Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Conjugate Heat Transfer Analysis of the Supercritical CO2 Based Counter Flow Compact 3D Heat Exchangers

Compact heat exchangers using supercritical fluids such as CO2 are preferred due to their high heat transfer capacity and smaller footprint. Three-dimensional conjugate forced convection heat transfer analysis was performed on several shell-and-tube counter-flow microchannel heat exchangers. Numerical simulations were conducted to test effect of change in mass flow rate, hydraulic diameter and various cross sections on the heat transfer. Increasing mass flow rate improved heat transfer up to a maximum value and then decreased downstream with increasing turbulence. Maximum heat transfer was obtained for the micro channel with the smallest hydraulic diameter. Amongst the cross sections analyzed (circular, square, circular with radial ribs, and square with radial ribs), the most uniform distribution of temperature and maximum heat transfer were obtained for circular cross section with radial ribs. An optimally efficient operation of such a heat exchanger can be attained by considering these factors during multi-objective constrained optimization of geometric parameters and requirements for additive manufacturing of such compact heat exchangers.

Chitale, Janhavi↗

Carbon and energy cost impacts of electrification of space heating with heat pumps in the US

In order to meet climate goals, it will be necessary to significantly reduce the greenhouse gases emitted by homes. A key factor in the US is to reduce the on-site combustion of fossil fuels for heating end-uses and to replace this with use of electric heat pump technologies connected to a low-carbon grid. The replacement of natural gas furnaces with electric heat pumps is a key home decarbonization strategy. However, the potential for space heating electrification to reduce greenhouse gas emissions depends on the carbon dioxide equivalent (CO 2 e) content of the electricity used by the heat pump. This varies considerably depending on the source of electricity, with large state to state variability. Furthermore, household energy costs are likely to be impacted by the electrification of space heating, because retail energy prices for both natural gas and electricity in each state vary by factors of seven and four, respectively. Contractors, energy programs, government and building code officials, as well as consumers need clear indications of the likely CO 2 e and energy cost impacts of proposed electrification projects, because these will affect decarbonization choices and rationales around scaled heating electrification. Government and utility programs also need to be aware of the likely outcomes of any supported/incentivized measures. Here, in this paper, we investigate these effects by looking at new metrics to analyze the change in CO 2 e emitted and the cost to meet home heating loads when switching from a natural gas furnace to a heat pump for the contiguous 48 states of the mainland US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental investigation of Multi-Mode heat transfer to a Free-Falling dilute particle cloud in a heated vertical tube

The development of dilute particle heat exchangers and reactors for advanced energy systems requires an understanding of the multi-mode heat transfer from a heated wall to falling particles. This study presents experimental results of the overall heat transfer coefficient for a free-falling, dilute flow of particles with solid volume fraction from 0.0005 to 0.006 corresponding to feed rates from 3.7 kg s -1 m -2 to 44 kg s -1 m -2 in a vertical, heated tube containing quiescent air at atmospheric pressure. Tube wall temperatures are varied between 300°C to 900°C while keeping the particle inlet temperature constant. The experimental results show that the overall heat transfer coefficient is a strong function of particle feed rate and surface temperature. Good agreement was obtained with prior studies conducted at comparable temperatures but lower particle feed rates (< 4 kg m -2 s -1 ). The established correlations for particle-to-wall radiation and particle-to-gas convection were used to estimate the wall-to-gas convective contribution from the measured overall heat transfer coefficient. The experimental results indicated a 4 to 6 times improvement in the wall convection in the solid-gas mixture compared to that expected from natural convection in a single-phase gas. Furthermore, the data presented here are applicable to characterize heat transfer in dilute particle heat exchangers, furnaces, and solar receivers.

14 SOLAR ENERGY↗

An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Application of a Novel Heat Pump Model for Estimating Economic Viability and Barriers of Heat Pumps in Dairy Applications in the United States

Heat pumps represent an important opportunity for energy savings and decarbonization. This work investigates the techno-economic performance of high-temperature heat pumps (HTHPs) for use in the U.S. dairy industry. The studied heat pump performs a 50 °C temperature lift on a waste heat stream of cleaning water and applies the upgraded heat stream to a fluid milk pasteurization process. This work involved the creation of a HTHP model that estimated the coefficient of performance (COP), internal rate of return (IRR), net present value (NPV), and payback period (PBP), and emissions saved for a heat pump replacing a natural gas boiler. Capital costs, operations, and maintenance (O&M) cost, heat pump lifetime, electricity prices, natural gas prices, and a cost of carbon were varied to perform a parametric study on the factors affecting the break-even price of HTHPs. The results show that HTHP economics are highly sensitive to COP and energy price environment, and less sensitive to capital and O&M cost variance, leading to a large scatter of positive and negative NPVs based on U.S. location. PBPs demonstrate a defined threshold, based on energy price environment, below which favorable two-to-three-year PBPs predominate. This work is focused on the U.S. dairy industry, but international application in relation to fossil vs. electricity price regimes. Heat pumps have seen wider adoption in regions with a high ratio of fossil energy to electricity prices ($/MMBTU vs. $/kWh). The U.S. has plentiful natural gas resulting in lower fossil energy prices which has reduced heat pump adoption. This paper identifies potential first mover industries for HTHP adoption and their associated price regimes even in regions with lower ratios of fossil energy to electricity prices that exist many places globally.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

A Simple Criterion for Feasibility of Heat Integration between Distillation Streams Based on Relative Volatilities

In a multicomponent distillation configuration, there are numerous sources and sinks of heat, and a potential way to reduce the heat duty requirement is to perform heat integration. Unfortunately, an algorithmic search of the optimal heat integration opportunities is intractable when the required temperatures of intermediate streams are computed via complex models. Instead, in this work, we introduce pressure-scaled pseudo relative volatility, a new metric to compare stream temperatures. Here, we justify the use of pseudo relative volatility by proving that this variable is a monotonically increasing function of the liquid fraction in a saturated mixture stream. Using this metric, we derive a shortcut criterion to check the feasibility of various heat integration opportunities, such as thermal coupling via heat transfer (TCH). The advantage of this approach is that it circumvents the need for explicit temperatures and instead relies on composition, component relative volatilities, and pressure—quantities that are readily available in shortcut models for optimization of distillation configurations. Leveraging this fact, we propose a new optimization framework that identifies feasible TCHs that we consider within the formulation while minimizing the total heat duty of a distillation configuration. We demonstrate, on a few examples, that our formulation can identify heat duty efficient configurations, some of which are multieffect configurations. Using this methodology, we discover configurations that are not only simpler than the fully thermally coupled (FTC) configuration but also have a much lower heat duty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating a solar parabolic trough collector plant used for industrial process heat using an optimized operating scheme that utilizes flexible heat integration

This study focuses on the modeling and simulation of a novel design and operation of a solar industrial process heat (SIPH) plant that uses a parabolic trough collector system for generating process heat. The SIPH plant incorporates flexible heat integration (FHI) by having two options for heat sinks as well as a flexible collection temperature for the heat transfer fluid. Leveraging the degrees of freedom created by FHI allows an optimized operating scheme to be created which maximizes the solar heat delivered to the industrial processes. Yearly results for a 27 MW-t plant located in Salt Lake City, UT are simulated for a base case and a case utilizing optimized FHI. For the main process temperature case presented, FHI increases the total solar share by 13.0% and reduces the levelized cost of heat of the SIPH plant by 10.4% relative to the base case. Furthermore, three case study days are presented which highlight how FHI maximizes solar share, specifically during mornings, afternoons, and days with intermittent solar conditions. An environmental analysis is also performed showing that the SIPH plant can reduce harmful emissions by 15.4% for the base case and 17.4% for the FHI case compared to a plant that only utilizes a natural gas furnace for process heat. Overall, the work thoroughly explores an effective operating scheme for a SIPH plant, helping to make it more economical and environmentally beneficial.

14 SOLAR ENERGY↗

Testing of a 40-kWth Counterflow Particle-Supercritical Carbon Dioxide Narrow-Channel, Fluidized Bed Heat Exchanger

Particle-based primary heat exchangers (HXs) must deliver sCO2 fluid temperatures above 700°C to couple particle-based concentrating solar receivers and thermal energy storage (TES) sub-systems with efficient sCO2 power cycles. Particle-sCO2 HX designs have struggled to meet DOE cost targets (≤ $150/kWth) due to the amount of expensive nickel alloys necessary for manufacturing full-scale, particle-sCO2 HXs. Our team has demonstrated that mild bubbling fluidization of falling particles in a counterflow narrow-channel fluidized bed can reduce required HX surface area and thus, costs by increasing particle-wall heat transfer coefficients hT,w > 800 W m-2 K-1. This paper reports on the fabrication and testing of a stainless steel, particle-sCO2 HX with 12 fluidized-bed channels approximately 10.5 mm deep spaced between diffusion-bonded, micro-channel sCO2 plates. The HX with a core length of ≈0.56 m is fed with CARBOBEAD HSP particles through a short, fluidized freeboard zone just above the core. Testing to date in the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories has shown that parallel bed fluidization maintains uniform particle inventory across the instrumented channels. Heat transfer thermal duty between the particle and sCO2 flows exceeds 30 kWth with sCO2 inlet temperatures of 200ºC and particle inlet temperatures up to 440ºC and mass flow rates of 0.2 kg s-1 fluidized by counterflowing gas flow rates of 0.005 kg s-1. Tests at higher particle and sCO2 inlet temperatures (600ºC and 400ºC respectively) are targeted to achieve > 40 kWth with model-predicted overall heat transfer coefficients U > 400 W m-2 K-1.

14 SOLAR ENERGY↗

Non-linear dependence of ion heat flux on plasma density at the L–H transition of JET NBI-heated deuterium–tritium plasmas

Abstract Recent JET D–T campaigns opened the possibility of unique isotope studies to investigate the L–H transition physics in view of reactor plasmas and to study the origin of the observed power threshold minimum. In the present paper, we characterise L–H transitions in the low and high-density branches of JET NBI-heated D–T plasmas. As discussed in the paper, L–H transition has been hypothesised to be determined by the transport power losses of plasma ions, i.e. the so-called ion heat flux ( Q i ). We present the first power balance analysis of JET NBI-heated D–T plasmas to evaluate the ion heat flux at the transition. Due to the experimental setting being similar to previous JET D experiments, we also directly compare the results, discussing the isotope effect and similarities between datasets. First, we find an isotope effect between D and D–T Q i , with a lower Q i in D–T plasmas. We confirm that the ion heat flux deviates from density linearity compared to the linear trend observed in wave-heated D plasmas of other tokamaks. The deviation we observe in NBI-heated L–H transitions happens at an isotope-dependent density. Plasma edge rotation correlates with Q i deviation from density linearity in the low-density branch. However, further investigations would be required to assess the role of rotation on Q i and the power threshold minimum at JET. At low plasma density, NBI power dominates Q i , while increasing the density makes the equipartition power dominant. We finally compare our results with hypotheses proposed from evidence in other tokamaks to present a complete overview of ion heat flux analyses in D and D–T NBI-heated plasmas at JET.

Vincenzi, P. (ORCID:0000000251564354)↗

Predicting fatal heat and humidity using the heat index model

A unique wet-bulb temperature of 35°C is often used as the threshold for human survivability, but recent experiments have shown that a person’s core temperature starts to rise at a wide range of critical wet-bulb temperatures. Here, it is shown that the model underlying the heat index correctly predicts those critical wet-bulb temperatures, explaining 95% of the variance in the values observed in laboratory heat-stress experiments. This is the first time the heat-index model has been validated against physiological data from laboratory experiments. For light and moderate exertion in an indoor setting, the heat index model predicts that the critical wet-bulb temperature ranges from 20 to 32°C, depending on the relative humidity, consistent with experimental results. Furthermore, for the same setting and exertion, the heat index model predicts fatal wet-bulb temperatures ranging from 24 to 37°C. Recent experiments have identified the critical combinations of heat and humidity, in an indoor setting, above which an individual is unable to maintain a standard core temperature, indicating severe heat stress. It is shown here why this state of severe heat stress cannot be predicted using the wet-bulb temperature. Instead, it is shown that the recently extended heat index model can explain nearly all of the variance in the observed critical combinations of temperature and humidity, and can be used to calculate fatal combinations.

59 BASIC BIOLOGICAL SCIENCES↗

Heat Pump Retrofits for Central Plant Hydronic Heating Systems: A Software Toolkit for Screening and Design

Retrofitting existing central plants with high-efficiency heat pump technologies can play a crucial role in achieving long-term planning goals. Modern heat pump technologies are able to use waste heat recovery to meet a building's heating demand, but there is a lack of accessible tools designed for non-HVAC experts, such as building owners, to quickly and easily conduct what-if analysis, e.g., estimating retrofit costs and payback period for their partial or full equipment replacement. This paper introduces an open-source software toolkit designed to facilitate the initial screening and decision-making of heat pump retrofits in existing central plants using a building's yearly load profile from metered or utility bill data. The toolkit evaluates the technical and economic viability of replacing traditional central plant equipment with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. The toolkit offers (1) a web-based tool designed for user-friendly access by a broad audience and (2) Python-based source code for researchers and engineers conducting parametric studies and design parameter optimization. The toolkit compares a typical central plant configuration to a configuration that uses a heat pump to supply hydronic heating and cooling. The output metrics include energy consumption and output of each equipment, life-cycle cost analyses and metrics, and environmental impact of the system.

Excell, L↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and validation of non-axisymmetric heat flux simulations with 3D fields using the HEAT code

A new comprehensive module to simulate heat fluxes from three-dimensional (3D) magnetic fields has been implemented in the HEAT code. Especially compact tokamaks like SPARC require tools to predict and manage large heat fluxes. Existing release versions of HEAT can only simulate axisymmetric heat flux on 3D plasma facing components. The new module uses an M3D-C1 perturbed equilibrium and the MAFOT code to trace field lines of the perturbed 3D magnetic field. Heat flux is then assigned to the resulting footprints via a 3D layer model. The model distinguishes between the scrape-off layer, the magnetic lobes and the private flux region, and employs only 0D parameters like the layer width, diffusive spread and the last closed flux surface position in the perturbed edge to generate a heat flux profile. The magnitude is normalized to the total input power. Resulting heat flux simulations are compared and validated against infrared measurements in the DIII-D tokamak with applied 3D fields; good agreement is found for several cases. The new module can now be applied to the SPARC tokamak; a preliminary result for applied rotating 3D fields is shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Management System for an Electric Machine with Additively Manufactured Hollow Conductors with Integrated Heat Pipes: Preprint

This paper discusses steps taken to size a thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal FEA is used to determine optimum heat transfer coefficient of convective boundaries. Geometric details of fin-based surface area enhancement required to reach target combined overall heat transfer coefficient (U) and surface area (A) performance (UA) in W/K, is worked out for relevant boundaries and the resulting UA is verified in 3D thermal FEA. Thermal management system's UA (by extension specific power) sensitivity to coolant temperature is explored and temperature distribution plots of optimized machine components are presented and discussed.

additive manufacturing↗

Making Small-Volume Heat Pump Water Heaters Larger: A Design Framework for Integrated Phase Change Material Heat Exchangers

Those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. One major barrier to wider HPWH adoption is the added equipment required, which prevents current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). PCMs have been studied extensively in building envelope and HVAC systems, but remain a nascent technology in residential water heating. While water itself has a uniquely high energy storage capacity, PCMs have an even higher energy storage density, thus providing the potential to elevate the performance of 40-gallon HPWHs to that of 50-gallon or larger tanks. This research is part of a larger project that seeks to utilize thermal energy storage to enable decarbonized water heating in low-income communities. In this study, we outline the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. In order to ensure optimal PCM utilization and tank storage capacity, we focus here on co-maximizing surface area and PCM volume in the heat exchangers; therefore, this research targets triply periodic minimal surface (TPMS) lattices. TPMS lattices boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries and offer highly tailorable designs; thus, they pair well with the growing field of additive manufacturing, or 3D printing. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives.

25 ENERGY STORAGE↗