Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Index of Refraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Long period grating refractive-index sensor: optimal design for single wavelength interrogation

We report the design criteria for the use of long period gratings (LPGs) as refractive-index sensors with output power at a single interrogating wavelength as the measurement parameter. The design gives maximum sensitivity in a given refractive-index range when the interrogating wavelength is fixed. Use of the design criteria is illustrated by the design of refractive-index sensors for specific application to refractive-index variation of a sugar solution with a concentration and detection of mole fraction of xylene in heptane (paraffin).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple scattering of matter waves: An analytic model of the refractive index for atomic and molecular gases

We present an analytic model of the refractive index for matter waves propagating through atomic or molecular gases. The model, which combines the Wentzel-Kramers-Brillouin (WKB) treatment of the long-range attraction with the Fraunhofer model treatment of the short-range repulsion, furnishes a refractive index in compelling agreement with recent experiments of Jacquey et al. [Phys. Rev. Lett. 98, 240405 (2007)] on Li atom matter waves passing through dilute noble gases. We show that the diffractive contribution, which arises from scattering by a two-dimensional 'hard core' of the potential, is essential for obtaining a correct imaginary part of the refractive index.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determining thickness and refractive index from free-standing ultra-thin polymer films with spectroscopic ellipsometry

It is a well-known challenge to determine refractive index (n) from ultra-thin films where the thickness is less than about 10 nm. In this paper, we discovered an interesting exception to this issue while characterizing spectroscopic ellipsometry (SE) data from isotropic, free-standing polymer films. Ellipsometry analysis shows that both thickness and refractive index can be independently determined for free-standing films as thin as 5 nm. Simulations further confirm an orthogonal separation between thickness and index effects on the experimental SE data. Effects of angle of incidence and wavelength on the data and sensitivity are discussed. Finally, while others have demonstrated methods to determine refractive index from ultra-thin films, our analysis provides the first results to demonstrate high-sensitivity to the refractive index from ultra-thin layers.

36 MATERIALS SCIENCE↗

Temperature-dependent Absolute Refractive Index Measurements of Synthetic Fused Silica

Using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have measured the absolute refractive index of five specimens taken from a very large boule of Corning 7980 fused silica from temperatures ranging from 30 to 310 K at wavelengths from 0.4 to 2.6 microns with an absolute uncertainty of plus or minus 1 x 10 (exp -5). Statistical variations in derived values of the thermo-optic coefficient (dn/dT) are at the plus or minus 2 x 10 (exp -8)/K level. Graphical and tabulated data for absolute refractive index, dispersion, and thermo-optic coefficient are presented for selected wavelengths and temperatures along with estimates of uncertainty in index. Coefficients for temperature-dependent Sellmeier fits of measured refractive index are also presented to allow accurate interpolation of index to other wavelengths and temperatures. We compare our results to those from an independent investigation (which used an interferometric technique for measuring index changes as a function of temperature) whose samples were prepared from the same slugs of material from which our prisms were prepared in support of the Kepler mission. We also compare our results with sparse cryogenic index data from measurements of this material from the literature.

Leviton, Douglas B.↗

Giant Modulation of Refractive Index from Picoscale Atomic Displacements

Abstract It is shown that structural disorder—in the form of anisotropic, picoscale atomic displacements—modulates the refractive index tensor and results in the giant optical anisotropy observed in BaTiS 3 , a quasi‐1D hexagonal chalcogenide. Single‐crystal X‐ray diffraction studies reveal the presence of antipolar displacements of Ti atoms within adjacent TiS 6 chains along the c ‐axis, and threefold degenerate Ti displacements in the a – b plane. 47/49 Ti solid‐state NMR provides additional evidence for those Ti displacements in the form of a three‐horned NMR lineshape resulting from a low symmetry local environment around Ti atoms. Scanning transmission electron microscopy is used to directly observe the globally disordered Ti a–b plane displacements and find them to be ordered locally over a few unit cells. First‐principles calculations show that the Ti a – b plane displacements selectively reduce the refractive index along the ab ‐plane, while having minimal impact on the refractive index along the chain direction, thus resulting in a giant enhancement in the optical anisotropy. By showing a strong connection between structural disorder with picoscale displacements and the optical response in BaTiS 3 , this study opens a pathway for designing optical materials with high refractive index and functionalities such as large optical anisotropy and nonlinearity.

36 MATERIALS SCIENCE↗

Refractive index of r-cut sapphire under shock pressure range 5 to 65 GPa

High-pressure refractive index of optical window materials not only can provide information on electronic polarizability and band-gap structure, but also is important for velocity correction in particle-velocity measurement with laser interferometers. In this work, the refractive index of r-cut sapphire window at 1550 nm wavelength was measured under shock pressures of 5–65 GPa. The refractive index (n) decreases linearly with increasing shock density (ρ) for shock stress above the Hugoniot elastic limit (HEL): n = 2.0485 (± 0.0197) − 0.0729 (± 0.0043)ρ, while n remains nearly a constant for elastic shocks. This behavior is attributed to the transition from elastic (below HEL) to heterogeneous plastic deformation (above HEL). Based on the obtained refractive index-density relationship, polarizability of the shocked sapphire was also obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-organization of dissipationless solitons in positive- and negative-refractive-index materials

A generalized Ginzburg-Landau equation describing dissipative solitons dynamics in negative-refractive-index materials is derived from Maxwell equations. This equation having only real terms with opposite sign differs from the usual Ginzburg-Landau equation for positive-refractive-index media. A cross-compensation between the saturating nonlinearity excess, losses, and gain makes obtained self-organized solitons dissipationless and exceptionally robust. In the presence of such solitons medium becomes effectively dissipationless. The compensation of losses is of particular interest for media with resonant character of interactions like negative-refractive-index materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of the complex refractive index and size distribution of atmospheric particulates from bistatic-monostatic lidar and solar radiometer measurements

A method is presented for inferring both the size distribution and the complex refractive index of atmospheric particulates from combined bistatic-monostatic lidar and solar radiometer observations. The basic input measurements are spectral optical depths at several visible and near-infrared wavelengths as obtained with a solar radiometer and backscatter and angular scatter coefficients as obtained from a biostatic-monostatic lidar. The spectral optical depth measurements obtained from the radiometer are mathematically inverted to infer a columnar particulate size distribution. Advantage is taken of the fact that the shape of the size distribution obtained by inverting the particulate optical depth is relatively insensitive to the particle refractive index assumed in the inversion. Bistatic-monostatic angular scatter and backscatter lidar data are then processed to extract an optimum value for the particle refractive index subject to the constraint that the shape of the particulate size distribution be the same as that inferred from the solar radiometer data. Specifically, the scattering parameters obtained from the bistatic-monostatic lidar data are compared with corresponding theoretical computations made for various assumed refractive index values. That value which yields best agreement, in a weighted least squares sense, is selected as the optimal refractive index estimate. The results of this procedure applied to a set of simulated measurements as well as to measurements collected on two separate days are presented and discussed.

Reagan, J. A.↗

Very High Refractive Index Transition Metal Dichalcogenide Photonic Conformal Coatings by Conversion of ALD Metal Oxides

Materials for nanophotonic devices ideally combine ease of deposition, very high refractive index, and facile pattern formation through lithographic templating and/or etching. In this work, we present a scalable method for producing high refractive index WS 2 layers by chemical conversion of WO 3 synthesized via atomic layer deposition (ALD). These conformal nanocrystalline thin films demonstrate a surprisingly high index of refraction (n > 3.9), and structural fidelity compatible with lithographically defined features down to ~10 nm. Although this process yields highly polycrystalline films, the optical constants are in agreement with those reported for single crystal bulk WS 2 . Subsequently, we demonstrate three photonic structures - first, a two-dimensional hole array made possible by patterning and etching an ALD WO 3 thin film before conversion, second, an analogue of the 2D hole array first patterned into fused silica before conformal coating and conversion, and third, a three-dimensional inverse opal photonic crystal made by conformal coating of a self-assembled polystyrene bead template. Furthermore these results can be trivially extended to other transition metal dichalcogenides, thus opening new opportunities for photonic devices based on high refractive index materials.

36 MATERIALS SCIENCE↗

An insight into statistical refractive index properties of cell internal structure via low-coherence statistical amplitude microscopy

Refractive index properties, especially at the nanoscale, have shown great potential in cancer diagnosis and screening. Due to the intrinsic complexity and weak refractive index fluctuation, the reconstruction of internal structures of a biological cell has been challenging. In this paper, we propose a simple and practical approach to derive the statistical properties of internal refractive index fluctuations within a biological cell with a new optical microscopy method – Low-coherence Statistical Amplitude Microscopy (SAM). We validated the capability of SAM to characterize the statistical properties of cell internal structures, which is described by numerical models of one-dimensional Gaussian random field. We demonstrated the potential of SAM in cancer detection with an animal model of intestinal carcinogenesis – multiple intestinal neoplasia mouse model. We showed that SAM-derived statistical properties of cell nuclear structures could detect the subtle changes that are otherwise undetectable by conventional cytopathology.

59 BASIC BIOLOGICAL SCIENCES↗

Full field imaging based instantaneous hyperspectral absolute refractive index measurement

Multispectral refractometers typically measure refractive index (RI) at discrete monochromatic wavelengths via a serial process. We report on the demonstration of a white light full field imaging based refractometer capable of instantaneous multispectral measurement of absolute RI of clear liquid/gel samples across the entire visible light spectrum. The broad optical bandwidth refractometer is capable of hyperspectral measurement of RI in the range 1.30 1.70 between 400nm 700nm with a maximum error of 0.0036 units (0.24% of actual) at 414nm for a = 1.50 sample. We present system design and calibration method details as well as results from a system validation sample.

99 GENERAL AND MISCELLANEOUS↗

Uncladded sensing fiber for refractive index measurement

The formation of chemically etched optical fiber for use in refractive index sensor is addressed. This presented design of a refractive index (RI) sensor is based on recording the power loss exhibited by radiation propagating through an etched multimode fiber (MMF) immersed in the liquid under study. The decreasing diameters of fibers are found to be strongly dependent on the temperature and etchant composition. This experiment was performed for different unclad etched fibers for same sensing length and the RI changes from 1.33 RIU to 1.38 RIU. When the multimode fiber (MMF) is etched for 12 hours the sensitivity of the sensor is approximately 204.25dBm/RIU, which is larger than without etched fiber having sensitivity 127.2dBm/RIU.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Negative refractive index designed in a periodic composite of lossy microplasmas and microresonators

A novel metamaterial with negative refractive index was designed using a spatially periodic composite of microplasmas and microresonators. Microresonators, which are double-helix metal wires in this report, work as an origin of macroscopic negative permeability material, as well as discharge electrodes. If a resonance frequency of the resonators is well below electron plasma frequency of the microplasmas where their permittivity is negative in the real part with a certain imaginary part, the macroscopic refractive index becomes negative just above the resonance frequency where the macroscopic permeability is negative, even if microplasmas are fairly lossy; due to such a loss or conductive component in permittivity, electromagnetic waves are not evanescent but propagating. This result indicates that plasmas can play important roles in parameter control of a metamaterial with a complex refractive index.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extrinsic fiber-optic Fabry-Perot interferometer sensor for refractive index measurement of optical glass

A simple fiber-optic sensor based on Fabry-Perot interference for refractive index measurement of optical glass is investigated both theoretically and experimentally. A broadband light source is coupled into an extrinsic fiber Fabry-Perot cavity formed by the surfaces of a sensing fiber end and the measured sample. The interference signals from the cavity are reflected back into the same fiber. The refractive index of the sample can be obtained by measuring the contrast of the interference fringes. The experimental data meet with the theoretical values very well. The proposed technique is a new method for glass refractive index measurement with a simple, solid, and compact structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous Retrieval of Effective Refractive Index and Density from Size Distribution and Light Scattering Data: Weakly-Absorbing Aerosol

We propose here a novel approach for retrieving in parallel the effective density and real refractive index of weakly absorbing aerosol from optical and size distribution measurements. Here we define “weakly absorbing” as aerosol single-scattering albedos that exceed 0.95 at 0.5 um.The required optical measurements are the scattering coefficient and the hemispheric backscatter fraction, obtained in this work from an integrating nephelometer. The required size spectra come from a Scanning Mobility Particle Sizer and an Aerodynamic Particle Sizer. The performance of this approach is first evaluated using a sensitivity study with synthetically generated but measurement-related inputs. The sensitivity study reveals that the proposed approach is robust to random noise; additionally the uncertainties of the retrieval are almost linearly proportional to the measurement errors, and these uncertainties are smaller for the real refractive index than for the effective density. Next, actual measurements are used to evaluate our approach. These measurements include the optical, microphysical, and chemical properties of weakly absorbing aerosol which are representative of a variety of coastal summertime conditions observed during the Two-Column Aerosol Project (TCAP; http://campaign.arm.gov/tcap/). The evaluation includes calculating the root mean square error (RMSE) between the aerosol characteristics retrieved by our approach, and the same quantities calculated using the conventional volume mixing rule for chemical constituents. For dry conditions (defined in this work as relative humidity less than 55%) and sub-micron particles, a very good (RMSE~3%) and reasonable (RMSE~28%) agreement is obtained for the retrieved real refractive index (1.49±0.02) and effective density (1.68±0.21), respectively. Our approach permits discrimination between the retrieved aerosol characteristics of sub-micron and sub-10micron particles. The evaluation results also reveal that the retrieved density and refractive index tend to decrease with an increase of the relative humidity.

density↗

Low refractive index OLEDs for practical high-efficiency outcoupling. Final report

Improving OLED light extraction is a significant on-going challenge for the OLED lighting industry. The goal of this program was to explore the potential to improve internal light extraction in a manufacturable way by lowering the refractive index of the OLED stack through dilution with an electrically-inert, low refractive index molecule. We accomplished this goal, identifying a small molecule that can be co-evaporated in the hole transport layer of OLEDs at high loading to reduce the refractive index by 0.2-0.3 refractive index units without degrading charge transport. Implementing this dilution molecule in the hole transport layer of a range of single and multi-stack OLEDs, we demonstrated the ability to improve their internal light extraction by up to ~35% without increasing their drive voltage or reducing their operational lifetime. Importantly, these findings extend to state-of-the-art device architectures with proprietary OLED materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cryogenic Temperature-dependent Refractive Index Measurements of N-BK7, BaLKN3, and SF15 for NOTES PDI

In order to enable high quality lens designs using N-BK7, BaLKN3, and SF15 at cryogenic temperatures, we have measured the absolute refractive index of prisms of these three materials using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, as a function of both wavelength and temperature. For N-BK7, we report absolute refractive index and thermo-optic coefficient (dn/dT) at temperatures ranging from 50 to 300 K at wavelengths from 0.45 to 2.7 micrometers; for BaLKN3 we cover temperatures ranging from 40 to 300 K and wavelengths from 0.4 to 2.6 micrometers; for SF15 we cover temperatures ranging from 50 to 300 K and wavelengths from 0.45 to 2.6 micrometers. We compare our measurements with others in the literature and provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures. While we generally find good agreement (plus or minus 2 x 10(exp -4) for N-BK7, less than 1 x 10(exp -4) for the other materials) at room temperature between our measured values and those provided by the vendor, there is some variation between the datasheets provided with the prisms we measured and the catalog values published by the vendor. This underlines the importance of measuring the absolute refractive index of the material when precise knowledge of the refractive index is required.

Frey, Bradley J.↗

Spatial variation of stratospheric aerosol acidity and model refractive index - Implications of recent results

Recent experimental results indicate that little or no solid ammonium sulfate is present in background stratospheric aerosols. Other results allow straightforward calculation of sulfuric acid/water droplet properties (acidity, specific gravity, refractive index) as functions of stratospheric temperature and humidity. These results are combined with a variety of latitudinal and seasonal temperature and humidity profiles to obtain corresponding profiles of droplet properties. These profiles are used to update a previous model of stratospheric aerosol refractive index. The new model retains the simplifying approximation of vertically constant refractive index in the inner stratosphere, but has sulfuric acid/water refractive index values that significantly exceed the previously used room temperature values. Mean conversion ratios (e.g., extinction-to-number, backscatter-to-volume) obtained using Mie scattering calculations with the new refractive indices are very similar to those obtained for the old indices, because the effects of deleting ammonium sulfate and increasing acid indices tend to cancel each other.

Russell, P. B.↗