Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat transfer performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Multicomponent gas mixture parametric CFD study of condensation heat transfer in small modular reactor system safety

Safety is always the primary concern for designing and analyzing nuclear reactor systems. The requirements for the safety margin for advanced small modular reactor (SMR) systems are targeted even higher than the conventional commercial large-scale nuclear reactors incorporating the passive and inherent safety systems. The SMR systems are designed with the condensation passive containment cooling system (PCCS), which plays a critical role in removing reactor heat during a steam release accident case. However, the presence of non-condensable gas (NCG), like air, reduces the heat transfer performance. This physics phenomenon becomes multifactorial for nuclear reactor containment during a fuel failure accident case that releases hydrogen gas. Besides, the mixture component of steam-air-hydrogen varies in reactor accident cases, which need simulation and validation keeping parameters of importance. Reviews showed that previous studies for SMR’s PCCCS did not cover the condensation heat transfer (CHT) in the presence of multicomponent NCG mixture parametric computational fluid dynamics (CFD) simulation and validation, making a research gap in the SMR design safety. A comprehensive CHT parametric CFD study was performed for SMR PCCS to fill this research gap. This study used experimental data as simulation 3D physics domain inlet and outlet boundary conditions. However, the wall boundary conditions were constant temperature, curve-fit, and annular coolant for verifying the turbulence models. Parametric simulations were performed, verified, and optimized for steam-NCGs mixtures. The multicomponent gases, multiphase mixtures, and fluid film condensation models were applied with associated turbulence models. The results of the parametric study were evaluated for realistic reactor conditions. Results showed that parametric study provided critical insight about the dependency of multicomponent gas mixture parameters that supports reactor safety design, analysis, and licensing.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Numerical Study on the Energy Performance of a Novel Furnace With Acidic Gas Trap Absorbers

Natural gas furnaces are widely used in US residential and commercial building markets. An important issue for natural gas furnaces is serious corrosion and fouling problems caused by acidic gas, such as SOx. An advanced adsorption technology based on acidic gas trap (AGT) absorbers offers the possibility to remove SOx acidic gas from natural gas furnaces with high efficiency and low cost, thereby enabling the development of condensing furnaces without the use of expensive corrosion resistant materials in the heat exchanger. A three-dimensional (3D) computational fluid dynamics (CFD) model has been developed to evaluate the heat transfer performance of a furnace with AGT absorbers and to compare it with a baseline conventional furnace without the AGT. Moreover, an axisymmetric model has been built focusing on the absorbing process in the AGT. The baseline conventional furnace used for the study is a commercial condensing furnace (Rheem 92% AFUE 84,000 BTU Multi-Position Gas Furnace). This furnace was completely disassembled, and the dimensions of each part were carefully measured and used to build a detailed CFD model. A model representing the new furnace, incorporating the AGT absorbers, was developed by adding the AGT system to the conventional furnace model. For the CFD analysis, a mixture model was employed to characterize the heat and mass transfer during the condensing process in the furnace while considering three components—air, water vapor and liquid water. Condensation takes place in the condensing heat exchanger, where water vapor changes phase to liquid water, and the latent heat is thus used in the furnace for useful heating. The simulation results characterize the energy performance of both the conventional furnace and the novel furnace with AGT absorbers, as well as the reactive processing in the AGT. These results provide insightful guidance for the development of the AGT absorber-based furnace from the perspective of its energy performance and will be used to further optimize this novel furnace design.

Laclair, Tim↗

Technical and economic evaluation of heat transfer fluids for a TES system integrated to an advanced nuclear reactor

The utilization of thermal energy storage technology has emerged as a potential enhancement for nuclear power plants. Although nuclear energy systems possess the ability to adjust their energy output, prolonged variations in production can impact the plant's overall efficiency and economic viability. However, the nuclear industry can capitalize on thermal energy storage to bolster the power plant's economics by leveraging ancillary services and market hedging strategies. Here this research aims to advance the development of thermal energy storage for advanced nuclear reactors by assessing the thermophysical properties of various heat transfer fluids, including FLiNaK, KCl-MgCl 2 , LiCl-KCl, (LiNaK) 2 CO 3 , NaF-ZrF 4 , and KF-ZrF 4 , at temperatures ranging from 500 to 900oC. The assessment is conducted based on thermophysical correlations established in previous studies and employs figures of merit as a metric to evaluate the heat transfer performance of different salt candidates. Additionally, a cost analysis is conducted to provide an idea of the potential cost associated with each salt candidate.

25 ENERGY STORAGE↗

Thermal Performance of Triply Periodic Minimal Surface Lattice Structures in Single-Phase Dielectric Fluid Cooling of Power Electronics

Additive manufacturing has transformed thermal management by enabling the production of complex, optimized geometries that conventional manufacturing methods cannot achieve. This study investigates the single-phase convective heat transfer performance of gyroid triply periodic minimal surface (TPMS) lattice structures with functional porosity. TPMS structures provide high surface area to volume ratios and are amenable to 3D printing. A gyroid numerical model was created and validated against an existing experimental study with a similar feature size to the investigated geometries. The TPMS structure has a periodic width of 1.6 mm, a length of 10 mm, and a height of 4 mm, with a functional porosity ranging from 0.5 to 0.8, decreasing with distance from the heated surface. Three different flow configurations were examined for an inlet fluid temperature of 70 °C. The inlet velocities range from 0.01 to 1.2 m/s, corresponding to a Reynolds number range of 10–900 with a heat flux of 50 W/cm 2 applied at the base. AmpCool ® AC-110 dielectric fluid (Prandtl number 59.5) was used as the coolant. Thermal performance and friction characteristics were studied for the three flow orientations. The parallel flow configuration was identified as the most efficient for heat removal. A detailed analysis of the numerical results highlights the underlying physics behind the thermal performance differences among the flow configurations.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling of crystallization fouling on a horizontal-tube falling-film evaporator for thermal desalination

Scale formation within horizontal-tube falling-film evaporators is an important issue for thermal desalination, because of the deterioration of heat transfer performance and added maintenance costs. Predicting the fouling process is crucial for desalination plant design, operation, and maintenance. In this paper, a model is developed to predict the crystallization fouling process during seawater falling-film flow over a horizontal tube bundle. The scaling is estimated based on deposition theory, with couple heat transfer including the in-tube steam condensation, conduction through the tube wall and the scale layer, and falling-film evaporation. The spatial and temporal variations of temperature, heat transfer coefficient, and scale thickness are predicted, and the effects of variations in process parameters of steam, feed seawater, and tube properties on the scale thickness, evaporation rate, and heat transfer coefficient for falling-film evaporation are analyzed. Comparisons to existing experimental data show the scaling layer thickness falls in the general range of reported measurements, with a slight overestimation due to neglecting the delay of scaling onset under real conditions. The scale layer thickness increases dramatically as the in-tube steam pressure is increased or the seawater flow rate is decreased. In general, the scaling layer becomes thicker on the lower tubes in the tube bundle, due to the heat and mass transfer of the falling film. The effect of tube material on scaling appears mainly dependent on thermal conductivity; thus, using polymer rather than a stainless steel tube decreases scaling and evaporation rate 96% and 88%, respectively. Finally, this work has potential to guide thermal desalination plant design, material selection, and operating parameter optimization.

42 ENGINEERING↗

A remarkable CHF of 345W/cm 2 is achieved in a wicked-microchannel using HFE-7100

Boiling heat transfer of dielectric fluids is a promising cooling technique for thermal management of microelectronic systems. However, the critical heat flux achievable is generally low, because of the poor thermophysical properties of these fluids. Here, to address this dilemma, we propose a new cooling concept to substantially enhance global liquid supply during phase-change process using enhanced capillary-driven force. Additionally, dedicated vapor pathways are designed among a bank of micro-pillars to facilitate vapor removal. In this work, new wicks comprised of silicon micro-pinfin arrays are explored to significantly enhance the flow boiling heat transfer performance. To examine the functionalities of this wick, experiments on HFE-7100 were carried out with mass velocities varying from 247 to 3,465 kg/m 2 s. To explore the enhancement mechanisms and to analyze the capillary-assisted flow boiling process, visualization studies were conducted. The results indicate that sustainable evaporation induced by wick microstructures and efficient liquid supply are the enhancement mechanisms compared to parallel microchannels with solid walls. It is found that the overall heat transfer coefficient is substantially increased up to 75%. Remarkably, a high critical heat flux (CHF) of approximately 345 W/cm 2 is recorded at G = 3,465 kg/m 2 s at coolant inlet temperature of ~20 °C. Equally importantly, this noticeable enhancement of CHF value is associated with drastically decreased pressure drops compared to microchannels decorated with μ-pinfin fences.

36 MATERIALS SCIENCE↗

Effect of Wettability Gradient on the Scale Formation in Falling Film Flow

Mitigation of scale formation and performance degradation remains a vital challenge for falling film evaporators in various industries. In this work, an experimental study of falling film flow on a horizontal tube is conducted to investigate the effects of wettability gradients on thermal, hydraulic, and fouling behavior. It is revealed that certain hydrophobic coating patterns, such as strip, ring, and grid patterns, lead to unwetted heat transfer area, which results in decreased heat transfer compared to fully wetted plain tube. By adjusting the geometry and position of the wettability gradient, the hybrid coating demonstrates improved heat transfer performance. Based on the characteristics of horizontal tube falling film flow, impinging jet, thin film flow, and liquid retention at the tube bottom, a hybrid coating pattern is developed to improve surface wetting and mitigate the scaling coverage. It is revealed that scale deposition is regulated by wettability gradient. Crystals tend to be dense and compact in hydrophilic areas, while they appear scattered or even absent in hydrophobic regions, depending on the dimension of the hydrophobic area. While at the hydrophilic/hydrophobic boundary, a noticeable scale thickness step is observed, which raises the potential for self-cleaning. Furthermore, the balance of minimization of scaling layer coverage and maximization of wetting area requires an optimal design in coating dimensions, for which a systemic study of both flow dynamics and fouling characteristics on the falling film is necessary in the future.

42 ENGINEERING↗

Sensitivity study on the fin effect of thermocouple mounted on the heated surface under film boiling condition

In the reactivity-initiated accident (RIA) scenario, right after the power burst with the occurrence of departure from nucleate boiling (DNB), the cladding temperature quickly reaches its maximum and is maintained in a steady film boiling regime. Then, under limited heat transfer performance of film boiling, the local cooling effect by the thermocouple wire may not be neglected. A computational model is developed to estimate the local cooling effect of the thermocouple wire mounted on the cladding surface under film boiling condition. The model predicts the temperature profile along the cladding surface as physically expected and is verified against the benchmark problem. Sensitivity studies reveal the significant effects of the thickness of vapor film layer and the diameter of thermocouple on the temperature drop near the thermocouple, for they increase the heat transfer area to the liquid water region. The impact of film boiling heat transfer coefficient, however, is not significant, as the primary heat transfer mechanism near the thermocouple is the heat conduction to the wire. Future study will include the contribution of radiative heat transfer between the cladding surface and the vapor film layer, as well as a transient power history which represents an actual RIA scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ADDITIVELY MANUFACTURED SURFACE HEAT TRANSFER ENHANCEMENTS FOR THE TRANSFORMATIONAL CHALLENGE REACTOR

The Transformational Challenge Reactor (TCR) is a high-temperature gas-cooled reactor design that uses additively manufactured fuel elements. TCR fuel elements have walls made of silicon carbide and are filled with tristructural-isotropic fuel particles. These fuel elements can have radically different shapes and integrated features than existing designs due to the reduced cost for complex structures in binder jet additive manufacturing. As such, binder jet additive manufacturing enables wall surface features to be embedded that can deliver superior heat transfer performance than smooth wall designs. In this work, the authors conducted a computational fluid dynamics study to evaluate selected wall features integrated into TCR fuel elements. Results show that surface features can outperform smooth wall designs; however, there are unique challenges for gas-cooled reactor core designs that have not been fully explored by previous research. For example, the rough surface finish and process variability of ceramics additive manufacturing make it challenging to predict surface roughness effects before fabrication. Additionally, the small hydraulic diameters of coolant channels in reactor cores make it difficult to engineer surface features that do not significantly increase the pressure drop. Engineers must carefully size surface features for heat transfer enhancement in additive fuel elements to operate above the base material's surface roughness effects and below the coolant channel size.

Weinmeister, Justin↗

Design Overview of a High-Pressure Helium Flow Visualization Apparatus for Blanket Cooling Studies

Cooling of the fusion blanket first wall remains a significant challenge given the adverse conditions of heat and particle flux encountered near the plasma. Helium emerges as an attractive cooling candidate because of its chemical and neutronic inertness and separability from hydrogenic species (e.g. tritium). Because of the low thermal mass of helium, optimization of these coolant channels is warranted to provide high heat transfer performance at low pumping costs. Increasingly, computational fluid dynamics (CFD) simulations are employed to model and optimize these flow channels, and accompanying experimental data are needed to validate the predictions of these models. To provide the aforementioned experimental data, a high-pressure helium flow visualization upgrade has been designed for the Helium Flow Loop Experiment facility. This apparatus was built to American Society of Mechanical Engineers boiler and pressure vessel standards to withstand operating pressure of 4 MPa and mated to high-pressure glass windows. Seedless flow visualization is performed via high-speed background oriented schlieren (BOS), with image correlation used for time-resolved two-dimensional velocimetry at frequencies in excess of 60 kHz. Rectangular flow channel test articles are additively manufactured via laser powder bed fusion and installed into this visualization apparatus, with one-sided heating supplied by resistive heaters. In conclusion, the chosen test geometries were informed by prior CFD simulations, and the helium flow structures observed via BOS (detachment, recirculation, etc.) will be used for the validation of these accompanying models, in support of the design and optimization of blanket cooling channel configurations.

Helium flow↗

Experimental results of a magnetically coupled piezoelectric actuator to relieve microchannel heat exchanger maldistribution

Refrigerant maldistribution is a common issue in microchannel heat exchangers. Refrigerant maldistribution can have significant negative effects on the heat transfer performance and increase the pressure drop, leading to increased superheat temperature at the outlet and increased compressor work, lowering system efficiency. In this work, a novel piezoelectric-driven magnetic actuator (PEDMA) was fabricated and inserted into the inlet header of the microchannel evaporator, with the goal of improving the non-uniformity of the flow distribution by regulating the flow in the header to the microchannels. Two prototype PEDMA designs were tested and showed significant impact on the refrigerant flow in the region of actuation. In the first design, the experimental data showed superheat reductions up to 9 °C when the individual channel temperatures were measured. The second design redistributed the refrigerant such that a 1% increase in capacity was calculated for the whole heat exchanger without significantly impacting the heating efficiency. The experimental results demonstrate the successful operation of the PEDMA devices and represent a new method of active flow distribution control which is based on a simple design with minimal additional energy consumption, and which can be inserted into microchannel heat exchanger headers to potentially relieve the refrigerant maldistribution.

42 ENGINEERING↗

Laminar Flow Heat Transfer In Helical Oval-Twisted Tube for Heat Exchanger Applications

The heat transfer performance of a novel tube configuration that combines the swirling velocity induced by oval-twisting and secondary flow generated by a helical geometrical flow path is presented. The Nusselt number (Nu) and friction factor (f) are compared for the laminar flow regime (Re = 250- 2000) under isothermal wall conditions. Under the same flow and boundary conditions, the oval-twisted helical tube increased the Nu and slightly increased the f over the circular helical tube. The best performance with the highest Nuand lowest f occurs at the coil curvature ratio (d h /D) of 0.17. The quantified enhancement performance factor (h) shows a 46 - 56% increase for the oval-twisted helical tube over the circular helical tube with d h /D = 0.17. Correlations for the Nu and f are developed and agreed with the numerical results: ± 6% and ± 5% for the Nu and f, respectively.

42 ENGINEERING↗

Numerical modeling based machine learning approach for the optimization of falling - film evaporator in thermal desalination application

Scale formation that drastically increases thermal resistance and reduces freshwater production remains a critical challenge in thermal desalination. Novel designs of falling film evaporator and optimal operating condition hold great promise to mitigate scale formation, and increase heat transfer performance and fresh water production. In this work, CFD simulation based machine learning and multi-objective optimization are performed to identify optimal conditions and tube arrangement for evaporator. Non-dominated sorting genetic algorithm is adopted to determine and analyze the optimal pareto front for multiple objectives in desalination criteria. The errors of training, validation, and testing set are computed to identify an optimal hyperparameter set. For performance ratio, fouling resistance, and water production rate, the average relative error is 2.26%, 3.67%, and 3.24%. At pareto front, both performance ratio and water production rate increase at high temperature with fouling resistance (thermal resistance of the fouling layer) increasing as well. Tradeoffs between mitigating scale formation and enhancing desalination performance are evaluated in optimizations for different objectives. Finally, potential optima are identified and can be applied as guidelines to determine evaporator design and system operating conditions.

42 ENGINEERING↗

Flow instabilities in helical-coil steam generators for small modular reactors: A review

Here, this study covers the research and discoveries in two-phase flow-boiling instabilities available in the literature—specifically for a helical-coil steam generator (HCSG), including experimental findings, theoretical research, computational models, and system code analyses—supporting research and development of representative small modular reactors (SMRs). Like other new and advanced reactor systems, water-cooled SMRs require experimental data from both integral and separate thermal-hydraulics test facilities for the verification and validation (V&V) of the computational models and computer codes in order to design and obtain regulatory approval. The complex dynamics of two-phase flow-boiling instabilities includes flow regimes physics phenomena, flow-channel geometries, heat-transfer behavior, and interactions among the solid–liquid-gas within the system boundary, all of which are pivotal for understanding the design and operational challenges of SMRs. This study focuses on identifying the relevant knowledge gaps on boiling instabilities—specifically for a HCSG—and provides insights about future research direction optimizing the transport of thermal energy, mass-flow rates, and boundary conditions that ensure the adequate heat-transfer performance, operational stability, and safety associated with SMR systems.

20 FOSSIL-FUELED POWER PLANTS↗

An Innovative Zero-Liquid Discharge Intermediate-Cold-Liquid Eutectic-Freeze Desalination System

A novel freeze desalination technology is presented for purification of water produced from various industrial processes, including oil and gas extraction. The main innovative idea is introducing a water-immiscible intermediate-cold-liquid (ICL) medium which absorbs the cold from a refrigeration cycle and transfers it to a freezing chamber where it is mixed with brine. The cold ICL enters the freezing chamber at temperatures between -10°C to -30°C. Precooled brine in injected into the freezing chamber and pure water freezes out of the brine upon mixing with the ICL. The rate of freezing inside the chamber is controlled by adjusting the flow rate of the cold ICL relative to the inlet brine. Both eutectic freeze and non-eutectic freezing are possible by controlling the temperature of the freezing chamber. The solid-liquid slurry created in the freezing chamber flows to a filter separation unit after passing through a separation column. The ice crystals are separated from the liquid by a rotary filter device. The collected ice is rinsed by a centrifugal unit. The rinsed ice is melted to produce fresh water. The developed technology resolves the issues common to current freeze-desalination systems while offering superior heat transfer performance ascribed to direct-contact between the cooling medium and the brine in addition to producing solid salt and pure water. The system operates under atmospheric pressure. The low operation temperature minimizes the corrosion issues common in systems exposed to brine. Also, due to the low operating temperature, there are no concerns about evaporation of volatile organics from the produced water during the treatment. The developed technology effectively eliminates the use of chemicals for pretreatment of brine. The system can be constructed from commercially available components. Extensive testing using a lab-scale prototype by using synthetic brine and actual produced water with TDS values from 50,000 ppm to 300,000 ppm showed that freshwater could be achieved with relatively small dependency on the quality of the input brine. The quality of the treated water was found to be mainly a function of the duration of the centrifugal process. Treated water with TDS as low as 200 ppm could be achieved in the tests. Thermo-economic modeling coupled with system level thermochemical process model were developed for prediction of the LCOW. The LCOW was predicted to be $\$$0.50 to $\$$0.90 per barrel of produced water. The potential markets for deployment of the technology are the oil and gas, in-land thermoelectric powerplants, RO desalination plants, and mining industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Novel Hot Gas Components for Gas Turbine Engines Enabled by Materials and Additive Manufacturing Process Development

Additive Manufacturing (AM), also known as 3D printing, has emerged as a manufacturing method that enables new design freedom for gas turbine engine manufacturers. However, the material selection for AM processable high-temperature super alloys is currently limited. Additionally, the heat transfer performance of AM enabled micro-cooling architectures is not yet well understood. Accordingly, in support of advanced manufacturing and engine performance development, Oak Ridge National Laboratory (ORNL)and Solar Turbines (Solar) conducted a multidisciplinary project to generate both AM super alloy material properties data and micro-channel performance data for two AM super alloys. The data supported the design and analysis of an internally cooled turbine hot section AM tip shoe component. This data was used to analytically predict the reduction in operating temperature of a gas turbine tip shoe. The work concluded that the cooling flow required to cool the tip shoe can be tuned to suit the efficiency improvements desired in an industrial gas turbine.

36 MATERIALS SCIENCE↗

On the validity and limitations of 1D model for heat and mass transfer performance evaluation in a multilayer binder-free desiccant dehumidifier: isothermal dehumidification with internal cooling

Efficient humidity control is essential for maintaining indoor thermal comfort, yet conventional vapor-compression-based dehumidifiers are energy-intensive. Employing separate sensible and latent cooling through desiccant-coated heat exchangers (DCHEs) combined with evaporative coolers offers energy savings of up to 80 % compared to conventional systems. However, the dehumidification performance of DCHEs remains limited due to the use of polymer binders for coating desiccant materials onto heat exchange surfaces. In our previous study, we developed a multilayer fixed-bed binder-free desiccant dehumidifier (MFBDD) that demonstrated high dehumidification capacity and low pressure drop compared to rotary desiccant wheels. Nevertheless, its potential for further enhancement through internal cooling and the use of step-shaped adsorption isotherms has not been explored. In this study, a physics-based one-dimensional (1D) transient model is developed and validated to capture the coupled heat and mass transfer processes in the MFBDD and extended to simulate internal cooling using a high-capacity composite metal–organic framework, MIL-101/GO-6 (water uptake ≈1.6 g/g within 35–47 % RH). The model enables detailed analysis of local air and bed temperature dynamics and quantifies how internal cooling affects the dehumidification performance under a wide range of operating conditions. Results show that integrating internal cooling and using MIL-101/GO-6 enhance mass adsorbed, moisture removal capacity, and dehumidification effectiveness by 50 %–99 % compared with the M.S. Gel baseline. The study further reveals that achieving near-isothermal operation requires simultaneous enhancement of the convective heat transfer coefficient and heat exchange surface area. In conclusion, this work provides the first detailed physical insight into the interplay between internal cooling and step-shaped isotherms in a binder-free desiccant device and establishes a validated modeling framework for scaling up and system-level performance evaluation of next-generation energy-efficient dehumidification systems.

Heat and mass transfer↗