Structural Characterization and Gas Reactions of Small Metal Particles by High Resolution In-situ TEM and TED

A commercial electron microscope with flat-plate upper pole piece configuration of the objective lens and top entry specimen introduction was modified to obtain 5 x 10 to the minus 10th power mbar pressure at the site of the specimen while maintaining the convenience of a specimen airlock system that allows operation in the 10 to the 10th power mbar range within 15 minutes after specimen change. The specimen chamber contains three wire evaporation sources, a specimen heater, and facilities for oxygen or hydrogen plasma treatment to clean as-introduced specimens. Evacuation is achieved by dural differential pumping, with fine entrance and exit apertures for the electron beam. With the microscope operating at .000001 mbar, the first differential pumping stage features a high-speed cryopump operating in a stainless steel chamber that can be mildly baked and reaches 1 x 10 to the minus 8th power mbar. The second stage, containing the evaporation sources and a custom ionization gauge within 10 cm from the specimen, is a rigorously uncompromised all-metal uhv-system that is bakable to above 200 C throughout and is pumped with an 80-liter ion pump. Design operating pressures and image quality (resolution of metal particles smaller than 1 nm in size) was achieved.

Heinemann, K.

SPEAR-1: An experiment to measure current collection in the ionosphere by high voltage biased conductors

An experiment is described in which a high electrical potential difference, up to 45 kV, was applied between deployed conducting spheres and a sounding rocket in the ionosphere. Measurements were made of the applied voltage and the resulting currents for each of 24 applications of different high potentials. In addition, diagnostic measurements of optical emissions in the vicinity of the spheres, energetic particle flow to the sounding rocket, dc electric field and wave data were made. The ambient plasma and neutral environments were measured by a Langmuir probe and a cold cathode neutral ionization gauge, respectively. The payload is described and examples of the measured current and voltage characteristics are presented. The characteristics of the measured currents are discussed in terms of the diagnostic measurements and the in-situ measurements of the vehicle environment. In general, it was found that the currents observed were at a level typical of magnetically limited currents from the ionospheric plasma for potentials less than 12 kV, and slightly higher for larger potentials. However, due to the failure to expose the plasma contactor, the vehicle sheath modified the sphere sheaths and made comparisons with the analytic models of Langmuir-Blodgett and Parker-Murphy less meaningful. Examples of localized enhancements of ambient gas density resulting from the operation of the attitude control system thrusters (cold nitrogen) were obtained. Current measurements and optical data indicated localized discharges due to enhanced gas density that reduced the vehicle-ionosphere impedance.

Raitt, W. John

Rocket/Radar Sporadic-E Experiment Conducted during the El Coqui 2 Campaign

In order to investigate the complex electrodynamics and neutral-plasma coupling inherent to sporadic-E layers in the earth's mid-latitude ionosphere, a series of rocket/radar experiments were planned as part of the NASA El Coqui H Campaign from Tortuguero Launch Range, Puerto Rico, in March-April, 1998. The rocket experiments consisted of two pairs of "mother-daughter" payloads with limited apogees so that the payloads "hovered" in the sporadic-E region (95-125 km). Each payload pair included vector DC and AC electric field detectors, a highly accurate flux-gate DC magnetometer, an ion mass spectrometer, an ionization gauge, and spaced-electric field receivers to measure the wavelength and phase velocity of the unstable plasma waves. Separate rockets were included to simultaneously carry aloft TMA trails to measure the neutral wind and its velocity shear, believed responsible for the sporadic-E layer formation. In addition to the rocket experiments, incoherent scatter radar measurements of plasma density and drift velocity were gathered almost every night during the 3 week campaign. Continuous VHF backscatter radar operations were carried out from a site near Salinas, Puerto Rico, where 3-m backscatter echoes were observed associated with sporadic-E and other types of low altitude ionospheric layers. Other radars that operated during the campaign included an HF backscatter system near Ponce, Puerto Rico, and a second VHF backscatter radar set up near Aguadila Puerto Rico. On 24 March 1998, one of the instrumented rockets was launched, attaining an apogee of 129 km. The payloads successfully pierced an intense sporadic-E layer observed by both the Arecibo radar and the in-situ density and ion mass spectrometer probes. In-situ DC electric fields revealed very low (about 1-2 mV/m) ambient fields with small amplitude structures of the same order. No high frequency (short scale) waves were observed, consistent with the VHF backscatter observations at the time of the launch. An overview of the observations will be presented.

Pfaff, R.F.

A Sounding Rocket Investigation of the Fine Structure in the Mesopause Region in Conjunction with High Spatial Resolution Lidar Measurements

The grant funds were provided to carry out chemical tracer wind and turbulence measurements in the mesosphere and lower thermosphere as part of the Turbulent Oxygen Mixing Experiment (TOMEX) for which Dr. James Hecht of the Aerospace Corp. was the Principal Investigator. Clemson University designed, built, and tested two chemical tracer release payload sections for the 21.126 and 21.127 payloads which, in addition, had photometer and ionization gauge instrumentation. The tracer chemical was trimethyl aluminum (TMA). The experiment was carried out at White Sands Missile Range in New Mexico on October 26,2000. The location was chosen because of the proximity to the Starfire Optical Range (SOR) which hosted the powerful University of Illinois sodium lidar for an extended period prior to and also during the launch window. Since the SOR telescope is fully steerable, lidar measurements in the same volume sampled by the rocket were possible. The primary objective of the experiment was to measure the turbulent diffusion and mixing in the mesosphere and lower thermosphere, especially in layers characterized by convective and/or dynamical instabilities. The lidar, which is capable of measuring the sodium density, temperatures, and winds with good range and time resolution, provided the launch criteria, as well as context measurements for the in situ rocket observations.

Larsen, M. F.

Plasma Measurements in an Integrated-System FARAD Thruster

Pulsed inductive plasma accelerators are spacecraft propulsion devices in which energy is stored in a capacitor and then discharged through an inductive coil. The device is electrodeless, inducing a current sheet in a plasma located near the face of the coil. The propellant is accelerated and expelled at a high exhaust velocity (order of 10 km/s) through the interaction of the plasma current and the induced magnetic field. The Faraday Accelerator with RF-Assisted Discharge (FARAD) thruster[1,2] is a type of pulsed inductive plasma accelerator in which the plasma is preionized by a mechanism separate from that used to form the current sheet and accelerate the gas. Employing a separate preionization mechanism allows for the formation of an inductive current sheet at much lower discharge energies and voltages than those used in previous pulsed inductive accelerators like the Pulsed Inductive Thruster (PIT). A benchtop FARAD thruster was designed following guidelines and similarity performance parameters presented in Refs. [3,4]. This design is described in detail in Ref. [5]. In this paper, we present the temporally and spatially resolved measurements of the preionized plasma and inductively-accelerated current sheet in the FARAD thruster operating with a Vector Inversion Generator (VIG) to preionize the gas and a Bernardes and Merryman circuit topology to provide inductive acceleration. The acceleration stage operates on the order of 100 J/pulse. Fast-framing photography will be used to produce a time-resolved, global view of the evolving current sheet. Local diagnostics used include a fast ionization gauge capable of mapping the gas distribution prior to plasma initiation; direct measurement of the induced magnetic field using B-dot probes, induced azimuthal current measurement using a mini-Rogowski coil, and direct probing of the number density and electron temperature using triple probes.

Polzin, K. A.

Operational Characteristics and Plasma Measurements in a Low-Energy FARAD Thruster

Pulsed inductive plasma accelerators are spacecraft propulsion devices in which energy is stored in a capacitor and then discharged through an inductive coil. The device is electrodeless, inducing a plasma current sheet in propellant located near the face of the coil. The propellant is accelerated and expelled at a high exhaust velocity (order of 10 km/s) through the interaction of the plasma current with an induced magnetic field. The Faraday Accelerator with RF-Assisted Discharge (FARAD) thruster is a type of pulsed inductive plasma accelerator in which the plasma is preionized by a mechanism separate from that used to form the current sheet and accelerate the gas. Employing a separate preionization mechanism in this manner allows for the formation of an inductive current sheet at much lower discharge energies and voltages than those found in previous pulsed inductive accelerators like the Pulsed Inductive Thruster (PIT). In this paper, we present measurements aimed at quantifying the thruster's overall operational characteristics and providing additional insight into the nature of operation. Measurements of the terminal current and voltage characteristics during the pulse help quantify the output of the pulsed power train driving the acceleration coil. A fast ionization gauge is used to measure the evolution of the neutral gas distribution in the accelerator prior to a pulse. The preionization process is diagnosed by monitoring light emission from the gas using a photodiode, and a time-resolved global view of the evolving, accelerating current sheet is obtained using a fast-framing camera. Local plasma and field measurements are obtained using an array of intrusive probes. The local induced magnetic field and azimuthal current density are measured using B-dot probes and mini-Rogowski coils, respectively. Direct probing of the number density and electron temperature is performed using a triple probe.

Polzin, K. A.

Optically Inaccessible Flow Visualization using Positron Emission Tomography

Flow visualization is a powerful tool for characterizing fluid dynamics within engineering systems that utilize fluid working media. Recent advances in Positron Emission Tomography (PET) have enhanced its ability to extend beyond the medical field, and offer an alternate vantage point in visualizing optically inaccessible fluid distributions and flow fields within the aerospace field. In light of this prospect an investigation has ensued to parametrically bound the flows that can be sufficiently resolved using current PET technology. Results from an initial series of experiments and analyses performed at the Positron Imaging Centre (PIC) located at the University of Birmingham, UK, will be presented. Discussion will also cover preliminary, on-going, activities associated with assessing the utility of PET technology in zero-gravity propellant gauging, ionization efficiency characterization in electric propulsion devices, and broader industrial applications.

PET

Improved fast response pressure gauge for shock reflection studies in ionized gases.

An improved design is presented for a fast response pressure gauge (0.1 microsec risetime) suitable for short duration measurements on the end wall of a shock tube. The design includes standard components to facilitate gauge construction, and it utilizes dual capacitive sensing elements together with a signal differencing scheme to permit use of the gauge in ionized gases. Pressure-time records obtained with the gauge are presented showing details of pressure profiles on the shock tube end wall for reflecting shock waves in ionized gases.

Hanson, R. K.

Introduction to total- and partial-pressure measurements in vacuum systems

An introduction to the fundamentals of total and partial pressure measurement in the vacuum regime (760 x 10 to the -16th power Torr) is presented. The instrument most often used in scientific fields requiring vacuum measurement are discussed with special emphasis on ionization type gauges and quadrupole mass spectrometers. Some attention is also given to potential errors in measurement as well as calibration techniques.

Outlaw, R. A.

A satellite anemometer

This report describes the design, development, and testing of components of a satellite anemometer, an instrument for measuring neutral winds in the upper atmosphere from a satellite platform. The device, which uses four nearly identical pressure sensors, measures the angle of arrival of the bulk neutral flow in the satellite frame of reference. It could also be used in a feedback loop to control spacecraft attitude with respect to the ram velocity direction. We have now developed miniaturized ionization pressure gauges that will work well from the slip flow region near 115 km up to the base of the exosphere, which covers the entire altitude range currently being considered for Tether. Laboratory tests have demonstrated a very linear response to changes in ram angle out to +/- 20 deg. (transverse wind component of 2.7 km s(exp -1)) from the ram, and a monotonic response to out beyond 45 deg. Pitch (vertical wind) and yaw (horizontal wind) can be sampled simultaneously and meaningfully up to 10 Hz. Angular sensitivity of 30 arc seconds (approximately 1 ms(exp -1) is readily attainable, but absolute accuracy for winds will be approximately 1 deg (130 m/s) unless independent attitude knowledge is available. The critical elements of the design have all been tested in the laboratory.

Hanson, W. B.

Gas Pressure Gauge Based on Alpha-Particle Induced Ion Currents

The use of ionization currents for measuring pressure was first demonstrated in the late 1940's. The early gauges operated at high voltages and used rather large ion sources. The ionization gauge is actually a densitometer that is sensitive to the temperature and pressure of the gas in the chamber. This report describes the use of low voltages and small ion sources in the development of a prototype.

transducers gas pressure gauge alpha particles ion

Cold cathode gauge experiment (ALSEP)

Cold cathode ionization gages were left on the lunar surface as part of ALSEP (Apollo Lunar Surface Experiment Package) on Apollo missions 12, 14, and 15. An instrument prepared for Apollo 13 did not reach the surface because of the abort of that mission. The gages that reached the lunar surface measured the amounts of gas present in the vicinity of the ALSEP sites. The observed daytime gas concentrations were initially about two orders of magnitude greater than the nighttime observations; this was due to contamination of the landing area by the Apollo operations and equipment, and the daytime measurements showed a decrease with time characterized by a time constant of a few months.

Johnson, F. S.