Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Icing Wind Tunnel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effect of Intercycle Ice Accretions on Airfoil Performance

This paper presents the results of an experimental study designed to characterize and evaluate the aerodynamic performance penalties of residual and intercycle ice accretions that result from the cyclic operation of a typical aircraft deicing system. Icing wind tunnel tests were carried out on a 36-inch chord NACA 23012 airfoil section equipped with a pneumatic deicer for several different FAR 25 Appendix C cloud conditions. Results from the icing tests showed that the intercycle ice accretions were much more severe in terms of size and shape than the residual ice accretions. Molds of selected intercycle ice shapes were made and converted to castings that were attached to the leading edge of a 36-inch chord NACA 23012 airfoil model for aerodynamic testing. The aerodynamic testing revealed that the intercycle ice shapes caused a significant performance degradation. Maximum lift coefficients were typically reduced about 60% from 1.8 (clean) to 0.7 (iced) and stall angles were reduced from 17 deg. (clean) to 9 deg. (iced). Changes in the Reynolds number (from 2.0 x 10(exp 6) to 10.5 x 10(exp 6) and Mach number (from 0.10 to 0.28) did not significantly affect the iced-airfoil performance.

Broeren, Andy P.↗

Altitude Scaling of Thermal Ice Protection Systems in Running Wet Operation

A study into the effects of altitude on an aircraft thermal Ice Protection System (IPS) performance has been conducted by the National Research Council Canada (NRC) in collaboration with the NASA Glenn Icing Branch. The study included tests of an airfoil model, with a heated-air IPS, installed in the NRCs Altitude Icing Wind Tunnel (AIWT) at altitude and ground level conditions.

Running wet mode↗

In-Flight Aerodynamic Measurements of an Iced Horizontal Tailplane

The effects of tailplane icing on aircraft dynamics and tailplane aerodynamics were investigated using, NASA's modified DHC-6 Twin Otter icing research aircraft. This flight program was a major element of the four-year NASA/FAA research program that also included icing wind tunnel testing, dry-air aerodynamic wind tunnel testing, and analytical code development. Flight tests were conducted to obtain aircraft dynamics and tailplane aerodynamics of the DHC-6 with four tailplane leading-edge configurations. These configurations included a clean (baseline) and three different artificial ice shapes. Quasi-steady and various dynamic flight maneuvers were performed over the full range of angles of attack and wing flap settings with each iced tailplane configuration. This paper presents results from the quasi-steady state flight conditions and describes the range of flow fields at the horizontal tailplane, the aeroperformance effect of various ice shapes on tailplane lift and elevator hinge moment, and suggests three paths that can lead toward ice-contaminated tailplane stall. It was found that wing, flap deflection was the most significant factor in driving the tailplane angle of attack toward alpha(tail stall). However, within a given flap setting, an increase in airspeed also drove the tailplane angle of attack toward alpha(tail stall). Moreover, increasing engine thrust setting also pushed the tailplane to critical performance limits, which resulted in premature tailplane stall.

Ratvasky, Thomas P.↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15µm to 460 µm. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

Icing cloud instruments↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15um to 460 um. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

o Aircraft Icing↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15m to 460 m. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

o Aircraft Icing↗

Proposed modifications to ice accretion/icing scaling theory

The difficulty of conducting full-scale icing tests has long been appreciated. Testing in an icing wind tunnel has been undertaken for decades. While aircraft size and speeds have increased, tunnel facilities have not, thus making subscale geometric tests a necessity. Scaling laws governing these tests are almost exclusively based on analysis performed over 30 years ago and have not been rigorously validated. The following work reviews past scaling analyses and suggests revision to these analyses based on recent experimental observation. It is also suggested, based on the analysis contained herein, that current ice accretion predictive technologies, such as LEWICE when utilized in the glaze ice accretion regime, may need upgrading to more accurately estimate the rate of ice build-up on aerodynamic surfaces.

Bilanin, Alan J.↗

The Calculated and Measured Performance Characteristics of a Heated-Wire Liquid-Water-Content Meter for Measuring Icing Severity

Ground tests have been made of an instrument which, when assembled in a more compact form for flight installation, could be used to obtain statistical flight data on the liquid-water content of icing clouds and to provide an indication of icing severity. The sensing element of the instrument consists of an electrically heated wire which is mounted in the air stream. The degree of cooling of the wire resulting from evaporation of the impinging water droplets is a measure. of the liquid-water content of the cloud. Determination of the value of the liquid-water content from the wire temperature at any instant requires a knowledge of the airspeed, altitude, and air temperature. An analysis was made of the temperature response of a heated wire exposed to an air stream containing water drops. Comparisons were made of the liquid-water content as measured with several heated wires and absorbent cylinders in an artificially produced cloud. For one of the wires, comparative tests were made with a rotating-disk icing-rate meter in an icing wind tunnel. From the test results, it was shown that an instrument for measuring the concentration of liquid water in an air stream can be built using an electrically heated wire of known temperatureresistance characteristics, and that the performance of such a device can be predicted using appropriate theory. Although an instrument in a form suitable for gathering statistical data in flight was not built, the practicability of constructing such an instrument was illustrated. The ground-test results indicated that a flight heated-wire instrument would be simple and durable, would respond rapidly to variations in liquid-water content, and could be used for the measurement of water content in clouds which are above freezing temperature, as well as in icing clouds.

Neel, Carr B.↗

A combined analytical-experimental tensile test technique for brittle materials

A semiconventional tensile test technique is developed for impact ices and other brittle materials. Accurate results have been obtained on ultimate strength and modulus of elasticity in a refrigerated ice test. It is noted that the technique can be used to determine the physical properties of impact ices accreted inside icing wind tunnels or other brittle materials.

Chu, M. L.↗

Implementation of Combined Feather and Surface-Normal Ice Growth Models in LEWICE/X

Experimental observations have shown that discrete rime ice growths called feathers, which grow in approximately the direction of water droplet impingement, play an important role in the growth of ice on accreting surfaces for some thermodynamic conditions. An improved physical model of ice accretion has been implemented in the LEWICE 2D panel-based ice accretion code maintained by the NASA Lewis Research Center. The LEWICE/X model of ice accretion explicitly simulates regions of feather growth within the framework of the LEWICE model. Water droplets impinging on an accreting surface are withheld from the normal LEWICE mass/energy balance and handled in a separate routine; ice growth resulting from these droplets is performed with enhanced convective heat transfer approximately along droplet impingement directions. An independent underlying ice shape is grown along surface normals using the unmodified LEWICE method. The resulting dual-surface ice shape models roughness-induced feather growth observed in icing wind tunnel tests. Experiments indicate that the exact direction of feather growth is dependent on external conditions. Data is presented to support a linear variation of growth direction with temperature and cloud water content. Test runs of LEWICE/X indicate that the sizes of surface regions containing feathers are influenced by initial roughness element height. This suggests that a previous argument that feather region size is determined by boundary layer transition may be incorrect. Simulation results for two typical test cases give improved shape agreement over unmodified LEWICE.

Matthew T Velazquez↗

NASA/FAA Tailplane Icing Program Overview

The effects of tailplane icing were investigated in a four-year NASA/FAA Tailplane Icing, Program (TIP). This research program was developed to improve the understanding, of iced tailplane aeroperformance and aircraft aerodynamics, and to develop design and training aides to help reduce the number of incidents and accidents caused by tailplane icing. To do this, the TIP was constructed with elements that included icing, wind tunnel testing, dry-air aerodynamic wind tunnel testing, flight tests, and analytical code development. This paper provides an overview of the entire program demonstrating the interconnectivity of the program elements and reports on current accomplishments.

Ratvasky, Thomas P.↗

Numerical Analysis of Mixed-Phase Icing Cloud Simulations in the NASA Propulsion Systems Laboratory

This presentation describes the development of a numerical model that couples the thermal interaction between ice particles, water droplets, and the flowing gas of an icing wind tunnel for simulation of NASA Glenn Research Centers Propulsion Systems Laboratory (PSL). The ultimate goal of the model is to better understand the complex interactions between the test parameters and have greater confidence in the conditions at the test section of the PSL tunnel. The model attempts to explain the observed changes in test conditions by coupling the conservation of mass and energy equations for both the cloud particles and flowing gas mass. Model predictions were compared to measurements taken during May 2015 testing at PSL, where test conditions varied gas temperature, pressure, velocity and humidity levels, as well as the cloud total water content, particle initial temperature, and particle size distribution.

NASA PSL↗

Numerical Analysis of Mixed-Phase Icing Cloud Simulations in the NASA Propulsion Systems Laboratory

This paper describes the development of a numerical model that couples the thermal interaction between ice particles, water droplets, and the flowing gas of an icing wind tunnel for simulation of NASA Glenn Research Centers Propulsion Systems Laboratory (PSL). The ultimate goal of the model is to better understand the complex interactions between the test parameters and have greater confidence in the conditions at the test section of the PSL tunnel. The model attempts to explain the observed changes in test conditions by coupling the conservation of mass and energy equations for both the cloud particles and flowing gas mass. Model predictions were compared to measurements taken during May 2015 testing at PSL, where test conditions varied gas temperature, pressure, velocity and humidity levels, as well as the cloud total water content, particle initial temperature, and particle size distribution.

NASA PSL↗

Cloud Uniformity Measurement from NASA's 2nd Fundamental Ice Crystal Icing Test Part 1 (Water Content & PSD)

This paper presents water content and particle measurements from the second Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The water content measurements came from the Science Engineering Associates Multi-Element Probe and the Isokinetic Probe whereas the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments measured the particle size distribution. Ice particle accretion due to the ingestion of ice-crystals is attributed to numerous jet engine powerloss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. This work focuses on characterizing the icing cloud by traversing the instruments across the test section at four different conditions where velocity and water content were varied. For this test, the nozzle patterns were selected to make a uniform cloud in the center 6-inch diameter of the test section. Radial trends for the ice and water content measurements are presented and the melt ratio is calculated at the measurement locations. Particle size distributions are also presented. The measured water content, melt ratio, and particle size decreased moving out radially. Measured water content trends show uniformity to within 19.2% for the center 6 inches of the cloud, as intended. In addition, the total water content increased at centerline with velocity, whereas the melt ratio decreased.

Ice-Crystal Icing↗

Cloud Uniformity Measurements from NASA's 2nd Fundamental Ice Crystal Icing Test Part 1 (Water Content & PSD)

This paper presents water content and particle measurements from the second Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The water content measurements came from the Science Engineering Associates Multi-Element Probe and the Isokinetic Probe whereas the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments measured the particle size distribution. Ice particle accretion due to the ingestion of ice-crystals is attributed to numerous jet engine powerloss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. This work focuses on characterizing the icing cloud by traversing the instruments across the test section at four different conditions where velocity and water content were varied. For this test, the nozzle patterns were selected to make a uniform cloud in the center 6-inch diameter of the test section. Radial trends for the ice and water content measurements are presented and the melt ratio is calculated at the measurement locations. Particle size distributions are also presented. The measured water content, melt ratio, and particle size decreased moving out radially. Measured water content trends show uniformity to within 19.2% for the center 6 inches of the cloud, as intended. In addition, the total water content increased at centerline with velocity, whereas the melt ratio decreased.

Ice-Crystal Icing↗

New Spray Bar System Installed in NASA Lewis' Icing Research Tunnel

NASA Lewis Research Center's Icing Research Tunnel (IRT) is the world's largest refrigerated wind tunnel dedicated to the study of aircraft icing. In the IRT, natural icing conditions are duplicated to test the effects of in-flight icing on actual aircraft components and on scale models of airplanes and helicopters. The IRT's ability to reproduce a natural icing cloud was significantly improved with the recent installation of a new spray bar system. It is the spray bar system that transforms the low-speed wind tunnel into an icing wind tunnel by producing microscopic droplets of water and injecting them into the wind tunnel air stream in order to accurately simulate cloud moisture.

Irvine, Thomas B.↗

Experimental measurements of heat transfer from an iced surface during artificial and natural cloud icing conditions

The heat transfer behavior of accreting ice surfaces in natural (flight test) and simulated (wind tunnel) cloud icing conditions were studied. Observations of wet and dry ice growth regimes as measured by ultrasonic pulse echo techniques were made. Observed wet and dry ice growth regimes at the stagnation point of a cylinder were compared with those predicted using a quasi steady state heat balance model. A series of heat transfer coefficients were employed by the model to infer the local heat transfer behavior of the actual ice surfaces. The heat transfer in the stagnation region was generally inferred to be higher in wind tunnel icing tests than in natural flight icing conditions.

Kirby, Mark S.↗

Experimental measurements of heat transfer from an iced surface during artificial and natural cloud icing conditions

The heat transfer behavior of accreting ice surfaces in natural (flight test) and simulated (wind tunnel) cloud icing conditions have been studied. Observations of wet and dry ice growth regimes as measured by ultrasonic pulse-echo techniques were made. Observed wet and dry ice growth regimes at the stagnation point of a cylinder were compared with those predicted using a quasi steady-state heat balance model. A series of heat transfer coefficients were employed by the model to infer the local heat transfer behavior of the actual ice surfaces. The heat transfer in the stagnation region was generally inferred to be higher in wind tunnel icing tests than in natural, flight, icing conditions.

Kirby, M. S.↗