Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Pilot testing of a heat integrated 0.7 MWe CO 2 capture system with two-stage air-stripping: Amine degradation and metal accumulation

An advanced 0.7 MWe small pilot coal-fired post-combustion CO 2 capture system with heat integration combined with two-stage stripping was tested here on a slipstream of flue gas by the University of Kentucky Center for Applied Energy Research (UKy-CAER). Evaluation of solvent degradation products was performed to determine the impact of oxygen exposure due to incorporation of the secondary air stripper into the conventional amine absorber/stripper system. The overall degradation rates and products observed during the testing campaign were comparable to previously published reports using 30% monoethanolamine (MEA) as the baseline/commissioning solvent. The rates of heat stable salt accumulation and amine degradation were similar to those from conventional CO 2 capture systems using MEA. Metal accumulation as the result of material corrosion inside the system from an improperly constructed material was observed. Finally, the impact of the secondary air stripper appears negligible relative to other published MEA campaigns tested at similar flue gas conditions and system operating hours.

03 NATURAL GAS↗

Integral Heat Transfer Test Method for Determining Thermal Resistance of Silicon Carbide Cladding and Liquid Tin System at Elevated Temperatures - Master's Thesis Presentation University of Idaho

Presentation for master's work at University of Idaho discussing Integral Heat Transfer Test Method for Determining Thermal Resistance of Silicon Carbide Cladding and Liquid Tin System at Elevated Temperatures. Presentation covers slight literature review results/previous work, discussions on system design and approach for thermal property measurement of SiC composite and Tin system, modeling efforts, and results.

36 - MATERIALS SCIENCE↗

Air-Source Integrated Heat Pump System Development – Final Report

Between October 2007 and September 2017, Oak Ridge National Laboratory (ORNL) and Lennox Industries, Inc. (Lennox) engaged in a Cooperative Research and Development Agreement (CRADA) to develop an air-source integrated heat pump (AS-IHP) system for the US residential market. The Lennox AS-IHP concept consisted of a high-efficiency air-source heat pump (ASHP) for space heating and cooling services and a separate heat pump water heater/dehumidifier (WH/DH) module for domestic water heating and dehumidification (DH) services. A key feature of this system approach with the separate WH/DH is capability to pretreat (i.e., dehumidify) ventilation air and dedicated whole-house DH independent of the ASHP. Two generations of laboratory prototype WH/DH units were designed, fabricated, and lab tested. Performance maps for the system were developed using the latest research version of the US Department of Energy/ORNL heat pump design model (Rice 1992; Rice and Jackson 2005; Shen et al. 2012) as calibrated against the lab test data. These maps served as the input to TRNSYS (Solar Energy Laboratory et al. 2010) to predict annual performance relative to a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (i.e., a combination of an ASHP with a seasonal energy efficiency ratio (SEER) of 13 and resistance water heater with an energy factor (EF) of 0.9). Predicted total annual energy savings (based on use of a two-speed ASHP and the second-generation WH/DH prototype for the AS-IHP), while providing space conditioning, water heating, and dehumidification for a tight, well-insulated 2600 ft2 (242 m2) house at three US locations, ranged from 33 to 36%, averaging 35%, relative to the baseline system. The lowest savings were seen at the cold-climate Chicago location. Predicted energy use for water heating was reduced by about 50 to 60% relative to a resistance WH.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Heat Switch/Oxide Sorption Compressor

Thermally-driven, nonmechanical compressor uses container filled with compressed praseodymium cerium oxide powder (PrCeOx) to provide high-pressure flow of oxygen gas for driving closed-cycle Joule-Thomson-expansion refrigeration unit. Integrated heat switch/oxide sorption compressor has no moving parts except check valves, which control flow of oxygen gas between compressor and closed-cycle Joule-Thomson refrigeration system. Oxygen expelled from sorbent at high pressure by evacuating heat-switch gap and turning on heater.

Bard, Steven↗

Advanced Variable Speed Air-Source Integrated Heat Pump (AS-IHP) Development (Final Report)

Between August 2011 and September 2015, Oak Ridge National Laboratory (ORNL) and Nordyne, LLC (now Nortek Global HVAC LLC, NGHVAC) engaged in a Cooperative Research and Development Agreement (CRADA) to develop an air-source integrated heat pump (AS-IHP) system for the US residential market. Two generations of laboratory prototype systems were designed, fabricated, and lab-tested during 2011-2013. Performance maps for the system were developed using the latest research version of the DOE/ORNL Heat Pump Design Model, or HPDM, (Rice 1991; Rice and Jackson 2005; Shen et al 2012) as calibrated against the lab test data. These maps were the input to the TRNSYS (SOLAR Energy Laboratory, et al, 2010) system to predict annual performance relative to a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (combination of 13 SEER air-source heat pump (ASHP) and resistance water heater with Energy Factor (EF) of 0.9). Predicted total annual energy savings, while providing space conditioning and water heating for a tight, well insulated 2600 ft2 (242 m2) house at 5 U.S. locations, ranged from 46 to 61%, averaging 52%, relative to the baseline system (lowest savings at the cold-climate Chicago location). Predicted energy use for water heating was reduced 62 to 76% relative to resistance WH. Based on these lab prototype test and analyses results a field test prototype was designed and fabricated by NGHVAC. The unit was installed in a 2400 ft2 (223 m2) research house in Knoxville, TN and field tested from May 2014 to April 2015. Based on the demonstrated field performance of the AS-IHP prototype and estimated performance of a baseline system operating under the same loads and weather conditions, it was estimated that the prototype would achieve ~40% energy savings relative to the minimum efficiency suite. The estimated WH savings were >60% and SC mode savings were >50%. But estimated SH savings were only about 20%. It is believed that had the test house been better insulated (more like the house used for the savings predictions noted above) and the IHP system nominal capacity been a bit lower that the energy savings estimate would have been closer to 45% or more (similar to the analytical prediction for the cold climate location of Chicago).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot testing of a heat integrated 0.7 MWe CO 2 capture system with two-stage air-stripping: Emission

The University of Kentucky Center for Applied Energy Research (UKy-CAER) designed, constructed and tested an advanced 0.7 MWe post-combustion CO 2 capture system on a coal-fired power plant using a heat integration process combined with two-stage stripping to enhance the CO 2 absorber performance and lower the cost of CO 2 capture. Evaluation of emissions from the solvent and degradation products was performed to determine the impact on the amine solvent of coal combustion flue gas contaminants and oxygen exposure due to incorporation of the secondary air stripper into the conventional amine absorber/stripper system. The overall amine, ammonia and aldehyde emission levels observed during the baseline 30% monoethanolamine (MEA) solvent testing campaign were generally comparable to previously published reports tested at similar flue gas conditions and system operating hours. Ammonia emissions were correlated to high levels of iron and copper in the solvent, likely as a result of material corrosion.

20 FOSSIL-FUELED POWER PLANTS↗

Design and Test of a Structurally-Integrated Heat Sink for the Maxwell X-57 High Lift Motor Controller

An innovative thermal management solution was conceptualized, built and tested for the X57 Maxwell electric airplane. A combination of commercial CFD codes and bespoke thermal modeling tools were employed to rapidly develop a structurally-integral power electronics heat sink. A structurally-integrated heat sink was devised for the GIMC-SCEPTOR high lift motor controller. The nacelle-conforming sink is designed to dissipate heat from the power electronics assembly while simultaneously acting as the mechanical load path between the wing structure and high lift motor.

Edwards, Ryan↗

Refrigerant charge management in an integrated heat pump

A heat pump including an integrated system for the management of refrigerant charge is provided. The heat pump includes an indoor line and an outdoor line that are connected to a compressor through a reversing valve. Refrigerant charge is managed by coupling the inactive line to the suction side of the compressor. For example, the heat pump can include an expansion valve to couple the inactive line to the compressor to supplement the flow-rate of refrigerant. The heat pump is operable in a dedicated water heating mode and a space cooling and water heating mode in some embodiments, while other modes of operation are contemplated in other embodiments.

42 ENGINEERING↗

Aviation Mission Profile Performance Evaluation in a High Specific Power Surface Permanent Magnet Machine with Additively Manufactured Coils and Integrated Heat Pipes

The purpose of this paper is to accurately evaluate the performance and overall efficiency of an electrical machine driving a propeller (as a part of a hybrid or electric propulsion system) during the flight mission profile using electromagnetic-thermal simulations. The study focuses on a 250 kW, 5000 rpm, 1.25 kHz, 36/30 slot/pole surface permanent magnet (SPM) machine with additively manufactured (AM) hollow conductors and integrated heat pipes (HP). The machine drive parameters (frequency, and current) are tuned to maximize the efficiency for a given flight cycle, while providing the highest specific power (SP) during takeoff. Afterward using Multiphysics simulations, the transient thermal behavior of the machine is studied and temperature profile for different parts of the machine is extracted. Finally, steady-state temperatures during cruising are estimated and overall efficiency is re-evaluated.

additive manufacturing↗

Process for producing an activated carbon adsorbent with integral heat transfer apparatus

A process for producing an integral adsorbent-heat exchanger apparatus useful in ammonia refrigerant heat pump systems. In one embodiment, the process wets an activated carbon particles-solvent mixture with a binder-solvent mixture, presses the binder wetted activated carbon mixture on a metal tube surface and thereafter pyrolyzes the mixture to form a bonded activated carbon matrix adjoined to the tube surface. The integral apparatus can be easily and inexpensively produced by the process in large quantities.

Jones, Jack A.↗

Enhancing building resilience in cold climates: Integrating heat pump technologies with renewable energy

As electrification advances and Cold Climate Heat Pump technology progresses, ensuring grid stability becomes increasingly critical for effective heating in cold climates. However, natural disasters, especially during winter, pose significant threats to grid stability, impacting the reliability of air-source heat pumps. Despite these challenges, the integration of renewable energy sources and storage solutions in heating systems has not been extensively studied within the context of resilience. Here, this paper delves into the literature on renewable-powered heat pumps to assess their potential in enhancing building resilience in U.S. cold climate zones, which are particularly susceptible to extreme weather and grid disruptions. By leveraging renewable sources—solar, geothermal, and water—in conjunction with heat pump technology and supported by thermal or battery storage, this approach aims to provide a dependable solution for maintaining indoor heating during grid failures. Our analysis begins with a review of various renewable energy sources suitable for heat pumps, followed by an exploration of their application in cold climate regions across the U.S., and discussions on potential integration strategies with heat pump systems. This study highlights the advantages and suitability of solar irradiance and geothermal resources, emphasizing the importance of tailored, site-specific assessments to maximize energy efficiency and resilience. Additionally, it outlines the economic and environmental considerations necessary for implementing such systems and identifies potential challenges and areas for future research to facilitate the broader integration of renewable energy in heating solutions for enhanced resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing the Costs of Solid Sorbent-Based CO 2 Capture Process Through Heat Integration

The focus of this project was the ADAsorb™ CO 2 Capture Process, a temperature-swing adsorption process that incorporates a three-stage fluidized bed as the adsorber and a single-stage fluidized bed as the regenerator. ADAsorb™ system was designed, fabricated, and tested under DOE award DEFE0004343. Two amine-based sorbents were evaluated in conjunction with the ADAsorb™ process: “BN”, an ion-exchange resin; and “OJ”, a metal organic framework (MOF) sorbent. Two cross heat exchanger designs were evaluated for use between the adsorber and regenerator: moving bed and fluidized bed. The fluidized bed approach was rejected fairly early in the project because the additional electrical load to power blowers or fans to overcome the pressure drop required for fluidization was estimated to be nominally three times the electrical power that could be generated from the steam saved through the use of the cross heat exchanger. The Energy Research Center at Lehigh University built and utilized a process model of the ADAsorb™ capture process and integrated this model into an existing model of a supercritical PC power plant. The Lehigh models verified that, for the ADAsorb™ system, the largest contributor to parasitic power was lost electrical generation, which was primarily electric power which the host plant could not generate due to the extraction of low pressure (LP) steam for sorbent heating, followed by power for the CO 2 compressor and the blower or fan power required to fluidize the adsorber and regenerator. Sorbent characteristics such as the impacts of moisture uptake, optimized adsorption and regeneration temperature, and sensitivity to changes in pressure were also included in the modeling study. Results indicate that sorbents which adsorb more than 1-2% moisture by weight are unlikely to be cost competitive unless they have an extremely high CO 2 working capacity that well exceeds 15% by weight. Modeling also revealed that reductions in adsorber pressure drop could negatively affect the CO 2 adsorption characteristics for sorbents with certain isobar adsorption characteristics like sorbent BN. Thus, reductions in pressure drop do not provide the efficiency benefits expected. A techno-economic assessment conducted during the project revealed that without heat integration, the a metal organic framework (MOF) sorbent used in conjunction with the ADAsorb™ process provided the opportunity for improved performance over the benchmark MEA process. While the addition of a cross heat exchanger and heat integration was found to significantly improve net unit heat rate, the additional equipment costs required to realize these improvements almost always outweighed the improvement in performance. The exception to this was for a supported amine sorbent and the addition of a moving bed cross heat exchanger alone or in conjunction with waste heat from the compressor used for supplemental regenerator heating. Perhaps one of the most important points to be drawn from the work conducted during this project is the significant influence of sorbent characteristics alone on the projected COE and LCOE associated with the ADAsorb™ process, and the implications associated with future improvements to solid sorbent CO 2 capture. The results from this project suggest that solid sorbent CO 2 capture will continue to see performance gains and lower system costs as further sorbent improvements are realized.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated heat pipe-thermal storage system performance evaluation

An integrated thermal energy storage (TES) system, developed as a part of an organic Rankine cycle solar dynamic power system is described, and the results of the performance verification tests of this TES system are presented. The integrated system consists of potassium heat-pipe elements that incorporate TES canisters within the vapor space, along with an organic fluid heater tube used as the condenser region of the heat pipe. The heat pipe assembly was operated through the range of design conditions from the nominal design input of 4.8 kW to a maximum of 5.7 kW. The performance verification tests show that the system meets the functional requirements of absorbing the solar energy reflected by the concentrator, transporting the energy to the organic Rankine heater, providing thermal storage for the eclipse phase, and allowing uniform discharge from the thermal storage to the heater.

Keddy, E.↗

Motorette Thermal Performance Testing and Modeling for an Electric Motor with Additively Manufactured Hollow Conductors with Integrated Heat Pipes

This paper discusses the design, build and test of a motorette to characterize the thermal performance of an additively manufactured coil integrated with heat pipes. The motorette is powered using a variable frequency AC power supply and cooled through two independent cooling systems. The first cooling system cools the stator core using forced convection of air flowing over a finned heat sink mounted on the stator outer diameter. The second cooling system cools the heat pipes using forced convection of 50-50 water ethylene glycol (WEG) mixture flowing through condenser chambers. A 3D thermal FEA model of the setup is built and heat transfer coefficients (HTC) of convective boundaries are computed using coolant flow rates from test data and empirical equations. Temperature at locations on the coil and heat sink are recorded and compared to thermal model predicted values. A maximum temperature error of 22.7% occurs at 180ARMS and 800 Hz operating point for the AM dual coil. The thermal model provides higher temperatures compared to test results and hence it is on the conservative side but in general, there is good correlation between test and model results. Lastly, opportunities for improvement to both test data measurement and 3D thermal FEA modeling are discussed.

additive manufacturing↗

Thermal Management System for an Electric Machine With Additively Manufactured Hollow Conductors With Integrated Heat Pipes

Here, this paper discusses steps taken to develop a novel thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal finite element analysis is used to determine optimum heat transfer coefficient of the convective boundaries. For some of the convective boundaries, fin-based surface area enhancement is required to reach a target combined overall heat transfer coefficient and surface area performance (UA). This enhancement is worked out using a combination of the Engineering Equation Solver tool and 3D thermal FEA. The thermal management system's UA, and by extension its specific power, sensitivity to coolant temperature is explored. Temperature distribution plots of optimized machine components are also presented and discussed. Lastly, additional heat pipe testing is carried out to study its maximum heat transfer capability's sensitivity to condenser coolant temperature and configuration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field testing of two prototype air-source integrated heat pumps for net zero energy home (nZEH) application

By integrating multiple functions into a single system it offers potential efficiency and cost reduction benefits. Oak Ridge National Laboratory (ORNL) and its partners have designed, developed, and tested two air-source heat pump designs that not only provide space heating and cooling, but also water heating, dehumidification, and ventilation functions. Some details on the design, simulated performance, prototype field test, measured performance, and lessons learned are provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tank-Integrated Heat Exchanger for Boil-Off Reduction

The following document details the initial efforts of the Protium Company in developing reduced boil-off and zero boil-off liquid hydrogen tanks using Vapor-Cooled Shielding (VCS) technology. The intention is to improve upon the performance characteristics of traditional vacuum-jacketed dewars by reducing boil-off rate, cooldown time, and total boil-off during cooldown time while integrating the heat exchanger into the wall of the VCS tank. The work carried out during this project was limited, as the grant recipient The Protium Company was acquired by Plug Power Inc. on October 1st 2021, early in the performance period of the grant. As such, the extent of the work completed includes an initial estimation of the dimensions needed for a 0.1%/day boil-off VCS liquid hydrogen tank. These dimensions are derived from data gathered from sizes of previous VCS tanks. The dimensions and estimated boil-off rate for the VCS tank are by no means validated, and no design was generated for a zero boil-off tank.

08 HYDROGEN↗

Development of an integrated heat pipe-thermal storage system for a solar receiver

The Organic Rankine Cycle (ORC) Solar Dynamic Power System (SDPS) is one of the candidates for Space Station prime power application. In the low Earth orbit of the Space Station approximately 34 minutes of the 94-minute orbital period is spent in eclipse with no solar energy input to the power system. For this period the SDPS will use thermal energy storage (TES) material to provide a constant power output. An integrated heat-pipe thermal storage receiver system is being developed as part of the ORC-SDPS solar receiver. This system incorporates potassium heat pipe elements to absorb and transfer the solar energy within the receiver cavity. The heat pipes contain the TES canisters within the potassium vapor space with the toluene heater tube used as the condenser region of the heat pipe. During the insolation period of the Earth orbit, solar energy is delivered to the heat pipe in the ORC-SDPS receiver cavity. The heat pipe transforms the non-uniform solar flux incident in the heat pipe surface within the receiver cavity to an essentially uniform flux at the potassium vapor condensation interface in the heat pipe. During solar insolation, part of the thermal energy is delivered to the heater tube and the balance is stored in the TES units. During the eclipse period of the orbit, the balance stored in the TES units is transferred by the potassium vapor to the toluene heater tube.

Keddy, E. S.↗