Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hydrogen Concentration Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Oligonucleotides as probes for studying polymerization reactions in dilute aqueous solution: II. Polycondensations

We have prepared a [32P]-labeled oligonucleotide probe carrying a ureido (-NH-CO-NH2) function at its 3'-terminus. This labeled oligomer was used to study polycondensations of urea and formaldehyde and of various phenols and formaldehyde in aqueous solution. The formation of formaldehyde copolymers attached to the amido-function of the probe was monitored by gel electrophoresis. Our results are generally in agreement with those obtained using conventional techniques. Our method is suitable for monitoring potentially prebiotic polycondensation reactions involving formaldehyde.

NASA Discipline Exobiology↗

Anomalous phase separation behavior of gel-derived soda-silica glasses

The effects of retained bound hydroxyl groups on amorphous immiscibility behavior and on the kinetics of phase separation were studied in glasses containing from 10 to 19 percent sodium oxide preparaed by the gel process. Differences in behavior as functions of preliminary thermal treatment of the gel precursor and of melting conditions were studied, employing IR spectroscopy, SAXS and WAXD to monitor the variation in glass microstructure. Both the initial gel treatment and the OH concentration in the prepared glasses were found to affect the immiscibility temperatures, and the magnitude of the maximum temperature increase was also a function of the sodium oxide concentration. It is suggested that the variation in thermodynamic behavior may be caused by the structural arrangement attained by the OH groups during the gel condensation process, which in turn affects the extent of hydrogen bonding to nonbridging oxygen ions.

Neilson, G. F.↗

Automated Hydrogen Gas Leak Detection System

The Gencorp Aerojet Automated Hydrogen Gas Leak Detection System was developed through the cooperation of industry, academia, and the Government. Although the original purpose of the system was to detect leaks in the main engine of the space shuttle while on the launch pad, it also has significant commercial potential in applications for which there are no existing commercial systems. With high sensitivity, the system can detect hydrogen leaks at low concentrations in inert environments. The sensors are integrated with hardware and software to form a complete system. Several of these systems have already been purchased for use on the Ford Motor Company assembly line for natural gas vehicles. This system to detect trace hydrogen gas leaks from pressurized systems consists of a microprocessor-based control unit that operates a network of sensors. The sensors can be deployed around pipes, connectors, flanges, and tanks of pressurized systems where leaks may occur. The control unit monitors the sensors and provides the operator with a visual representation of the magnitude and locations of the leak as a function of time. The system can be customized to fit the user's needs; for example, it can monitor and display the condition of the flanges and fittings associated with the tank of a natural gas vehicle.

Source record↗

Hydrogen chloride measurements in the Space Shuttle exhaust cloud - First launch, April 12, 1981

Partitioning of hydrogen chloride between the aerosol and gaseous phases in the first Space Shuttle exhaust cloud was experimentally investigated as the exhaust cloud was diluted with ambient air. Airborne measurements were obtained of gaseous hydrogen chloride (HCl), total HCl, relative humidity, and temperature to determine the conditions controlling HCl aerosol formation in the Shuttle exhaust cloud. Two segments of the cloud, each at a significantly different relative humidity, were monitored. Equilibrium predictions of HCl aerosol formation agreed with the measured HCl partitioning at the higher and lower relative humidity conditions, but do not agree at the aerosol formation threshold region. Measurements were taken in the Shuttle exhaust cloud from 8.6 min until 2 h and 8 min after launch. HCl concentrations ranged from 17.5 to 0.9 ppm and relative humidity from 86% to less than 10%.

Sebacher, D. I.↗

Lightweight, direct-radiating nickel hydrogen batteries

Two battery module configurations were developed which, in addition to integrating cylindrical nickel hydrogen (NiH2) cells into batteries, provide advances in the means of mounting, monitoring and thermal control of these cells. The main difference between the two modules is the physical arrangement of the cells: vertical versus horizontal. Direct thermal radiation to deep space is accomplished by substituting the battery structure for an exterior spacecraft panel. Unlike most conventional nickel-cadmium (NiCd) and NiH2 batteries, the cells are not tightly packed together; therefore ancillary heat conducting media to outside radiating areas, and spacecraft deck reinforcements for high mass concentration are not necessary. Testing included electrical characterization and a comprehensive regime of environmental exposures. The designs are flexible with respect to quantity and type of cells, orbit altitude and period, power demand profile, and the extent of cell parameter monitoring. This paper compares the characteristics of the two battery modules and summarizes their performance.

Metcalfe, J. R.↗

Development of a six-man, self-contained carbon dioxide collection subsystem for spacecraft application

Life Systems, working with NASA, has developed an electrochemical, six-man, self-contained carbon dioxide concentrator subsystem (CX-6) designed to normally remove 13.2 lb/day of CO2 while maintaining the CO2 partial pressure (pCO2) of the cabin atmosphere at 3 mm Hg or less. The CX-6 was subjected to extensive parametric and endurance testing. The effects of operating conditions on CO2 removal and electrical efficiencies were determined, including effects of hydrogen (H2) flow rate, process airflow rate, pCO2, operating temperature and current density. A total of 209 days of operation was accumulated. The subsystem was designed with self-contained electronic control and monitoring instrumentation. The CX-6 was redesigned and repackaged into the CO2 collection subsystem for the air revitalization group of the space station prototype.

Schubert, F. H.↗

Microcalorimetric Measurements of Hydrogen Peroxide Stability

Recent interest in propellants with nontoxic reaction products has led to a resurgence of interest in hydrogen peroxide for various propellant applications. Because hydrogen peroxide is sensitive to contaminants and materials interactions, stability and shelf life are issues. A relatively new, ultrasensitive heat measurement technique, isothermal microcalorimetry, is being used at the White Sands Test Facility to monitor the decomposition of hydrogen peroxide at near ambient temperatures. Isothermal microcalorimetry measures the beat flow from a reaction vessel into a surrounding heat sink. In these applications, microcalorimetry is approximately 1,000 times more sensitive than accelerating rate calorimetry or differential scanning calorimetry for measuring thermal events. Experimental procedures have been developed for the microcalorimetric measurement of the ultra-small beat effects caused by incompatible interactions of hydrogen peroxide. The decomposition rates of hydrogen peroxide at the picomole/sec/gram level have been measured showing the effects of stabilizers and peroxide concentration. Typical measurements are carried out at 40 C over a 24-hour period, This paper describes a method for the conversion of the heat flow measurements to chemical reaction rates based on thermochemical considerations. The reaction rates are used in a study of the effects of stabilizer levels on the decomposition of propellant grade hydrogen peroxide.

Davis, Dennis D.↗

Chemical Challenge Tests on ISS Fire Cartridges

Following a confirmed combustion event onboard the International Space Station (ISS), crewmembers will don Emergency Masks, each fitted with 2 ISS fire cartridge filters. As the crewmember breathes through the filters, combustion products in the cabin air are either filtered or catalyzed by the fire cartridge media to minimize crew exposure to harmful levels of contaminants. Rigorous certification, acceptance, and surveillance programs for the fire cartridges ensure that each lot meets stringent performance requirements during the beginning of and throughout the service life of the cartridges. In accordance with the Quality/Acceptance Test Plan, multiple fire cartridges from each lot undergo chemical challenge tests, with each test lasting 2.5 hours and involving one or more chemicals at specified concentrations. These tests are conducted at specific temperatures, humidity levels, and gas flow rates intended to mimic the worst-case conditions for fire cartridge performance. These challenge tests are conducted by the Environmental Chemistry Laboratory at the NASA Lyndon B. Johnson Space Center. The majority of the challenge tests focus on carbon monoxide (CO), but other gases include hydrogen cyanide (HCN), hydrogen chloride (HCl), cyclohexane, acrolein, and acetaldehyde. A fire cartridge is exposed to the test gas in a test chamber at the specified conditions and the outlet is monitored for breakthrough during the 2.5-hour test. This paper will briefly introduce fire cartridges and how they work, then discuss details of the challenge gas delivery and exposure system, breakthrough monitoring methods, and discussion of issues that have arisen during the course of the test program. Although the focus of this paper will be on the conduction of the challenge tests, a general summary of the performance of the fire cartridges will be provided.

Fire Cartridge↗

Chemical Challenge Tests on ISS Fire Cartridges

Following a confirmed combustion event onboard the International Space Station (ISS), crew members will don Emergency Masks, each fitted with 2 ISS fire cartridge filters. As the crew member breathes through the filters, combustion products in the cabin air are either filtered or catalyzed by the fire cartridge media to minimize crew exposure to harmful levels of contaminants. Rigorous certification, acceptance, and surveillance programs for the fire cartridges ensure that each lot meets stringent performance requirements throughout the service life of the cartridges. In accordance with the Quality/Acceptance Test Plan, multiple fire cartridges from each lot undergo chemical challenge tests involving one or more chemicals at specified concentrations. These tests are conducted at specific temperatures, humidity levels, and gas flow rates intended to mimic the worst-case conditions for fire cartridge performance. These challenge tests are conducted by the Environmental Chemistry- Laboratory at the NASA Lyndon B. Johnson Space Center. Many of the challenge tests focus on carbon monoxide (CO), but other gases include hydrogen cyanide (HCN), hydrogen chloride (HCl), cyclohexane, acrolein, ammonia (NH3), and acetaldehyde. A fire cartridge is exposed to the test gas in a chamber at the specified conditions, and the outlet is monitored for breakthrough during the 2.5-hour test. This paper will briefly introduce fire cartridges and how they work and will then discuss details of the challenge gas delivery and exposure system, breakthrough monitoring methods, and discussion of issues that have arisen during the course of the test program. Although the focus of this paper will be on the challenge tests, a general summary of the performance of the fire cartridges will also be provided.

Cristina M. Muko↗

Composite Cryotank Technologies and Development 2.4 and 5.5M out of Autoclave Tank Test Results

The Composite Cryotank Technologies and Demonstration (CCTD) project substantially matured composite, cryogenic propellant tank technology. The project involved the design, analysis, fabrication, and testing of large-scale (2.4-m-diameter precursor and 5.5-m-diameter) composite cryotanks. Design features included a one-piece wall design that minimized tank weight, a Y-joint that incorporated an engineered material to alleviate stress concentration under combined loading, and a fluted core cylindrical section that inherently allows for venting and purging. The tanks used out-of-autoclave (OoA) cured graphite/epoxy material and processes to enable large (up to 10-m-diameter) cryotank fabrication, and thin-ply prepreg to minimize hydrogen permeation through tank walls. Both tanks were fabricated at Boeing using automated fiber placement on breakdown tooling. A fluted core skirt that efficiently carried axial loads and enabled hydrogen purging was included on the 5.5-m-diameter tank. Ultrasonic inspection was performed, and a structural health monitoring system was installed to identify any impact damage during ground processing. The precursor and 5.5-m-diameter tanks were tested in custom test fixtures at the National Aeronautics and Space Administration Marshall Space Flight Center. The testing, which consisted of a sequence of pressure and thermal cycles using liquid hydrogen, was successfully concluded and obtained valuable structural, thermal, and permeation performance data. This technology can be applied to a variety of aircraft and spacecraft applications that would benefit from 30 to 40% weight savings and substantial cost savings compared to aluminum lithium tanks.

Jackson, Justin R.↗

Effect of alcohol addition on shock-initiated formation of soot from benzene

Soot formation in benzene-methanol and benzene-ethanol argon-diluted mixtures was studied behind reflected shock waves by monitoring the attenuation of an He-Ne laser beam. The experiments were performed at temperatures 1580-2250 K, pressures 2.0-3.0 bar, and total carbon atom concentrations (2.0-2.7) x 10 to the 17th atoms/cu cm. The results obtained indicate that the addition of alcohol suppresses the formation of soot from benzene at all temperatures, and that the reduction in soot yields is increased with the amount of alcohol added. The analysis of the results indicates that the suppression effect is probably due to the oxidation of soot and soot precursors by OH and the removal of hydrogen atoms by alcohol and water molecules.

Frenklach, Michael↗

Tape Cassette Bacteria Detection System

The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

Source record↗

Investigation of the applicability of using the triple redundant hydrogen sensor for methane sensing

Application specifications for the methane sensor were assembled and design guidelines, development goals and evaluation criteria were formulated. This was done to provide a framework to evaluate sensor performance and any design adjustments to the preprototype sensor that could be required to provide methane sensitivity. Good response to hydrogen was experimentally established for four hydrogen sensor elements to be later evaluated for methane response. Prior results were assembled and analyzed for other prototype hydrogen sensor performance parameters to form a comparison base. The four sensor elements previously shown to have good hydrogen response were experimentally evaluated for methane response in 2.5% methane-in-air. No response was obtained for any of the elements, despite the high methane concentration used (50% of the Lower Flammability Limit). It was concluded that the preprototype sensing elements were insensitive to methane and were hydrogen specific. Alternative sensor operating conditions and hardware design changes were considered to provide methane sensitivity to the preprototype sensor, including a variety of different methane sensing techniques. Minor changes to the existing sensor elements, sensor geometry and operating conditions will not make the preprototype hydrogen sensor respond to methane. New sensor elements that will provide methane and hydrogen sensitivity require replacement of the existing thermistor type elements. Some hydrogen sensing characteristics of the modified sensor will be compromised (larger in situ calibration gas volume and H2 nonspecificity). The preprototype hydrogen sensor should be retained for hydrogen monitoring and a separate methane sensor should be developed.

Lantz, J. B.↗

Hydrocarbon polymeric binder for advanced solid propellant

A series of DEAB initiated isoprene polymerizations were run in the 5-gallon stirred autoclave reactor. Polymerization run parameters such as initiator concentration and feed rate were correlated with the molecular weight to provide a basis for molecular weight control in future runs. Synthetic methods were developed for the preparation of n-1,3-alkadienes. By these methods, 1,3-nonadiene was polymerized using DEAB initiator to give an ester-telechelic polynonadiene. This was subsequently hydrogenated with copper chromite catalyst to give a hydroxyl terminated saturated liquid hydrocarbon prepolymer having greatly improved viscosity characteristics and a Tg 18 degrees lower than that of the hydrogenated polyisoprenes. The hydroxyl-telechelic saturated polymers prepared by the hydrogenolysis of ester-telechelic polyisoprene were reached with diisocyanates under conditions favoring linear chain extension gel permeation chromatography was used to monitor this condensation polymerization. Fractions having molecular weights above one million were produced.

Potts, J. E.↗

A survey of laser and selected optical systems for remote measurement of pollutant gas concentrations

Applications of the Differential Absorption Lidar (DIAL) technique to the remote sensing of pollutant gases are surveyed. In the DIAl technique, the differential absorption of two laser beams reflected back to a receiver from a target determines the concentration of the gas being studied. The types of instruments available are considered in detail: dye lidar (to measure nitrogen dioxide, sulfur dioxide, and ozone); carbon dioxide laser (for ozone, ethylene, ammonia, and hydrazine), helium-neon laser (for methane); hydrogen fluoride laser (for HF); and tunable diode laser (for nitric oxide and carbon monoxide). DIAL instruments are compared with other optical remote sensors such as Fourier-transform infrared spectrometers, correlation spectrometers (COSPEC and GASPEC), and grating spectrometers; and criteria for the selection of an appropriate gas measuring system are suggested. Laser and other optical remote sensors are found to be cost effective in many cases, despite the fact that they are more costly than point-monitoring systems.

Grant, W. B.↗

Ammonium and nitrate uptake by soybean during recovery from nitrogen deprivation

Soybean [Glycine max (L.) Merrill] plants that had been subjected to 15 d of nitrogen deprivation were resupplied for 10 d with 1.0 mol m-3 nitrogen provided as NO3-, NH4+, or NH4(+) + NO3- in flowing hydroponic culture. Plants in a fourth hydroponic system received 1.0 mol m-3 NO3- during both stress and resupply periods. Concentrations of soluble carbohydrates and organic acids in roots increased 210 and 370%, respectively, during stress. For the first day of resupply, however, specific uptake rates of nitrogen, determined by ion chromatography as depletion from solution, were lower for stressed than for non-stressed plants by 43% for NO3- resupply, by 32% for NH4(+) + NO3- resupply, and 86% for NH4+ resupply. When specific uptake of nitrogen for stressed plants recovered to rates for non-stressed plants at 6 to 8 d after nitrogen resupply, carbohydrates and organic acids in their roots had declined to concentrations lower than those of non-stressed plants. Recovery of nitrogen uptake capacity of roots thus does not appear to be regulated simply by the content of soluble carbon compounds within roots. Solution concentrations of NH4+ and NO3- were monitored at 62.5 min intervals during the first 3 d of resupply. Intermittent 'hourly' intervals of net influx and net efflux occurred. Rates of uptake during influx intervals were greater for the NH4(+)-resupplied than for the NO3(-)-resupplied plants. For NH4(+)-resupplied plants, however, the hourly intervals of efflux were more numerous than for NO3(-)-resupplied plants. It thus is possible that, instead of repressing NH4+ influx, increased accumulation of amino acids and NH4+ in NH4(+)-resupplied plants inhibited net uptake by stimulation of efflux on NH4+ absorbed in excess of availability of carbon skeletons for assimilation. Entry of NH4+ into root cytoplasm appeared to be less restricted than translocation of amino acids from the cytoplasm into the xylem.

NASA Discipline Number 61-10↗

An Unusual Coronal Mass Ejection: First Solar Wind Electron, Proton, Alpha Monitor (SWEPAM) Results from the Advanced Composition Explorer

This paper reports the first scientific results from the Solar Wind Electron Proton Alpha Monitor (SWEPAM) instrument on board the Advanced Composition Explorer (ACE) spacecraft. We analyzed a coronal mass ejection (CME) observed in the solar wind using data from early February, 1998. This event displayed several of the common signatures of CMEs, such as counterstreaming halo electrons and depressed ion and electron temperatures, as well as some unusual features. During a portion of the CME traversal, SWEPAM measured a very large helium to proton abundance ratio. Other heavy ions, with a set of ionization states consistent with normal (1 to 2x10(exp 6) K) coronal temperatures, were proportionately enhanced at this time. These observations suggest a source for at least some of the CME material, where heavy ions are initially concentrated relative to hydrogen and then accelerated up into the solar wind, independent of their mass and first ionization potential.

McComas, D. J.↗

Modeling of photodegradation in solar cell modules of substrate and superstrate design made with ethylene-vinyl acetate as pottant material

The rates of hydrogen abstraction by peroxy radicals were proven to be too slow for significant oxidation of the alkane substrate to be important. The numerical procedure, independent of our particular data base was verified by reproducing concentration time profiles for a model reaction set describing the cesium flare system in the upper atmosphere. Simulation was identical to that given in the literature. Experimental verification of the data base is to be attempted by weatherometry studies in the coming year. Work on the new diagnostic techniques was completed. The adapted automated viscometer was demonstrated to be an efficient and reliable tool for routine measurements of viscosity (molecular weight) changes in solid samples after batch solutions have been made up. The laser photolysis GC method for monitoring extremely low levels of oxidation in polymers proved to be impractical because the yields of carbon monoxide were too low for quantification. Much progress was made with the computer model. The reaction matrix was completely revised, resulting in a new scheme of 31 reactions and time, lifetimes in excess of ten years. The results to date lead us to some tentative observations.

Somersall, A. C.↗