Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION DETECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Broad-Band FT-ICR MS for the Penning-Trap Mass Spectrometer MATS

Ion traps are known as ideal tools for precision measurements of fundamental particle properties. In particular, traps have been set up at Radioactive Ion Beam (RIB) facilities to investigate exotic nuclei. During the last decade this field of research has constantly grown, with currently almost a dozen ion-trap systems at RIB facilities in Europe and North America and several more planned at future accelerators projects. One of these, the Advanced Trapping System MATS will be installed at the low-energy branch for radioactive-ion beams at the Facility for Antiprotons and Ion Research (FAIR) in Darmstadt (Germany). One of the MATS features will be non-destructive ion detection based on Fourier-Transform Ion-Cyclotron-Resonance Mass Spectrometry (FT-ICR MS). A prototype of the system has been developed at the Max-Planck-Institute for Nuclear Physics in Heidelberg (Germany) and recent results are outlined in this contribution.

74 ATOMIC AND MOLECULAR PHYSICS↗

Atmospheric Pressure Chemical Ionization Sources Used in The Detection of Explosives by Ion Mobility Spectrometry

Explosives detection is a necessary and wide spread field of research. From large shipping containers to airline luggage, numerous items are tested for explosives every day. In the area of trace explosives detection, ion mobility spectrometry (IMS) is the technique employed most often because it is a quick, simple, and accurate way to test many items in a short amount of time. Detection by IMS is based on the difference in drift times of product ions through the drift region of an IMS instrument. The product ions are created when the explosive compounds, introduced to the instrument, are chemically ionized through interactions with the reactant ions. The identity of the reactant ions determines the outcomes of the ionization process. This research investigated the reactant ions created by various ionization sources and looked into ways to manipulate the chemistry occurring in the sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A versatile electron-ion coincidence spectrometer for photoelectron momentum imaging and threshold spectroscopy on mass selected ions using synchrotron radiation

We present a photoelectron-photoion coincidence (PEPICO) spectrometer named DELICIOUS II which combines a velocity map imaging apparatus with a Wiley-McLaren time of flight analyzer for the study of gas phase samples in interaction with the synchrotron radiation (SR). This versatile system is capable of providing photoelectron images on mass-selected compounds with kinetic energy resolutions of {delta}E/E=5% and a 17 eV bandwidth, as well as threshold photoelectron spectra with a measured resolution of 0.8 meV, as demonstrated on the 3p{sup -1} ionization of argon. This instrument is also employed for threshold PEPICO experiments, allowing the selection of the parent ion's internal state with sub-meV resolution for light masses (<40 amu) and with typically 2 meV resolution for a mass of 100 amu and with a mass resolving power above 200. The continuous operation of the extraction fields and the independence from the electron's time of flight are well adapted to the quasicontinuous multibunch mode of the SR. This, together with the high transmission of both the electron and ion detection, allows a high coincidence counting rate and facilitates the subtraction of false coincidences. We illustrate the spectrometer's coincidence principle of operation with examples from the valence photoionization of an Ar+Xe mixture and of CF{sub 4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular Ion Dissociation Processes in a Partially Cooled Electrostatic Trap

An experimental capability being developed at the Oak Ridge National LaboratoryMulti-Charged Ion Research Facility (ORNL MIRF) is described that enables stored cooling andstate characterization of atomic and molecular ions of essentially any mass. Ions selected from avariety of available (hot and cold) sources are injected into a 1.5 meter long electrostatic mirrortrap, in which excited internal states decay by radiative cooling. Ion lifetime studies or directmeasurements of ‘in-trap’ interactions of molecular ions with electrons or atomic targets areaccomplished with either a crossed electron beam or atomic beam (with recoil ion detection)located in the field-free region of the ion-trap, coupled with product velocity imaging. Similarly,extraction of trap-cooled ions can be used ‘out-of-trap’ for near state-specific electron capture(EC) and dissociative charge exchange (DCE) studies employing higher resolution COLTRIMStechniques coupled with fragment imaging.

74 ATOMIC AND MOLECULAR PHYSICS↗

Mass spectrometric study on inactivation mechanism of spore-forming bacteria by low-pressure surface-wave excited oxygen plasma

In this letter, the etching phenomena of the spore-forming bacteria by oxygen plasma were investigated by using quadrupole mass spectrometry. The etching by-products of H{sub 2}O and CO{sub 2} were obviously detected during the oxygen plasma irradiation by the multiple ion detection measurement. Inactivation of roughly 10{sup 6} spores population was achieved under almost the same reduced spore shapes for three different incident microwave powers. It is considered from the present results that the oxygen radical etching could cause damage to the germinant receptors located in the inner membrane inevitable for germination of spores, without any damage of the DNA in the cores.

60 APPLIED LIFE SCIENCES↗

Simulation study of fast ion losses associated with the rotating n = 1 resonant magnetic perturbations in KSTAR

In this work we describe a simulation framework for testing the fast ion loss mechanism associated with the experimentally observed beam ion losses when an externally applied toroidally rotating perturbed magnetic field is used to control edge localized modes in the KSTAR tokamak. The simulations reproduce the key qualitative features of neutral beam injection (NBI) ion detection by a fast ion loss detector. The NBI ion losses in the simulation mainly occur for passing particles due to orbit stochastization, which is caused by orbit resonance with the 3D field perturbations. The relative toroidal angle of NBI ion deposition to the orbit island determines the radial path of the particles between confinement or loss. The fast ion loss quantity depends on the toroidal angle rotation of the 3D field with respect to the beam deposition position. The averaged transport of toroidal canonical angular momentum reveals that linear and nonlinear resonance of the NBI ions within the 3D field are the main factors determining fast ion transport and loss.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The source of midlatitude metallic ions at F-region altitudes

The results of a survey of metallic ions detected by the Bennett Ion Mass Spectrometer flown on the Atmospheric Explorer satellites are presented and discussed. The nighttime distribution of these ions observed in the F-region at middle latitudes can be accounted for by the presence of fast upward Pederson ion drifts that are produced by intense poleward-directed electric fields with magnitudes typical of those defining subauroral drift events. Such fields, which arise in the vicinity of the main electron density trough at night, result in the rapid movement of long-lived meteoric ions upwards out of their source region into the F-region. Neutral wind drag by the equatorially-directed nightside neutral wind component can lift the ions higher along the field lines until the downward drag of major ion diffusion forces them to layer under F-max.

Grebowsky, J. M.↗

Interplanetary magnetic field sector from Solar Wind Around Pluto (SWAP) measurements of heavy ion pickup near Pluto

On 2015 July 14, the New Horizons spacecraft flew by the Pluto system. The Solar Wind Around Pluto (SWAP) instrument on board New Horizons, which detects ions in the energy per charge range ∼0.035 to 7.5 keV/q, measured the unique interaction between the solar wind and Pluto's atmosphere. Immediately after the closest approach, SWAP detected a burst of heavy ion counts when the instrument's field of view (FOV) was aligned north and south of the Sun–Pluto line and approximately normal to the solar wind flow direction, suggesting their origin as heavy neutral atoms from Pluto that were ionized and being picked up by the solar wind. The trajectories of heavy pickup ions depend on the interplanetary magnetic field (IMF). New Horizons is not equipped with a magnetometer, and we cannot directly measure the IMF. However, we can utilize SWAP's measurements and instrument FOV during this brief period of time to determine the most likely sector of the IMF that could reproduce SWAP's observations of heavy ion pickup. We find that the IMF was most likely in an outward sector, or retrograde to the planets’ motion, during the Pluto encounter, and that the heavy ions detected by SWAP are more likely CH{sub 4}{sup +} than N{sub 2}{sup +}. This supports the existence of a methane exosphere at Pluto.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observing quantum gases in real time: Single-atom detection on a chip

Single magnetically trapped {sup 87}Rb atoms on an atom chip are detected with 67{+-}12 % efficiency by three photon ionization and subsequent ion detection in a channel electron multiplier. State selective detection of single atoms and high-resolution optical spectroscopy on trapped atom clouds are demonstrated. The temperature and particle density of a trapped atomic gas is monitored in situ and in real time with negligible atom loss due to ionization below 5%.

74 ATOMIC AND MOLECULAR PHYSICS↗

Towards intrinsic MoS{sub 2} devices for high performance arsenite sensing

Molybdenum disulphide (MoS{sub 2}) is one of the most attractive two dimensional materials other than graphene, and the exceptional properties make it a promising candidate for bio/chemical sensing. Nevertheless, intrinsic properties and sensing performances of MoS{sub 2} are easily masked by the presence of the Schottky barrier (SB) at source/drain electrodes, and its impact on MoS{sub 2} sensors remains unclear. Here, we systematically investigated the influence of the SB on MoS{sub 2} sensors, revealing the sensing mechanism of intrinsic MoS{sub 2}. By utilizing a small work function metal, Ti, to reduce the SB, excellent electrical properties of this 2D material were yielded with 2–3 times enhanced sensitivity. We experimentally demonstrated that the sensitivity of MoS{sub 2} is superior to that of graphene. Intrinsic MoS{sub 2} was able to realize rapid detection of arsenite down to 0.1 ppb without the influence of large SB, which is two-fold lower than the World Health Organization (WHO) tolerance level and better than the detection limit of recently reported arsenite sensors. Additionally, accurately discriminating target molecules is a great challenge for sensors based on 2D materials. This work demonstrates MoS{sub 2} sensors encapsulated with ionophore film which only allows certain types of molecules to selectively permeate through it. As a result, multiplex ion detection with superb selectivity was realized. Our results show prominent advantages of intrinsic MoS{sub 2} as a sensing material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation of Unidirectional Ion Ejection in an Asymmetric Half-Round Rod Electrode Linear Ion Trap Mass Analyzer

An asymmetric trapping field was generated from an asymmetric half-round rod electrode linear ion trap (A-HreLIT), and its performance of unidirectional ion ejection was studied. Two different asymmetric structures of A-HreLITs were constructed, one rotating y electrode pairs toward an x electrode with an angle θ, and the other stretching one x electrode with a distance α. The center of trapping field was displaced away from the geometrical center of the ion trap, defined to be the midpoint along the axis of y between x electrodes, which leads to unidirectional ion ejection through one x electrode. Computer simulations were used to investigate the relationship between asymmetric geometric parameter of θ (or α) and analytical performance. Both structures could result in similar asymmetric trapping fields, which mainly composed of dipole, quadrupole, and hexapole fields. The dipole and hexapole fields were approximately proportional to the asymmetric geometric parameter of rotation angle θ (or stretch distance α). In simulation, ion trajectories and ion kinetic energy were calculated. For ions with m/z 609 Th, the simulation results showed that mass resolution of over 2400 (FWHM) and ion unidirectional ejection efficiency of nearly 90% were achieved in an optimized A-HreLIT. Ion detection efficiency of A-HreLIT could be improved significantly with only one ion detector, while maintaining a considerable mass resolution. Furthermore, the A-HreLIT could be driven by a traditional balanced RF power supply. These advantages make A-HreLIT suitable for developing miniaturized mass spectrometer with high performance. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An algorithm to correct saturated mass spectrometry ion abundances for enhanced quantitation and mass accuracy in omic studies

The mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can easily cause problems if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flight MS. In this method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases with highly saturated species and dynamic range increased by 1-2 orders of magnitude for peptides in a blood serum sample.

Environmental Molecular Sciences Laboratory↗

Barium Chemosensors with Dry-Phase Fluorescence for Neutrinoless Double Beta Decay

The nature of the neutrino is one of the major open questions in experimental nuclear and particle physics. The most sensitive known method to establish the Majorana nature of the neutrino is detection of the ultra-rare process of neutrinoless double beta decay. However, identification of one or a handful of decay events within a large mass of candidate isotope, without obfuscation by backgrounds is a formidable experimental challenge. One hypothetical method for achieving ultra- low-background neutrinoless double beta decay sensitivity is the detection of single 136 Ba ions produced in the decay of 136 Xe (“barium tagging”). To implement such a method, a single-ion-sensitive barium detector must be developed and demonstrated in bulk liquid or dry gaseous xenon. This paper reports on the development of two families of dry-phase barium chemosensor molecules for use in high pressure xenon gas detectors, synthesized specifically for this purpose. One particularly promising candidate, an anthracene substituted aza-18-crown-6 ether, is shown to respond in the dry phase with almost no intrinsic background from the unchelated state, and to be amenable to barium sensing through fluorescence microscopy. This interdisciplinary advance, paired with earlier work demonstrating sensitivity to single barium ions in solution, opens a new path toward single ion detection in high pressure xenon gas.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crystallographic Characterization of Sodium Ions in a Bacterial Leucine/Sodium Symporter

Na + is the most abundant ion in living organisms and plays essential roles in regulating nutrient uptake, muscle contraction, and neurotransmission. The identification of Na + in protein structures is crucial for gaining a deeper understanding of protein function in a physiological context. LeuT, a bacterial homolog of the neurotransmitter:sodium symporter family, uses the Na + gradient to power the uptake of amino acids into cells and has been used as a paradigm for the study of Na + -dependent transport systems. We have devised a low-energy multi-crystal approach for characterizing low-Z (Z ≤ 20) anomalous scattering ions such as Na + , Mg 2+ , K + , and Ca 2+ by combining Bijvoet-difference Fourier syntheses for ion detection and f” refinements for ion speciation. Using the approach, we experimentally identify two Na + bound near the central leucine binding site in LeuT. Using LeuT microcrystals, we also demonstrate that Na + may be depleted to study conformational changes in the LeuT transport cycle.

59 BASIC BIOLOGICAL SCIENCES↗

Gain Switching for a Detection System to Accommodate a Newly Developed MALDI-Based Quantification Method

In matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF), matrix-derived ions are routinely deflected away to avoid problems with ion detection. This, however, limits the use of a quantification method that utilizes the analyte-to-matrix ion abundance ratio. In this work, we will show that it is possible to measure this ratio by a minor instrumental modification of a simple form of MALDI-TOF. This involves detector gain switching. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗