Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SIMS Data Correction Procedure for Quasi‐Simultaneous Arrival ( QSA ) Under‐counting and Ramifications of Misapplication

Isotope geochemistry requires isotope ratios measured using secondary ion mass spectrometry (SIMS) to be made with optimal precision and accuracy. Under some analytical conditions when using electron multiplier detectors, secondary ions may be under‐counted because of quasi‐simultaneous arrival (QSA) at the first dynode. The relative magnitude of the associated QSA correction to raw measured isotopic ratios can be up to seventy permil or more. Therefore, not applying the correction, or misapplication of it could lead to significant inaccuracies in published isotope ratio data. Examples and ramifications of the latter are described in addition to a straightforward procedure for QSA under‐counting correction.

Geochemistry & Geophysics↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

Direct isotopic analysis of solid uranium particulates on cotton swipes by microextraction-ICP-MS

Direct isotope ratio analysis of solid uranium particulates on cotton swipes was achieved using a solution-based microextraction technique, coupled to a quadrupole inductively coupled plasma - mass spectrometer (ICP-MS). This microextraction-ICP-MS methodology provides rapid isotopic analysis which could be applicable to nuclear safeguards measurements. Particulates of uranyl nitrate hexahydrate (UO 2 (NO 3 ) 2 ·6H 2 O) and uranyl fluoride (UO 2 F 2 ) ranging from 6 μm to 40 μm in length were transferred to cotton swipes with a particle manipulator. The microextraction probe then delivers a 5% nitric acid (HNO3) solvent onto the swipe surface to extract the uranium species. The extracted sample is then delivered to the ICP-MS for isotopic determination. The majority of uranium signal (~99% and ~94% for UO2(NO3)2·6H2O and UO 2 F 2 , respectively) was detected in the first 15 s extraction, while subsequent extractions on the same location had low or no U signal, suggesting near complete removal of the solid uranium compounds from the swipe surface. Ten samples (for each of the uranium compounds), were analyzed for their isotopic composition. For UO 2 (NO 3 ) 2 ·6H 2 O, the determined isotope ratios resulted in a % relative difference (% RD) from the referenced isotope ratios of 0.97, 1.0, and 7.3% for 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U, respectively. The % RD of the UO 2 F 2 isotope ratios were 1.9 and 0.60% for 234 U/ 238 U and 235 U/ 238 U, respectively. The preliminary limits of detection were determined to be 0.002, 0.4, and 60 pg for 234 U, 235 U and 238 U, respectively This work demonstrates that microextraction ICP-MS is a rapid and sensitive method that could directly determine uranium isotope ratios of UO 2 (NO 3 ) 2 ·6H 2 O and UO 2 F 2 particulates on cotton swipes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Thermonuclear Reaction Rate Uncertainties on the Identification of Presolar Grains from Classical Novae

Approximately 30%–40% of classical novae generate dust between 20 and 100 days following the eruption. However, there has yet to be a definitive identification of presolar stardust grains originating from classical novae. While multiple studies have suggested a nova origin for specific grains, aligning simultaneously all measured isotopic ratios of a specific grain with those predicted from simulations remains challenging. Using Monte Carlo simulations, this work investigates how uncertainties in thermonuclear reaction rates influence the isotopic ratios predicted in simulations of classical novae, specifically impacting the identification of presolar grains. In particular, we address two questions: (i) What is the impact of uncertainties in reaction rates on the range of isotopic ratios predicted by classical nova simulations? (ii) Which reaction rate uncertainties most significantly influence the predicted abundance ratios in presolar grains? Our results show that current reaction rate uncertainties affect the isotopic ratios of 12 C/ 13 C, 14 N/ 15 N, 16 O/ 17 O, 16 O/ 18 O, 24 Mg/ 25 Mg, 24 Mg/ 26 Mg, 26 Al/ 27 Al, and 28 Si/ 29 Si by less than 20% in either carbon–oxygen or oxygen–neon (ONe) novae, especially when considering the mixing of matter throughout the entire envelope. However, the isotopic ratios of 28 Si/ 30 Si, 32 S/ 33 S, and 32 S/ 34 S in ONe novae are exceptions: their variability greatly exceeds a factor of 2 due to the uncertainties in the reaction rates of 30 P(p,γ) 31 S, 33 S(p,γ) 34 Cl, and 34 S(p,γ) 35 Cl, respectively. These results highlight the significant influence of specific reaction rates on the predicted abundance ratios and underscore the necessity for accurate nuclear measurements to reduce these uncertainties.

Classical novae↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗

Isotope ratio-based quantification of carbon assimilation highlights the role of plastidial isoprenoid precursor availability in photosynthesis

Abstract Background We report a method to estimate carbon assimilation based on isotope ratio-mass spectrometry (IRMS) of 13 CO 2 labeled plant tissue. Photosynthetic carbon assimilation is the principal experimental observable which integrates important aspects of primary plant metabolism. It is traditionally measured through gas exchange. Despite its centrality in plant research, gas exchange performs poorly with rosette growth habits typical of Arabidopsis thaliana , mutant lines with limited biomass, and accounts poorly for leaf shading. Results IRMS-based carbon assimilation values from plants labeled at different light intensities were compared to those obtained by gas exchange, and the two methods yielded similar values. Using this method, we observed a strong correlation between 13 C content and labeling time (R 2 = 0.999) for 158 wild-type plants labeled for 6 to 42 min. Plants cultivated under different light regimes showed a linear response with respect to carbon assimilation, varying from 7.38 nmol 13 C mg −1 leaf tissue min −1 at 80 PAR to 19.27 nmol 13 C mg −1 leaf tissue min −1 at 500 PAR. We applied this method to examine the link between inhibition of the 2 C -methyl- d -erythritol-4-phosphate (MEP) pathway and suppression of photosynthesis. A significant decrease in carbon assimilation was observed when metabolic activity in the MEP pathway was compromised by mutation or herbicides targeting the MEP pathway. Mutants affected in MEP pathway genes 1-DEOXY- d -XYLULOSE 5-PHOSPHATE SYNTHASE (DXS) or 1-HYDROXY-2-METHYL-2-(E)-BUTENYL 4-DIPHOSPHATE SYNTHASE (HDS) showed assimilation rates 36% and 61% lower than wild type. Similarly, wild type plants treated with the MEP pathway inhibitors clomazone or fosmidomycin showed reductions of 52% and 43%, respectively, while inhibition of the analogous mevalonic acid pathway, which supplies the same isoprenoid intermediates in the cytosol, did not, suggesting inhibition of photosynthesis was specific to disruption of the MEP pathway. Conclusions This method provides an alternative to gas exchange that offers several advantages: resilience to differences in leaf overlap, measurements based on tissue mass rather than leaf surface area, and compatibility with mutant Arabidopsis lines which are not amenable to gas exchange measurements due to low biomass and limited leaf surface area. It is suitable for screening large numbers of replicates simultaneously as well as post-hoc analysis of previously labeled plant tissue and is complementary to downstream detection of isotopic label in targeted metabolite pools.

2C‑methyl‑d‑erythritol 4‑phosphate pathway↗

The NEON Daily Isotopic Composition of Environmental Exchanges Dataset

The National Ecological Observatory Network (NEON) provides open-access measurements of stable isotope ratios in atmospheric water vapor (δ 2 H, δ 18 O) and carbon dioxide (δ 13 C) at different tower heights, as well as aggregated biweekly precipitation samples (δ 2 H, δ 18 O) across the United States. These measurements were used to create the NEON Daily Isotopic Composition of Environmental Exchanges (NEON-DICEE) dataset estimating precipitation (P; δ 2 H, δ 18 O), evapotranspiration (ET; δ 2 H, δ 18 O), and net ecosystem exchange (NEE; δ 13 C) isotope ratios. Statistically downscaled precipitation datasets were generated to be consistent with the estimated covariance between isotope ratios and precipitation amounts at daily time scales. Isotope ratios in ET and NEE fluxes were estimated using a mixing-model approach with calibrated NEON tower measurements. NEON-DICEE is publicly available on HydroShare and can be reproduced or modified to fit user specific applications or include additional NEON data records as they become available. The NEON-DICEE dataset can facilitate understanding of terrestrial ecosystem processes through their incorporation into environmental investigations that require daily δ 2 H, δ 18 O, and δ 13 C flux data.

54 ENVIRONMENTAL SCIENCES↗

Analysis of solid uranium particulates on cotton swipes with an automated microextraction-ICP-MS system

Here, an automated microextraction method coupled to an inductively coupled plasma – mass spectrometer (ICP-MS) was developed for the direct analysis of solid uranium particulates on the surface of cotton swipes. The microextraction probe extracts particulates from the sample surface, in a flowing solvent, and directs the removed analyte to an ICP-MS for isotopic determination. The automated system utilizes a mechanical XY stage that is software controlled with the capability of saving and returning to specific locations and a camera focused to the swipe surface for optimal viewing of the extracted locations (i.e., material present). Here, particulates (n = 135) were extracted and measured by ICP-MS, including 35 depleted uranyl nitrate hexahydrate (UN) (used for mass bias corrections), 50 uranyl fluoride (UO 2 F 2 ), and 50 uranyl acetate (UAc) particulates. Blank extractions were performed on the cotton swipes between triplicate sample analyses. Between each swipe extraction, the probe was sent between two wells containing 10% and 5% HNO 3 to clean the probe head and to eliminate any analyte carryover between particulates. The measured 235 U/ 238 U and 234 U/ 238 U isotope ratios for the UO 2 F 2 particulates were 0.00725(8) and 0.000054(4), a percent relative difference (% RD) of –0.041% and –1.7% from the reference isotope ratios determined in-lab through multi-collector ICP-MS analysis of dissolved aliquots of the U material. The UAc samples had a measured 235 U/ 238 U isotope ratio of 0.00206(7), a –0.96% relative difference from the reference value of 0.00208(1). The 234 U/ 238 U and 236 U/ 238 U isotope ratios were 0.000008(1) and 0.000031(4), –5.1% RD and –4.3% RD, respectively. The automated sample stage enabled seamless and rapid particle analysis, leading to a significant increase in throughput versus what was previously possible. Additionally, the saved location capability reduced user sampling error as sampling locations were easily stored and recalled. Analysis of U particles on the swipe surface – including blanks, mass bias, and triplicate extractions – was completed in less than an hour without any sample preparation necessary.

47 OTHER INSTRUMENTATION↗

Rhenium Isotope Reconnaissance of Uranium Ore Concentrates

Exploration of natural isotopic variations of the element rhenium (Re) is in its infancy, with initial studies revealing isotopic fractionation in a variety of geological materials. Here, in this work, we investigate Re isotope variation as a new geochemical tool, given its redox-sensitive properties and affinity for organic matter and sulfides. In this work, Re abundance and isotope ratio data were collected from uranium ore concentrates (UOCs) across a variety of depositional ages, locations, geologic settings, and deposit types. Ore types from which the UOC were derived include sandstone, unconformity, and quartz-pebble (QP) conglomerate. To isolate Re from the U-rich matrix of UOCs, a new purification method utilizing DGA ion exchange resin was developed. We found that UOCs exhibit a wide range of Re isotope ratios, with sandstone ore-derived UOCs having the isotopically lightest values, QP conglomerate ore-derived UOCs having the heaviest, and unconformity ore-derived UOCs in between (with some overlap with sandstone UOCs). The Re isotope ratio range observed in UOCs extends previously reported values by more than a factor of two. Industrial processing (e.g., incomplete recovery of Re from ore, contamination, fractionation during processing) may play a role in the isotopic variability in the UOCs. However, systematic differences between ore types suggest that the depositional setting is a significant factor. For nuclear forensic investigations, Re isotopic compositions combined with data from other isotopic systems provide geochemical signatures that can aid in provenance assessment of UOCs. Regardless of the specific causes for the wide range of Re isotope ratios in UOCs, these initial data indicate Re is a promising tool for nuclear forensic investigations on samples from early in the nuclear fuel cycle.

58 GEOSCIENCES↗

Synthesis and characterization of isotopically barcoded nickel, molybdenum, and tungsten taggants for intentional nuclear forensics

Intentional nuclear forensics is a concept wherein the deliberate addition of benign and persistent material signatures to nuclear material can be used to reduce the time between the discovery of material outside of regulatory control and determination of its original provenance. One concept within intentional nuclear forensics involves the use of perturbed stable isotopes to generate unique isotope ratio “barcodes” to encode information (e.g., production batch, location, etc.) and track material throughout the nuclear fuel cycle. Synthesis of taggant species of nickel (Ni), molybdenum (Mo), and tungsten (W) was undertaken via a double-spike mechanism, wherein two highly enriched isotopes of interest per elemental taggant were mixed to form an enriched “double-spike” which was subsequently isotopically diluted with bulk material having a natural isotopic composition. Two taggant species perturbing isotopic ratios, alpha (α) and beta (β), for each of Ni, Mo, and W were synthesized. Independent measurements of double spikes and alpha and beta taggant species agreed within uncertainty and are clearly resolvable from natural compositions. High-precision analyses were independently performed by MC-ICP-MS at two U.S. National Laboratories, with consensus values and uncertainties calculated for all samples. Observed isotopic perturbations in the final taggant species measured on the order of hundreds to thousands of permille (‰) with respect to natural for isotope ratios of interest (e.g., 60 Ni/ 58 Ni, 100 Mo/ 98 Mo, 186 W/ 183 W). Discrepancies between modeled and measured isotopic compositions were observed and are largely attributed to imprecise vendor assay values for starting materials. Using measured starting material compositions as inputs for the mixing model improved the level of agreement between predicted and measured α and β taggant isotope ratios. Overall, characterization of all taggant species demonstrates that this “barcode” concept could have viability for use in nuclear forensics. Finally, it is expected that for any two-isotope mixing array dozens of isotopic barcodes could be encoded into a material system and subsequently resolved utilizing modern mass spectrometric methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS

The ability to directly measure uranium isotope ratios on environmental swipes has been achieved through a solution-based microextraction process and represents a significant advancement toward the development of a rapid method to analyze international nuclear safeguard samples. Here, a microextraction probe is lowered and sealed onto the swipe surface, and analytes within the sampling site (~8 mm2) are dissolved and extracted into a flowing solvent of 2% nitric acid (HNO 3 ). The mobilized species are subsequently directed into an inductively coupled plasma-mass spectrometer (ICP-MS) for accurate and precise isotope ratio determination. This work highlights the novelty of the sampling mechanism, particularly with the direct coupling of the microextraction probe to the ICP-MS and measurement of uranium isotope ratios. The preliminary method detection limit for the microextraction-ICP-MS method, utilizing a quadrupole-based MS, was determined to be ~50 pg of 238 U. Additionally, precise and accurate isotope ratio measurements were achieved on uranium reference materials for both the major ( 235 U/ 238 U) and minor ( 234 U/ 238 U and 236 U/ 238 U) ratios. While the present work is focused on directly measuring uranium isotopic systems on swipe surfaces for nuclear safeguards and verification applications, the benefits would extend across many applications in which direct solid sampling is sought for elemental and isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heterogeneous isotope effects decouple conifer leaf and branch sugar δ 18 O and δ 13 C

Isotope ratios of tree-ring cellulose are a prominent tool to reconstruct paleoclimate and plant responses to environmental variation. Current models for cellulose isotope ratios assume a transfer of the environmental signals recorded in bulk leaf water to carbohydrates and ultimately into stem cellulose. However, the isotopic signal of carbohydrates exported from leaf to branch may deviate from mean leaf values if spatial heterogeneity in isotope ratios exists in the leaf. We tested whether the isotopic heterogeneity previously observed along the length of a ponderosa pine (Pinus ponderosa) leaf water was preserved in photosynthetic products. We observed an increase in both sugar and bulk tissue δ 18 O values along the needle, but the increase in carbohydrate δ 18 O values was dampened relative to the trend observed in leaf water. In contrast, δ 13 C values of both sugar and bulk organic matter were invariant along the needle. Additionally, phloem-exported sugar measured in the branch below the needles did not match whole-needle values of δ 18 O or δ 13 C. Instead, there was a near-constant offset observed between the branch and needle sugar δ 13 C values, while branch δ 18 O values were most similar to δ 18 O values observed for sugar at the base of the needle. The observed offset between the branch and needle sugar δ 18 O values likely arises from partial isotope oxygen exchange between sugars and water during phloem loading and transport. An improved understanding of the conditions producing differential δ 13 C and δ 18 O isotope effects between branch phloem and needle sugars could improve tree-ring-based climate reconstructions.

59 BASIC BIOLOGICAL SCIENCES↗

Preparation of 241 Am/ 243 Am gravimetric mixtures and development of Am isotopic and assay measurement techniques using thermal ionization mass spectrometry

Three gravimetric mixtures with 241 Am/ 243 Am isotope ratios at nominally 1:1, 20:1, and 200:1 were prepared for calibration of the thermal ionization mass spectrometer instruments used for americium isotopic and assay measurements by isotope dilution mass spectrometry. The total evaporation analytical technique was developed for high-accuracy and precision measurements of Am isotopic ratios. The technique was also applied to Am assay measurements using isotope dilution mass spectrometry. The Am isotope ratio and assay measurement techniques were utilized to characterize batches of americium oxide separated from plutonium materials in storage at Los Alamos National Laboratory in support of commercial use of 241 AmO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling of nitric acid digestion and anion-exchange resin separation for the determination of methylmercury isotopic composition within organisms

Isotope ratios of methylmercury (MeHg) within organisms can be used to identify sources of MeHg that have accumulated in food webs, but these isotopic compositions are masked in organisms at lower trophic levels by the presence of inorganic mercury (iHg). To facilitate measurement of MeHg isotope ratios in organisms, we developed a method of extracting and isolating MeHg from fsh and aquatic invertebrates for compound-specifc isotopic analysis involving nitric acid digestion, batch anion-exchange resin separation, and pre-concentration by purge and trap. Recovery of MeHg was quantifed after each step in the procedure, and the average cumulative recovery of MeHg was 93.4±2.9% (1 SD, n=28) for biological reference materials and natural biota samples and 96.9±1.8% (1 SD, n=5) for aqueous MeHgCl standards. The amount of iHg impurities was also quantifed after each step, and the average MeHg purity was 97.8±4.3% (1 SD, n=28) across all reference materials and natural biota samples after the fnal separation step. Measured MeHg isotopic compositions of reference materials agreed with literature values obtained using other MeHg separation techniques, and MeHg isotope ratios of aqueous standards, reference materials, and natural biota samples were reproducible. On average, the reproducibility associated with reference material process replicates (2 SD) was 0.10‰ for δ 202 MeHg and 0.04‰ for Δ 199 MeHg. This new method provides a streamlined, reliable technique that utilizes a single sample aliquot for MeHg concentration and isotopic analysis. Furthermore, this promotes a tight coupling between MeHg concentration, %MeHg, and Hg isotopic composition, which may be especially benefcial for studying complex food webs with multiple isotopically distinct sources of iHg and/or MeHg.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NEONiso R Package, versions greater than 0.5.2

Carbon fluxes in terrestrial ecosystems and their response to environmental change are a major source of uncertainty in the modern carbon cycle. The National Ecological Observatory Network (NEON) presents the opportunity to merge eddy covariance (EC)-derived fluxes with CO2 isotope ratio measurements to gain insights into carbon cycle processes. Collected continuously and consistently across >40 sites, NEON EC and isotope data facilitate novel integrative analyses. However, currently provisioned atmospheric isotope data are uncalibrated, greatly limiting ability to perform cross-site analyses. Here, we present two approaches to calibrating NEON CO2 isotope ratios, along with an R package to calibrate NEON data. We find that calibrating CO2 isotopologues independently yields a lower d13C bias (<0.05‰) and higher precision (<0.40‰) than directly correcting d13C with linear regression (bias: <0.11‰, precision: 0.42‰), but with slightly higher error and lower precision in calibrated CO2 mole fraction. The magnitude of the corrections to d13C and CO2 mole fractions vary substantially by site, underscoring the need for users to apply a consistent calibration framework to data in the NEON archive. Post-calibration data sets show that site mean annual d13C correlates negatively with precipitation, temperature, and aridity, but positively with elevation. Forested and agricultural ecosystems exhibit larger gradients in CO2 and d13C than other sites, particularly during the summer and at night. The overview and analysis tools developed here will facilitate cross-site analysis using NEON data, provide a model for other continental-scale observational networks, and enable new advances leveraging the isotope ratios of specific carbon fluxes.

Fiorella, Richard↗

SIMS Analysis of d18O and d13C of Carbonate Cements in Shale & Mudstone. Final report

This project has had two primary goals: 1) improving new technology for in situ microanalysis of stable isotope ratios by SIMS (secondary ion mass spectrometry) and 2) evaluating the importance of in situ analysis for studies of carbonate cements within shales of the Bakken Petroleum System. The systematic relations of stable isotope ratios provide an important tool to help resolve critical questions in geology. Stable isotope analysis of carbonate cements in shale constrain many topics of interest to DOE including: CO2 sequestration, climate change, and the genesis and quality of rock reservoirs for petroleum, natural gas, and water. However, this evidence is often preserved as fine-scale zonation, which is homogenized by conventional bulk analysis of powders. Recently, analysis of ultra-small spots in polished samples at the University of Wisconsin WiscSIMS Lab. has documented stable isotope zoning in carbonates and other diagenetic cements at smaller scales than previously possible. We have made detailed studies of oxygen and carbon isotope ratios in diagenetic cements from shales of the Bakken Formation from the Williston basin and elsewhere. The Bakken contains both reservoir and source rocks for petroleum. Hydrofracturing has greatly enhanced production of oil in these tight reservoirs. The sediments contain zoned carbonate cements with growth textures that record multiple events. The growth of carbonate (dolomite) cements has been proposed to control reservoir quality, but previous stable isotope studies of homogenized powders could not resolve individual generations of cement and this proposal remains untested. Our better characterization of the multiple growth zones in these carbonates will aid in understanding the genesis of these tight reservoirs and the production of unconventional oil and gas. This study has also developed SIMS standards for analysis of all compositions of Ca-Mg-Fe carbonate and selected Mn-carbonates and hydromagnesite. We have refined techniques for improved accuracy of SIMS stable isotope analysis, and for sub-1-micron spot sizes. We have established protocols for mapping and correlating sample analyses at micron-scale using QGIS software.

04 OIL SHALES AND TAR SANDS↗

A Systematic Investigation of the Effects of Standard-Sample Concentration Mismatch during Fe Isotope Measurement by MC-ICP-MS

Advances in multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) have led to the widespread use of iron (Fe) isotopes to elucidate the (bio)geochemical history of a range of environments. To generate Fe isotope ratio measurements, standard-sample bracketing (SSB) is commonly used to correct for instrumental mass bias inherent to MC-ICP-MS. However, SSB is only accurate when sample and isotope standard Fe concentrations match, in addition to the bulk solution matrix. When the Fe concentrations differ, Fe isotope ratio measurement results may be inaccurate, a phenomenon known as the "self-induced matrix effect." Here, this study systematically characterised the self-induced matrix effect for dry plasma Fe isotope ratio measurements on three MC-ICP-MS instruments and three introduction systems. Our extensive dataset indicates that: (1) the degree of mass bias is consistent regardless of MC-ICP-MS front-end design, (2) the degree of mass bias becomes less reproducible as the concentration difference between the sample and bracketing standard increases, and (3) this applies to both pure Fe solutions and solutions from geological materials. This study reinforces the requirement to match bracketing standard and sample concentrations within 10% and provides a correction method for that fall beyond the recommended concentration range to subsequently allow for proper concentration matching during SSB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗