Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High resolution X ray spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Science Goals of the Constellation-X Mission

The Constellation-X mission will address the questions: "What happens to matter close to a black hole?" and "What is Dark Energy?" These questions are central to the NASA Beyond Einstein Program, where Constellation-X plays a central role. The mission will address these questions by using high throughput X-ray spectroscopy to observe the effects of strong gravity close to the event horizon of black holes, and to observe the formation and evolution of clusters of galaxies in order to precisely determine Cosmological parameters. To achieve these primary science goals requires a factor of 25-100 increase in sensitivity for high resolution spectroscopy. The mission will also perform routine high- resolution X-ray spectroscopy of faint and extended X-ray source populations. This will provide diagnostic information such as density, elemental abundances, velocity, and ionization state for a wide range of astrophysical problems. This has enormous potential for the discovery of new unexpected phenomena. The Constellation-X mission is a high priority in the National Academy of Sciences McKee-Taylor Astronomy and Astrophysics Survey of new Astrophysics Facilities for the first decade of the 21st century.

White, Nicholas E.↗

Calibration of X-Ray Observatories

Accurate calibration of x-ray observatories has proved an elusive goal. Inaccuracies and inconsistencies amongst on-ground measurements, differences between on-ground and in-space performance, in-space performance changes, and the absence of cosmic calibration standards whose physics we truly understand have precluded absolute calibration better than several percent and relative spectral calibration better than a few percent. The philosophy "the model is the calibration" relies upon a complete high-fidelity model of performance and an accurate verification and calibration of this model. As high-resolution x-ray spectroscopy begins to play a more important role in astrophysics, additional issues in accurately calibrating at high spectral resolution become more evident. Here we review the challenges of accurately calibrating the absolute and relative response of x-ray observatories. On-ground x-ray testing by itself is unlikely to achieve a high-accuracy calibration of in-space performance, especially when the performance changes with time. Nonetheless, it remains an essential tool in verifying functionality and in characterizing and verifying the performance model. In the absence of verified cosmic calibration sources, we also discuss the notion of an artificial, in-space x-ray calibration standard. 6th

Weisskopf, Martin C.↗

Advances toward high spectral resolution quantum X-ray calorimetry

Thermal detectors for X-ray spectroscopy combining high spectral resolution and quantum efficiency have been developed. These microcalorimeters measure the energy released in the absorption of a single photon by sensing the rise in temperature of a small absorbing structure. The ultimate energy resolution of such a device is limited by the thermodynamic power fluctuations in the thermal link between the calorimeter and isothermal bath and can in principle be made as low as 1 eV. The performance of a real device is degraded due to noise contributions such as excess 1/f noise in the thermistor and incomplete conversion of energy into phonons. The authors report some recent advances in thermometry, X-ray absorption and thermalization, fabrication techniques, and detector optimization in the presence of noise. These improvements have resulted in a device with a spectral resolution of 17 eV FWHM, measured at 6 keV.

Moseley, S. H.↗

High resolution X- and gamma-ray spectroscopy of solar flares

A balloon-borne X- and gamma-ray instrument was developed, fabricated, and flown. This instrument has the highest energy resolution of any instrument flown to date for measurements of solar and cosmic X-ray and gamma-ray emission in the 13 to 600 keV energy range. The purpose of the solar measurements was to study electron acceleration and solar flare energy release processes. The cosmic observations were to search for cyclotron line features from neutron stars and for low energy gamma-ray lines from nucleosynthesis. The instrument consists of four 4 cm diameter, 1.3 cm thick, planar intrinsic germanium detectors cooled by liquid nitrogen and surrounded by CsI and NaI anti-coincidence scintillation crystals. A graded z collimator limited the field of view to 3 deg x 6 deg and a gondola pointing system provided 0.3 deg pointing accuracy. A total of four flights were made with this instrument. Additional funding was obtained from NSF for the last three flights, which had primarily solar objectives. A detailed instrument description is given. The main scientific results and the data analysis are discussed. Current work and indications for future work are summarized. A bibliography of publications resulting from this work is given.

Lin, R. P.↗

The XRISM Science Data Center: Optimizing the Scientific Return from a Unique X-ray Observatory

The X-Ray Imaging and Spectroscopy Mission, XRISM, is currently scheduled to launch in 2022 with the objective of building on the brief, but significant, successes of the ASTRO-H (Hitomi) mission in solving outstanding astrophysical questions using high resolution X-ray spectroscopy. The XRISM Science Operations Team (SOT) consists of the JAXA-led Science Operations Center (SOC) and NASA-led Science Data Center (SDC), which work together to optimize the scientific output from the Resolve high-resolution spectrometer and the Xtend wide-field imager through planning and scheduling of observations, processing and distribution of data, development and distribution of software tools and the calibration database (CaldB), support of ground and in-flight calibration, and support of XRISM users in their scientific investigations of the energetic universe. Here, we summarize the roles and responsibilities of the SDC and its current status and future plans. The Resolve instrument poses particular challenges due to its unprecedented combination of high spectral resolution and throughput, broad spectral coverage, and relatively small field-of-view and large pixel-size. We highlight those challenges and how they are being met.

XRISM↗

Probing Sulfur Chemical and Electronic Structure with Experimental Observation and Quantitative Theoretical Prediction of Kα and Valence-to-Core Kβ X-ray Emission Spectroscopy

An extensive experimental and theoretical study of the Kα and Kβ high-resolution X-ray emission spectroscopy (XES) of sulfur-bearing systems is presented here. This study encompasses a wide range of organic and inorganic compounds, including numerous experimental spectra from both prior published work and new measurements. Employing a linear-response time-dependent density functional theory (LR-TDDFT) approach, strong quantitative agreement is found in the calculation of energy shifts of the core-to-core Kα as well as the full range of spectral features in the valence-to-core Kβ spectrum. The ability to accurately calculate the sulfur Kα energy shift supports the use of sulfur Kα XES as a bulk-sensitive tool for assessing sulfur speciation. The fine structure of the sulfur Kβ spectrum, in conjunction with the theoretical results, is shown to be sensitive to the local electronic structure including effects of symmetry, ligand type and number, and, in the case of organosulfur compounds, to the nature of the bonded organic moiety. This agreement between theory and experiment, augmented by the potential for high-access XES measurements with the latest generation of laboratory-based spectrometers, demonstrates the possibility of broad analytical use of XES for sulfur and nearby third-row elements. The effective solution of the forward problem, i.e., successful prediction of detailed spectra from known molecular structure, also suggests future use of supervised machine learning approaches to experimental inference, as has seen recent interest for interpretation of X-ray absorption near-edge structure (XANES).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The MIT spectroscopy investigations on AXAF and the study of supernova remnants

The MIT High Resolution X-Ray Spectroscopy experiment on the AXAF, which will study physical conditions in celestial sources by means of detailed measurements of emission and absorption features in their spectra, involves two complementary dispersive instruments: Bragg Crystal Spectrometer (BCS) and High Energy Transmission Grating (HETG). This paper discusses the principles of operation of BCS and HETG and the results that will be obtained by these instruments. Measurements of individual line strengths obtained by the AXAF spectrometers will allow the application of plasma diagnostic techniques to a study of the detailed physical conditions in celestial objects, particularly in the optically thin plasma of supernova remnants, which is particularly well suited to the application of plasma diagnostics.

Canizares, C. R.↗

X-Ray Calorimeter Arrays for Astrophysics

High-resolution x-ray spectroscopy is a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites started a new era in x-ray astronomy, but there remains a need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band (around 6 keV) and can enable imaging spectroscopy of extended sources, such as supernova remnants and galaxy clusters. The instrumentation needed is a broad-band imaging spectrometer - basically an x-ray camera that can distinguish tens of thousands of x-ray colors. The potential benefits to astrophysics of using a low-temperature calorimeter to determine the energy of an incident x-ray photon via measurement of a small change in temperature was first articulated by S. H. Moseley over two decades ago. In the time since, technological progress has been steady, though full realization in an orbiting x-ray telescope is still awaited. A low-temperature calorimeter can be characterized by the type of thermometer it uses, and three types presently dominate the field. The first two types are temperature-sensitive resistors - semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a paramagnetic thermometer. These types can be considered the three generations of x-ray calorimeters; by now each has demonstrated a resolving power of 2000 at 6 keV, but only a semiconductor calorimeter system has been developed to spaceflight readiness. The Soft X-ray Spectrometer on Astro-H, expected to launch in 2013, will use an array of silicon thermistors with I-IgTe x-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays, kilo-pixel arrays of the superconducting calorimeters are just now being produced, and it is anticipated that much larger arrays will require the non-dissipative advantage of magnetic thermometers.

Kilbourne, Caroline A.↗

High-resolution spectroscopy of the optical candidate for the X-ray transient X0331 + 53

High-resolution spectral observations of the optical candidate for the X-ray transient X0331 + 53 are presented. The data show broad hydrogen and helium emission and strong interstellar absorption corresponding to a visual extinction of about 7 mag. No photospheric absorption in the emission lines, and no radial-velocity variations greater than 0.5 km/s were found over a three-day period. It is concluded that the optical continuum does not arise at or near the primary star. As an example of the spectrographic data, a resolution profile of H-alpha emission in X0331 + 53 is provided.

Stocke, J.↗

Development of “GaSb-on-silicon” metamorphic substrates for optoelectronic device growth

The epitaxial development and characterization of metamorphic “GaSb-on-silicon” buffers as substrates for antimonide devices is presented. The approach involves the growth of a spontaneously and fully relaxed GaSb metamorphic buffer in a primary epitaxial reactor, and use of the resulting “GaSb-on-silicon” wafer to grow subsequent layers in a secondary epitaxial reactor. The buffer growth involves four steps—silicon substrate preparation for oxide removal, nucleation of AlSb on silicon, growth of the GaSb buffer, and finally capping of the buffer to prevent oxidation. This approach on miscut silicon substrates leads to a buffer with negligible antiphase domain density. The growth of this buffer is based on inducing interfacial misfit dislocations between an AlSb nucleation layer and the underlying silicon substrate, which results in a fully relaxed GaSb buffer. A 1 μm thick GaSb layer buffer grown on silicon has ~9.2 × 10 7 dislocations/cm 2 . The complete lack of strain in the epitaxial structure allows subsequent growths to be accurately lattice matched, thus making the approach ideal for use as a substrate. Here we characterize the GaSb-on-silicon wafer using high-resolution x-ray diffraction and transmission electron microscopy. The concept’s feasibility is demonstrated by growing interband cascade light emitting devices on the GaSb-on-silicon wafer. The performance of the resulting LEDs on silicon approaches that of counterparts grown lattice matched on GaSb.

36 MATERIALS SCIENCE↗

New Worlds / New Horizons Science with an X-ray Astrophysics Probe

In 2013 NASA commenced a design study for an X-ray Astrophysics Probe to address the X-ray science goals and program prioritizations of the Decadal Survey New World New Horizons (NWNH) with a cost cap of approximately $1B. Both the NWNH report and 2011 NASA X-ray mission concept study found that high-resolution X-ray spectroscopy performed with an X-ray microcalorimeter would enable the most highly rated NWNH X-ray science. Here we highlight some potential science topics, namely: 1) a direct, strong-field test of General Relativity via the study of accretion onto black holes through relativistic broadened Fe lines and their reverberation in response to changing hard X-ray continuum, 2) understanding the evolution of galaxies and clusters by mapping temperatures, abundances and dynamics in hot gas, 3) revealing the physics of accretion onto stellar-mass black holes from companion stars and the equation of state of neutron stars through timing studies and time-resolved spectroscopy of X-ray binaries and 4) feedback from AGN and star formation shown in galaxy-scale winds and jets. In addition to these high-priority goals, an X-ray astrophysics probe would be a general-purpose observatory that will result in invaluable data for other NWNH topics such as stellar astrophysics, protostars and their impact on protoplanetary systems, X-ray spectroscopy of transient phenomena such as high-z gamma-ray bursts and tidal capture of stars by massive black holes, and searches for dark matter decay.

Smith, Randall K.↗

Metal ion dopant-induced famatinite to chalcostibite phase transformation of copper antimony sulphide colloidal nanostructures: effect on photophysical and pseudocapacitance properties

Here, the strategic doping of transition metal ions into copper antimony sulphide (CAS) semiconducting nanostructures can significantly influence their photophysical and pseudocapacitive properties, for which there are few reports and therefore is the focus of this study. Accordingly, highly crystalline metal ion (Mn 2+ , Fe 2+ , Co 2+ , Ni 2+ and Zn 2+ ) doped off-stoichiometric copper rich/poor, antimony-rich/poor, and sulphur-poor CAS nanostructures (10–23 nm) were grown via colloidal (hot-injection) synthesis using metal diethyldithiocarbamate precursors. Importantly, metal ion doping significantly influences the structure and composition of the off-stoichiometric CAS nanostructures. Data from powder X-ray diffraction, Raman spectroscopy, high-resolution scanning/transmission electron microscopy, and energy dispersive X-ray spectroscopy confirm that the heavier metal ion dopants induce a novel phase transformation from famatinite (fCAS) to chalcostibite (cCAS) nanostructures. The influence of the metal ion dopants is also observed in the optical properties of as-synthesized nanostructures. This involves blue-shifted ultraviolet-visible absorption, reduced Urbach tailing, and tunable bandgaps between 2.17 and 2.38 eV. Also, the doped nanostructures display broad visible-near infrared photoluminescence via a triple radiative pathway with relatively short decay lifetimes between 0.2 and 6.1 ns. This is mediated by electronic transitions involving intrinsic (copper/antimony/sulphur interstitial) and extrinsic (metal ion interstitial) defect states. Additionally, electrodes prepared from Mn 2+ -doped fCAS nanostructures show enhanced pseudocapacitance via Na+ surface adsorption and intercalation relative to undoped fCAS electrodes, while Zn 2+ -doped cCAS electrodes exhibit pseudocapacitance via a combination of Na+ surface adsorption, intercalation, and redox reactions. These electrodes exhibit reduced charge transfer resistance, improved electronic conductivity and notably enhanced specific capacitance (∼222 F g −1 ), and charge transport, as measured in 1 M Na 2 SO 4 electrolyte via cyclic voltammetry and electrochemical impedance spectroscopy. To this end, the discovery of the metal ion-induced phase transformation presents a new avenue for optimizing the functional properties of fCAS and cCAS nanostructures, highlighting the critical role of metal ion-related defects in controlling the optical and electrochemical properties, towards potential solar absorption and energy storage applications.

25 ENERGY STORAGE↗

High Temperature Superconductor Lead Assemblies for XRISM

The RESOLVE instrument on the upcoming XRISM mission is a rebuild of the SXS instrument that successfully demonstrated high resolution X-ray spectroscopy on the Hitomi mission using a microcalorimeter array at 50 mK. As with SXS, the RESOLVE instrument requires High Temperature Superconductor (HTS) lead assemblies to carry high current to the Adiabatic Demagnetization Refrigerator (ADR) while meeting a very stringent heat conductance budget. For the RESOLVE HTS lead assemblies, we have used new materials and processes to improve the stability and consistency of solder joints to the HTS material. We have also designed a new thermal strap that eliminates stress concentrations on the HTS tapes. We present the results of testing on the engineering model and flight model units, as well as the results of long term testing on prototype solder joints.

Canavan, Edgar R.↗

Lynx X-Ray Microcalorimeter Cryogenic System

The Lynx x-ray microcalorimeter instrument on the Lynx X-ray Observatory requires a state-of-the-art cryogenic system to enable high-precision and high-resolution x-ray spectroscopy. The cryogenic system and components described provide the required environment using cooling technologies that are already at relatively high technology readiness levels and are progressing toward flight-compatible subsystems. These subsystems comprise a cryostat, a 4.5-K mechanical cryocooler, and an adiabatic demagnetization refrigerator that provides substantial cooling power at 50 mK.

DiPirro, Michael↗

The XRISM first-light observation: Velocity structure and thermal properties of the supernova remnant N 132D

Abstract We present an initial analysis of the X-Ray Imaging and Spectroscopy Mission (XRISM) first-light observation of the supernova remnant (SNR) N 132D in the Large Magellanic Cloud. The Resolve microcalorimeter has obtained the first high-resolution spectrum in the 1.6–10 keV band, which contains K-shell emission lines of Si, S, Ar, Ca, and Fe. We find that the Si and S lines are relatively narrow, with a broadening represented by a Gaussian-like velocity dispersion of $\sigma _v \sim 450$ km s$^{-1}$. However, the Fe He$\alpha$ lines are substantially broadened with $\sigma _v \sim 1670$ km s$^{-1}$. This broadening can be explained by a combination of the thermal Doppler effect due to the high ion temperature and the kinematic Doppler effect due to the SNR expansion. Assuming that the Fe He$\alpha$ emission originates predominantly from the supernova ejecta, we estimate the reverse shock velocity at the time when the bulk of the Fe ejecta were shock heated to be $-1000 \lesssim V_{\rm rs}$ (km s$^{-1}$) $\lesssim 3300$ (in the observer frame). We also find that Fe Ly$\alpha$ emission is redshifted with a bulk velocity of $\sim 890$ km s$^{-1}$, substantially larger than the radial velocity of the local interstellar medium surrounding N 132D. These results demonstrate that high-resolution X-ray spectroscopy is capable of providing constraints on the evolutionary stage, geometry, and velocity distribution of SNRs.

individual objects↗

The high energy transmission grating spectrometer for AXAF

Attention is given to a high energy transmission grating spectrometer that operates over the range 0.4-8 keV, giving resolving powers of 100-1000 and effective areas of 10-200 sq cm. The instrument, which is part of the MIT high resolution X-ray spectroscopy investigation, consists of a single array of grating facets of two types: medium energy gratings of 0.6-micron period, 0.5-micron thick silver mounted behind the outer three AXAF mirrors, and high energy gratings of 0.2-micron period, 1.0-micron thick gold mounted behind the inner three mirrors. The gratings are oriented so as to correct for coma and so that the medium and high energy spectra form a shallow 'X' at the AXAF focal plane. Likely targets include normal stars, binary X-ray sources, active galactic nuclei and quasars. The HETGS can also be used to give moderate resolution spectra of slightly extended sources and monochromatic images of sources with strong lines, such as supernova remnants in nearby galaxies.

Canizares, C. R.↗

The Athena/X-IFU, from Detector Development to Scientific Feasibility Studies via Simulations

The investigation of the physical hot and energetic phenomena in the Universe will further improve our understanding of the assembly of the largest structures and massive halos of galaxies, and of the role of black holes in shaping the Universe as we see it. Spatially resolved X-ray high-resolution spectroscopy will be a crucial tool to achieve these scientific goals. The X-IFU instrument onboard the Athena observatory will provide us with these capabilities through the use of arrays of Transition edge microcalorimeters detectors. These superconducting devices will deliver the required exquisite spectral resolution needed to achieve the core science objectives, such as the characterization of turbulence and bulk motions in the hot gaseous atmospheres of groups and clusters of galaxies in order to unveil the process of large scale structures assembly. I will present the Transition Edge Sensors principle, the status of the instrumental development for the X-IFU instrument, and discuss their performance in view of the scientific objectives of the Athena mission. I will further present the case of a feasibility study and optimisation of the observing strategy for the characterization of the internal dynamics of the intra-cluster medium, through the use of mock simulations of observations with the X-IFU instrument.

Sophie Beaumont↗

The Astro-H High Resolution Soft X-Ray Spectrometer

We present the overall design and performance of the Astro-H (Hitomi) Soft X-Ray Spectrometer (SXS). The instrument uses a 36-pixel array of x-ray microcalorimeters at the focus of a grazing-incidence x-ray mirror Soft X-Ray Telescope (SXT) for high-resolution spectroscopy of celestial x-ray sources. The instrument was designed to achieve an energy resolution better than 7 eV over the 0.3-12 keV energy range and operate for more than 3 years in orbit. The actual energy resolution of the instrument is 4-5 eV as demonstrated during extensive ground testing prior to launch and in orbit. The measured mass flow rate of the liquid helium cryogen and initial fill level at launch predict a lifetime of more than 4 years assuming steady mechanical cooler performance. Cryogen-free operation was successfully demonstrated prior to launch. The successful operation of the SXS in orbit, including the first observations of the velocity structure of the Perseus cluster of galaxies, demonstrates the viability and power of this technology as a tool for astrophysics.

spectrometers↗