At least 73 records · Page 4

Studies of basic mechanisms occurring in high pressure gases: Applications to high efficiency high power lasers

The atomic fluorine laser was investigated. In the hollow cathode, lasing on Fluorine transitions in the doublet system lasted for up to 80 microns with no signs of self-termination. The excitation process of the laser appears to depend heavily upon the fluorine donor utilized. For instance, a single step process is involved when NF3 is used whereas a two step process is evident for SF6. The details are discussed.

Crane, J. K., III↗

Hydrogen at high pressure

Results of recent studies of the high-pressure states of hydrogen using diamond anvils are summarized. Problems associated with the study of hydrogen under megabar pressures are briefly examined. Attention is then given to new data on the physical state of solid hydrogen, the 1.5-megabar phase transition, changes in the electronic configuration of hydrogen at high pressure, and directions of further research on the high-pressure phases of hydrogen.

Mao, Ho-Kwang↗

High-pressure cryogenic seals for pressure vessels

This investigation of the problems associated with reliably containing gaseous helium pressurized to 1530 bars (22 500 psi) between 4.2 K and 150 K led to the following conclusions: (1) common seal designs used in existing elevated-temperature pressure vessels are unsuitable for high-pressure cryogenic operation, (2) extrusion seal-ring materials such as Teflon, tin, and lead are not good seal materials for cryogenic high-pressure operation; and (3) several high-pressure cryogenic seal systems suitable for large-pressure vessel applications were developed; two seals required prepressurization, and one seal functioned repeatedly without any prepressurization. These designs used indium seal rings, brass or 304 stainless-steel anvil rings, and two O-rings of silicone rubber or Kel-F.

Buggele, A. E.↗

Cryogenic Transport of High-Pressure-System Recharge Gas

A method of relatively safe, compact, efficient recharging of a high-pressure room-temperature gas supply has been proposed. In this method, the gas would be liquefied at the source for transport as a cryogenic fluid at or slightly above atmospheric pressure. Upon reaching the destination, a simple heating/expansion process would be used to (1) convert the transported cryogenic fluid to the room-temperature, high-pressure gaseous form in which it is intended to be utilized and (2) transfer the resulting gas to the storage tank of the system to be recharged. In conventional practice for recharging high-pressure-gas systems, gases are transported at room temperature in high-pressure tanks. For recharging a given system to a specified pressure, a transport tank must contain the recharge gas at a much higher pressure. At the destination, the transport tank is connected to the system storage tank to be recharged, and the pressures in the transport tank and the system storage tank are allowed to equalize. One major disadvantage of the conventional approach is that the high transport pressure poses a hazard. Another disadvantage is the waste of a significant amount of recharge gas. Because the transport tank is disconnected from the system storage tank when it is at the specified system recharge pressure, the transport tank still contains a significant amount of recharge gas (typically on the order of half of the amount transported) that cannot be used. In the proposed method, the cryogenic fluid would be transported in a suitably thermally insulated tank that would be capable of withstanding the recharge pressure of the destination tank. The tank would be equipped with quick-disconnect fluid-transfer fittings and with a low-power electric heater (which would not be used during transport). In preparation for transport, a relief valve would be attached via one of the quick-disconnect fittings (see figure). During transport, the interior of the tank would be kept at a near-ambient pressure far below the recharge pressure. As leakage of heat into the tank caused vaporization of the cryogenic fluid, the resulting gas would be vented through the relief valve, which would be set to maintain the pressure in the tank at the transport value. Inasmuch as the density of a cryogenic fluid at atmospheric pressure greatly exceeds that of the corresponding gas in a practical high-pressure tank at room temperature, a tank for transporting a given mass of gas according to the proposed method could be smaller (and, hence, less massive) than is a tank needed for transporting the same mass of gas according to the conventional method.

Ungar, Eugene K,↗

Development of high pressure gas systems

This paper presents a report on the latest advances and technology in the design, construction, testing, and operation of high pressure gas bimetallic pipe systems and high pressure gas tube fittings facilitating greater alinement and manufacturing tolerances, and the supercleaning of high pressure gas systems under field conditions. The following specific topics are discussed: - Analysis of noncorrosive steels versus bimetallic, high strength steels - Analysis of various protective finishes versus bimetallic piping - Testing of high pressure systems - Pipe liner adhesion properties under varying operating conditions - Modified flared tube fittings taking into account pressure ranges, materials, costs involved in manufacture, various methods employed to permit sealing of the fitting while meeting cleanliness requirements - Cleaning requirements appertaining to high pressure gas systems and a discussion of investigations on the effects of velocity and temperature as related to various cleaning chemicals. The presentation concludes with a discussion on the possible applications of materials and methods in commercial industry.

Fitting↗

Fuel droplet burning rates at high pressures

Combustion of methanol, ethanol, propanol -1, n - pentane, n - heptane and n - decane was observed in air under natural convection conditions at pressures up to 100 atm. The droplets were simulated by porous spheres with diameters in the range 0.63 - 1.90 cm. The pressure levels of the tests were high enough so that near critical combustion was observed for methanol and ethanol. Measurements were made of the burning rate and liquid surface temperatures of the fuels. The data were compared with variable property analysis of the combustion process, including a correction for natural convection. The burning rate predictions of the various theories were similar and in fair agreement with the data. The high pressure theory gave the best prediction for the liquid surface temperatures of ethanol and propanol -1 at high pressure. The experiments indicated the approach of critical burning conditions for methanol and ethanol at pressures on the order of 80 - 100 atm, which was in good agreement with the predictions of both the low and high pressure analysis.

Canada, G. S.↗

Saturated fluorescence measurements of the hydroxyl radical in laminar high-pressure flames

The efficacy of laser saturated fluorescence (LSF) for OH concentration measurements in high pressure flames was studied theoretically and experimentally. Using a numerical model describing the interaction of hydroxyl with nonuniform laser excitation, the effect of pressure on the validity of the balanced cross-rate model was studied along with the sensitivity of the depopulation of the laser-coupled levels to the ratio of rate coefficients describing: (1) electronic quenching to (sup 2) Sigma (+) (v double prime greater than 0), and (2) vibrational relaxation from v double prime greater than 0 to v double prime = 0. At sufficiently high pressures and near-saturated conditions, the total population of the laser-coupled levels reaches an asymptotic value, which is insensitive to the degree of saturation. When the ratio of electronic quenching to vibrational relaxation is small and the rate of coefficients for rotational transfer in the ground and excited electronic states are nearly the same, the balanced cross-rate model remains a good approximation for all pressures. When the above ratio is large, depopulation of the laser-coupled levels becomes significant at high pressures, and thus the balanced cross-rate model no longer holds. Under these conditions, however, knowledge of the depletion of the laser-coupled levels can be used to correct the model. A combustion facility for operation up to 20 atm was developed to allow LSF measurements of OH in high pressure flames. Using this facility, partial saturation in laminar high pressure (less than or equal to 12.3 atm) C2H6/O2/N2 flames was achieved. To evaluate the limits of the balanced cross-rate model, absorption and calibrated LSF measurements at 3.1 and 6.1 atm were compared. The fluorescence voltages were calibrated with absorption measurements in an atmospheric flame and corrected for their finite sensitivity to quenching with: (1) estimated quenching rate coefficients, and (2) an in situ measurement from a technique employing two fluorescence detection geometries.

Carter, Campbell D.↗

A survey of compatibility of materials with high pressure oxygen service.

The literature on high pressure oxygen compatibility has been surveyed in order to present the existing state of knowledge. Searches have been conducted of NASA and NBS data retrieval systems. In addition, many individuals, active in the field, were contacted in order to retrieve useful unpublished information. Compatibility data, such as mechanical impact, pneumatic impact, ignition temperature, and flash-and-fire point, were compiled for pressures above 200 bar. Lower pressure data were included if they were useful for extrapolation to pressures above 200 bar. These data, too numerous to be given here, are available from the authors. Brief descriptions of the trends of these data are given. Recommendations for additional high pressure studies are included.

Hust, J. G.↗

A generalized theory for eccentric and misalignment effects in high-pressure annular seals

High-pressure annular seal leakage and dynamic coefficients vary with eccentricity and misalignment. Recent seal leakage data with both concentric and fully eccentric alignments support the seal leakage model with surface roughness and eccentricity effects included. In this paper, the seal dynamic coefficient calculation has been generalized and allows direct calculation of the seal dynamic coefficients at any circumferential location. The generalized solution agrees with the results obtained by using the calculated values of an earlier paper and performing a coordinate transformation. The analysis results coincide with the measured data in showing that the stiffness and damping matrices of seal coefficients are not skew symmetric, and the main diagonal seal coefficients are not equal. The measured direct stiffnesses were found higher than predicted by the concentric seal theory, but this may be explained by the presence of eccentricity in the test operating mode.

Chen, W. C.↗

Reusable High-Pressure Connector

Fluid line connector for high pressure tests has split ferrule, nut, and O-ring seal. Following test, ferrule nut, and O-ring fitting are removed leaving line unaltered except for bushing braze to free end. Connector assures strong joint for high-pressure testing without redundant parts requiring postest debrazing.

Jensen, H. O. C.↗

Performance of multimirror quartzline lamps in a high-pressure, underwater environment

Multimirror Quartzline Lamps are extremely versatile and effective for nonconventional imaging requirements such as high-speed photo and video instrumentation and high-magnification imaging. The lamps' versatility though, is not limited to conventional environments. Many research experiments and projects require a high pressure environment. Continuous photographic data acquisition in a high-pressure vessel requires wall penetrations and creates design problems as well as potential failure sites. Underwater photography adds the extra consideration of a liquid. This report expands upon the basic research presented in, Performance of Multimirror Quartzline Lamps in High-Pressure Environments, (NASA-TM-83793, Ernie Walker and Howard Slater, 1984). The report provides information to professional industrial, scientific, and technical photographers as well as research personnel on the survivability of lighting a multimirror quartzline lamp in a nonconventional high-pressure underwater environment. Test results of lighted ELH 300 W multimirror quartzline lamps under high-pressure conditions are documented and general information on the lamps' intensity (footcandle output), cone of light coverage, approximate color temperature is provided. Continuous lighting considerations in liquids are also discussed.

Slater, Howard A.↗

Depth Gauge for Liquids Under High Pressure

Piezoelectric element mounted in hole drilled in high-pressure plug. Transducer used to measure depth of liquid when pressure in vessel high. New configuration transmits ultrasonic vibration directly into liquid, enhancing signal strength, accuracy, and range, yet piezoelectric element protected from high-pressure liquid.

Zuckerwar, A. J.↗

NASA mechanical impact testing in high-pressure oxygen

Three independently developed high-pressure gaseous oxygen mechanical impact testers have been used to evaluate materials for the Space Shuttle Program. A test program evaluating the performance of these test systems is described. The gaseous and liquid oxygen test procedures and equipment are considered along with the material selection procedures. The results of the NASA mechanical impact tester variability study are presented, including penetration function curves and curve parameters and equivalent energies and comparisons of high-pressure testers at ambient pressure and temperature, ambient temperature and 34 MPa, and cryogenic temperature and 34 MPa. Finally, a summary of NASA mechanical impact test data is presented.

Bryan, C. J.↗