Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Incident response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of an energy-dependent instrument response function to analysis of nTOF data from cryogenic DT experiments

Neutron time-of-flight (nTOF) detectors are used to diagnose the conditions present in inertial confinement fusion (ICF) experiments and basic laboratory physics experiments performed on an ICF platform. The instrument response function (IRF) of these detectors is constructed by convolution of two components: an x-ray IRF and a neutron interaction response. The shape of the neutron interaction response varies with incident neutron energy, changing the shape of the total IRF. Analyses of nTOF data that span a broad range of energies must account for this energy-dependence in order to accurately infer plasma parameters and nuclear properties in ICF experiments. This work briefly reviews a matrix multiplication approach to convolution which allows for an energy-dependent change in the shape of the IRF. This method is applied to synthetic data resembling symmetric cryogenic DT implosions to examine the effect of the energy-dependent IRF on the inferred areal density. Here, results of forward fits that infer ion temperatures and areal densities from nTOF data collected during cryogenic DT experiments on OMEGA are also discussed.

47 OTHER INSTRUMENTATION↗

FRMAC Assessment Manual Volume 1 - Assessment Division Operations

In the event of a major radiological incident or accident, the Federal Radiological Monitoring and Assessment Center (FRMAC) will coordinate the federal agencies that have various statutory responsibilities and/or capabilities for responding to such incidents (Ref. FRMAC10). The FRMAC is responsible for coordinating all environmental radiological monitoring, sampling, and assessment activities for the response. For less severe radiological incidents, elements of the Department of Energy (DOE) Consequence Management (CM) program, such as the CM Response Team (CMRT) or CM Home Team (CMHT) may be activated to provide similar support activities to regional or local response assets. This manual describes the roles and responsibilities of the Assessment Division of the FRMAC during a response to a radiological incident. Every effort will be made in this manual in accordance with the Implementation of the National Incident Management System (NIMS)/Incident Command System (ICS) in the Federal Radiological Monitoring and Assessment Center (FRMAC) – Emergency Phase (Ref. RSL07) to use terminology consistent with the National Incident Management System (NIMS) for Incident Command System (ICS) organizations, planning processes, and leadership positions (Ref. FEMA17). This manual also applies to smaller scale CM responses that may involve the CMRT or CMHT elements without the formation of a FRMAC. It details the concept of operations for the Assessment Division, including common tasks performed by the Division. This manual also describes the organizational structure of the Assessment Division and roles of the personnel within the Division.

61 RADIATION PROTECTION AND DOSIMETRY↗

Response of CR-39 nuclear track detectors to protons with non-normal incidence

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV–2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter–energy relation can be fit with the existing models at angles up to 30° . The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

47 OTHER INSTRUMENTATION↗

Response of CR-39 nuclear track detectors to protons with non-normal incidence

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV–2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter–energy relation can be fit with the existing models at angles up to 30°. The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Case Study in Assessing a Potential Severity Framework for Incidents from a Decadal Sample

In this study, the primary objective of this case study is to determine the applicability and feasibility of a framework that leverages occupational incident details to prospectively identify “potential Serious Injury or Fatality” (pSIF) cases. This study comprehensively reviewed a random sample of 1,081 injury and illness cases across 21 generalized incident types spanning over a decade at Lawrence Livermore National Laboratory (LLNL), a U.S. Department of Energy research and development facility with more than 9,000 employees. The review applied a general framework that classified each case on information suitability, potential severity, and future incident mitigation. The findings from the study indicate that 86.6% of the cases had sufficient information to make a high-confidence determination on potential severity, underscoring the feasibility of applying this general framework. Additionally, cases with a higher pSIF score had, on average, a higher level of institutional response. Implementing a simplified methodology for incident classification that emphasizes incidents that pose high potential severity, regardless of incident type, can help LLNL prioritize resources and tailor responses to such incidents using a graded approach. LLNL has recognized the value of this capability and is integrating the framework into their injury and illness process in the 2024 calendar year.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Experimental study of electromagnetic wave scattering from a gyrotropic gaseous plasma column

We experimentally demonstrate the controlled scattering of incident transverse-electric electromagnetic waves from a gyrotropic magnetized plasma cylindrical discharge. Scattered electromagnetic waves can bend left and right by changing the external magnetic field of a plasma rod. Measured scattered wavefronts are in good agreement with electromagnetic simulations. A gyrotropic response is observed for incident wave frequencies ranging from 3.5 to 5.6 GHz for conditions corresponding to a ratio of cyclotron frequency to plasma frequency, ω ce /ω p ≈ 0.16. In conclusion, the observation of a gyrotropic response from cylindrical plasma discharges paves the way for their use as building blocks for future devices such as magnetized plasma photonic crystals, topological insulators, plasma metamaterials, non-reciprocal waveguide structures, and other devices, which require a tunable gyrotropic response from centimeter to meter-scale materials with application-specific geometry.

42 ENGINEERING↗

Safety of Mobile Hydrogen and Fuel Cell Technology Applications: An Investigation by the Hydrogen Safety Panel

Safe practices in the production, storage, distribution, and use of hydrogen are essential for the widespread acceptance of hydrogen and fuel cell technologies. A significant safety incident could damage public perception of hydrogen and fuel cells. Recent incidents involving multi-cylinder hydrogen transport vehicles in the United States have brought attention to the potential impacts of mobile hydrogen storage and transportation. Road transportation of bulk gaseous hydrogen presents unique hazards that can be very different from those for stationary equipment, and new equipment developers may have less experience and expertise than seasoned gas providers. In response to the aforementioned incidents, and in support of hydrogen and fuel cell activities in California specifically, the Hydrogen Safety Panel (HSP) has investigated the safety of mobile hydrogen and fuel cell applications (mobile auxiliary/emergency fuel cell power units, mobile fuelers, multi-cylinder transport vehicles, unmanned aircraft power supplies, and mobile hydrogen generators). The HSP examined the applications, requirements, and performance of mobile applications that are being used extensively outside of California to understand how safety considerations are applied. This report discusses the results of the HSP’s evaluation of hydrogen and fuel cell mobile applications along with recommendations to address relevant safety issues.

08 HYDROGEN↗

The Effect of Prostate-Specific Antigen (PSA) Test on Radiation Risk Estimate for Prostate Cancer Incidence among Atomic-Bomb Survivors

Following our previous report on the radiation doseresponse for prostate cancer incidence rates in the Life Span Study (LSS) cohort of atomic bomb survivors, we reevaluated the radiation-related risk adjusting for differences in baseline cancer incidence rates among three subsets of the LSS cohort defined by the timing of their first participation in biennial health examinations offered to the Adult Health Study (AHS) sub-cohort members and prostate-specificantigen (PSA) testing status for AHS participants: 1. nonAHS participants, 2. AHS participants before receiving PSA test, and 3. AHS participants after receiving PSA test. We found a 2.9-fold increase in the baseline incidence rates among AHS participants after receiving PSA test. After adjusting for the PSA-testing-status effects on the baseline rates the estimated excess relative risk (ERR) per Gy was 0.54 (95% CI: 0.15, 1.05), which was almost identical to the previously reported unadjusted ERR estimate (0.57, 95% CI: 0.21, 1.00). The current results confirmed that, while the PSA testing among AHS participants increased the baseline incidence rates, it did not impact the radiation risk estimate, strengthening the previously reported dose-response relationship for prostate cancer incidence in the LSS. As the use of PSA tests continue in screening and medical settings, analyses of possible effects of PSA testing should be an important aspect of future epidemiological studies of the association between radiation exposure and prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optomechanical Tuning of Second Harmonic Generation Anisotropy in Janus MoSSe/MoS 2 Heterostructures

Symmetry breaking in van der Waals materials enables the realization of quantum states and advanced device functionalities. Janus transition-metal dichalcogenides (TMDs) exhibit distinctive nonlinear optical properties due to their broken out-of-plane mirror symmetry. However, the dynamic control of second harmonic generation (SHG) anisotropy and resonance behavior via optical excitation remains elusive. Here, in this work, we investigate the SHG response of Janus MoSSe/MoS 2 heterostructures with 2H and 3R stackings. We can tune the SHG response by varying the incident photon wavelength from 800 to 1000 nm, which shows a resonance-dependent enhancement in intensity and a deviation from 6-fold symmetry, indicating wavelength-dependent anisotropy. The ratio between maximum and minimum intensity in the armchair directions, associated with the SHG anisotropy, reaches a value of 1.73 at the excitation wavelength of 1000 nm. Group theory analysis and first-principles calculations reveal that the observed anisotropy arises from optically induced strain. Our findings highlight the role of symmetry breaking and optical resonance contributing to the optomechanical tuning of SHG anisotropy, offering opportunities for developing Janus TMD-based photonic devices for frequency conversion, light generation, and optical switching.

Janus transition metal dichalcogenides↗

Measurements of Neutron Scattering from a Copper Sample Using a Quasi-Differential Method in the Region from 2 keV to 20 MeV

Neutron scattering from a copper sample was measured at Rensselaer Polytechnic Institute utilizing the quasi-differential method. The measurement spanned the energy range from 0.5 to 20 MeV using the high-energy scattering system and from 2 keV to 0.5 MeV using the new mid-energy scattering system. Copper was selected as a material of interest to measure due to large discrepancies between experiments and simulations of the Zeus benchmark. The Zeus benchmark consists of a copper reflected highly enriched uranium system, and the angular distribution of copper scattering was thought to potentially be the cause of the discrepancy. The copper measurements found differences in the scattering response particularly in the incident energy region from 1 to 2 MeV for the high-energy measurement and from 2 to 4 keV in the mid-energy system. These differences are particularly noticeable at angles near 90 deg in the high-energy system and back angles in the mid-energy system. Additionally, for ENDF/B-VIII.0 there is a large discrepancy at the forward angle in the energy range around 0.5 MeV. For these reasons, a new evaluation of copper scattering utilizing these results is recommended and perhaps could help to improve the agreement with the Zeus benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature and dopant concentration effects on proton light quenching in rare-earth inorganic scintillators [Slides]

Rare-earth inorganic scintillators have characteristics that offer optimal detection qualities for space applications as long a quenching is considered; Incident proton and electron response was measured in four different rare-earth inorganic scintillators of interest; We observed: A temperature effect on quenching for GAGG type detectors. A dopant concentration/decay time effect on quenching for GAGG detectors; Extracting the Birks’ factor for future detectors will improve the analysis of data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical calibration of the SuperCam instrument body unit spectrometers

The SuperCam remote sensing instrument on NASA’s Perseverance rover is capable of four spectroscopic techniques, remote micro-imaging, and audio recording. These analytical techniques provide details of the chemistry and mineralogy of the rocks and soils probed in the Jezero Crater on Mars. Here we present the methods used for optical calibration of the three spectrometers covering the 243–853 nm range used by three of the four spectroscopic techniques. We derive the instrument optical response, which characterizes the instrument sensitivity to incident radiation as a function of a wavelength. The instrument optical response function derived here is an essential step in the interpretation of the spectra returned by SuperCam as it converts the observed spectra, reported by the instrument as “digital counts” from an analog to digital converter, into physical values of spectral radiance.

Legett, Carey (ORCID:0000000247412841)↗

Modeling and simulation of earthquake soil structure interaction excited by inclined seismic waves

Presented is an application of wave potential formulation (WPF) together with domain reduction method (DRM) to modeling earthquake soil structure interaction (ESSI) behavior in horizontally layered ground under inclined incident seismic waves. Wave potential formulation is used to develop a spatially varying, inclined seismic wave field from incident Primary (P) and Secondary (S) waves that propagate through layered ground. Developed seismic wave field is then used to develop effective forces for Domain Reduction Method that are then used for analyzing ESSI response of a soil structure system. Developed methodology, called WPF-DRM, is verified using analytic solution for a free field response of layered ground subjected to inclined incident waves. Developed WPF-DRM methodology is illustrated through analysis of an ESSI response of a deeply embedded structure, a small modular reactor (SMR) subjected to incident S wave polarized in vertical plane (SV) with variation in inclinations and frequencies. Presented example highlights the influences of incident wave inclination and frequency on ESSI response of analyzed SMR.

58 GEOSCIENCES↗

Physics‐Informed Machine Learning for Inverse Design of Optical Metamaterials

Optical metamaterials manipulate light through various confinement and scattering processes, offering unique advantages like high performance, small form factor and easy integration with semiconductor devices. However, designing metasurfaces with suitable optical responses for complex metamaterial systems remains challenging due to the exponentially growing computation cost and the ill‐posed nature of inverse problems. To expedite the computation for the inverse design of metasurfaces, a physics‐informed deep learning (DL) framework is used. A tandem DL architecture with physics‐based learning is used to select designs that are scientifically consistent, have low error in design prediction, and accurate reconstruction of optical responses. The authors focus on the inverse design of a representative plasmonic device and consider the prediction of design for the optical response of a single wavelength incident or a spectrum of wavelength in the visible light range. The physics‐based constraint is derived from solving the electromagnetic wave equations for a simplified homogenized model. The model converges with an accuracy up to 97% for inverse design prediction with the optical response for the visible light spectrum as input, and up to 96% for optical response of single wavelength of light as input, with optical response reconstruction accuracy of 99%.

Sarkar, Sulagna↗

Explorative Visualization for Traffic Safety using Adaptive Study Areas

The pressing need to improve traffic safety has become a societal concern in many cities around the world. Many traffic accidents are not occurring as stand-alone events but as consequences of other road incidents and hazards. To capture the traffic safety indications from a holistic aspect, this paper presents a suite of visualization techniques to explore large traffic safety datasets collected from different sources using adaptive study areas which include the whole region (Hamilton County, Ohio, U.S.) as well as smaller sub-areas. In the present study, these data source include (1) Hamilton County’s 911 emergency response data, which includes traffic incidents as well as other types of incidents throughout the county, and (2) Tennessee crash data, which contains only vehicle crashes with more detail on the circumstances of each crash. We find that both abstract and spatial visualization techniques are used to derive a better understanding of traffic safety patterns for different traffic participants in various urban environments. In addition to the entire region of Hamilton County, safety is examined on the highways, in the downtown area, and in a shopping district east of the city center. It is possible to characterize incidents in the different areas, gain a better understanding of common incident patterns, and identify outliers in the data. Finally, a textured tile calendar is presented to compare spatiotemporal patterns.

99 GENERAL AND MISCELLANEOUS↗