Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Simulation and studies of spaceborne synthetic aperture radar image quality with reduced bit rate

A computer simulation program that is used to study the effects of digitization in spaceborne synthetic aperture radar systems is described. An analytical study of the distortion noise introduced by the digitization process at various gain settings, sampling rates and bit error rates is presented and the results agree well with those obtained from the simulation program. The simulation program is also used to study the spatial frequency response of hard-limiting (quantizing to 1-bit) synthetic aperture radar systems. The implications of these results on synthetic aperture radar system design are discussed.

Li, F.↗

Effects of a despaced secondary of a Wolter type II telescope on image quality

The focal shift of the Wolter type II telescope, a glancing incidence analog of the normal incidence Cassegrain telescope, due to the despacing of the secondary with respect to the primary, is analyzed. The location of the rms best focus on the optical axis can be derived from a resulting expression. The results are verified by ray tracing of an actual Wolter type II telescope.

Saha, T. T.↗

A hybrid LBG/lattice vector quantizer for high quality image coding

It is well known that a vector quantizer is an efficient coder offering a good trade-off between quantization distortion and bit rate. The performance of a vector quantizer asymptotically approaches the optimum bound with increasing dimensionality. A vector quantized image suffers from the following types of degradations: (1) edge regions in the coded image contain staircase effects, (2) quasi-constant or slowly varying regions suffer from contouring effects, and (3) textured regions lose details and suffer from granular noise. All three of these degradations are due to the finite size of the code book, the distortion measures used in the design, and due to the finite training procedure involved in the construction of the code book. In this paper, we present an adaptive technique which attempts to ameliorate the edge distortion and contouring effects.

Ramamoorthy, V.↗

Software to model AXAF image quality

This draft final report describes the work performed under this delivery order from May 1992 through June 1993. The purpose of this contract was to enhance and develop an integrated optical performance modeling software for complex x-ray optical systems such as AXAF. The GRAZTRACE program developed by the MSFC Optical Systems Branch for modeling VETA-I was used as the starting baseline program. The original program was a large single file program and, therefore, could not be modified very efficiently. The original source code has been reorganized, and a 'Make Utility' has been written to update the original program. The new version of the source code consists of 36 small source files to make it easier for the code developer to manage and modify the program. A user library has also been built and a 'Makelib' utility has been furnished to update the library. With the user library, the users can easily access the GRAZTRACE source files and build a custom library. A user manual for the new version of GRAZTRACE has been compiled. The plotting capability for the 3-D point spread functions and contour plots has been provided in the GRAZTRACE using the graphics package DISPLAY. The Graphics emulator over the network has been set up for programming the graphics routine. The point spread function and the contour plot routines have also been modified to display the plot centroid, and to allow the user to specify the plot range, and the viewing angle options. A Command Mode version of GRAZTRACE has also been developed. More than 60 commands have been implemented in a Code-V like format. The functions covered in this version include data manipulation, performance evaluation, and inquiry and setting of internal parameters. The user manual for these commands has been formatted as in Code-V, showing the command syntax, synopsis, and options. An interactive on-line help system for the command mode has also been accomplished to allow the user to find valid commands, command syntax, and command function. A translation program has been written to convert FEA output from structural analysis to GRAZTRACE surface deformation file (.dfm file). The program can accept standard output files and list files from COSMOS/M and NASTRAN finite analysis programs. Some interactive options are also provided, such as Cartesian or cylindrical coordinate transformation, coordinate shift and scale, and axial length change. A computerized database for technical documents relating to the AXAF project has been established. Over 5000 technical documents have been entered into the master database. A user can now rapidly retrieve the desired documents relating to the AXAF project. The summary of the work performed under this contract is shown.

Ahmad, Anees↗

Development of Software to Model AXAF-I Image Quality

This report describes work conducted on Delivery Order 181 between October 1996 through June 1997. During this period software was written to: compute axial PSD's from RDOS AXAF-I mirror surface maps; plot axial surface errors and compute PSD's from HDOS "Big 8" axial scans; plot PSD's from FITS format PSD files; plot band-limited RMS vs axial and azimuthal position for multiple PSD files; combine and organize PSD's from multiple mirror surface measurements formatted as input to GRAZTRACE; modify GRAZTRACE to read FITS formatted PSD files; evaluate AXAF-I test results; improve and expand the capabilities of the GT x-ray mirror analysis package. During this period work began on a more user-friendly manual for the GT program, and improvements were made to the on-line help manual.

Geary, Joseph↗

Processing Near-Infrared Imagery of the Orion Heatshield During EFT-1 Hypersonic Reentry

The Scientifically Calibrated In-Flight Imagery (SCIFLI) team captured high-resolution, calibrated, near-infrared imagery of the Orion capsule during atmospheric reentry of the EFT-1 mission. A US Navy NP-3D aircraft equipped with a multi-band optical sensor package, referred to as Cast Glance, acquired imagery of the Orion capsule's heatshield during a period when Orion was slowing from approximately Mach 10 to Mach 7. The line-of-sight distance ranged from approximately 65 to 40 nmi. Global surface temperatures of the capsule's thermal heatshield derived from the near-infrared intensity measurements complemented the in-depth (embedded) thermocouple measurements. Moreover, these derived surface temperatures are essential to the assessment of the thermocouples' reliance on inverse heat transfer methods and material response codes to infer the surface temperature from the in-depth measurements. The paper describes the image processing challenges associated with a manually-tracked, high-angular rate air-to-air observation. Issues included management of significant frame-to-frame motions due to both tracking jerk and jitter as well as distortions due to atmospheric effects. Corrections for changing sky backgrounds (including some cirrus clouds), atmospheric attenuation, and target orientations and ranges also had to be made. The image processing goal is to reduce the detrimental effects due to motion (both sensor and capsule), vibration (jitter), and atmospherics for image quality improvement, without compromising the quantitative integrity of the data, especially local intensity (temperature) variations. The paper will detail the approach of selecting and utilizing only the highest quality images, registering several co-temporal image frames to a single image frame to the extent frame-to-frame distortions would allow, and then co-adding the registered frames to improve image quality and reduce noise. Using preflight calibration data, the registered and averaged infrared intensity images were converted to surface temperatures on the Orion capsule's heatshield. Temperature uncertainties will be discussed relative to uncertainties of surface emissivity and atmospheric transmission loss. Comparison of limited onboard surface thermocouple data to the image derived surface temperature will be presented.

Spisz, Thomas S.↗

Leveraging Afterglow in Scintillation-based x-ray detectors for spacetime-resolved computed tomography for accelerated acquisition and high-speed event capture

Afterglow in x-ray imaging for high-speed radiography is a constraint that limits imaging systems to low-light/fast decay screens which create poor data. Current approaches focus purely on using low-light yield screens with fast decay to avoid multiple exposure pileup due to afterglow. The goal of this work is to develop a statistical estimation approach to leverage afterglow to improve image quality thus allowing for higher quality imaging components to be used. This will allow for bright screens will slow decay to be used, and then a post-processing step applies the statistical estimation to separate each frame with superior signal compared to low-light/fast decay screens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cartographic quality of ERTS-1 images

Analyses of simulated and operational ERTS images have provided initial estimates of resolution, ground resolution, detectability thresholds and other measures of image quality of interest to earth scientists and cartographers. Based on these values, including an approximate ground resolution of 250 meters for both RBV and MSS systems, the ERTS-1 images appear suited to the production and/or revision of planimetric and photo maps of 1:500,000 scale and smaller for which map accuracy standards are compatible with the imaged detail. Thematic mapping, although less constrained by map accuracy standards, will be influenced by measurement thresholds and errors which have yet to be accurately determined for ERTS images. This study also indicates the desirability of establishing a quantitative relationship between image quality values and map products which will permit both engineers and cartographers/earth scientists to contribute to the design requirements of future satellite imaging systems.

Welch, R. I.↗

How Many Bits Are Enough?

Carlson and Cohen suggest that 'the perfect image is one that looks like a piece of the world viewed through a picture frame.' They propose that the metric for the perfect image be the discriminability of the reconstructed image from the ideal image the reconstruction is meant to represent. If these two images, the ideal and the reconstruction are noticeably different, then the reconstruction is less than perfect. If they cannot be discriminated then the reconstructed image is perfect. This definition has the advantage that it can be used to define 'good enough' image quality. An image that fully satisfies a task's image quality requirements for example text legibility, is selected to be the standard. Rendered images are then compared to the standard. Rendered images that are indiscriminable from the standard are good enough. Test patterns and test image sets serve as standards for many tasks and are commonplace to the image communications and display industries, so this is not a new nor novel idea.

Larimer, James↗

Image gathering and coding for digital restoration: Information efficiency and visual quality

Image gathering and coding are commonly treated as tasks separate from each other and from the digital processing used to restore and enhance the images. The goal is to develop a method that allows us to assess quantitatively the combined performance of image gathering and coding for the digital restoration of images with high visual quality. Digital restoration is often interactive because visual quality depends on perceptual rather than mathematical considerations, and these considerations vary with the target, the application, and the observer. The approach is based on the theoretical treatment of image gathering as a communication channel (J. Opt. Soc. Am. A2, 1644(1985);5,285(1988). Initial results suggest that the practical upper limit of the information contained in the acquired image data range typically from approximately 2 to 4 binary information units (bifs) per sample, depending on the design of the image-gathering system. The associated information efficiency of the transmitted data (i.e., the ratio of information over data) ranges typically from approximately 0.3 to 0.5 bif per bit without coding to approximately 0.5 to 0.9 bif per bit with lossless predictive compression and Huffman coding. The visual quality that can be attained with interactive image restoration improves perceptibly as the available information increases to approximately 3 bifs per sample. However, the perceptual improvements that can be attained with further increases in information are very subtle and depend on the target and the desired enhancement.

Huck, Friedrich O.↗

Smart Ultrasound Remote Guidance Experiment (SURGE)- Concept of Operations Evaluation for Using Remote Guidance Ultrasound for Planetary Space Flight

Introduction Use of remote guidance (RG) techniques aboard the International Space Station (ISS) has enabled astronauts to collect diagnostic-level ultrasound images. Exploration class missions will require this cohort of (typically) non-formally trained sonographers to operate with greater autonomy given the longer communication delays (2 seconds for ISS vs. >6 seconds for missions beyond the Moon) and communication blackouts. To determine the feasibility and training requirements for autonomous ultrasound image collection by non-expert ultrasound operators, ultrasound images were collected from a similar cohort using three different image collection protocols: RG only, RG with a computer-based learning tool (LT), and autonomous image collection with LT. The groups were assessed for both image quality and time to collect the images. Methods Subjects were randomized into three groups: RG only, RG with LT, and autonomous with LT. Each subject received 10 minutes of standardized training before the experiment. The subjects were tasked with making the following ultrasound assessments: 1) bone fracture and 2) focused assessment with sonography in trauma (FAST) to assess a patient s abdomen. Human factors-related questionnaire data were collected immediately after the assessments. Results The autonomous group did not out-perform the two groups that received RG. The mean time for the autonomous group to collect images was less than the RG groups, however the mean image quality for the autonomous group was less compared to both RG groups. Discussion Remote guidance continues to produce higher quality ultrasound images than autonomous ultrasound operation. This is likely due to near-instant feedback on image quality from the remote guider. Expansion in communication time delays, however, diminishes the capability to provide this feedback, thus requiring more autonomous ultrasound operation. The LT has the potential to be an excellent training and coaching component for autonomous ultrasound image collection during exploration missions.

Hurst, Victor, IV↗

Dynamic Differential Image Circle Diameter Measurement Precision Assessment: Application to Burning Droplets

Dynamic measurement precision assessment has been achieved for a differential circle measurement application. Differential circle diameter measurement, in image analysis, typically requires fitting a circle model that optimizes for image distortions, defects or occlusions. The differential task occurs when precise measurements of diameter change are required given object size variation with time. An automated system was designed to provide diameter measurements and associated measurement precision of images of a fuel droplet undergoing combustion in zero gravity for the FLEX-2 dataset. An image gradient-based, least-squares boundary point fitting method to a circle or ellipse model is used for diameter measurement. The presence of soot aggregates poses significant challenges for diameter measurements when it occludes part of the droplet boundary. The precision of the diameter measurements depends upon the image quality. Using synthetic image simulations that model the soot behavior, we developed a model based on image quality measures that assesses the measurement precision for each individual diameter measurement. Thus, diameter measurements with precision assessments were made available for follow-up scientific analysis. As a result, the algorithm's success rate for measurable runs was 98%. In cases of limited occlusion, a measurement precision of ±0.2 pixels for the FLEX-2 dataset was achieved.

42 ENGINEERING↗

Breadboard linear array scan imager using LSI solid-state technology

The performance of large scale integration photodiode arrays in a linear array scan (pushbroom) breadboard was evaluated for application to multispectral remote sensing of the earth's resources. The technical approach, implementation, and test results of the program are described. Several self scanned linear array visible photodetector focal plane arrays were fabricated and evaluated in an optical bench configuration. A 1728-detector array operating in four bands (0.5 - 1.1 micrometer) was evaluated for noise, spectral response, dynamic range, crosstalk, MTF, noise equivalent irradiance, linearity, and image quality. Other results include image artifact data, temporal characteristics, radiometric accuracy, calibration experience, chip alignment, and array fabrication experience. Special studies and experimentation were included in long array fabrication and real-time image processing for low-cost ground stations, including the use of computer image processing. High quality images were produced and all objectives of the program were attained.

Tracy, R. A.↗

Sparse measurement medical CT reconstruction using multi-fused block matching denoising priors

A major challenge for medical X-ray CT imaging is reducing the number of X-ray projections to lower radiation dosage and reduce scan times without compromising image quality. However these under-determined inverse imaging problems rely on the formulation of an expressive prior model to constrain the solution space while remaining computationally tractable. Traditional analytical reconstruction methods like Filtered Back Projection (FBP) often fail with sparse measurements, producing artifacts due to their reliance on the Shannon-Nyquist Sampling Theorem. Consensus Equilibrium, which is a generalization of Plug and Play, is a recent advancement in Model-Based Iterative Reconstruction (MBIR), has facilitated the use of multiple denoisers are prior models in an optimization free framework to capture complex, non-linear prior information. However, 3D prior modelling in a Plug and Play approach for volumetric image reconstruction requires long processing time due to high computing requirement. Instead of directly using a 3D prior, this work proposes a BM3D Multi Slice Fusion (BM3D-MSF) prior that uses multiple 2D image denoisers fused to act as a fully 3D prior model in Plug and Play reconstruction approach. Our approach does not require training and are thus able to circumvent ethical issues related with patient training data and are readily deployable in varying noise and measurement sparsity levels. In addition, reconstruction with the BM3D-MSF prior achieves similar reconstruction image quality as fully 3D image priors, but with significantly reduced computational complexity. We test our method on clinical CT data and demonstrate that our approach improves reconstructed image quality.

Hossain, Maliha [ORNL]↗

Landsat image data quality studies

Preliminary results of the Landsat-4 Image Data Quality Analysis (LIDQA) program to characterize the data obtained using the Thematic Mapper (TM) instrument on board the Landsat-4 and Landsat-5 satellites are reported. TM design specifications were compared to the obtained data with respect to four criteria, including spatial resolution; geometric fidelity; information content; and image relativity to Multispectral Scanner (MSS) data. The overall performance of the TM was rated excellent despite minor instabilities and radiometric anomalies in the data. Spatial performance of the TM exceeded design specifications in terms of both image sharpness and geometric accuracy, and the image utility of the TM data was at least twice as high as MSS data. The separability of alfalfa and sugar beet fields in a TM image is demonstrated.

Schueler, C. F.↗