Data-Driven Probabilistic Voltage Risk Assessment of MiniWECC System with Uncertain PVs and Wind Generations using Realistic Data

Here, it is found from actual data that due to generation dispatch and uncertain renewable generations and loads with complicated correlations, inferring the probabilistic distributions for uncertain inputs is challenging. Many probabilistic power flow approaches have been developed in the literature but their validations using realistic systems and data are lacking. This paper proposes a data-driven probabilistic analysis approach for system risk assessment of the miniWECC system using actual data. The sparse Gaussian process (SGP) is advocated to quantify the impacts of uncertain inputs on voltage security. SGP does not need the probability distribution function of uncertain inputs, can handle correlations and is highly computationally efficient. Results on the miniWECC system using realistic data show that SGP outperforms existing approaches and is able to quantify the voltage violation risks.

17 WIND ENERGY↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters: Preprint

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Auto Recycler Report: Results from a Questionnaire about Processing Electric Vehicles and Handling High-Voltage Batteries

With the transition to clean energy the demand for electric vehicles in the United States is rapidly growing. As demand continues to rise in the next couple of decades, sourcing materials (e.g., lithium, nickel, cobalt, graphite, etc.) to put into new batteries for electric vehicles will be critical. The U.S. does not have significant reserves of most of these materials and relies heavily on foreign countries. The lithium-ion batteries in electric vehicles are large and contain substantial amounts of critical materials, therefore, they are a promising source of materials for new batteries. Recycling electric vehicle batteries when they reach their end-of-life will enable the United States to generate a domestic supply of materials needed for future batteries. [1-3] The auto recycling industry is the largest collective owner of end-of-life vehicles in the U.S. and will be the primary handlers of battery-powered vehicles (i.e., hybrid or electric) when they reach the end of their useful life. In an effort to better understand how the auto recycling industry currently handles battery-powered vehicles and their high-voltage batteries, DOE’s ReCell Center for Advanced Battery Recycling (ReCell) developed a questionnaire and distributed it to various trade organizations in the automotive recycling industry.

25 ENERGY STORAGE↗

Time-resolved ion energy distribution functions during a HiPIMS discharge with cathode voltage reversal

Abstract The effect on the ion energy distribution function (IEDF) of plasma produced during a high-power impulse magnetron sputtering (HiPIMS) discharge as the pulse conditions are varied is reported. Pressure was varied from 0.67–2.00 Pa (5–15 mTorr), positive kick pulses up to 200 V tested with a constant 4 μ s delay between negative and positive cycles. The results demonstrate that the resulting plasma during the positive cathode voltage reversal is the result of expansion through the largely neutral gas species between the end of the magnetic trap of the target and the workpiece. The plasma potential rises on similar time scale with the evolution of a narrow peak in the IEDF close to the applied bias. The peak of the distribution function remains narrow close to the applied bias irrespective of pulse length, and with only slight pressure dependence. One exception discovered is that the IEDF contains a broad high energy tail early in the kick pulse due to acceleration of ions present beyond the trap from the main pulse separate from the ionization front that follows.

Physics↗

Analysis of Conservation Voltage Reduction under Inverter-Based VAR-Support [Slides]

Conservation voltage reduction (CVR) is a common technique used by utilities to strategically reduce demand during peak periods. As penetration levels of distributed generation (DG) continue to rise and advanced inverter capabilities become more common, it is unclear how the effectiveness of CVR will be impacted and how CVR interacts with advanced inverter functions. In this work, we investigated the mutual impacts of CVR and DG from photovoltaic (PV) systems (with and without autonomous Volt-VAR enabled). The analysis was conducted on an actual utility dataset, including a feeder model, measurement data from smart meters and intelligent reclosers, and metadata for more than 30 CVR events triggered by the utility over the year. The installed capacity of the modeled PV systems represented 66% of peak load, but reached instantaneous penetrations reached up to 2.5x the load consumption over the year. While the objectives of CVR and autonomous Volt-VAR are opposed to one another, this study found that their interactions were mostly inconsequential since the CVR events occurred when total PV output was low.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MgZnO High‐Voltage Transparent Thin‐Film Transistors Built on Glass

Recently, there has been increasing interest in building‐integrated photovoltaic (BIPV), which enables harvesting solar energy effectively. Large‐area glass components such as windows are widely used in modern constructions. In addition to the PV on opaque components such as walls and roofs, the transparent photovoltaic (TPV) directly built on glass is complementary to fully utilize the PV energy in BIPV. A high‐voltage transparent thin‐film transistor (HVTTFT) built on glass is an ideal option for distributed microinverters for TPV modules. A wide‐bandgap oxide‐based HVTTFT on glass for this purpose is reported. The HVTTFT on glass uses ZnO‐based materials with different functions for two roles: a semiconductor Mg 0.01 Zn 0.99 O (MZO) as TFT channel and Al‐doped ZnO (AZO) as transparent conductive oxide (TCO) electrodes. The centrosymmetric circular structure of the MZO HVTTFT with a high‐k‐stacking gate dielectric enables a blocking voltage as high as ≈1 kV and an on/off ratio of 10 6 . The device exhibits an average optical transmittance of 81% over the visible spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implementing hydrogen oxidation reaction on Pt for controlling counter electrode processes

The search for active, stable, and durable materials for electrochemical energy technologies requires increasing levels of precision to establish true structure-function relationships and guide materials design from atomic and molecular scale. This increases the level of control required over the experimental system for proper materials evaluation. The choice of counter electrode material become crucial, as Pt dissolution at high voltages may cause contamination to the working electrode, especially when studying reductive processes in reactions such as oxygen reduction reaction (ORR), H 2 evolution reaction (HER), and the CO 2 reduction reaction. The learnings from “old school” electrochemistry groups lead us to leverage H 2 reactions over Pt to construct a counter electrode system with controlled potential that eliminates Pt ion contamination concerns. In here we discuss the construction of such Pt|H 2 counter electrode where key experimental aspects such as the H 2 flow rate and effective distribution determines the maximum current this counter electrode can accommodate before switching to high voltage and triggering Pt dissolution. Lastly, we demonstrate the use of the Pt|H 2 counter electrode in aqueous electrolytes during HER occurring on the working electrode at varying currents, showing that the Pt content in the cell remains below parts per trillion (ppt) up to 10 mA, and below 50 ppt at 100 mA up to 1 h of constant current hold. This work provides a guide to the implementation of Pt|H 2 counter electrodes to improve the precision of electrochemical experiments in search of highly active, selective, and durable materials for energy technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EVs@Scale Lab Consortium High-Power Charging Pillar Deep-Dive Technical Meeting

Managed under the the U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, the High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to create an experimental platform for integration and control approaches in a direct current (DC), distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for a DC-coupled charging hub ("DC hub" for short). This report explains the design, development, and implementation process of an experimental platform for the DC hub. DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges in establishing a DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and a lack of common system-level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products, as well as novel, in-house designed solutions, to evaluate different use cases at rated power and voltage levels. The developed proof-of-concept charging platform and open-source SEMS allow the development and testing of various controllers and chargers from different vendors. The DC hub platform integrated EVs, an ESS, a PV system, and building load to demonstrate the flexibility of the platform. The open-source SEMS controlled the devices within the hub using a rule-based implementation, realizing available standards.

ADVANCED PROPULSION SYSTEMS↗

Time-resolved electron energy distribution functions at the substrate during a HiPIMS discharge with cathode voltage reversal

Abstract The time-dependent plasma properties of a high-power impulse magnetron sputtering plasma are investigated which include a positive ‘kick’ pulse on the sputtering target 2 μ s after the main negative pulse, this reversing the voltage on the cathode. At a substrate 15 cm distant from the magnetron, the time-dependent electron energy distribution function (EEDF), plasma potential, potential commute time and plasma diffusion properties are measured using a single Langmuir probe. Results show that the positive pulse on the target expels plasma and raises the plasma potential across the chamber on the order of 1 to 2 μ s, which is the time scale of the electron diffusion. The EEDF at the substrate fits a Druyvesteyn distribution during the main negative pulse rising slightly in average energy over time. The distribution is still Druyvesteyn and at the very start of the positive pulse, but then loses the higher energy electrons and drops in average electron energy as the positive pulse progresses. A Boltzmann equation solver, BOLSIG+, was used to predict the EEDF at the substrate during the positive pulse and it agrees best with the measurements assuming a value of 0.2 Td for the E / N (electric field/gas number density).

Physics↗

Kinetic simulations of ignited mode cesium vapor thermionic converters

Cesium vapor thermionic converters are an attractive method of converting high-temperature heat directly to electricity, but theoretical descriptions of the systems have been difficult due to the multi-step ionization of Cs through inelastic electron–neutral collisions. This work presents particle-in-cell simulations of these converters, using a direct simulation Monte Carlo collision model to track 52 excited states of Cs. Here, these simulations show the dominant role of multi-step ionization, which also varies significantly based on both the applied voltage bias and pressure. The electron energy distribution functions are shown to be highly non-Maxwellian in the cases analyzed here. A comparison with previous approaches is presented, and large differences are found in ionization rates due especially to the fact that previous approaches have assumed Maxwellian electron distributions. Finally, an open question regarding the nature of the plasma sheaths in the obstructed regime is discussed. The one-dimensional simulations did not produce stable obstructed regime operation and thereby do not support the double-sheath hypothesis.

30 DIRECT ENERGY CONVERSION↗

Voltage Estimation in Low-Voltage Distribution Grids with Distributed Energy Resources

Present distribution grids generally have limited sensing capabilities and are therefore characterized by low observability. Improved observability is a prerequisite for increasing the hosting capacity of distributed energy resources such as solar photovoltaics (PV) in distribution grids. In this context, this paper presents learning-aided low-voltage estimation using untapped but readily available and widely distributed sensors from cable television (CATV) networks. The cable broadband sensors offer timely local voltage magnitude sensing with 5-minute resolution and can provide an order of magnitude more data on the time-varying state of a secondary distribution system than currently deployed utility sensors. The proposed solution incorporates voltage readings from neighboring CATV sensors, taking into account spatio-temporal aspects of the observations, and estimates single-phase voltage magnitudes at all non-monitored low-voltage buses using random forests. The effectiveness of the proposed approach was demonstrated using a multi-phase 1572-bus feeder from the SMART-DS data set for two case studies passive distribution feeder (without PV) and active distribution feeder (with PV). The analysis was conducted on simulated data, and the results show voltage estimates with a high degree of accuracy, even at extremely low percentages of observable nodes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Role of Metal Substitution in Tuning Anion Redox in Sodium Metal Layered Oxides Revealed by X‐Ray Spectroscopy and Theory

Abstract We investigate high‐valent oxygen redox in the positive Na‐ion electrode P2‐Na 0.67− x [Fe 0.5 Mn 0.5 ]O 2 (NMF) where Fe is partially substituted with Cu (P2‐Na 0.67− x [Mn 0.66 Fe 0.20 Cu 0.14 ]O 2 , NMFC) or Ni (P2‐Na 0.67− x [Mn 0.65 Fe 0.20 Ni 0.15 ]O 2 , NMFN). From combined analysis of resonant inelastic X‐ray scattering and X‐ray near‐edge structure with electrochemical voltage hysteresis and X‐ray pair distribution function profiles, we correlate structural disorder with high‐valent oxygen redox and its improvement by Ni or Cu substitution. Density of states calculations elaborate considerable anionic redox in NMF and NMFC without the widely accepted requirement of an A‐O‐A′ local configuration in the pristine materials (where A=Na and A′=Li, Mg, vacancy, etc.). We also show that the Jahn–Teller nature of Fe 4+ and the stabilization mechanism of anionic redox could determine the extent of structural disorder in the materials. These findings shed light on the design principles in TM and anion redox for positive electrodes to improve the performance of Na‐ion batteries.

Abate, Iwnetim↗

Performance Evaluation of Peer-to-Peer Distributed Microgrids Coordination for Voltage Regulation

This paper presents the performance evaluation of a peer-to-peer microgrids coordination algorithm for sub-transmission systems. As distributed energy resources (DERs) in distribution system start to show negative impact to the bulk power system, a paradigm shift is needed for transmission planning and operation. Because distribution substations are located far from the sub-transmission system, and it is hard to use traditional centralized control for real-time control and coordination. Thus, distributed control is a natural choice because it requires less communication and central computation. In this paper, each distribution substation is treated as a microgrid, and the peer-to-peer distributed microgrids control is formulated as a real-time optimal power flow problem to reduce the negative impact in sub-transmission systems. A distributed primal-dual optimization algorithm is adopted to solve the problem. Validation of the peer-to-peer algorithm is performed through the simulation of a real-world sub-transmission system composing of many distribution systems with high renewable penetration. Simulation results show that the peer-to-peer algorithm can achieve satisfactory performance (e.g., voltage regulation) in sub-transmission system by coordinating and controlling DERs in distribution systems.

distributed control↗

Performance Evaluation of Peer-to-Peer Distributed Microgrids Coordination for Voltage Regulation: Preprint

This paper presents the performance evaluation of a peer-to-peer microgrids coordination algorithm for sub-transmission systems. As distributed energy resources (DERs) in distribution system start to show negative impact to the bulk power system, a paradigm shift is needed for transmission planning and operation. Because distribution substations are located far from the sub-transmission system, and it is hard to use traditional centralized control for real-time control and coordination. Thus, distributed control is a natural choice because it requires less communication and central computation. In this paper, each distribution substation is treated as a microgrid, and the peer-to-peer distributed microgrids control is formulated as a real-time optimal power flow problem to reduce the negative impact in sub-transmission systems. A distributed primal-dual optimization algorithm is adopted to solve the problem. Validation of the peer-to-peer algorithm is performed through the simulation of a real-world sub-transmission system composing of many distribution systems with high renewable penetration. Simulation results show that the peer-to-peer algorithm can achieve satisfactory performance (e.g., voltage regulation) in sub-transmission system by coordinating and controlling DERs in distribution systems.

distributed control↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation

As modern power systems are experiencing exceptional changes with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system could obtain high system resilience by not relying on the bulk power system restoration, which requires significant human intervention and procedure. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and the technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by- phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and startup behaviors as well as network dynamics. In addition, active involvement of grid- following distributed energy resources is also studied to facilitate the black-start process. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, we demonstrate that a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start, using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.