) on distribution circuits in order to control voltages and power flows. Our previous work described Phasor-Based Control (PBC), a novel control framework where DERs inject real and reactive power to track voltage magnitude and phase angle targets. Here, we employ linearized power flow equations and integral controllers to develop a linear state space model for PBC acting on a three-phase unbalanced network. We use this model to evaluate whether a given inverter-based DER configuration admits a stable set of controller gains, which cannot be done by analyzing controllability nor by using the Lyapunov equation. Instead, we sample over a parameter space to identify a stable set of controller gains. Our stability analysis requires only a line impedance model and does not entail simulating the system or solving an optimization problem. We incorporate this assessment into a publicly available visualization tool and demonstrate three processes for evaluating many control configurations on the IEEE 123-node test feeder (123NF).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Total Power Factor Smart Contract with Cyber Grid Guard Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Wind Farm

In modern electrical grids, the numbers of customer-owned distributed energy resources (DERs) have increased, and consequently, so have the numbers of points of common coupling (PCC) between the electrical grid and customer-owned DERs. The disruptive operation of and out-of-tolerance outputs from DERs, especially owned DERs, present a risk to power system operations. A common protective measure is to use relays located at the PCC to isolate poorly behaving or out-of-tolerance DERs from the grid. Ensuring the integrity of the data from these relays at the PCC is vital, and blockchain technology could enhance the security of modern electrical grids by providing an accurate means to translate operational constraints into actions/commands for relays. This study demonstrates an advanced power system application solution using distributed ledger technology (DLT) with smart contracts to manage the relay operation at the PCC. The smart contract defines the allowable total power factor (TPF) of the DER output, and the terms of the smart contract are implemented using DLT with a Cyber Grid Guard (CGG) system for a customer-owned DER (wind farm). This article presents flowcharts for the TPF smart contract implemented by the CGG using DLT. The test scenarios were implemented using a real-time simulator containing a CGG system and relay in-the-loop. The data collected from the CGG system were used to execute the TPF smart contract. The desired TPF limits on the grid-side were between +0.9 and +1.0, and the operation of the breakers in the electrical grid and DER sides was controlled by the relay consistent with the provisions of the smart contract. The events from the real-time simulator, CGG, and relay showed a successful implementation of the TPF smart contract with CGG using DLT, proving the efficacy of this approach in general for implementing electrical grid applications for utilities with connections to customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On Distribution Grid Optimal Power Flow Development and Integration

Due to changes in electric distribution grid operation, new operation regimes have been recommended. Distribution grid optimal power flow (DOPF) has received tremendous attention in the research community, yet it has not been fully adopted across the utility industry. Our paper recognizes this problem and suggests a development and integration procedure for DOPF. We propose development of DOPF as a three step procedure of 1) processing the grid, 2) obtaining a tractable solution, and 3) implementing multiple solution algorithms and benchmarking them to improve application reliability. For the integration of DOPF, we demonstrate how a DOPF federate may be developed that can be integrated in a co-simulation environment to mimic the real-world conditions and hence improve its practicality to be deployed in the field. To demonstrate the efficacy of the proposed methods, tests on IEEE 123 bus system are performed where the usage of tractable formulation in DOPF algorithm development and its comparison to the benchmark solution are demonstrated.

Hanif, Sarmad↗

Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Risk Assessment Framework for Cyber-Physical Security in Distribution Grids with Grid-Edge DERs

Integration of inverter-based distributed energy resources (DERs) is reshaping the landscape of distribution grids to fulfill the socioeconomic, environmental, and sustainability goals. Addressing the technological challenges of DER grid integration requires an adaptive communication layer for efficient DER management and control. This transition has given rise to a cyberphysical system (CPS) architecture within the distribution system, causing new vulnerabilities for cyberphysical attacks. To better address potential threats, this paper presents a comprehensive risk assessment framework for cyberphysical security in distribution grids with grid-edge DERs. The framework incorporates a detailed CPS model accounting for dynamic DER characteristics within the distribution grid. It identifies vulnerabilities in DER communication systems, models attack scenarios, and addresses communication latency crucial for inverter control timescales. Subsequently, the quantification of attack impacts employs an attack probability model including both the vulnerability and criticality of cyber components. The proposed risk assessment framework was validated through testing on the modified IEEE 13-node and 123-node test feeders.

cyberattack↗

Optimal Voltage Control in Low-Observable Unbalanced Distribution Systems

The increased integration of distributed energy resources (DERs) in distribution systems brings both advantages and technical challenges. High levels of DERs can often cause over/under voltage problems. Classical voltage control algorithms are based on full knowledge of voltage states across all nodes in the system. However, this may not be a practical assumption since many locations in distribution systems are unobservable. Therefore, this paper proposes a new model predictive control (MPC) based control algorithm that accounts for system unobservability to efficiently eliminate voltage violations with as low as 50% fraction of observable nodes. Additionally, an analytical voltage sensitivity framework is employed to quickly determine the change in voltage states due to PV injections. The effectiveness of the proposed method is validated via simulations on the unbalanced IEEE 37 node test system.

Abujubbeh, Mohammad↗

Co-Simulation of PSS/E, OpenDSS, and PSCAD for Power Systems Stability Analysis With Inverter-Based Resources: Preprint

The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Grid-Aware Market Participation of Aggregate Flexible Resources

Increasing integration of distributed energy resources (DERs) within distribution feeders provides unprecedented flexibility at the distribution-transmission interconnection. With the new FERC 2222 order, DER aggregations are allowed to participate in energy market. To enable market participation, these virtual power plants need to provide their generation cost curves. This paper proposes efficient optimization formulations and solution approaches for the characterization of hourly as well as multi-time-step generation cost curves for a distribution system with high penetration of DERs. Network and DER constraints are taken into account when deriving these cost curves, and they enable active distribution systems to bid into the electricity market. The problems of deriving linear and quadratic cost curves are formulated as robust optimization problems and tractable reformulation/solution algorithm are developed to facilitate efficient calculations. The proposed formulations and solution algorithm are validated on a realistic test feeder with high penetration of flexible resources.

aggregated distributed energy resources↗

Cybersecurity Assessment in DER-rich Distribution Operations: Criticality Levels and Impact Analysis

The integration of distributed energy resources (DERs) in distribution networks has become a pivotal strategy for achieving decarbonization, enhancing grid resilience, and optimizing grid efficiency. Remote monitoring and control op- erations of such resources rely on a network of sensors and communication infrastructure, exposing the system to potential cyber threats. Therefore, as the deployment of DERs increases, ensuring secure monitoring and control becomes an imperative challenge. This paper utilizes real-time feeder models, which are instrumental in developing cybersecurity testbeds tailored for hardware-in-loop (HIL) systems. These models enable users to simulate cyber attacks in a real-world environment and analyze the power distribution operations during vulnerabilities. Furthermore, we discuss several practical sets of grid parameters to identify critical levels of DERs and evaluate various scenarios that simulate cyber threats on sensitive DERs. The modified IEEE 123-bus model is used as the test case for demonstrating the proposed scenarios. The findings from this study provide valuable insights into the vulnerabilities and potential consequences of cyber attacks on DERs, allowing for better mitigation strategies and improved cyber resilience in future distribution networks.

Maharjan, Manisha↗

Consensus-Based Control and Optimization of Power System Inertia

The integration of distributed energy resources (DERs), such as solar, wind, and energy storage systems, into power grids through inverter-based resources reduces power system inertia, leading to faster frequency dynamics and potential grid instability. To address this challenge, this paper proposes a distributed, consensus-based approach for the real-time control and optimization of inertia sources (synchronous generators and/or DERs) during system disturbances, enhancing both system stability and economic performance. The distributed control and optimization approach assumes each inertia source exchanges information solely with its neighbor ones, making it easily scalable to large power grid networks. The impacts of the communication connectivity among the inertia sources as well as their generation capacity limits on the distributed approach are investigated. We also demonstrate the approach’s robustness in scenarios involving communication time delays and packet losses, validating its effectiveness through numerical simulations on a 4-bus test system and a two-area 8-bus test system.

Power system inertia↗

Synchrophasors-based Master State Awareness Estimator for Cybersecurity in Power Grid: Testbed Implementation & Field Demonstration

The integration of distributed energy resources(DERs) and expansion of complex network in the distribution grid requires an advanced distributed state estimator to monitor the grid health at micro-level. The distribution state estimator will improve the situational awareness and resiliency of distributed power system. This paper proposes a synchrophasors-based master state awareness (MSA) estimator to enhance the cybersecurity in distribution grid by providing a real-time estimation of system operating states to control center operators. In this paper, the proposed MSA estimator utilizes only phasor measurements, bus magnitudes and angles, from phasor measurement units (PMUs),deployed in local substations, to estimate the system states and also detects data integrity attacks, such as load tripping attack that disconnects the load. To validate the proof of concept, we implement the proposed methodology in cyber-physical testbed environment at the Idaho National Laboratory (INL) Electric Grid Security Testbed. Further, to address the “valley of death” and support technology commercialization, field demonstration is also performed at the Critical Infrastructure Test Range Complex(CITRC) at the INL. Our experimental results reveal a promising performance in detecting load tripping attack and providing an accurate situational awareness through an alert visualization dashboard in real-time

42 ENGINEERING↗

Enhancing the Survivability of Power Systems With Grid-Edge DERs Against DoS Attacks

Power system survivability, defined as the ability of a system to maintain steady-state functionality under varying operational conditions, reflects its resilience against disturbances. While existing research primarily focuses on physical-layer disturbances, the increasing prevalence of grid-edge DERs, which are primarily used for integrating renewable energy, has significantly expanded the cyber attack surface. As a result, operational disruptions caused by cyber threats are posing significant challenges to system survivability and cannot be overlooked. To fill this gap, we redefine system survivability to incorporate the cyber layer’s status and propose a Distributionally Robust Optimization (DRO) approach to enhance power system survivability against potential cyber-physical threats. In this paper, we first analyze the operational guidelines of systems with a high penetration of DERs under various cyber network conditions and redefine survivability in this context. Next, we focus on the most common cyber threat, Denial-of-Service (DoS) attacks, and develop a corresponding attack model. This model allows for the creation of a kernel-based ambiguity set that captures attack uncertainties using historical data. Finally, we transform the proposed DRO model as a tractable optimization problem, with its solution providing an optimal cyber redundancy plan to enhance system survivability in DoS attack scenarios. Simulation results on the IEEE 13-node and 123-node test feeders demonstrate the effectiveness of our proposed model in improving system survivability. This model can also be expanded to include other types of common attacks and serve as a comprehensive planning tool to improve overall cyber physical survival of the system.

cybersecurity↗

Smart Contracts for Power Grid Applications Using the Advanced DLT Cyber Grid Guard Testbed

In this study is presented two power system applications with distributed ledger technology (DLT) and smart contracts (SC) that were assessed in a Cyber-Grid-Guard System (CGGS) advanced testbed, with protective relays, power meters, communication devices, DLT devices, synchronized time source, clock displays and real time simulator. This CGGS testbed was set in the Advanced Protection Lab, 252 lab space of the Grid Research Integration and Deployment Center (GRID- C), at Oak Ridge National Laboratory. In power grids, customer-owned distributed energy resources (DERs) are more frequent than in the past, and the numbers of points of interconnection (POI) with customer-owned DERs have increased. Disruptive operation from DERs presents a risk to grid operations, and protective relays located at the POI are used to isolate out-of-tolerance or poorly behaving of DERs. Ensuring the integrity of data from the relays at the POI, and DLT could enhance the security of the power grids. The first application is a SC to define and control the allowable total power factor (TPF) of the DER (wind farm) output, and the terms of the SC are implemented using DLT with a CGGS for a customer-owned DER. The TPF SC was implemented by the CGGS using DLT. The experimental model was performed with a real-time simulator using a CGGS and relay in-the-loop. The data collected from the CGGS were used to execute the TPF SC. The TPF limits were between +0.9 and +1.0, and the breakers’ operation in the POI was controlled by the relay using the SC. The events were collected from the real-time simulator, CGGS, and SEL 700GT relay to validate a successful application of the TPF SC using DLT. The second application is a SC to measure and control the allowable voltage service limits (VSL) by the CGGS using DLT. The tests were performed by using a real-time simulator, CGGS and relay in-the-loop. The data was collected from the CGGS that executed the SC. The main constraints were defined based on ANSI C84.1 service voltage limits, and the operation of the breakers in the POI. The events were collected from the CGGS, and SEL 700GT relay to assess a successful operation of the VSL SC using DLT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

Imaging of a van der Waals spin-orbit torque system using spin ensembles in hBN

Recently, optically active spin defects embedded in two-dimensional (2D) van der Waals (vdW) crystals have emerged as a transformative quantum sensing platform to explore cutting-edge materials science. Taking advantage of excellent solid-state integrability, this new class of spin defects can be readily arranged in nanoscale proximity to target materials, showing great promise for realizing in-situ quantum sensing of microscopic spin and charge behaviors in vdW heterostructures. Here we report hexagonal boron nitride-based quantum imaging of field-free deterministic magnetic switching and electric current distributions in an all-vdW spin-orbit torque (SOT) system. By visualizing variations of nanoscale magnetic stray field profile of room-temperature 2D magnet Fe 3 GaTe 2 under different SOT conditions, we show how the magnetic switching evolves from deterministic to stochastic behavior due to the interplay between spin orientations, anisotropy and Joule heating. Micromagnetic simulations rationalize our results well, revealing the role of field-like SOT in inhibiting thermal fluctuation driven stochastic switching and chaotic multi-domain competition. This understanding, which is otherwise difficult to access by conventional transport measurements, offers valuable insights into material design, testing, and performance evaluation of next-generation vdW spintronic devices.

Imaging techniques↗

Joint scheduling of energy, fast and primary frequency response reserves in integrated transmission–distribution networks

Inverter-based distributed energy resources (DERs) connected to distribution networks (DNs) can provide fast frequency support, but their reserve deliverability depends on feeder constraints and differs from synchronous primary frequency response (PFR). Existing transmission–distribution coordination studies usually treat reserve generically or neglect feeder-level feasibility, while frequency-security scheduling studies rarely represent distribution feeders explicitly. This paper develops a bi-level day-ahead scheduling framework for integrated transmission–distribution networks that jointly clears energy, transmission-side PFR, and distribution-side fast frequency response (FFR) under exogenous hourly inertia and largest-loss inputs from an external unit commitment (UC) schedule. The transmission problem is modeled with DC-optimal power flow (OPF) and closed-form second-order cone (SOC) frequency-security constraints, whereas each DN is represented by a reserve-aware branch-flow AC-OPF so that scheduled fast reserves remain deliverable during activation. The bi-level problem is reformulated through Karush–Kuhn–Tucker (KKT) conditions into a mixed-integer SOC program, and a penalty term is used to tighten the distribution-network relaxation. In the reduced test system, lower exogenous inertia increased the required primary response from 179.64 MW to 191.08 MW, distribution-side fast response reduced total frequency-response procurement by up to 4.9%, and neglecting distribution constraints overstated the combined distribution-side energy and reserve award by up to 18%. In the expanded study, the largest case was solved in 2.02 s with a 0.00% optimality gap. Time-domain simulations kept the frequency nadir above 59.0 Hz in all tested hours. These results demonstrate the value of fast-response modeling and distribution-feasible reserve delivery in coordinated market clearing.

Noh, Seung-Gil↗

Development and performance of high-temperature superconducting CORC ® cables with CFD REBCO tapes

Abstract Increasing the normal zone propagation velocity (NZPV) in superconducting cables based on rare earth barium copper oxide (REBCO) tapes is expected to cause a paradigm shift by enabling the development of faster and more reliable quench detection systems to mitigate the development of destructive hot spots. Furthermore, a higher NZPV is beneficial in terms of fault current limitation capabilities by accelerating the homogenization of the quench in superconducting power devices. One way envisioned to increase the NZPV of cables based on REBCO tapes is the current flow diverter (CFD) concept. A Conductor on Round Core (CORC ® ) cable made with CFD REBCO tapes, called CFD CORC ® cable, and a CORC ® cable made with regular REBCO tapes, were fabricated and tested. The critical current of the CFD and regular CORC ® cables were obtained at temperatures ranging from 67 to 77 K in self-field. Measurements showed that the NZPV was increased by a factor of 4–4.5 in the case of the CFD CORC ® cable. Furthermore, the results suggest that the NZPV depends only on the applied current, similar to what has been observed previously on single REBCO tapes. These results demonstrate the successful integration of CFD REBCO tapes in CORC ® cables, without compromising their superconducting properties or their enhanced NZPV. The possibility of enhancing the NZPV of REBCO-based cables could facilitate quench detection, which remains an important issue in HTS magnet applications. This advancement also holds promise for the fault current limitation functionality of CORC ® cables.

Ben Saâd, Haïfa (ORCID:0000000216205364)↗