Stability and control of power systems with high penetrations of inverter-based resources: An accessible review of current knowledge and open questions

As power system renewable energy penetrations increase, the ways in which key renewable technologies such as wind and solar photovoltaics (PV) differ from thermal generators become more apparent. Many studies have examined the variability and uncertainty of such generators and described how generation and load can be balanced for a wide variety of annual energy penetrations, at timescales from seconds to years. Another important characteristic of these resources is asynchronicity, the result of using inverters to interface the prime energy source with the power system as opposed to synchronous generators. Unlike synchronous generators, whose frequency of alternating current (AC) injection is physically coupled to the rotation of the machine itself, inverter based asynchronous generators do not share the same physical coupling with the generated frequency. These subtle differences impact the operations of power systems developed around the characteristics of synchronous generators. In this paper we review current knowledge and open research questions concerning the interplay between asynchronous inverter-based resources (IBRs) and cycle- to second-scale power system dynamics, with a focus on how stability and control may be impacted or need to be achieved differently when there are high instantaneous penetrations of IBRs across an interconnection. This work does not seek to provide a comprehensive review of the latest developments, but is instead intended to be accessible to any reader with an engineering background and an interest in power systems and renewable energy. As such, the paper includes basic material on power electronics, control schemes for IBRs, and power system stability; and uses this background material to describe potential impacts of IBRs on power system stability, operational challenges associated with large amounts of distributed IBR generation, and modern power system simulation trends driven by IBR characteristics.

14 SOLAR ENERGY↗

Root Cause Analysis of AC Overcurrent in July 2020 San Fernando Disturbance

On July 7 2020, approximately 1,000 MW reduction in solar photovoltaic (PV) output was experienced by the bulk power system in Southern California after a three-phase fault. Disturbance analysis indicates that instantaneous AC current caused inverter tripping. The projection of the root cause of AC overcurrent from the NERC report is that inverter current control is not tight. This letter provides a quantitative analysis on ac overcurrent and addresses the following questions: (i) what type of current controls may lead to ac overcurrent; and (ii) how controller parameters and grid strength influence ac overcurrent. Here, the letter provides frequency-domain analysis and time-domain simulation results of a grid-integrated inverter to illustrate the effect of control parameters and grid strength on ac overcurrent.

14 SOLAR ENERGY↗

Blocking Simulations in GFDL GCMs for CMIP5 and CMIP6

Abstract The frequency of atmospheric blocking has been largely underestimated by general circulation models (GCMs) participating in the Coupled Model Intercomparison Project (CMIP). Errors in the onset, persistence, barotropicity, geographical preference, seasonality, intensity, and moving speed of global blocking were diagnosed in 10 Geophysical Fluid Dynamics Laboratory (GFDL) GCMs for recent CMIP5 and CMIP6 using a detection approach that combines zonal eddies and the reversal of zonal winds. The blocking frequency, similar at 500 and 250 hPa, is underestimated by 50% in the Atlantic–Europe region during December–February but is overestimated by 60% in the Pacific–North America region during that season and by 70% in the southwest Pacific during July–August. These blocking biases at 500 hPa were investigated in the five CMIP6 models that showed improvements over the CMIP5 versions. The Atlantic–Europe underestimate corresponds to lower instantaneous blocking rates, lower persistent blocking rates, and higher persistent stationary ridge rates; the number of blocks with a duration of 4–5 days is only 40%–65% of that in observations. In contrast, the overestimate consists of excessive blocks with a duration longer than 12 days in the Pacific–North America and up to twice as many 4–6-day events in the southwest Pacific. Simulated December–February blocks up to 12 days in the Pacific–North America region tend to be stronger and to move more slowly than those in observations. Diagnostic sensitivity tests indicated that the zonal mean and zonal eddy components of the mean state play a key role, as replacing each with that of observations substantially reduced many of the outstanding biases in these GCMs.

54 ENVIRONMENTAL SCIENCES↗

A fast and large bandwidth superconducting variable coupler

Variable microwave-frequency couplers are highly useful components in classical communication systems and likely will play an important role in quantum communication applications. Conventional semiconductor-based microwave couplers have been used with superconducting quantum circuits, enabling, for example, the in situ measurements of multiple devices via a common readout chain. However, the semiconducting elements are lossy and furthermore dissipate energy when switched, making them unsuitable for cryogenic applications requiring rapid, repeated switching. Superconducting Josephson junction-based couplers can be designed for dissipation-free operation with fast switching and are easily integrated with superconducting quantum circuits. These enable on-chip, quantum-coherent routing of microwave photons, providing an appealing alternative to semiconductor switches. Here, we present and characterize a chip-based broadband microwave variable coupler, tunable over 4-8GHz with over 1.5GHz instantaneous bandwidth, based on the superconducting quantum interference device with two parallel Josephson junctions. The coupler is dissipation-free and features large on-off ratios in excess of 40dB, and the coupling can be changed in about 10ns. The simple design presented here can be readily integrated with superconducting qubit circuits and can be easily generalized to realize a four- or more port device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant

As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.

14 SOLAR ENERGY↗

Pellet triggering of edge localized modes in low collisionality pedestals at DIII-D

Edge localized modes (ELMs) are triggered using deuterium pellets injected into plasmas with ITER-relevant low collisionality pedestals, and the resulting peak ELM energy fluence is reduced by approximately 25%–50% relative to natural ELMs destabilized at similar pedestal pressures. Cryogenically frozen deuterium pellets are injected from the low-field side of the DIII-D tokamak at frequencies lower than the natural ELM frequency, and heat flux is measured by infrared cameras. Ideal MHD pedestal stability calculations show that without pellet injection, these low collisionality pedestals were limited by their current density (peeling-limited) rather than their pressure gradient (ballooning-limited). ELM triggering success correlates strongly with pellet mass, consistent with the theory that a large pressure perturbation is required to trigger an ELM in low collisionality discharges that are far from the ballooning stability boundary. For sufficiently large pellets, both instantaneous and time-integrated ELM energy deposition measured by infrared cameras is reduced with respect to naturally occurring ELMs at the inner strike point, which is the position where it is largest for natural ELMs. Energy fluence at the outer strike point is less effected. Cameras observing both heat flux and D-alpha emission often find significant toroidally asymmetric striations in the outboard far scrape-off layer resulting from ELMs that are triggered by pellets. Toroidal asymmetries at the inner strike point are similar between natural and pellet-triggered ELMs, indicating that the reduction in peak heat flux and total fluence at that location is robust for the conditions reported here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical investigation of the influence of shear and thermal stratification on the wind turbine tip‐vortex stability

Summary The interaction between wind turbine wakes and atmospheric turbulence is characterised by complex dynamics. In this study, two major components of the atmospheric boundary layer dynamics have been isolated, namely, the mean velocity profile shear and the thermal stratification, to examine their impact on the near‐wake development by undertaking a series of highly resolved large‐eddy simulations. Subsequently, instantaneous flow fields are extracted from the simulations and used to conduct Fourier analysis and proper orthogonal decomposition (POD) and compute the mean kinetic energy fluxes by different POD modes to better understand the tip‐vortex instability mechanisms. Our findings indicate that shear can significantly affect the breakup of the wind turbine tip‐vortices and the shape and stable length of the wake, whereas thermal stratification seems to only have limited contribution to the spatial development of the near‐wake field. Finally, our analysis shows that the applied perturbation frequency determines the tip‐vortex breakup location as it controls the onset of the mutual inductance instability.

17 WIND ENERGY↗

Tunable semiconductor laser with two acousto-optic tunable filters in its external cavity

We report a laser with a linear external cavity containing a near-IR injection semiconductor optical amplifier as a gain element and two acousto-optic tunable filters (AOTFs) with quasi-collinear interaction of acoustic and light waves. At identical frequencies of RF signals that control the filters and ensure compensation for the Doppler frequency shift of light passing through the AOTFs, the steady-state laser emission linewidth can be reduced to about 25 MHz, which is almost three orders of magnitude smaller than that in the case of one filter (20 GHz). The position of the emission line, which remains narrow, slowly fluctuates within a spectral range about 3 GHz wide, which seems to be due to the large length of the external cavity and insufficient thermal stabilization of its components. This does not prevent us from obtaining light with a large coherence length. In emission wavelength sweep mode, the instantaneous emission linewidth increases with tuning rate, reaching 0.022 nm (8.8 GHz) at the highest tuning rate: 10{sup 4} nm s{sup −1}. In the case of automatic control over the output optical power at a level of 3 mW, the tuning range is 815 – 875 nm. Such instruments are of practical interest for optical coherence tomography, spectroscopy, optical metrology, and other application areas. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent Hydrodynamic Modeling Enhancements in OpenFAST

To improve the hydrodynamic modeling capabilities of the offshore wind design and modeling tool OpenFAST, a restructuring of the HydroDyn hydrodynamics module was undertaken with several new features implemented. The generation of the wave field is now separated from HydroDyn into a new module called SeaState. Unlike previous versions of HydroDyn, which precomputed the wave kinematics at the undisplaced positions of the hydrodynamic nodes, the new SeaState module computes the complete time history of the wave field at the vertices of a user-defined wave grid. During the simulation, the wave kinematics at any point within the grid can be efficiently interpolated, allowing the strip-theory wave loads to be evaluated based on the wave kinematics at the displaced structure position. A phase correction was also implemented for the potential-flow wave-exciting loads to account for large structure displacements. Several wave-stretching methods were implemented for the strip-theory solution along with a wave-load redistribution method that ensures smooth variation of the nodal loads as the nodes of a discrete hydrodynamic mesh enter and exit the water. The load smoothing is included to avoid the excitation of unphysical high-frequency structural vibration during hydroelastic simulations. The MacCamy-Fuchs diffraction correction for the strip-theory solution and the capability to insert a constrained NewWave into extreme stochastic sea states with directional spreading were also added. The present article documents the formulations of the new improvements to HydroDyn with example applications and numerical results.

constrained wave↗

Recent Hydrodynamic Modeling Enhancements in OpenFAST: Preprint

To improve the hydrodynamic modeling capabilities of the offshore wind design and modeling tool OpenFAST, a restructuring of the HydroDyn hydrodynamics module was undertaken with several new features implemented. The generation of the wave field is now separated from HydroDyn into a new module called SeaState. Unlike previous versions of HydroDyn, which precomputed the wave kinematics at the undisplaced positions of the hydrodynamic nodes, the new SeaState module computes the complete time history of the wave field at the vertices of a user-defined wave grid. During the simulation, the wave kinematics at any point within the grid can be efficiently interpolated, allowing the strip-theory wave loads to be evaluated based on the wave kinematics at the displaced structure position. A phase correction was also implemented for the potential-flow wave-exciting loads to account for large structure displacements. Several wave-stretching methods were implemented for the strip-theory solution along with a wave-load redistribution method that ensures smooth variation of the nodal loads as the nodes of a discrete hydrodynamic mesh enter and exit the water. The load smoothing is included to avoid the excitation of unphysical high-frequency structural vibration during hydroelastic simulations. The MacCamy-Fuchs diffraction correction for the strip-theory solution and the capability to insert a constrained NewWave into extreme stochastic sea states with directional spreading were also added. The present article documents the formulations of the new improvements to HydroDyn with example applications and numerical results.

constrained wave↗

Initial Characterization of the NREL Large-Amplitude Motion Platform

The Large Amplitude Motion Platform (LAMP) at NREL represents a significant advancement in the controlled testing of Wave Energy Converters (WECs) under laboratory conditions. Originally designed by E2M as a six-degree-of-freedom (DOF) Stewart platform for flight simulation, LAMP has been adapted by NREL to facilitate the mounting and evaluation of WECs. This adaptation enables dry testing of WECs using motion profiles similar to the ocean, facilitating the iterative design, testing, and validation of WEC performance prior to ocean deployments. This report presents the initial work completed to characterize LAMP, with particular emphasis on its stability and operational capabilities across various single and multi-degree-of-freedom (DOF) motion profiles. The report includes planned comparisons at three distinct mass payloads, aimed at assessing the platform's positional accuracy, frequency response, and endurance over extended runtime periods. These experimental tests are critical for establishing the platform's limitations and ensuring that the data generated during WEC validation is both accurate and reproducible. The outcomes of this study not only contribute to a deeper understanding of LAMP's capabilities but also lay the groundwork for future advancements in WEC testing methodologies. By providing robust and reliable performance data within a controlled laboratory setting, the findings are expected to significantly enhance the development and commercialization of marine energy technologies. This report presents the initial findings of the LAMP Characterization work and proposed steps to further understand and characterize LAMP. Data collected during this work can be found on MHKDR at: https://mhkdr.openei.org/submissions/602 Note that this report shares the measured/found instantaneous maximum operating range of LAMP. For most applications the maximum operating range cannot be used for system health and longevity. The operating range and capabilities of LAMP will be evaluated on a case-by-case basis, single-DOF position, velocity, and acceleration values presented in Table 4a-c, and Table 5 should be taken as instantaneous absolute maximum values. Future use of LAMP will likely be limited to smaller values.

16 TIDAL AND WAVE POWER↗

Using a Grid-Forming Inverter to Stabilize a Low-Inertia Power System - Maui Hawaiian Island

As power systems around the world integrate greater amounts of wind and solar photovoltaic power, periods of very high instantaneous power shares of inverters, the primary interfacing technology for these generation sources, are complicating system stability and control. The contemporary, primary mode of inverter operation, grid-following, which explicitly assumes the presence of a local, stable voltage waveform, yields operational inadequacy at high instantaneous power shares potentially leading to instability due to the low-inertia conditions, as well as the correlated reduced voltage forming capacity on the respective system. Parallel connected grid-forming inverters, which directly regulate the local voltage, are a solution that is expected to bolster system stability and mitigate the shortcomings of the grid-following technology. In this paper, grid-following and two types of grid-forming inverter control, the traditional linear droop and the recently introduced nonlinear exponential droop (Droop-e), are simulated on a low-inertia, H = 0.48s, high inverter-based resource scenario, 97%, with a validated electromagentic transient domain model of the Hawaiian island of Maui power system. The benefit of a single grid-forming device over its grid-following counterpart is significant, both in terms frequency deviation and voltage stability. Further, the superiority of the Droop-e and the associated secondary power sharing control over both grid-following and linear droop grid-forming technologies is displayed, with improved nadir and rate of change of frequency over the linear droop control.

droop control↗

Flow structures of the cross-flow over a five-layer helically coiled steam generator geometry

The helically-coiled heat exchanger (HCSG) offers advantages over straight tubes such as compactness in geometry, increased heat transfer coefficients, and capability to absorb thermal expansion. In this study, the time-resolved velocity field data of shell-side crossflow over a five-layer helically coiled steam generator geometry was obtained using Particle Image Velocimetry (PIV) between adjacent rods in four regions with up to 5000 frames per second (5 kHz) at approximately Re u = 3600. The slant rod bundle created different flow patterns in different regions. Proper Orthogonal Decomposition (POD) revealed high-energy-mode flow structures. Due to the confined flow channel geometry, the large flow structures were not advected resulting in no strong POD mode paring. Continuous Wavelet Transform (CWT) visualized the characteristics of flow fluctuation in time and frequency domain simultaneously, which ranged in Strouhal number, S u , between 0.03 and 1.17. In the wake regions of the rods, flows changed in both pattern and magnitude over time. Once a pattern formed, it continued for relatively shorter than straight tube arrays, before changing the pattern again. The histograms of the POD time coefficients presented this multimodal flow characteristics. The current study focuses more on whole flow field analyses in the selected regions rather than local point-wise analyses. Finally, this study revealed that various Strouhal numbers can exist in the helically coiled heat exchanger geometry, which was not observed in straight tube arrays. In particular, Strouhal numbers smaller than 0.1 do not seem to be caused by vortex shedding but seem to be the result of the combination of complex geometry and possible multimodal trends. Based on the current observation, further works would involve intensive instantaneous point-wise analyses on the interactions between important locations such as separation points, stagnation points, shear layers, etc.

42 ENGINEERING↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated vehicle microscopic energy consumption study (AV-Micro): Data collection and model development

While the Adaptive Cruise Control (ACC) system in automated vehicles (AVs) is expected to impact transportation energy significantly, existing AV energy consumption models only directly adopt those developed with Human-driven Vehicle (HV) data without even slight adaptation or calibration to accommodate unique AV energy consumption features. This study will investigate how accurately HV data-based models can predict the energy consumption of AVs. Empirical trajectory data and corresponding instantaneous energy consumption rates from both AVs and HVs were collected. We adopted two classical HV data-based models to fit these data. The calibration results indicated that these models yield around 20 30% prediction errors for AVs. To further improve the prediction accuracy, this study designed an AV-Micro model by incorporating components of multiple classic energy consumption models that better capture ACC energy consumption features, including piecewise driving behavior. With this, the AV-Micro model achieves lower than 10% prediction errors. The AV-Micro model’s high consistency across different test runs was verified with statistical significance tests, demonstrating its adaptability in different driving profiles. To confirm the discrepancies between the energy consumption features of AVs and HVs, more statistical significance tests were conducted to show that the AV-Micro model cannot be directly applied to HV data. The findings by calibrated AV-Micro models revealed that AVs consume approximately 80.5–146.4 J more energy than HVs for each meter traveled. Furthermore, the frequency analysis of energy consumption indicates that there is still some room for AVs to improve energy efficiency, particularly given their larger amplitude high-frequency fluctuations.

33 ADVANCED PROPULSION SYSTEMS↗

A scale-wise analysis of intermittent momentum transport in dense canopy flows

We investigate the intermittent dynamics of momentum transport and its underlying time scales in the near-wall region of the neutrally stratified atmospheric boundary layer in the presence of a vegetation canopy. This is achieved through an empirical analysis of the persistence time scales (periods between successive zero-crossings) of momentum flux events, and their connection to the ejection–sweep cycle. Using high-frequency measurements from the GoAmazon campaign, spanning multiple heights within and above a dense canopy, the analysis suggests that, when the persistence time scales ( $t_p$ ) of momentum flux events from four different quadrants are separately normalized by $\varGamma _{w}$ (integral time scale of the vertical velocity), their distributions $P(t_p/\varGamma _{w})$ remain height-invariant. This result points to a persistent memory imposed by canopy-induced coherent structures, and to their role as an efficient momentum-transporting mechanism between the canopy airspace and the region immediately above. Moreover, $P(t_p/\varGamma _{w})$ exhibits a power-law scaling at times $t_{p}<\varGamma _{w}$ , with an exponential tail appearing for $t_{p} \geq \varGamma _{w}$ . By separating the flux events based on $t_p$ , we discover that around 80 % of the momentum is transported through the long-lived events ( $t_{p} \geq \varGamma _{w}$ ) at heights immediately above the canopy, while the short-lived ones ( $t_{p} < \varGamma _{w}$ ) only contribute marginally ( $\approx 20\,\%$ ). To explain the role of instantaneous flux amplitudes in momentum transport, we compare the measurements with newly developed surrogate data and establish that the range of time scales involved with amplitude variations in the fluxes tends to increase as one transitions from within to above the canopy.

Mechanics↗

Mean-field equation for phase-modulated optical parametric oscillator

The widely established techniques for the generation of ultrashort optical pulses rely on passive mode locking of lasers, with the output pulse duration and emission spectrum determined by the intrinsic lifetime of laser transition in the gain medium. Due to the instantaneous nature of nonlinear gain, optical parametric oscillators (OPOs) are capable of generating optical radiation in all timescales from continuous-wave (cw) to ultrashort femtosecond regime, if driven by laser pump sources in the corresponding time domain. In the ultrashort timescale, operation of OPOs conventionally relies on mode-locked pump lasers, with the concomitant disadvantages of large footprint and high cost. At the same time, the lack of gain storage mandates the use of synchronous pumping, resulting in increased complexity. In this paper, we present the concept of phase-modulated OPO driven by cw pump laser. The approach overcomes the traditional drawbacks of ultrafast OPOs, enabling femtosecond pulse generation without the need for synchronous pumping, resulting in a simplified, compact, and cost-effective architecture using cw input pump lasers. We derive a mean-field equation for a degenerate χ ( 2 ) OPO driven by a cw laser with intracavity electro-optic modulator (EOM), and also including dispersion compensation. The equation predicts the formation of stable femtosecond pulses ( < 200 fs ) , in both normal and anomalous dispersion regimes, with a controllable repetition rate determined by the frequency of the EOM. The remarkable functionality of the proposed scheme paves the way for the development of an alternative class of widely tunable coherent femtosecond light sources in both bulk and integrated format based on χ ( 2 ) OPOs using cw pump lasers. Published by the American Physical Society 2024

Sanchez, A. D. (ORCID:0000000327630339)↗

Research Roadmap on Grid-Forming Inverters

This research roadmap is intended to fill the knowledge gap by providing a system view of grid-forming inverter-based resource controls and their impact on grid stability, which we believe is central to meeting some of the challenges to operating the future North American electric power system. This includes the roles and requirements of grid-forming inverter-based resources—including solar photovoltaics, wind generators, and energy storage. For this roadmap, we focus on a specific family of grid-forming inverter control approaches that do not rely on an external voltage source (i.e., no phase-locked loop) and that can share load without explicit communications. Although the roadmap is focused narrowly on system challenges for grid-forming controls and power system stability, including interactions with protection, we hope it serves as a foundational element for future system-of-systems roadmapping needed in a broader grid modernization effort with increasing deployments of inverter-based resources. The roadmap first introduces formal definitions for the grid stability topics and then describes the differences between grid-forming and traditional grid-following control approaches for inverter-based resources. The core of the roadmap consists of a review of current research and an outline of research needs related to five grid-forming inverter topics: frequency control, voltage control, system protection, fault ride-through and voltage recovery, and modeling and simulation. The review both delineates contemporary advances and highlights open research questions that must be addressed to enable the widespread adoption of inverter-based resources across the grid. Feedback from industry on these research questions is incorporated, including discussions during the Workshop on Grid-forming Inverters for Low-inertia Power Systems. The workshop included industry presentations and discussion of ongoing research, technology gaps, and piloting needs. This roadmap concludes by offering a multiyear perspective on the gradual field validation of grid-forming inverters. This perspective recognizes that the scale and scope of the types of power systems that inverters will be called on to provide grid-forming services will and should begin modestly. Specifically, this roadmap recognizes that inverter controls today are predominantly grid-following and that future power systems will involve a mix of inverter-based resources with both grid-following and grid-forming control capabilities. Growth over time will depend on how well grid-forming inverters perform and what advantages they bring as penetration levels (instantaneous and average) of inverter-based resources increases. This recognition, in turn, establishes a natural sequence of priorities for the research questions that must be addressed. Following this multiyear perspective, the roadmap offers short descriptions of two specific near-term research priorities: the review of regulatory and technical standards and the development of advanced modeling techniques. These priorities are foundational. We recommend immediate pursuit of them in parallel with and in direct support of the research outlined by our multiyear perspective.

24 POWER TRANSMISSION AND DISTRIBUTION↗