Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Commodity-Free Calibration

Commodity-free calibration is a reaction rate calibration technique that does not require the addition of any commodities. This technique is a specific form of the reaction rate technique, where all of the necessary reactants, other than the sample being analyzed, are either inherent in the analyzing system or specifically added or provided to the system for a reason other than calibration. After introduction, the component of interest is exposed to other reactants or flow paths already present in the system. The instrument detector records one of the following to determine the rate of reaction: the increase in the response of the reaction product, a decrease in the signal of the analyte response, or a decrease in the signal from the inherent reactant. With this data, the initial concentration of the analyte is calculated. This type of system can analyze and calibrate simultaneously, reduce the risk of false positives and exposure to toxic vapors, and improve accuracy. Moreover, having an excess of the reactant already present in the system eliminates the need to add commodities, which further reduces cost, logistic problems, and potential contamination. Also, the calculations involved can be simplified by comparison to those of the reaction rate technique. We conducted tests with hypergols as an initial investigation into the feasiblility of the technique.

Source record↗

Precipitating Electron Energy Flux and Characteristic Energies in Jupiter's Main Auroral Region as Measured by Juno/JEDI

The relationship between electron energy flux and the characteristic energy of electron distributions in the main auroral loss cone bridges the gap between predictions made by theory and measurements just recently available from Juno. For decades such relationships have been inferred from remote sensing observations of the Jovian aurora, primarily from the Hubble Space Telescope, and also more recently from Hisaki. However, to infer these quantities, remote sensing techniques had to assume properties of the Jovian atmospheric structure - leading to uncertainties in their profile. Juno's arrival and subsequent auroral passes have allowed us to obtain these relationships unambiguously for the first time, when the spacecraft passes through the auroral acceleration region. Using Juno /Jupiter Energetic particle Detector Instrument (JEDI), an energetic particle instrument, we present these relationships for the 30-kiloelectronvolts to 1-megaelectronvolts electron population. Observations presented here show that the electron energy flux in the loss cone is a nonlinear function of the characteristic or mean electron energy and supports both the predictions from Knight (1973, https://doi.org/10.1016/0032-0633(73)90093-7) and magnetohydrodynamic turbulence acceleration theories (e.g., Saur et al., 2003, https://doi.org/10.1029/2002GL015761). Finally, we compare the in situ analyses of Juno with remote Hisaki observations and use them to help constrain Jupiter's atmospheric profile. We find a possible solution that provides the best agreement between these data sets is an atmospheric profile that more efficiently transports the hydrocarbons to higher altitudes. If this is correct, it supports the previously published idea (e.g., Parkinson et al., 2006, https://doi.org/10.1029/2005JE002539) that precipitating electrons increase the hydrocarbon eddy diffusion coefficients in the auroral regions.

Auroral↗

Direct-Write Printing on Three-Dimensional Geometries for Miniaturized Detector and Electronic Assemblies

Aerosol Jet Printing (AJP) and other additive electronics technologies will enable new detector assemblies that were not previously possible with traditional assembly processes. This technology has the potential to reduce mass and volume for fabrication and assembly of detector, instrument and electronics concepts by reducing trace widths down to 10 microns, printing on complex geometries, and allowing new concept production. This poster summarizes development efforts of printed interconnects for space applications.

Printed Hybrid Electronics↗

Principal Component Analysis of Up-The-Ramp Sampled Infrared Array Data

We describe the results of principal component analysis (PCA) of up-the-ramp sampled infrared (IR) array data from the Hubble Space Telescope wide field camera 3 (WFC3 IR), James Webb Space Telescope NIRSpec, and prototype Wide Field Infrared Survey Telescope’s wide field instrument detectors. These systems use, respectively, Teledyne H1R, H2RG, and H4RG-10 near-IR detector arrays with a variety of IR array controllers. The PCA shows that the Legendre polynomials approximate the principal components of these systems (i.e., they roughly diagonalize the covariance matrix). In contrast to the monomial basis that is widely used for polynomial fitting and linearization today, the Legendre polynomials are an orthonormal basis. They provide a quantifiable, compact, and (nearly) linearly uncorrelated representation of the information content of the data. By fitting a few Legendre polynomials, nearly all of the meaningful information in representative WFC3 astronomical datacubes can be condensed from 15 up-the-ramp samples down to 6 compressible Legendre coefficients per pixel. The higher order coefficients contain time domain information that is lost when one projects up-the-ramp sampled datacubes onto two-dimensional images by fitting a straight line, even if the data are linearized before fitting the line. Going forward, we believe that this time domain information is potentially important for disentangling the various nonlinearities that can affect IR array observations, i.e., inherent pixel nonlinearity, persistence, burn in, brighter-fatter effect, (potentially) nonlinear interpixel capacitance, and perhaps others.

Rauscher, Bernard J.↗

Near-Infrared Single-Photon-Counting Detectors for Laser Instrument Applications at NASA Goddard Space Flight Center

We discuss single-photon-counting detectors requirements for NASA remote sensing and communications systems. We present experimental measurements on several different near-infrared single-photon-counting detectors including InGaAs/InP and InGaAs/InAlAs avalanche photodiodes (APD), an InGaAsP photocathode hybrid photomultiplier (PMT) and an InGaAs photomultiplier. We present the experimental performance of prototype instruments for laser ranging, communication, and trace-gas detection that use these detectors.

Krainak, Michael A.↗

Instrumentation in astronomy VII; Proceedings of the Meeting, Tucson, AZ, Feb. 13-17, 1990

The topics discussed include IR detectors and instrumentation, detectors, other instrumentation, optical instrumentation, and space instrumentation. Papers are presented on the IR spectrometer/imager for the ESO VLT, the fiber-coupled high-resolution IR array spectrometer for the Kuiper Airborne Observatory, the Balloon-Borne Infrared Telescope for FIR spectroscopy, and a simple transputer-based CCD camera controller. Attention is given to CCD guidance system for William Herschel Telescope, the New Technology Telescope control/acquisition system as a prototype for the VLT, a control system for spincasting 8-m borosilicate honeycomb mirrors, echelle spectrographs for 8-m class telescopes, and fiber spectroscopy at Palomar Observatory. Other papers are on the Kitt Peak National Observatory fiber actuator device, a two-star photoelectric photometer, an ultrahigh-resolution XUV spectroheliograph, an optical monitor for X-ray satellites, and large-format electrographic and array detectors for a space Schmidt imaging telescope.

Crawford, David L.↗

The Cusp Plasma Imaging Detector (Cupid) Cubesat Observatory: Instrumentation

The Cusp Plasma Imaging Detector (CuPID) CubeSat observatory is a 6U CubeSat designed to observe solar wind charge exchange in magnetospheric cusps to test competing theories of magnetic reconnection at the Earth’s magnetopause. The CuPID is equipped with three instruments, namely, a wide field-of-view (4.6° × 4.6°) soft x-ray telescope, a micro-dosimeter suite, and an engineering magnetometer optimized for the science operation. The instrument suite has been tested and calibrated in relevant environments, demonstrating successful design. The testing and calibration of these instruments produced metrics and coefficients that will be used to create the CuPID mission’s data product.

Magnetospheric dynamics↗

LOITA: Lunar Optical/Infrared Telescope Array

LOITA (Lunar Optical/Infrared Telescope Array) is a lunar-based interferometer composed of 18 alt-azimuth telescopes arranged in a circular geometry. This geometry results in excellent uv coverage and allows baselines up to 5 km long. The angular resolution will be 25 micro-arcsec at 500 nm and the main spectral range of the array will be 200 to 1100 nm. For infrared planet detection, the spectral range may be extended to nearly 10 mu m. The telescope mirrors have a Cassegrain configuration using a 1.75 m diameter primary mirror and a 0.24 m diameter secondary mirror. A three-stage (coarse, intermediate, and fine) optical delay system, controlled by laser metrology, is used to equalize path lengths from different telescopes to within a few wavelengths. All instruments and the fine delay system are located within the instrument room. Upon exiting the fine delay system, all beams enter the beam combiner and are then directed to the various scientific instruments and detectors. The array instrumentation will consist of CCD detectors optimized for both the visible and infrared as well as specially designed cameras and spectrographs. For direct planet detection, a beam combiner employing achromatic nulling interferometry will be used to reduce star light (by several orders of magnitude) while passing the planet light. A single telescope will be capable of autonomous operation. This telescope will be equipped with four instruments: wide field and planetary camera, faint object camera, high resolution spectrograph, and faint object spectrograph. These instruments will be housed beneath the telescope. The array pointing and control system is designed to meet the fine pointing requirement of one micro-arcsec stability and to allow precise tracking of celestial objects for up to 12 days. During the lunar night, the optics and the detectors will be passively cooled to 70-80 K temperature. To maintain a continuous communication with the earth a relay satellite placed at the L4 libration point will be used in conjunction with the Advanced Tracking and Data Relay Satellite System (ATDRSS). Electrical power of about 10 kW will be supplied by a nuclear reactor based on the SP-100 technology. LOITA will be constructed in three phases of six telescopes each. The total mass of the first operational phase is estimated at 58,820 kg. The cost of the fully operational first phase of the observatory is estimated at $8.9 billion. LOITA's primary objectives will be to detect and characterize planets around nearby stars (up to ten parsec away), study physics of collapsed stellar objects, solar/stellar surface features and the processes in nuclear regions of galaxies and quasars. An interferometric array such as LOITA will be capable of achieving resolutions three orders of magnitude greater than Hubble's design goal. LOITA will also be able to maintain higher signal to noise ratios than are currently attainable due to long observation times available on the moon.

Source record↗

Background Count Rates and the Anti-Coincidence Detector on the Instrument on Astro-E2

Minimum ionizing particles incident on the XRS microcalorimeter array will deposit energy in the pixels on the same scale as an x-ray photon and would be confused with x-rays without an anti-coincidence detector. The XRS anti-coincidence detector is a silicon ionization detector placed directly behind the calorimeter array. Given an isotropic particle flux, 98% of those particles that pass through a calorimeter pixel will also deposit energy in the anti-coincidence detector. Particle events that are not rejected by coincidence are those that pass through at small angles relative to the plane of the array, and thus deposit more energy. Modeling with GEANT4 showed that only 0.1% of all protons incident on the array miss the anti-coincidence detector yet deposit less than 10 keV in a pixel. The unrejected background will thus be dominated by secondary events; we will provide an estimate of this rate. Protons incident on the thick silicon frame around the active area of the array deposit enough energy t o heat the whole chip slightly. This results in small simultaneous pulses on multiple pixels. These can be easily rejected by pixel-to-pixel coincidence. We will discuss the impact of these events on the instrument dead time and will present the expected rate. We will present laboratory background data demonstrating the performance of the anti-coincidence detector and the effectiveness of coincidence analysis in the laboratory environment.

Kilbourne, C. A.↗

Detectors and Focal Plane Modules for Weather Instruments

Weather satellite instruments require detectors with a variety of wavelengths ranging from the visible to VLWIR. The Cross-track infrared Sounder (CrIS) is a Polar Orbiting interferometric sensor that measures earth radiances at high spectral resolution, using the data to provide pressure, temperature and moisture profiles of the atmosphere. The pressure, temperature and moisture sounding data are used in weather prediction models that track storms, predict levels of precipitation etc. The CrIS instrument contains SWIR (lambda(sub c) (is) approximately 5 micrometers at 98 K), MWIR (lambda(sub c) (is) approximately 9 micrometers at 98 K) and LWIRs (lambda(sub c) (is) approximately 15.4 m at 81 K) bands in three Focal Plane Array Assemblies (FPAAs). CrIS detectors are 850 micrometers diameter detectors with each FPAA consisting of nine photovoltaic detectors arranged in a 3 x 3 pattern. Molecular beam epitaxy (MBE)-grown Hg1-xCdxTe material are used for the detectors fabricated in a modified Double Layer Planar Heterostructure (DLPH) architecture. Each detector has an accompanying cold preamplifier. SWIR and MWIR FPAAs operate at 98 K and the LWIR FPAA at 81 K, permitting the use of passive radiators to cool the detectors. D* requirements at peak 14.01 micrometers wavelength are greater than 5.0E+10 Jones for LWIR, greater than 7.5E+10 Jones at 8.26 micrometers for MWIR and greater than 3.0E+11 Jones at peak 4.64 micrometers wavelength for SWIR. All FPAAs exceeded the D* requirements. Measured mean values for the nine photodiodes in each of the LWIR, MWIR and SWIR FPAAs are D* = 5.3 x 10(exp 10) cm-Hz1/2/W at 14.0 micrometers, 9.6 x 10(exp 10) cm-Hz1/2/W at 8.0 micrometers and 3.4 x 10(exp 11) cm-Hz1/2/W at 4.64 micrometers.

satellite instruments↗

Temperature control analysis and flight results for the Viking Orbiter 1975 Mars atmospheric water detection instrument

The Mars atmospheric water detector (MAWD) instrument required a temperature of -70 C at the detector. The monochromator housing required +20 C + or - 1 C. This instrument was located on the scan platform, and slewed across two solar panels. The thermal design for the detector was an open flat plate radiator thermally isolated on four 1-in. tubes, with a flexible strap to the detector. MAWD radiator view factors and heat loads from the spacecraft were determined for the Lander on and off, for all angular positions of the scan platform. Subsystem and system tests were performed using the 25-ft diameter solar simulator. In-flight results have shown no anomalies, and no degradation has been observed. Servo-controlled heaters are used to control the temperature.

Kavanagh, H. M.↗

Hydrogen Distribution in the Lunar Polar Regions

We present a method of conversion of the lunar neutron counting rate measured by the Lunar Reconnaissance Orbiter (LRO) Lunar Exploration Neutron Detector (LEND) instrument collimated neutron detectors, to water equivalent hydrogen (WEH) in the top approximately 1 m layer of lunar regolith. Polar maps of the Moon’s inferred hydrogen abundance are presented and discussed.

Sanin, A. B.↗

Science Instrument Sensitivities to Radioisotope Power System Environment

Radioisotope Power Systems (RPS) have been and will be enabling or significantly enhancing for many missions, including several concepts identified in the 2011 Planetary Science Decadal Survey. Some mission planners and science investigators might have concerns about possible impacts from RPS-induced conditions upon the scientific capabilities of their mission concepts. To alleviate these concerns, this paper looks at existing and potential future RPS designs, and examines their potential radiation, thermal, vibration, electromagnetic interference (EMI), and magnetic fields impacts on representative science instruments and science measurements. Radiation impacts from RPS on science instruments are of potential concern for instruments with optical detectors and instruments with high-voltage electronics. The two main areas of concern are noise effects on the instrument measurements, and long-term effects of instrument damage. While RPS by their nature will contribute to total radiation dose, their addition for most missions should be relatively small. For example, the gamma dose rate from one Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) would be an order of magnitude lower than the environmental dose rate at Mars, and would have a correspondingly lower contribution to instrument noise and to any permanent damage to payload sensors. Increasing the number of General Purpose Heat Source (GPHS) modules used in an RPS would be expected to increase the generated radiation proportionally; however, the effect of more GPHS modules is mitigated from a strictly linear relationship by self-shielding effects. The radiation field of an RPS is anisotropic due to the deviation of the modules from a point-source-geometry. For particularly sensitive instruments the total radiation dose could be mitigated with separation or application of spot shielding. Though a new, higher-power RPS could generate more heat per unit than current designs, thermal impact to the flight system could be mitigated with shading and pointing if required by the mission. Alternatively, excess heat could prove beneficial in providing needed heat to spacecraft components and instruments in some thermal environments. Vibration for a new higher-power Stirling Radioisotope Generator (SRG) would be expected to be similar to the recent Advanced Stirling Radioisotope Generator (ASRG) design. While vibration should be low, it must be considered and addressed during spacecraft and instrument design. EMI and magnetic fields for new RPS concepts are expected to be low as for the current RPS, but must be considered and addressed if the mission includes sensitive instruments such as magnetometers. The assessment conducted for this paper focused on orbiter instrument payloads for two representative mission concepts- a Titan Saturn System Mission (TSSM) and a Uranus Orbiter and Probe (UOP)-since both of these Decadal Survey concepts would include many diverse instruments on board. Quick-look design studies using notional new RPS concepts were carried out for these two mission concepts, and their specific instrument packages were analyzed for their interactions with new RPS designs. The original Decadal Survey TSSM and UOP concepts did not have complete instrument performance requirements so typical measurement requirements were used where needed. Then, the general RPS environments were evaluated for impacts to various types of instruments. This paper describes how the potential impacts of the RPS on science instruments and measurements were assessed, which impacts were addressed, proposed mitigation strategies against those impacts, and provides an overview of future work.

RPS↗

The Signs of Life Detector (SOLID): An Instrument to Detect Molecular Biosignatures on Mars

The case for life on Mars grows stronger. Investigations at Gale Crater by Curiosity have revealed fine-grained sedimentary rocks inferred to represent an ancient lake environment suited to support life. In addition, Curiosity tentatively found a heterogeneous distribution of organic carbon within these sediments, consistent with the detection of native organic C in Mars meteorites. Furthermore, modern potentially habitable environments have been recognized on Mars including the N. Polar region visited by Phoenix, gully features suggesting modern water flows, and RSLs that occur seasonally suggest liquid processes. The time is ripe for missions to Mars incorporating a search for biochemical evidence of life.

The SOLID Instrument↗

Detector needs for STS instruments

This white paper contains an analysis of the requirements for the detectors for the initial suite of neutron scattering instruments at the Second Target Station, STS. The detector technologies proposed are compared with the instrument requirements, in-house proficiencies and strengths, and where appropriate, expertise at other facilities. Where relevant, alternative detector options are proposed. The performance gaps between the current state-of-the-art and the required characteristics are identified and projects within the R&D program are proposed in order to close these gaps. Further, neutron beam monitor needs are considered in a similar light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flame Detector

Scientific Instruments, Inc. has now developed a second generation, commercially available instrument to detect flames in hazardous environments, typically refineries, chemical plants and offshore drilling platforms. The Model 74000 detector incorporates a sensing circuit that detects UV radiation in a 100 degree conical field of view extending as far as 250 feet from the instrument. It operates in a bandwidth that makes it virtually 'blind' to solar radiation while affording extremely high sensitivity to ultraviolet flame detection. A 'windowing' technique accurately discriminates between background UV radiation and ultraviolet emitted from an actual flame, hence the user is assured of no false alarms. Model 7410CP is a combination controller and annunciator panel designed to monitor and control as many as 24 flame detectors. *Model 74000 is no longer being manufactured.

Source record↗

Use of Diffusion Bonded Cu Strap and Integrated MLI for Thermal Control of 100 K IR Detector on L’Ralph Instrument

Passive cooling of cryogenic instruments is one of the most challenging aspects of spaceflight thermal control systems. They are highly sensitive to parasitic heat leaks from their warmer environment, especially the spacecraft components. The L’Ralph instrument on the Lucy mission is an example of such a system, with its LEISA detector requiring passive cooling to temperatures below 112 K. MLI performance can be measured in terms of estar, and analysts apply bias between a high and low estar value. This approach works well for conventional MLI at room temperature, however, it can be dangerous when a mission goes through a wide range of temperatures during its lifetime, with estar values increasing exponentially as temperatures get colder. Various estar correlations are presented as well as how L’Ralph is approaching the MLI problem with the use of IMLI. IMLI uses discrete spacers to isolate each layer, and doesn’t require intermediate layers such as dacron netting. This results in estar performance that can be more precisely estimated, and yields valuesaround 0.004 at the 112K operating temperature. L’Ralph is using IMLI on the backside of the radiator, which permits a more effective use of increased radiator area, by minimizing the area dependent heat leak impact from the instrument backloading. The detector is thermally coupled to the radiator via a diffusion bonded Cu strap. The diffusion bonding process chemically bonds the Cu foil ends in order to maximize heat transfer effectiveness across the multiple foils used. Employing a pressure compensation design via the use of Ti blocks and a clamp at the strap ends ensures that as temperatures go colder, pre-load is maintained in order to minimize resistance at the strap ends. The use of both of these technologies, and how they work together are crucial to the success of the L’Ralph thermal control system.

Thermal↗