Rad Hard Trusted Application Specific Integrated Circuits.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
This paper introduces how an integrated set of Systems Engineering (SE) and Project Management (PM) processes were applied in a practical way, to address the challenges on a complex, highly technical, Engineering Procurement Construction project within the nuclear field. This approach was inspired by: - the principles contained in a Community of Practice on Lean in Program Management jointly established in May 2012 by MIT, PMI and INCOSE; - an opportunity to apply international standard ISO/IEC 15288:2008(E) Systems and software engineering - System life cycle processes on a real-life situation; - and the belief that there is great value in applying Systems Engineering and Project Management in an integrated manner on a project. The project offering this opportunity was the Detail Engineering, Procurement, Construction and Cold Commissioning (EPC) of the Silo Direct-encapsulation Plant (SDP). This project was undertaken by the Joint Venture (JV) formed by Areva, Mace and Atkins (a.m.a. Nuclear Ltd). Unfortunately, early termination of the project, at a stage when only a part of the processes and tools were being implemented, did not allow this integrated approach to be demonstrated in full. However, the benefits achieved in the early stages in aligning and forming an integrated project execution team, showed potential for great benefits. This paper covers an introductory analysis of the situation, the successes and benefits achieved from implementing an integrated SE - PM approach up to the stage when the project was terminated, and possible path forward had the project continued. (authors)
The integrated CAM application for the KOMPAS-3D environment known as CNC Module for Turning is considered. This application permits automated development of control programs for numerically controlled lathes. The user may readily adapt the CAM application for specific production conditions and machine tools, thanks to features such as the following: representation of the cutting tools by means of parametric 3D models, the possibility of including fixed CNC cycles in the control programs, and the use of the Python language for programming of the postprocessors.
Several mm-wave diagnostics on the DIII-D tokamak provide multi-scale and multi-dimensional measurements of plasma profile evolution and turbulence fluctuations. Mm-wave fusion plasma diagnostics that adopt system-on-chip integrated circuit technology can provide better space utilization, flexible installation, and improved sensitivity. In order to further extend this technology for additional fusion facilities with a higher toroidal magnetic field, V-band (55–75 GHz) and F-band (90–140 GHz) chips for Microwave Imaging Reflectometer (MIR) and Electron Cyclotron Emission Imaging (ECEI) instruments are developed and tested in the Davis Millimeter Wave Research Center (DMRC). Current measurement data show that correlation between these SoC-based diagnostic instruments with other state-of-the-art diagnostics enables co-located multi-field turbulence fluctuation measurement.
Integrated technologies greatly enhance the prospects for practical quantum information processing and sensing devices based on trapped ions. High-speed and high-fidelity ion state readout is critical for any such application. Integrated detectors offer significant advantages for system portability and can also greatly facilitate parallel operations if a separate detector can be incorporated at each ion-trapping location. Here, we demonstrate ion quantum state detection at room temperature utilizing single-photon avalanche diodes (SPADs) integrated directly into the substrate of silicon ion trapping chips. Furthermore, we detect the state of a trapped Sr + ion via fluorescence collection with the SPAD, achieving 99.92(1)% average fidelity in 450 μs, opening the door to the application of integrated state detection to quantum computing and sensing utilizing arrays of trapped ions.
Carbon Storage Data Integration, Visualization and Application via EDX and GeoCube
This conference talk discusses optimizing gold-gold and gold-ENIG fine-pitch interconnections for Heterogeneous Integration applications, with a focus on longevity. We first look at electrical data from gold-gold bumps subjected to highly accelerated lifetime testing. Then, we discuss using chemical and physical data as a predictor for ENIG bump flip-chip success.
system2atoms is a suite of models that can simulate the performance of hydrogen infrastructure across multiple scales. Examples of the different scale levels include: 1. System Scale - techno-economic analysis for hydrogen applications, integration of hydrogen infrastructure with the electrical grid, and supply and demand constraints across applications 2. Component Scale - continuous-flow catalyst beds, electrochemical conversion units, gas-phase separators, pumps, compressors, storage tanks, evaporators, heaters, and coolers 3. Material Scale - surface reactions, degradation mechanisms, and catalyst poisoning
As HPC system architectures and the applications running on them continue to evolve, the MPI standard itself must evolve. The trend in current and future HPC systems toward powerful nodes with multiple CPU cores and multiple GPU accelerators makes efficient support for hybrid programming critical for applications to achieve high performance. However, the support for hybrid programming in the MPI standard has not kept up with recent trends. The MPICH implementation of MPI provides a platform for implementing and experimenting with new proposals and extensions to fill this gap and to gain valuable experience and feedback before the MPI Forum can consider them for standardization. Here, in this work, we detail six extensions implemented in MPICH to increase MPI interoperability with other runtimes, with a specific focus on heterogeneous architectures. First, the extension to MPI generalized requests lets applications integrate asynchronous tasks into MPI’s progress engine. Second, the iovec extension to datatypes lets applications use MPI datatypes as a general-purpose data layout API beyond just MPI communications. Third, a new MPI object, MPIX_Stream, can be used by applications to identify execution contexts beyond MPI processes, including threads and GPU streams. MPIX stream communicators can be created to make existing MPI functions thread-aware and GPU-aware, thus providing applications with explicit ways to achieve higher performance. Fourth, MPIX Streams are extended to support the enqueue semantics for offloading MPI communications onto a GPU stream context. Fifth, thread communicators allow MPI communicators to be constructed with individual threads, thus providing a new level of interoperability between MPI and on-node runtimes such as OpenMP. Lastly, we present an extension to invoke MPI progress, which lets users spawn progress threads with fine-grained control to adapt the communication performance to their application designs. We describe the design and implementation of these extensions, provide usage examples, and highlight their expected benefits with performance results.
Sensalert is a wearable health tracking application that enables monitoring of a target population’s health status in real-time. The application integrates health monitoring parameters from wearable sensors, e.g., temperature and heart rate, with relevant environmental parameters, e.g., weather and topography, and calculates the corresponding physiological strain index for each point in time. The objective of this application is to provide early warning, support decision making, and increase situational awareness by displaying comprehensive information and providing alerts at the right time and place. This application is the first of its kind being developed for integration into the Defense Threat Reduction Agencies Bio Surveillance Ecosystem (BSVE). We present the user requirements and design principles for developing this type of application. We hope this work helps and inspires future research in the area of wearable technologies for surveillance.
High quality-factor (Q) optical resonators are a key component for ultra-narrow linewidth lasers, frequency stabilization, precision spectroscopy and quantum applications. Integration in a photonic waveguide platform is key to reducing cost, size, power and sensitivity to environmental disturbances. However, to date, the Q of all-waveguide resonators has been relegated to below 260 Million. Here, we report a Si 3 N 4 resonator with 422 Million intrinsic and 3.4 Billion absorption-limited Qs. The resonator has 453 kHz intrinsic, 906 kHz loaded, and 57 kHz absorption-limited linewidths and the corresponding 0.060 dB m -1 loss is the lowest reported to date for waveguides with deposited oxide upper cladding. These results are achieved through a careful reduction of scattering and absorption losses that we simulate, quantify and correlate to measurements. This advancement in waveguide resonator technology paves the way to all-waveguide Billion Q cavities for applications including nonlinear optics, atomic clocks, quantum photonics and high-capacity fiber communications.
The Axom library consists of n collection of software components that provide core computer science infrastructure capabilities that can be shared by diverse high performance computing (HPC) applications. The current set of capabilities that Axom provides includes: Customizable support for error/warning and diagnostic message reporting and coordination among components of integrated applications (e.g., physics packages, libraries, etc.); Scalable parallel aggregation and filtering of message logging; In memory datastore for hierarchical, mesh-aware simulation data. The datastore supports data description, allocation, deallocation. parallel l/0, etc; Mesh data model abstractions that enable the development of mesh-based computational algorithms that work with many diverse, application· specific mesh types; and Computational geometry primitives for developing high performance parallel algorithms based on spatial geometry and meshes, e.g., spatial acceleration data structures, sets, maps, relations, etc.
Not Available
Criticality experiments are an important part of the nuclear data pipeline. A better understanding of fission (and better nuclear data) is extremely important for the nuclear industry. Criticality experiments play a role in improving this understanding.
The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.
Er{sup 3+} doped CaBi{sub 2}Ta{sub 2}O{sub 9} (CBT) bismuth layered-structure high temperature piezoelectric ceramics were synthesized by the traditional solid state method. The upconversion (UC) emission properties of Er{sup 3+} doped CBT ceramics were investigated as a function of Er{sup 3+} concentration and incident pump power. A bright green upconverted emission was obtained under excitation 980 nm at room temperature. The observed strong green and weak red emission bands corresponded to the transitions from {sup 4}S{sub 3/2} and {sup 4}F{sub 9/2} to {sup 4}I{sub 15/2}, respectively. The dependence of UC emission intensity on pumping power indicated that a three-photon process was involved in UC emissions. Studies of dielectric with temperature have also been carried out. Introduction of Er increased the Curie temperature of CBT, thus, making this ceramic suitable for sensor applications at higher temperatures. Because of its strong up-converted emission and increased Tc, the multifunctional high temperature piezoelectric ceramic may be useful in high temperature sensor, fluorescence thermometry, and optical-electro integration applications.