Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High-Q Superconducting Lumped-Element Resonators for Low-Mass Axion Searches

Low-frequency superconducting lumped-element resonators have recently attracted significant attention in the context of axion dark matter searches. Here we present the design and implementation of a fixed-frequency superconducting resonator operating near $250~\mathrm{kHz}$, possessing an inductor volume of $\sim 1$ liter and achieving an unloaded quality factor $Q \approx 2.1\times10^{6}$. This resonator represents a significant improvement over the state of the art and informs the design of searches for low-mass axions.

FOS: Physical sciences↗

SQUID Readout of a High-$Q$ Superconducting $LC$ Resonator

We demonstrate the readout of a superconducting $LC$ resonator, with $Q \approx 2 \times 10^{6}$ at approximately 250 kHz, using a dc SQUID followed by a SQUID series-array amplifier readout chain. We find that $Q$ depends on the SQUID flux-bias point, increasing near the shallow-slope point of the SQUID modulation curve and decreasing near the steep-slope point, consistent with the previously observed SQUID damping effects. From this variation, we infer the SQUID effective input impedance. We further infer the effective temperature of the resonator circuit from the resonance peak in the noise spectrum and show that it also depends on the SQUID flux-bias point, suggesting a possible contribution from SQUID back-action noise. This system provides a working prototype for future experiments based on lumped-element resonators with SQUID readout, in particular low-mass axion searches within the DMRadio program.

FOS: Physical sciences↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Neutrino Beam Monitoring

Accelerator facilities produce neutrino beams from meson decays in a decay volume. Experiments measure event rates that depend on flux, cross sections, and detector response, so the flux is predicted using hadron production and beamline modeling and constrained by beam instrumentation, since near detectors alone cannot separate flux from cross section. Proton, hadron, and muon monitors can track the parent particle distributions and beam conditions, providing the inputs needed for flux predictions in long-baseline experiments such as NOvA, T2K, and DUNE. This talk reviews how beam monitors are used in practice to understand neutrino flux. Proton beam monitors tell where the beam hits the target and how stable it is. Farther downstream, hadron and muon monitors sample particles produced in meson decays. Because those muons come from the same parents as the neutrinos, their profiles reveal focusing, alignment shifts, and other changes in the beam, and they are routinely used to detect problems and guide flux predictions. The muon information can be used more quantitatively; for example, to infer the parent meson phase space, and fast radiation-hard timing detectors can add sensitivity to the momentum dependence of the focusing. These developments show both how tightly beam measurements can constrain the flux and where the current limits still lie. These approaches complement monitored-beam concepts, in which the decay region is instrumented to detect charged leptons from meson decays and to measure the neutrino flux directly.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Neutrino Beam Monitoring

Accelerator facilities produce neutrino beams from meson decays in a decay volume. Experiments measure event rates that depend on flux, cross sections, and detector response, so the flux is predicted using hadron production and beamline modeling and constrained by beam instrumentation, since near detectors alone cannot separate flux from cross section. Proton, hadron, and muon monitors can track the parent particle distributions and beam conditions, providing the inputs needed for flux predictions in long-baseline experiments such as NOvA, T2K, and DUNE. This talk reviews how beam monitors are used in practice to understand neutrino flux. Proton beam monitors tell where the beam hits the target and how stable it is. Farther downstream, hadron and muon monitors sample particles produced in meson decays. Because those muons come from the same parents as the neutrinos, their profiles reveal focusing, alignment shifts, and other changes in the beam, and they are routinely used to detect problems and guide flux predictions. The muon information can be used more quantitatively; for example, to infer the parent meson phase space, and fast radiation-hard timing detectors can add sensitivity to the momentum dependence of the focusing. These developments show both how tightly beam measurements can constrain the flux and where the current limits still lie. These approaches complement monitored-beam concepts, in which the decay region is instrumented to detect charged leptons from meson decays and to measure the neutrino flux directly.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

The High-Altitude Water Cherenkov (HAWC) observatory in México: The primary detector

The High-Altitude Water Cherenkov (HAWC) observatory is a second-generation continuously operated, wide field-of-view, TeV gamma-ray observatory. The HAWC observatory and its analysis techniques build on experience of the Milagro experiment in using ground-based water Cherenkov detectors for gamma-ray astronomy. HAWC is located on the Sierra Negra volcano in México at an elevation of 4100 meters above sea level. The completed HAWC observatory principal detector (HAWC) consists of 300 closely spaced water Cherenkov detectors, each equipped with four photomultiplier tubes to provide timing and charge information to reconstruct the extensive air shower energy and arrival direction. The HAWC observatory has been optimized to observe transient and steady emission from sources of gamma rays within an energy range from several hundred GeV to several hundred TeV. However, most of the air showers detected are initiated by cosmic rays, allowing studies of cosmic rays also to be performed. This paper describes the characteristics of the HAWC main array and its hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-of-flight methodologies with large-area diamond detectors for the effectively characterization of tens MeV protons

A novel detector based on a polycrystalline diamond sensor is here employed in an advanced time-of-flight scheme for the characterization of energetic ions accelerated during laser-matter interactions. The optimization of the detector and of the advanced TOF methodology allow to obtain signals characterized by high signal-to-noise ratio and high dynamic range even in the most challenging experimental environments, where the interaction of high-intensity laser pulses with matter leads to effective ion acceleration, but also to the generation of strong Electromagnetic Pulses (EMPs) with intensities up to the MV/m order. These are known to be a serious threat for the fielded diagnostic systems. Here we report on the measurement performed with the PW-class laser system Vega 3 at CLPU (~30 J energy, ~10 21 W/cm 2 intensity, ~30 fs pulses) irradiating solid targets, where both tens of MeV ions and intense EMP fields were generated. The data were analyzed to retrieve a calibrated proton spectrum and in particular we focus on the analysis of the most energetic portion (E > 5.8 MeV) of the spectrum showing a procedure to deal with the intrinsic lower sensitivity of the detector in the mentioned spectral-range.

47 OTHER INSTRUMENTATION↗

Study and improvement of the trigger system in ICARUS

In recent years, intriguing experimental neutrino anomalies have emerged. If confirmed, they could hint at the presence of additional sterile neutrino states playing in neutrino mixing. The Short-Baseline Neutrino project at Fermilab aims to delve into these anomalies, utilizing three Liquid Argon Time Projection Chamber detectors along the Booster Neutrino Beam. The SBND detector serves as nearby instruments, while MicroBooNE and ICARUS function as far detectors and also explore the NuMI beam off-axis. A relevant aspect in the functioning of all SBN detectors is the trigger system, that determines which interactions are recorded. In particular, in ICARUS, it relies on the synchronization of prompt signals from scintillation light within the LAr-TPC, detected by a system of Photo-Multiplier Tubes, with the proton beam’s spill extraction. The existing majority-based logic of the trigger system could potentially be enhanced through adder boards that sum analog signals from PMTs in groups of 15. This sum-based triggering might aid in identifying events near TPC walls, where light is abundant but captured by only a few PMTs, potentially bypassing the majority condition. Comprehensive tests have been performed to characterize these adder boards.

43 PARTICLE ACCELERATORS↗

SPT-SLIM: Line Intensity Mapping with the South Pole Telescope

Line-intensity mapping (LIM) at millimeter wavelengths is a powerful emerging probe of the large-scale structure of the Universe, but achieving meaningful constraints on cosmological parameters with LIM requires focal planes with orders of magnitudes more detectors than existing instruments. SPT-SLIM is an upcoming experiment to demonstrate LIM observations of CO at 0.5 < z < 2.0 using on-chip spectrometers with kinetic inductance detectors (KIDs), a new technology that enables scaling to the much larger arrays of detectors needed to probe cosmology. I will describe the overall experimental design and specific goals of SPT-SLIM. In addition, I will highlight results of the detector and readout electronics development for SPT-SLIM and the status of the camera integration and commissioning in the lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SPT-SLIM: A Line Intensity Mapping Pathfinder for the South Pole Telescope

The South Pole Telescope Summertime Line Intensity Mapper (SPT-SLIM) is a pathfinder experiment that will demonstrate the use of on-chip filter-bank spectrometers for mm-wave line intensity mapping. The SPT-SLIM focal plane consists of 18 dual-polarization filter-bank spectrometers covering 120–180 GHz with resolving power of 300, coupled to aluminum kinetic inductance detectors. A compact cryostat holds the detectors at 100 mK. SPT-SLIM will be deployed to the 10-m South Pole Telescope for observations during the 2023–2024 austral summer without removing the primary receiver. We discuss the overall instrument design, expected detector performance, and sensitivity to the carbon monoxide line signal at $0.5< z < 2$. The technology and observational techniques demonstrated by SPT-SLIM will enable next-generation line intensity mapping experiments that constrain cosmology beyond the redshift reach of galaxy surveys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors

We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of ℱ avg =99.93%. All of the schematics, firmware, and software are open-source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studying AC-LGAD strip sensors from laser and testbeam measurements

Here, this paper presents the setup assembled to characterize and measure the spatial and timing resolutions of AC-coupled Low Gain Avalanche Diodes (AC-LGADs), using a 1060 nm laser source to deposit initial charges with a defined calibration methodology. The results were compared to those obtained with a 120 GeV proton beam. Despite the differences in the charge deposition mechanism between the laser and proton beam, the spatial and temporal resolutions were found to be compatible between the two sources after calibration. With 4D tracking detectors expected to play a vital role in upcoming collider experiments, we foresee this work as a way to evaluate the performance of semiconductor sensors that can augment testbeam measurements and accelerate R&D efforts. Additionally, simulation studies using Silvaco TCAD and Weightfield2 were carried out to understand the various contributing factors to the total time resolution in AC-LGAD sensors, measured using the laser source.

FOS: Physical sciences↗

Secondary scintillation properties of multi-layer THGEMs operated in low-pressure CF 4 and Ar/5%Xe

We present a measurement of the secondary scintillation yield produced by two-layer Thick Gas Electron Multipliers (M-THGEMs) in pure Tetrafluoromethane (CF 4 ) gas and in Ar mixed with 5% Xe in low-pressures down to 20 Torr. The detector was irradiated with 5.49 MeV alpha particles from a low-rate 241-Am source. The secondary scintillation light generated during the gas avalanche process was read out by a Hamamatsu photomultiplier tube (model R8520-406), sensitive to a broad wavelength range (160–650 nm). The avalanche charge was collected on the bottom electrode of M-THGEM and correlated to the scintillation light on an event-by-event basis. We observed that, for both gas types, the value of the photon to electron production ratio (0.4 ph/el in CF 4 and 0.1 ph/el in Ar/5%Xe) increases with the thickness of the M-THGEM electrodes and varies significantly with the pressure, being higher at lower values. The decrease in electroluminescence yield at higher pressures is much more pronounced in the Ar/Xe mixture. In addition, because of a larger gas avalanche volume, the electroluminescence light yield is larger in thicker M-THGEM structures. Presented results are particularly useful for designing the next generation of Optical-readout Time Projection Chambers (O-TPCs) operated at low-pressure CF 4 ; applications include experimental nuclear physics with rare isotope beams, dark matter detection with directional sensitivity and observation of the Migdal effect in a low-pressure Optical TPC.

47 OTHER INSTRUMENTATION↗

Neutron Detectors for Scattering Applications

The book covers, for the first time, the most common neutron detectors used in neutron scattering facilities and all of those in use at Oak Ridge National Lab. The first two chapters describe the facilities, instruments and the critical detector parameters needed by various instruments. The third chapter focuses on the key components of the 3He-based linear position sensitive detectors as well as on their electronics, which require particular attention to signal-processing and noise reduction. The fourth chapter is dedicated to the 3He alternatives where scintillators play a critical role. Finally, chapter 5 covers emerging neutron detection technologies including semiconductors, vacuum-based devices and their associated readouts, which will be required in the future for high rate and high-resolution neutron detectors.

Diawara, Yacouba↗

Snowmass Instrumentation Frontier IF08 Topical Group Report: Noble Element Detectors

Particle detectors making use of noble elements in gaseous, liquid, or solid phases are prevalent in neutrino and dark matter experiments and are also used to a lesser extent in collider-based particle physics experiments. These experiments take advantage of both the very large, ultra-pure target volumes achievable and the multiple observable signal pathways possible in noble-element based particle detectors. As these experiments seek to increase their sensitivity, novel and improved technologies will be needed to enhance the precision of their measurements and to broaden the reach of their physics programs. The areas of R&D in noble element instrumentation that have been identified by the HEP community in the Snowmass process are highlighted by five key messages: IF08-1) Enhance and combine existing modalities (scintillation and electron drift) to increase signal-to-noise and reconstruction fidelity; IF08-2) Develop new modalities for signal detection in noble elements, including methods based on ion drift, metastable fluids, solid-phase detectors and dissolved targets. Collaborative and blue-sky R&D should also be supported to enable advances in this area; IF08-3) Improve the understanding of detector microphysics and calibrate detector response in new signal regimes; IF08-4) Address challenges in scaling technologies, including material purification, background mitigation, large-area readout, and magnetization; and IF08-5) Train the next generation of researchers, using fast-turnaround instrumentation projects to provide the design-through-result training no longer possible in very-large-scale experiments. This topical group report identifies and documents recent developments and future needs for noble element detector technologies. In addition, we highlight the opportunity that this area of research provides for continued training of the next generation of scientists.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MATHUSLA: An External Long-Lived Particle Detector to Maximize the Discovery Potential of the HL-LHC

We present the current status of the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle (LLP) detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA40 is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close proximity to the CMS interaction point and about 100 m of rock shielding from LHC backgrounds allows it to detect LLP production rates and lifetimes that are one to two orders of magnitude beyond the ultimate reach of the LHC main detectors. This provides unique sensitivity to many LLP signals that are highly theoretically motivated, due to their connection to the hierarchy problem, the nature of dark matter, and baryogenesis. Data taking is projected to commence with the start of HL-LHC operations. We summarize the new 40m design for the detector that was recently presented in the MATHUSLA Conceptual Design Report, alongside new realistic background and signal simulations that demonstrate high efficiency for the main target LLP signals in a background-free HL-LHC search. We argue that MATHUSLA's uniquely robust expansion of the HL-LHC physics reach is a crucial ingredient in CERN's mission to search for new physics and characterize the Higgs boson with precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual Design Report for the MATHUSLA Long-Lived Particle Detector near CMS

We present the Conceptual Design Report (CDR) for the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close proximity to the CMS interaction point and about 100 m of rock shielding from HL-LHC backgrounds allows it to detect LLP production rates and lifetimes that are one to two orders of magnitude beyond the ultimate sensitivity of the HL-LHC main detectors for many highly motivated LLP signals. Data taking is projected to commence with the start of HL-LHC operations. We present a new 40m design for the detector: its individual scintillator bars and wavelength-shifting fibers, their organization into tracking layers, tracking modules, tower modules and the veto detector; define a high-level design for the supporting electronics, DAQ and trigger system, including supplying a hardware trigger signal to CMS to record the LLP production event; outline computing systems, civil engineering and safety considerations; and present preliminary cost estimates and timelines for the project. We also conduct detailed simulation studies of the important cosmic ray and HL-LHC muon backgrounds, implementing full track/vertex reconstruction and background rejection, to ultimately demonstrate high signal efficiency and $\ll 1$ background event in realistic LLP searches for the main physics targets at MATHUSLA. This sensitivity is robust with respect to detector design or background simulation details. Appendices provide various supplemental information.

Aitken, Branden [Victoria U.]↗

Opportunities and challenges to study solar neutrinos with a Q-Pix pixel readout

The study of solar neutrinos presents significant opportunities in astrophysics, nuclear physics, and particle physics. However, the low-energy nature of these neutrinos introduces considerable challenges to isolate them from background events, requiring detectors with low-energy threshold, high spatial and energy resolutions, and low data rate. We present the study of solar neutrinos with a kiloton-scale liquid argon detector located underground, instrumented with a pixel readout using the Q-Pix technology. We explore the potential of using volume fiducialization, directional topological information, light signal coincidence, and pulse-shape discrimination to enhance solar neutrino sensitivity. We find that discriminating neutrino signals below 5 MeV is very difficult. However, we show that these methods are useful for the detection of solar neutrinos when external backgrounds are sufficiently understood and when the detector is built using low-background techniques. When building a workable background model for this study, we identify 𝛾 background from the cavern walls and from capture of 𝛼 particles in radon decay chains as both critical to solar neutrino sensitivity and significantly underconstrained by existing measurements. Finally, we highlight that the main advantage of the use of Q-Pix for solar neutrino studies lies in its ability to enable the continuous readout of all low-energy events with minimal data rates and manageable storage for further off-line analyses.

multi-purpose particle detectors↗