Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Entanglement enabled intensity interferometry in ultrarelativistic ultraperipheral nuclear collisions

An important tool in studying the subfemtoscale spacetime structure of matter in ultrarelativistic heavy-ion collisions is Hanbury Brown–Twiss (HBT) intensity interferometry of identical particles in the final state of the collisions. We propose that a variant of the entanglement enabled intensity interferometry (𝐸 2 ⁢𝐼 2 ) framework introduced by Cotler and Wilczek can provide a powerful alternative to HBT interferometry in extracting fundamental nonperturbative features of quantum chromodynamics at high energies. We apply this framework to demonstrate that the spatial distributions of color singlet (pomeron) configurations in nuclei are sensitive to measurements of exclusive resonant decays of 𝜌 mesons into 𝜋 ± pairs in ultrarelativistic ultraperipheral nuclear collisions (UPCs) at the Relativistic Heavy Ion Collider and the Large Hadron Collider. A preliminary analysis suggests that the model-independent extraction of pomeron distributions will require careful treatment of the interplay of 𝐸 2 ⁢𝐼 2 in the vector meson exclusive decay with the incoherent cross section for exclusive vector meson production. The 𝐸 2 ⁢𝐼 2 framework developed here is quite general. It can also be employed as a tool to extract information on the spin structure of pomeron couplings as well as enhance the discovery potential for rare odderon configurations from exclusive vector meson decays into few-particle final states both in UPCs and at the Electron-Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two-dimensional stitching interferometry for self-calibration of high-order additive systematic errors

Stitching interferometry is performed by collecting interferometric data from overlapped sub-apertures and stitching these data together to provide a full surface map. The propagation of the systematic error in the measured subset data is one of the main error sources in stitching interferometry for accurate reconstruction of the surface topography. In this work, we propose, using the redundancy of the captured subset data, two types of two-dimensional (2D) self-calibration stitching algorithms to overcome this issue by in situ estimating the repeatable high-order additive systematic errors, especially for the application of measuring X-ray mirrors. The first algorithm, called CS short for “Calibrate, and then Stitch”, calibrates the high-order terms of the reference by minimizing the de-tilted discrepancies of the overlapped subsets and then stitches the reference-subtracted subsets. The second algorithm, called SC short for “Stitch, and then Calibrate”, stitches a temporarily result and then calibrates the reference from the de-tilted discrepancies of the measured subsets and the temporarily stitched result. In the implementation of 2D scans in $x$- and y -directions, step randomization is introduced to generate nonuniformly spaced subsets which can diminish the periodic stitching errors commonly observed in evenly spaced subsets. The regularization on low-order terms enables a highly flexible option to add the curvature and twist acquired by another system. Both numerical simulations and experiments are carried out to verify the proposed method. All the results indicate that 2D high-order repeatable additive systematic errors can be retrieved from the 2D redundant overlapped data in stitching interferometry.

42 ENGINEERING↗

A Range and Performance Optimized Version of the Computer-Aided Speckle Interferometry Algorithm for Real-Time Displacement-Strain Field Monitoring

Abstract This work presents an optimized implementation of the Computer-Aided Speckle Interferometry algorithm which enables full-field determination of displacements and strains on commodity Graphics Processing Units at high resolution and frame rates. By combining careful control of the average speckle size in a laser speckle pattern with a simple sampling rate conversion scheme, a compact representation of the optical speckle is achieved. This allows for optimal use of Graphics Processing Unit architecture with robust range extension. The optimal mapping of the Computer-Aided Speckle Interferometry algorithm to Graphics Processing Unit architecture is shown in detail, and a straightforward method for disambiguating large displacements is illustrated. Lastly, this paper demonstrates a two-step subimage-tapering modification to the original algorithm that enables robust range enhancement while maintaining resolution. Results from numerical simulations on synthetic speckle patterns are shown, and runtime performance metrics are provided, with performance ranging up to 60 frames per second in some cases. The method is suitable for interactive experimental mechanics research, process and testing or any application where real-time high-resolution displacement-strain monitoring is needed. A .NET Framework class library enabling the incorporation of the algorithm into 3rd -party applications is available for download.

42 ENGINEERING↗

One-dimensional stitching interferometry assisted by a triple-beam interferometer

In this work, we proposed for stitching interferometry to use a triple-beam interferometer to measure both the distance and the tilt for all sub-apertures before the stitching process. The relative piston between two neighboring sub-apertures is then calculated by using the data in the overlapping area. Comparisons are made between our method, and the classical least-squares principle stitching method. Our method can improve the accuracy and repeatability of the classical stitching method when a large number of sub-aperture topographies are taken into account. Our simulations and experiments on flat and spherical mirrors indicate that our proposed method can decrease the influence of the interferometer error from the stitched result. The comparison of stitching system with Fizeau interferometry data is about 2 nm root mean squares and the repeatability is within ± 2.5 nm peak to valley.

47 OTHER INSTRUMENTATION↗

Mutual Diffusion Coefficients of Na 2 SO 4 at C = 0.02989 mol·dm -3 and 298.15 K by Using Rayleigh Interferometry with Free Diffusion Boundary Conditions: Experimental Test of the Effect of the C 3/2 Concentration Dependence of Refractive Index at Low Concentration

Rayleigh interferometry is one of the most precise and accurate methods for the experimental determination of the mutual diffusion coefficients of both electrolytes and non-electrolytes in liquid solutions. For binary solutions at moderate and high concentrations where the concentration dependences of both diffusion coefficient and refractive index can be assumed to be linear or almost linear and the concentration difference ΔC between a pair of solutions undergoing free diffusion is not large compared to their average concentration, and by using proper combinations of the interference fringe positions as they vary with time, under these conditions diffusion coefficients are obtained that are independent of the size of ΔC. However, this situation becomes more complicated at low concentrations for electrolyte solutions where the concentration dependences of both the diffusion coefficient and refractive index are non-linear, with C 1/2 dependence for the diffusion coefficient and C 3/2 dependence for the refractive index. As a test of these effects on calculated mutual diffusion of electrolyte solutions at low concentrations as measured by Rayleigh interferometry, apparent mutual diffusion coefficients D v,a (volume-fixed reference frame) were measured for fixed average concentrations C=(0.02989 ± 0.00001) mol·dm –3 of Na 2 SO 4 (aq) at 298.15 K while varying ΔC/C from 0.66673 to 2, a threefold variation. The dependence of the diffusion coefficient on ΔC/C was found to be linear, yielding D v = 1.041 6 × 10 –9 m 2 ·s –1 for an infinitely small concentration difference between the diffusing solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cement paste surface roughness analysis using coherence scanning interferometry and confocal microscopy

Scanning electron microscopy and scanning probe microscopy have been used for several decades to better understand the microstructure of cementitious materials. Very limited work has been performed to date to study the roughness of cementitious materials by optical microscopy such as coherence scanning interferometry (CSI) and chromatic confocal sensing (CCS). The objective of this paper is to better understand how CSI can be used as a tool to analyze surface roughness and topography of cement pastes. Observations from a series of images acquired using this technique on both polished and unpolished samples are described. The results from CSI are compared with those from a STIL confocal microscopy technique (SCM). Comparison between both optical techniques demonstrates the ability of CSI to measure both polished and unpolished cement pastes. - Highlights: • Coherence scanning interferometry (CSI) was used to analyze cement paste surfaces. • The results from the CSI were compared with those from a confocal microscopy. • 3D roughness parameters were obtained using the window resizing method. • Polished and unpolished cement pastes were studied.

36 MATERIALS SCIENCE↗

Actively stabilized optical fiber interferometry technique for online/in-process surface measurement

In this paper, we report the recent progress in optical-beam scanning fiber interferometry for potential online nanoscale surface measurement based on the previous research. It attempts to generate a robust and miniature measurement device for future development into a multiprobe array measurement system. In this research, both fiber-optic-interferometry and the wavelength-division-multiplexing techniques have been used, so that the optical probe and the optical interferometer are well spaced and fast surface scanning can be carried out, allowing flexibility for online measurement. In addition, this system provides a self-reference signal to stabilize the optical detection with high common-mode noise suppression by adopting an active phase tracking and stabilization technique. Low-frequency noise was significantly reduced compared with unstabilized result. The measurement of a sample surface shows an attained repeatability of 3.3 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The potential for intensity interferometry with {gamma}-ray telescope arrays

Intensity interferometry exploits a quantum optical effect in order to measure objects with extremely small angular scales. The first experiment to use this technique was the Narrabri intensity interferometer, which was successfully used in the 1970s to measure 32 stellar diameters at optical wavelengths; some as small as 0.4 milli-arcseconds. The advantage of this technique, in comparison with Michelson interferometers, is that it requires only relatively crude, but large, light collectors equipped with fast (nanosecond) photon detectors. Ground-based {gamma}-ray telescope arrays have similar specifications, and a number of these observatories are now operating worldwide, with more extensive installations planned for the future. These future instruments (CTA, AGIS, completion 2015) with 30-90 telescopes will provide 400-4000 different baselines that range in length between 50 m and a kilometre. Intensity interferometry with such arrays of telescopes attains 50 {mu}-arcsecond resolution for a limiting m{sub v}{approx}8.5. Phase information can be extracted from the interferometric measurement with phase closure, allowing image reconstruction. This technique opens the possibility of a wide range of studies amongst others, probing the stellar surface activity and the dynamic AU scale circumstellar environment of stars in various crucial evolutionary stages. Here we focuse on the astrophysical potential of an intensity interferometer utilising planned new {gamma}-ray instrumentation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-chord fiber-coupled interferometry of supersonic plasma jets andcomparisons with synthetic data

A multi-chord fiber-coupled interferometer [Merritt et al., Rev. Sci. Instrum. 83, 033506 (2012)] is being used to make time-resolved density measurements of supersonic argon plasma jets on the Plasma Liner Experiment [Hsu et al., Bull. Amer. Phys. Soc. 56, 307 (2011)]. The long coherence length of the laser (> 10 m) allows signal and reference path lengths to be mismatched by many meters without signal degradation, making for a greatly simplified optical layout. Measured interferometry phase shifts are consistent with a partially ionized plasma in which an initially positive phase shift becomes negative when the ionization fraction drops below a certain threshold. In this case, both free electrons and bound electrons in ions and neutral atoms contribute to the index of refraction. This paper illustrates how the interferometry data, aided by numerical modeling, are used to derive total jet density, jet propagation velocity ({approx} 15-50 km/s), jet length ({approx} 20-100 cm), and 3D expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Core density gradient fluctuation measurement by differential interferometry in the helically symmetric experiment stellarator

The interferometer system on the Helically Symmetric eXperiment (HSX) stellarator uses an expanded beam and linear detector array to realize a multichord measurement. Unlike conventional interferometry which determines the plasma phase shift with respect to a reference, directly evaluating the phase between two adjacent chords can be employed to measure the change in plasma phase with impact parameter. This approach provides a measure of the equilibrium density gradient or the density gradient fluctuations and is referred to as differential interferometry. For central chords, measurements are spatially localized due to a geometrical weighting factor and can provide information on core density gradient fluctuations. The measurement requires finite coherence between fluctuations in the two spatially offset chords. This technique is applied on the HSX stellarator to measure both broadband turbulence and coherent modes. Spatial localization is exploited to isolate core turbulence changes associated with change in magnetic configuration or heating location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-chord fiber-coupled interferometry of supersonic plasma jets (invited)

A multi-chord fiber-coupled interferometer is being used to make time-resolved density measurements of supersonic argon plasma jets on the Plasma Liner Experiment. The long coherence length of the laser (>10 m) allows signal and reference path lengths to be mismatched by many meters without signal degradation, making for a greatly simplified optical layout. Measured interferometry phase shifts are consistent with a partially ionized plasma in which both positive and negative phase shift values are observed depending on the ionization fraction. In this case, both free electrons and bound electrons in ions and neutral atoms contribute to the index of refraction. This paper illustrates how the interferometry data, aided by numerical modeling, are used to derive total jet density, jet propagation velocity ({approx}15-50 km/s), jet length ({approx}20-100 cm), and 3D expansion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility test of Z{sub eff} imaging using x-ray interferometry

Elemental imaging using X-ray interferometry has been developed. Since the atomic number (Z) of a single-element sample (effective atomic number (Z{sub eff}) for a plural-element sample) corresponds to the ratio of the real to imaginary part of the complex refractive index, an elemental map is calculable with the ratio of an absorption and phase-contrast image. Several metal foils underwent feasibility observations by crystal X-ray interferometry, providing accurate detection of X-ray intensity and phase-shift. The obtained Z{sub eff} image shows that aluminum, iron, nickel, and copper foil were clearly distinguished, and nickel and copper's Z{sub eff} values coincide with ideal Z number within 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visual investigation on the heat dissipation process of a heat sink by using digital holographic interferometry

We present a method for visually and quantitatively investigating the heat dissipation process of plate-fin heat sinks by using digital holographic interferometry. A series of phase change maps reflecting the temperature distribution and variation trend of the air field surrounding heat sink during the heat dissipation process are numerically reconstructed based on double-exposure holographic interferometry. According to the phase unwrapping algorithm and the derived relationship between temperature and phase change of the detection beam, the full-field temperature distributions are quantitatively obtained with a reasonably high measurement accuracy. And then the impact of heat sink's channel width on the heat dissipation performance in the case of natural convection is analyzed. In addition, a comparison between simulation and experiment results is given to verify the reliability of this method. The experiment results certify the feasibility and validity of the presented method in full-field, dynamical, and quantitative measurement of the air field temperature distribution, which provides a basis for analyzing the heat dissipation performance of plate-fin heat sinks.

42 ENGINEERING↗

2D image of local density and magnetic fluctuations from line-integrated interferometry-polarimetry measurements

Combined polarimetry-interferometry capability permits simultaneous measurement of line-integrated density and Faraday effect with fast time response (∼1 μs) and high sensitivity. Faraday effect fluctuations with phase shift of order 0.05° associated with global tearing modes are resolved with an uncertainty ∼0.01°. For physics investigations, local density fluctuations are obtained by inverting the line-integrated interferometry data. The local magnetic and current density fluctuations are then reconstructed using a parameterized fit of the polarimetry data. Reconstructed 2D images of density and magnetic field fluctuations in a poloidal cross section exhibit significantly different spatial structure. Combined with their relative phase, the magnetic-fluctuation-induced particle transport flux and its spatial distribution are resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray grating interferometry at photon energies over 180 keV

We report on the implementation and characterization of grating interferometry operating at an x-ray energy of 183 keV. With the possibility to use this technique at high x-ray energies, bigger specimens could be studied in a quantitative way. Also, imaging strongly absorbing specimens will benefit from the advantages of the phase and dark-field signals provided by grating interferometry. However, especially at these high photon energies the performance of the absorption grating becomes a key point on the quality of the system, because the grating lines need to keep their small width of a couple of micrometers and exhibit a greater height of hundreds of micrometers. The performance of high aspect ratio absorption gratings fabricated with different techniques is discussed. Further, a dark-field image of an alkaline multicell battery highlights the potential of high energy x-ray grating based imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photoacoustic tomography based on the Green's function retrieval with ultrasound interferometry for sample partially behind an acoustically scattering layer

Acoustically inhomogeneous mediums with multiple scattering are often the nightmare of photoacoustic tomography. In order to break this limitation, a photoacoustic tomography scheme combining ultrasound interferometry and time reversal is proposed to achieve images in acoustically scattering medium. An ultrasound interferometry is developed to determine the unknown Green's function of strong scattering tissue. Using the determined Greens' function, a time-reversal process is carried out to restore images behind an acoustically inhomogeneous layer from the scattering photoacoustic signals. This method effectively decreases the false contrast, noise, and position deviation of images induced by the multiple scattering. Phantom experiment is carried out to validate the method. Therefore, the proposed method could have potential value in extending the biomedical applications of photoacoustic tomography in acoustically inhomogeneous tissue.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using simultaneous x-ray diffraction and velocity interferometry to determine material strength in shock-compressed diamond

We determine the strength of laser shock-compressed polycrystalline diamond at stresses above the Hugoniot elastic limit using a technique combining x-ray diffraction from the Linac Coherent Light Source with velocity interferometry. X-ray diffraction is used to measure lattice strains, and velocity interferometry is used to infer shock and particle velocities. These measurements, combined with density-dependent elastic constants calculated using density functional theory, enable determination of material strength above the Hugoniot elastic limit. Furthermore, our results indicate that diamond retains approximately 20 GPa of strength at longitudinal stresses of 150–300 GPa under shock compression.

36 MATERIALS SCIENCE↗

Increase in the sensitivity of holographic reversible shearing interferometry by turning around an object

It is shown that a turn of an object in holographic reversible shearing interferometry in the case of objects with linear dimensions not exceeding half the diameter of a probe light beam allows the doubling of the sensitivity of interferograms mapping changes in a wavefront caused by the object. The interference patterns of a glass test plate with the doubled sensitivity of inhomogeneity mapping obtained by this method are presented. (holographic interferometry)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗