Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Dose Graphite”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Note: Gratings on low absorbing substrates for x-ray phase contrast imaging

Grating based X-ray phase contrast imaging is on the verge of being applied in clinical settings. To achieve this goal, compact setups with high sensitivity and dose efficiency are necessary. Both can be increased by eliminating unwanted absorption in the beam path, which is mainly due to the grating substrates. Fabrication of gratings via deep X-ray lithography can address this issue by replacing the commonly used silicon substrate with materials with lower X-ray absorption that fulfill certain boundary conditions. Gratings were produced on both graphite and polymer substrates without compromising on structure quality. These gratings were tested in a three-grating setup with a source operated at 40 kVp and lead to an increase in the detector photon count rate of almost a factor of 4 compared to a set of gratings on silicon substrates. As the visibility was hardly affected, this corresponds to a significant increase in sensitivity and therefore dose efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 03: Energy dependence of a clinical probe-format calorimeter and its pertinence to absolute photon and electron beam dosimetry

Purpose: To evaluate the intrinsic and absorbed-dose energy dependence of a small-scale graphite calorimeter probe (GPC) developed for use as a routine clinical dosimeter. The influence of charge deposition on the response of the GPC was also assessed by performing absolute dosimetry in clinical linac-based electron beams. Methods: Intrinsic energy dependence was determined by performing constant-temperature calorimetry dose measurements in a water-equivalent solid phantom, under otherwise reference conditions, in five high-energy photon (63.5 < %dd(10){sub X} < 76.3), and five electron (2.3 cm < R{sub 50} < 8.3 cm) beams. Reference dosimetry was performed for all beams in question using an Exradin A19 ion chamber with a calibration traceable to national standards. The absorbed-dose component of the overall energy dependence was calculated using the EGSnrc egs-chamber user code. Results: A total of 72 measurements were performed with the GPC, resulting in a standard error on the mean absorbed dose of better than 0.3 % for all ten beams. For both the photon and electron beams, no statistically-significant energy dependence was observed experimentally. Peak-to-peak, variations in the relative response of the GPC across all beam qualities of a given radiation type were on the order of 1 %. No effects, either transient or permanent, were attributable to the charge deposited by the electron beams. Conclusions: The GPC’s apparent energy-independence, combined with its well-established linearity and dose rate independence, make it a potentially useful dosimetry system capable measuring photon and electron doses in absolute terms at the clinical level.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental Plan for EDF Energy Creep Rabbit Graphite Irradiations- Rev. 2 (replaces Rev. 0 ORNL/TM/2013/49)

The experimental results obtained here will assist in the development and validation of future models of irradiation induced creep of graphite by providing the following data: Inert creep stain data from low to lifetime AGR fluence Inert creep-property data (especially CTE) from low to lifetime AGR fluence Effect of oxidation on creep modulus (by indirect comparison with experiment 1 and direct comparison with experiment 3 NB. Experiment 1 and 3 are not covered here) Data to develop a mechanistic understanding, including: appropriate creep modulus (including pinning and high dose effects on structure), investigation of CTE-creep strain behavior under inert conditions oInformation on the effect of applied stress/creep strain on crystallite orientation (requires XRD), effect of creep strain on micro-porosity (requires tomography & microscopy) This document describes the experimental work planned to meet the requirements of project technical specification and EDF Energy requests for additional Pre-IE work. The PIE work is described in detail in this revision (Section 8 and 9).

Burchell, Timothy D.↗

Multiscale characterization of irradiation behaviour of ion-irradiated SiC/SiC composites

Here, the irradiation tolerance of SiC/SiC composites was studied using 10 MeV Au ion irradiations at 350 °C, for surface doses between 1 and 50 displacements per atom (dpa). Atomic force microscopy and optical profilometry revealed irradiation-induced axial and radial shrinkage of SiC-fibers. At 50 dpa, net fiber shrinkage reached 2.8 ± 0.3%. We conclude that the primary cause of SiC-fiber shrinkage in SiC/SiC composites is the irradiation-induced loss of pre-existing carbon packets, which had occupied 2–3% fiber volume in unirradiated state. A compelling evidence of the carbon packet loss was revealed using a combination of state-of-art conventional transmission electron microscopy (TEM), high resolution TEM, energy-filtered TEM and electron energy loss spectroscopy. Additionally, the carbon packet volume fraction decreased with increasing dose, reaching near-complete loss after 50 dpa. Carbon packet loss was further confirmed using Raman spectroscopy where the carbon D and G peaks disappeared after irradiation. In contrast, irradiation-induced swelling of 1 ± 0.5% was observed in the matrix after 50 dpa. The study also shows that up to 50 dpa, the multilayer pyrolytic-carbon (PyC) interface in the composite is highly irradiation tolerant as it maintained its morphology, graphitic nature and showed no signs of amorphization. Additionally, Raman spectroscopy revealed a saturation of TEM invisible disorder at 1 dpa for both ultra-fine grains of the fiber and the larger SiC-matrix grains. However, TEM visible extended defect formation such as dislocation loops were only detected in the larger matrix grains, thereby revealing a potential role of grain size on defect accumulation in SiC.

36 MATERIALS SCIENCE↗

Capacity fade in high energy silicon-graphite electrodes for lithium-ion batteries

A silicon-graphite blended anode is paired with a high capacity LiFePO 4 reference/counter electrode to track irreversibility and lithium inventory. The LiFePO 4 electrode provides a reliable, flat potential for dQ dV -1 analysis of Li x Si and Li x C electrochemical reactions. We can relate this electrochemistry to the morphological and physical changes taking place.

25 ENERGY STORAGE↗

Use of Accelerator Mass Spectrometry in Human Health and Molecular Toxicology

Accelerator mass spectrometry (AMS) has been adopted as a powerful bioanalytical method for human studies in the areas of pharmacology and toxicology. The exquisite sensitivity (10–18 mol) of AMS has facilitated studies of toxins and drugs at environmentally and physiologically relevant concentrations in humans. Such studies include risk assessment of environmental toxicants, drug candidate selection, absolute bioavailability determination, and more recently, assessment of drug-target binding as a biomarker of response to chemotherapy. Combining AMS with complementary capabilities such as high performance liquid chromatography (HPLC) can maximize data within a single experiment and provide additional insight when assessing drugs and toxins, such as metabolic profiling. Recent advances in the AMS technology at Lawrence Livermore National Laboratory have allowed for direct coupling of AMS with complementary capabilities such as HPLC via a liquid sample moving wire interface, offering greater sensitivity compared to that of graphite-based analysis, therefore enabling the use of lower 14 C and chemical doses, which are imperative for clinical testing. In conclusion, the aim of this review is to highlight the recent efforts in human studies using AMS, including technological advancements and discussion of the continued promise of AMS for innovative clinical based research.

59 BASIC BIOLOGICAL SCIENCES↗

Dual functionality of over-lithiated NMC for high energy silicon-based lithium-ion batteries

Owing to their high specific capacity and suitably low operating potential, silicon-based anodes are an attractive alternative to graphite in next-generation lithium-ion batteries. However, silicon anodes suffer from low initial coulombic efficiency and fast capacity decay, limiting their widespread application. Pre-lithiation strategies are highly appealing to compensate for irreversible active lithium loss and to boost the cell energy density. In this work, we maximize the cell energy density by direct pre-lithiation of the NMC (LiNi 0.5 Mn 0.3 Co 0.2 O 2 ) cathode to Li 1+x NMCO 2 without introducing inactive deadweight to either electrode. First, we demonstrate that Li 1+x NMCO 2 can be synthesized chemically, via reaction between NMC and lithium napthalide, and electrochemically. The NMC cathode is tolerant of a one-time over-lithiation up to 60 mA h g NMC -1 , giving capacity retention on par with untreated NMC in half cell electrochemical cycling. Using synchrotron X-ray absorption spectroscopy (ex situ) and diffraction (in situ), we demonstrate that higher amounts of over-lithiation lead to local structure distortion – driven by transition metal reduction to Jahn–Teller active Mn 3+ and Co 2+ – as well as bulk structural hysteresis during over-lithiation and layer “buckling” that increases the amount of lithium extracted from the structure in the charged state. The Li 1+x NMCO 2 with low-to-moderate over-lithiation capacity (23, 46, and 70 mA h g NMC -1 ) is proven to be a highly effective dual-purpose lithium source and cathode material in full cell tests with a commercially relevant Si–graphite anode. These cells show higher capacity, superior cycle life, and improved coulombic efficiencies when compared to those with stoichiometric NMC cathodes. Finally, this study introduces a new and simple method to pre-lithiate layered transition metal oxide cathodes, opening up new possibilities for the development of high energy density lithium-ion batteries with next-generation anodes.

25 ENERGY STORAGE↗

Long-Term Cycling of a Mn-Rich High-Voltage Spinel Cathode by Stabilizing the Surface with a Small Dose of Iron

The high-voltage, cobalt-free spinel cathode LiNi 0.5 Mn 1.5 O 4 (LNMO) is receiving extensive attention for lithium-ion batteries due to its low cost, high operating voltage and energy density, superior power density, and good thermal stability. However, its high operating voltage hampers its stability with commercial electrolytes and makes its practical viability challenging. We present here a Mn-rich LNMO cathode to encourage the disordering of Mn and Ni in the lattice and the incorporation of a small dose of Fe into Mn-rich LNMO (Fe-LNMO) to improve the cycling stability. The introduction of Fe further increases the cation disorder between Mn and Ni, thus enabling a better rate capability. Electron energy loss spectroscopy analysis indicates that Fe is concentrated on the surface, and X-ray photoelectron spectroscopy analysis shows that Fe-LNMO alleviates the aggressive reaction between the cathode surface and the electrolyte, thus stabilizing the interface and cycle life. Furthermore, a full cell assembled with a graphite anode with an areal capacity of 3 mA h cm –2 displays a capacity retention of 90% over 300 cycles. Furthermore, the present work demonstrates an effective way to promote cation disordering and lower the surface reactivity of LNMO with the electrolyte, thereby enhancing the conductivity, stabilizing the cathode–electrolyte interphase, and making LNMO promising for practical applications.

25 ENERGY STORAGE↗

Feasibility Studies of Parametric X-rays Use in a Medical Environment

Parametric X-rays (PXR) are produced from the interaction of relativistic electrons with the periodic structure of crystal materials. Smooth X-ray energy tunability is achieved by rotating the crystal with respects to the electron beam direction. Experiments at the Rensselaer Polytechnic Institute 60-MeV LINAC produce quasi-monochromatic X-rays (6-35 keV) from various target crystals to include highly oriented pyrolytic graphite (HOPG), LiF, Si, Ge, Cu, and W using electron beam currents up to 6 uA. These experiments demonstrate the first PXR images and some of the merits of thin metallic crystals. Recent experiments with a 100-{mu}m thick Cu crystal improve the Cu PXR (with energy {approx}12 keV) to Cu fluorescence ratio by a factor of 20 compared to a 1 mm-thick Cu crystal. This study uses Monte Carlo techniques to investigate (1) PXR dose compared to emissions from simulated Mo, Rh, and W anodes for mammography applications and (2) electron scattering effects when considering LiF111, Si111, and Cu111 PXR production using electron beams with energies of 20-30 MeV. Advantages in using monochromatic PXR compared to X-rays from Mo and Rh anodes in mammography applications result in a dose per incident photon reduction by a factor of 2. Using 20 MeV electrons, the thinner Cu111 crystal for 15 keV PXR production results in an electron scattering angle of 30.7+/-0.2 mrad offering the best potential for PXR from lower energy electro0008.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-energy D{sup +} and H{sup +} ion irradiation effects on highly oriented pyrolytic graphite

We have investigated the low-energy (100 eV) D{sup +} and H{sup +} ion irradiation effects on the structural and chemical properties of highly oriented pyrolytic graphite (HOPG). Structural disorder due to the ion irradiation was identified by the Raman spectroscopy, the D{sup +} irradiation giving rise to greater structural disorder than the H{sup +} irradiation. Only sp{sup 2} bonding was identified in the X-ray photoemission spectroscopy of the D{sup +}-irradiated HOPG, indicating no change in the surface chemical structure. The H{sup +} irradiation, on the other hand, gave rise to sp{sup 3} bonding and π−π{sup *} transition, the sp{sup 3} bonding increasing with increasing irradiation dose. It is thus shown that the chemical properties of the HOPG surface may be sensitively modified by the low-energy H{sup +} ion irradiation, but not by the low-energy D{sup +} ion irradiation.

36 MATERIALS SCIENCE↗

"Source Term Modeling for Advanced Gas Micro-Reactors"

Maintaining the safety of the public, environment, and operating personnel is the most important factor in designing, operating, maintaining, and decommissioning nuclear reactors. In recent years, there has been a growing interest in the development of micro-reactors employing TRi-structural ISOtropic (TRISO)-coated particle fuel. In gas reactors, TRISO fuel plays an important role in the safety case for high temperature reactors because of the fission product retention properties of the fuel. This ability enables the use of a functional containment strategy for the reactor where multiple barriers are used to prevent fission product release to the environment. Part of the safety analysis of these advanced reactors is the assessment of radionuclide releases under normal and accident conditions through the multiple credited safety barriers. Using conservative assumptions, a mechanistic analysis can be performed to quantify these releases that combines the probabilistic assessment of failure with analytic solutions to radionuclide transport equations. Source term modeling for TRISO fuel has been performed for previous reactor designs; however, these models are outdated, in many cases proprietary, and need updates to be applied to the current state of TRISO fuel technology and alternative gas reactor core configurations [1]. Currently, the only publicly available source term assessment for gas reactors is an expert-based Monte Carlo simulation based on the effectiveness of the fuel kernel, coating layers, and graphite block in a modular high temperature gas reactor [2]. Thus, there is a need to develop a simple, versatile, and mechanistic model of fission product release and transport in gas reactor cores that could be applied to a variety of reactors through user inputs and reactor-specific radionuclide inventories. The release is calculated by the diffusion of the key safety important fission products through the kernel, silicon carbide (SiC), graphite for both intact and defective TRISO particles based on fuel and graphite temperatures in the reactor under normal operation. These releases from the fuel enter the coolant where they can plate-out on cooler surfaces. A clean-up model is included for designs with a coolant purification system to remove fission gases. This initial distribution of fission products in the reactor serves as an initial condition for potential releases under postulated accident conditions. The model then can calculate the fission product release for any transient temperature profile and fission product releases can then be used to assess radiological dose to the workers and the public using conventional dose tools. Data on the diffusion of fission products is based on historic German TRISO experiments and the more current Department of Energy (DOE) Advanced Gas Reactor (AGR) TRISO fuel development program. The model is coded in python with inputs and outputs in excel spreadsheets, as well as python plotting utilities to aid in the interpretation of the results. References: [1] INL, NGNP Mechanistic Source Term White Paper, INL-10-17997, July 2010. [2] David A. Petti, Richard R. Hobbins, Peter Lowry, Hans Gougar, “Representative Source Terms and The Influence of Reactor Attributes on Functional Containment in Modular High Temperature Gas-cooled Reactors,” Nuclear Technology, Vol. 184, p. 181-197, Nov. 2013.

07 ISOTOPE AND RADIATION SOURCES↗

AGC-2 Graphite Preirradiation Data Analysis Report (Revision 1)

This report described the specimen loading order and documents all pre-irradiation examination material property measurement data for the graphite specimens contained within the second Advanced Graphite Capsule (AGC-2) irradiation capsule. The AGC-2 capsule is the second in six planned irradiation capsules comprising the Advanced Graphite Creep (AGC) test series. The AGC test series is used to irradiate graphite specimens allowing quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear graphite grades to be generated which will ascertain the in-service behavior of the graphite for pebble bed and prismatic Very High Temperature Reactor (VHTR) designs. Similar to the AGC-1 specimen pre-irradiation examination report, material property tests were conducted on specimens from 18 nuclear graphite types but on an increased number of specimens (512) prior to loading into the AGC-2 irradiation assembly. All AGC-2 specimen testing was conducted at Idaho National Laboratory (INL) from October 2009 to August 2010. This report also details the specimen loading methodology for the graphite specimens inside the AGC-2 irradiation capsule. The AGC-2 capsule design requires “matched pair” creep specimens that have similar dose levels above and below the neutron flux profile mid-plane to provide similar specimens with and without an applied load. This document utilized the neutron flux profile calculated for the AGC-2 capsule design, the capsule dimensions, and the size (length) of the selected graphite and silicon carbide samples to create a stacking order that can produce “matched pairs” of graphite samples above and below the AGC-2 capsule elevation mid-point to provide specimens with similar neutron dose levels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Radiological and Thermal Characteristics of Fission Waste from a Deep-Burn Fusion-Fission Hybrid (LIFE) and Implications for Repository Performance

We are studying the use of a Laser Inertial-confinement Fusion Engine (LIFE) to drive a hybrid fusion-fission system that can generate electrical power and/or burn nuclear waste. The system uses the neutrons from laser driven ICF to produce tritium and to drive nuclear reactions in a subcritical fission blanket. The fusion neutron source obviates the need for a self-sustaining chain reaction in the fission blanket. Either fissile or fertile could be used as fission fuel, thus eliminating the need for isotopic enrichment. The 'driven' system potentially allows very high levels of burnup to be reached, extracting a large fraction of the available energy in the fission fuel without the need for reprocessing. In this note, we discuss the radionuclide inventory of a depleted uranium (DU) fuel burned to greater than 95% FIMA (Fissions per Initial heavy Metal Atom), the implications for thermal management of the resulting waste, and the implications of this waste for meeting the dose standards for releases from a geological repository for high-level waste. The fission waste discussed here would be that produced by a LIFE hybrid with a 500-MW fusion source. The fusion neutrons are multiplied and moderated by a sequence of concentric shells of materials before encountering the fission fuel, and fission in this region is largely due to thermal neutrons. The fission blanket consists of 40 metric tons (MT) of DU, assumed to be in the form of TRISO-like UOC fuel particles embedded in 2-cm-diameter graphite pebbles. (It is recognized that TRISO-based fuel may not reach the high burnup of the fertile fuel considered here, and other fuel options are being investigated. We postulate the existence of a fuel that can reach >95% FIMA so that the waste disposal implications of high burnup can be assessed.) The engine and plant design considered here would receive one load of fission fuel and produce {approx}2 GWt of power (fusion + fission) over its 50- to 70-year lifetime. Neutron and photon transport calculations were performed using MCNP5. Burnup calculations were performed using a modified version of Monteburns 2.0. The nuclear data used were from ENDF/B-VII. Additional details of the burn calculations can be found in. For comparison to spent fuel from light water reactors (LWRs), we use the projected initial inventory of PWR and BWR fuels (current average age of 23 years since discharge) used for the Yucca Mountain Project Final Environmental Impact Statement. The decay of this initial inventory to 1 million years was calculated using ORIGEN2. The hybrid system considered here would have generated {approx}44 GWe-yr of energy at 99% FIMA. The energy generated per MT is therefore about 1100 MWe-yr/MT. In contrast, using average burnups of 41.2 GWt-day/MT and 33.6 GWt-day/MT for the PWR and BWR fuel slated for disposal at Yucca Mtn., and assuming a thermal electric conversion efficiency of {approx}33%, the total energy generated by the 68,000 MT 'Yucca Mtn. inventory' is {approx}2500 GWe-yr, or {approx}37 MWe-yr/MT, which is {approx}30 times less energy per MT than the waste from the hybrid. Clearly, relative to the current once-through fuel cycle, the use of a deep-burn hybrid to generate electricity would significantly reduce the need for repository capacity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SEMI-EMPIRICAL MODELING OF IRRADIATION-INDUCED DIMENSIONAL CHANGE IN H-451 NUCLEAR GRAPHITE

Nuclear graphite has been used as a moderator material in nuclear reactor designs dating back to the first reactor to reach criticality, Chicago Pile 1, in 1942. In addition, it is anticipated to be used in the conceptual Generation four (GenIV) Molten-salt reactors (MSRs) and the High-temperature gas-cooled reactors (HTRs). The macroscopic dimensional change observed in irradiated nuclear graphite is a property change of significant importance. Largely, volumetric change provides valuable insight into the in-service lifetime of graphite components used in nuclear reactors. The dimensional change behavior varies amongst each grade of nuclear graphite due to processing techniques and the resulting microstructure. In this work, historic data for nuclear graphite H-451 is revisited. A semi-empirical methodology is proposed to describe the dimensional change behavior as a function of temperature for nuclear graphite H-451. The turnaround dose, or when there is a reversal of the dimensional change from contraction to expansion, is proposed to be a thermally activated process and thus can be described by an Arrhenius model. On the atomic scale, H-451 is sp2-bonded carbon atoms with some degree of disorder regardless of orientation. Towards that end, the activation energy is assumed to be a constant irrespective of orientation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-2 Graphite Preirradiation Data Analysis Report

This report describes the specimen loading order and documents all preirradiation examination material property measurement data for graphite specimens contained within the Second Advanced Graphite Capsule (AGC 2) irradiation capsule. The AGC 2 capsule is the second in six planned irradiation capsules comprising the Advanced Graphite Creep (AGC) test series. The AGC test series is used to irradiate graphite specimens in order to garner quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear grade graphites. This testing will ascertain the in service behavior of the graphite for pebble bed and prismatic very high temperature reactor designs. Similar to the First Advanced Graphite Capsule (AGC 1) preirradiation examination report, material property tests were conducted on specimens from 18 nuclear grade graphite types. However, AGC 2 tested an increased number of specimens (i.e., 512) prior to loading them into the AGC 2 irradiation assembly. All AGC 2 specimen testing was conducted at Idaho National Laboratory from July 2009 to August 2010. This report also details the specimen loading methodology for graphite specimens inside the AGC 2 irradiation capsule. The AGC 2 capsule design requires “matched pair” creep specimens that have similar dose levels above and below the neutron flux profile mid plane. This provides similar specimens with and without an applied load. Analysis in this document utilizes the neutron flux profile calculated for the AGC 2 capsule design, the capsule dimensions, and the size (i.e., length) of the selected graphite specimens to create a stacking order that produces “matched pairs” of graphite specimens above and below the AGC 2 capsule elevation mid point, thus providing specimens with similar neutron dose levels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TU-F-BRE-03: Application of a Novel Mass-Density Compensation Optimization Method to Improve the Response of a Liquid-Filled Ionization Chamber in Nonstandard Fields

Purpose: To improve the response of the microLion detector (PTW 31018) in small field conditions by optimizing the density of the detector's non-sensitive components using a novel method based on the detector's dose response function. Methods: The central values h(0,0) of the perturbation functions for the microLion detector and a volume of water equivalent to its sensitive volume were calculated using the Monte Carlo user code egs-chamber by scoring the dose absorbed by a 6 MV photon pencil beam incident on their centroids. Values of h(0,0) were plotted as a function of the density of the microLion's graphite electrode with the detector placed in the axial orientation. The optimized density was found by finding the minimal value of h(0,0). Results: A density of 1.37 g/cm3 was found to minimize the perturbation function of the microLion detector. The modified microLion's response was then evaluated in small square fields with sides in the range of 5 – 40 mm and found to be consistent with highly watere-quivalent detectors such as a scintillating detector (Exradin W1) and a generic alanine detector in both axial and radial orientations. Conclusion: This work illustrates a novel method which can used to optimize the design of radiation detectors in small fields. This method should also work with other optimization parameters (e.g. thickness of electrode). Density-compensated detectors have the potential to eliminate the need to evaluate nonstandard field correction factors as described by the IAEA-AAPM formalism (Alfonso et al.) and simplify future dosimetry protocols for SRS/SBRT modalities. Finally, we also expect an improvement in the response of density-compensated detectors for composite IMRT fields.

07 ISOTOPE AND RADIATION SOURCES↗

AGC-1 Post Irradiation Examination Status

The Next Generation Nuclear Plant (NGNP) Graphite R&D program is currently measuring irradiated material property changes in several grades of nuclear graphite for predicting their behavior and operating performance within the core of new Very High Temperature Reactor (VHTR) designs. The Advanced Graphite Creep (AGC) experiment consisting of six irradiation capsules will generate this irradiated graphite performance data for NGNP reactor operating conditions. All six AGC capsules in the experiment will be irradiated in the Advanced Test Reactor (ATR), disassembled in the Hot Fuel Examination Facility (HFEF), and examined at the INL Research Center (IRC) or Oak Ridge National Laboratory (ORNL). This is the first in a series of status reports on the progress of the AGC experiment. As the first capsule, AGC1 was irradiated from September 2009 to January 2011 to a maximum dose level of 6-7 dpa. The capsule was removed from ATR and transferred to the HFEF in April 2011 where the capsule was disassembled and test specimens extracted from the capsules. The first irradiated samples from AGC1 were shipped to the IRC in July 2011and initial post irradiation examination (PIE) activities were begun on the first 37 samples received. PIE activities continue for the remainder of the AGC1 specimen as they are received at the IRC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing and Characterization to Develop a Mechanistic Explanation for Unsaturated Drift of Fiber Optic Sensors during High-Dose Irradiation

The primary limitation for any optical fiber-based sensor for nuclear reactor applications is radiation-induced attenuation (RIA) of the transmitted and/or reflected signals. Based on several recent studies, RIA is tolerable for some fused silica optical fibers with the proper choice of sensing wavelength and fiber dopants. For extreme temperature applications (> 1000°C), sapphire optical fibers have been proposed; however, recent optical transmission measurements performed on bulk sapphire samples showed prohibitively large RIA. For some sensors, radiation-induced dimensional changes in the fiber materials can also cause significant drift. Moreover, the drift that was observed in numerous experiments performed in the High Flux Isotope Reactor (HFIR), the Advanced Test Reactor, the Massachusetts Institute of Technology Reactor, and other international facilities far exceeded what would be expected based on compaction of fused silica glass. Clearly, additional work is needed to better understand the origins of both RIA and radiation-induced drift in both silica and sapphire optical fiber-based sensors before these sensors can be reliably deployed for nuclear applications. This work evaluated the underlying mechanisms that may be responsible for RIA and drift in silica and sapphire materials. First, detailed characterization was performed on bulk fused silica glass samples that were previously irradiated to different neutron fluences at different temperatures to better understand the structural changes that drive radiation-induced drift in the absence of coating effects that are discussed later. Results show that the non-monotonic compaction that occurs with increasing neutron fluence continues up to fast neutron fluences approaching 10 22 n/cm 2 , which has important implications for physics-based models that may be used to compensate for the sensor drift. Initial Raman spectroscopy and synchrotron x-ray diffraction provide insights into the nature of the structural changes. Next, detailed characterizations were performed on silica fibers with various coatings that were subjected to several different thermal treatments. The hypothesis is that the coatings convert to carbon-rich materials that compact under irradiation, putting a large compressive strain on the fiber. Out-of-pile testing confirms that both polyimide and acrylate fiber coatings convert to glassy carbon (GC) materials when heated under inert conditions, and the degree of order (i.e., graphitization) increases with increasing temperature. The results provide increasingly strong evidence that the combination of polymeric coatings and inert (or vacuum) conditions render fiber optic sensors susceptible to significant radiation-induced drift that would not otherwise exist in uncoated fibers. Finally, transmission electron microscopy was performed on bulk sapphire samples that were irradiated to two neutron fluences at different temperatures to gain insights into the potential mechanisms driving the prohibitive RIA at higher neutron fluences and temperatures. Contrary to previous hypotheses, results show that scattering from radiation-induced voids cannot explain the observed RIA. Similarly, models for scattering losses from dislocation loops also do not agree with the experimental results. Instead, fitting to the experimental data shows that increased absorption from aluminum vacancy centers is the most likely explanation for the the prohibitively large RIA that was observed at high irradiation temperature and dose. In addition, the voids that formed in these single-crystal samples were found to align along the basal plane (a-axis) as opposed to that seen in previous observations of c-axis alignment in polycrystalline samples, which could have important implications for anisotropic swelling and other phenomena that could affect sensor performance at high neutron fluence.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗