Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Active heat exchange system development for latent heat thermal energy storage

Alternative mechanizations of active heat exchange concepts were analyzed for use with heat of fusion Phase Change Materials (PCM's) in the temperature range of 250 C to 350 C for solar and conventional power plant applications. Over 24 heat exchange concepts were reviewed, and eight were selected for detailed assessment. Two candidates were chosen for small-scale experimentation: a coated tube and shell that exchanger, and a direct contact reflux boiler. A dilute eutectic mixture of sodium nitrate and sodium hydroxide was selected as the PCM from over fifty inorganic salt mixtures investigated. Preliminary experiments with various tube coatings indicated that a nickel or chrome plating of Teflon or Ryton coating had promise of being successful. An electroless nickel plating was selected for further testing. A series of tests with nickel-plated heat transfer tubes showed that the solidifying sodium nitrate adhered to the tubes and the experiment failed to meet the required discharge heat transfer rate of 10 kW(t). Testing of the reflux boiler is under way.

Lefrois, R. T.↗

Performance characteristics of a combination solar photovoltaic heat engine energy converter

A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

Chubb, Donald L.↗

Combination solar photovoltaic heat engine energy converter

A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

Chubb, Donald L.↗

Performance characteristics of a combination solar photovoltaic heat engine energy converter

A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

Chubb, Donald L.↗

Atomic-Level, Energy-Conversion Heat Transfer

Abstract Heat is stored in quanta of kinetic and potential energies in matter. The temperature represents the equilibrium and excited occupation (boson) of these energy conditions. Temporal and spatial temperature variations and heat transfer are associated with the kinetics of these equilibrium excitations. During energy-conversion (between electron and phonon systems), the occupancies deviate from equilibria, while holding atomic-scale, inelastic spectral energy transfer kinetics. Heat transfer physics reaches nonequilibrium energy excitations and kinetics among the principal carriers, phonon, electron (and holes and ions), fluid particle, and photon. This allows atomic-level tailoring of energetic materials and energy-conversion processes and their efficiencies. For example, modern thermal-electric harvesters have transformed broad-spectrum, high-entropy heat into a narrow spectrum of low-entropy emissions to efficiently generate thermal electricity. Phonoelectricity, in contrast, intervenes before a low-entropy population of nonequilibrium optical phonons becomes a high-entropy heat. In particular, the suggested phonovoltaic cell generates phonoelectricity by employing the nonequilibrium, low-entropy, and elevated temperature optical-phonon produced population—for example, by relaxing electrons, excited by an electric field. A phonovoltaic material has an ultranarrow electronic bandgap, such that the hot optical-phonon population can relax by producing electron-hole pairs (and power) instead of multiple acoustic phonons (and entropy). Examples of these quanta and spectral heat transfer are reviewed, contemplating a prospect for education and research in this field.

Engineering↗

Recharge Demand Mitigation for Latent Heat Thermal Energy Storage at Off-peak Hours

The utilization of integrated heat pump thermal energy storage (HP-TES) systems for space conditioning applications can reduce electrical power demand and achieve utility savings resulting from peak shaving and load shifting. However, issues arise when the energy required to recharge the TES exceeds the shifted energy demand, especially in extreme climates where high-temperature lifts between the outdoor air conditions and phase-change materials (PCMs) during recharging may occur. In this work, a single room-temperature (22°C) PCM-TES is integrated into a single-speed heat pump system using a secondary hydronic loop where the TES is recharged using the outdoor unit during off-peak hours. Three recharge strategies were investigated as potential pathways to reduce recharging power demand: (i) considering different heat source/sink temperatures, (ii) using a variable-speed compressor, and (iii) using a variable-speed pump. Simulations were conducted using Modelica for HP-TES recharging at different heat source/sink temperatures from -30 – 20℃ in heating mode and 0 – 30℃ in cooling mode. Results show that the most effective recharge demand reduction strategy is an HP-TES system using a single-speed compressor with a variable-speed pump for the hydronic loop run at preferable heat source/sink temperatures when the temperature lifts were reduced. Utilizing a variable-speed compressor for the HP-TES system reduced recharge time in extreme cases at the cost of additional compressor power input. The findings motivate potential control strategies that minimize recharge energy and maximize peak energy savings, hence reducing overall operating costs and annual energy consumption for HP-TES systems for space conditioning applications.

25 ENERGY STORAGE↗

Solar energy to heat and cool a new NASA Langley office building

A solar heating and cooling system will be installed at a new NASA office building. The objective of this project is to establish a full-scale working test-bed facility to investigate solar energy for heating and cooling buildings. The energy collected will provide between 80 and 100 percent of the heating and cooling requirements during the cool months and between one-half and two-thirds of the cooling requirements in the summer. Thermal energy storage will be provided to bridge the gap between cloudy and clear days.

Maag, W. L.↗

Cold Climate Air-Source Heat Pump Demonstration and Analysis: Experimental Study on Cold Temperature Performance

Space heating energy is the largest end use for U.S. residential buildings, accounting for nearly 45% of residential building energy consumption nationwide, and approximately 51% of space heating energy is consumed on-site by combusting natural gas (EIA 2020a). In Colorado, approximately 53% of the statewide residential building energy consumption goes to space heating, 76% of which is provided by natural gas (EIA 2020a). Heat pumps are an efficient, electric alternative space heating technology and have been proven viable for decades. However, historically air-source heat pumps (ASHPs) have been limited to temperate climates because of (1) subpar performance at extremely cold outdoor air temperatures, (2) the need for air conditioning in summer months, and (3) the availability of natural gas in colder climates. Relatively recent advances to cold climate ASHP technology, which typically relies on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance, enabling the technology to potentially save energy for many homes in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A first principles framework to predict the transient performance of latent heat thermal energy storage

Thermal energy storage (TES) is increasingly recognized as an essential component of efficient Combined Heat and Power (CHP), Concentrated Solar Power (CSP), Heating Ventilation and Air Conditioning (HVAC), and refrigeration as it reduces peak demand while helping to manage intermittent availability of energy (e.g., from solar or wind). Latent Heat Thermal Energy Storage (LHTES) is a viable option because of its high energy storage density. Parametric analysis of LHTES in terms of dimensionless numbers is highly desired as a tool to model LHTES systems. One approach is to develop a model equation so as to minimize the error between the model and data obtained from experiments or simulations. While this approach can produce an accurate correlation applicable within the range of data used for its creation, it does not provide physical understanding of the rate-limiting process controlling the transient behavior of the device. In this paper we present an alternative approach whereby the potential rate-limiting processes are identified from first principles and then the key process is determined as a function of time as a LHTES device is charged. For example, in a simple geometry, the melt-fraction can be expected to vary linearly in time if the heat transfer rate is limited by natural convection of the phase changing material and we show it scales with the PCM Grashof number as $Gr^1_p$ and PCM Prandtl number as $Pr_p^{(1/3)}$. On the other hand, if surface area of solid PCM limits the heat transfer rate, the melt fraction increases asymptotically to reach full melting. The existence of these linear and asymptotic regions and the $Gr^1_pP r^{1/3}_p$ shape of the melt fraction curve is verified using our database of 64 simulations. Of practical importance in designing LHTES devices is the melt fraction at which the heat transfer rate ceases to be limited by convection, after which the heat storage rate deteriorates. For our geometry, this is found to be about 90%. This test case of our methodology shows the value of our approach, that predicting heat storage rate based on the rate-limiting physical phenomenon as a function of time is an effective approach to modeling LHTES devices.

25 ENERGY STORAGE↗

Experimental Analysis of Salt Hydrate Latent Heat Thermal Energy Storage System With Porous Aluminum Fabric and Salt Hydrate as Phase Change Material With Enhanced Stability and Supercooling

Phase change materials (PCMs), especially salt hydrates possess high volumetric energy storage capacity in their transition temperature range. These materials are used in applications where it is necessary to store thermal energy due to temporary load shift between demand and availability. Thus, possible applications are HVAC, recovery of waste heat, and defense thermal management. Despite salt hydrates potential, the practical feasibility of latent heat storage with salt hydrates is limited due to low power rating, supercooling, phase segregation, and long-term stability. Its low power rating and long-term stability limits its application in most applications. This work experimentally validates the stability and thermal performance of a compact heat exchanger charged with salt hydrate during melting and freezing. The compact heat exchanger was designed with fins on both the heat transfer fluid (HTF) and salt hydrate PCM side. The thermal performance of the latent heat thermal energy storage system (LHTESS) was evaluated for various operating conditions. The results show that LHTESS could achieve an average heat transfer coefficient of 124 and 87 W/(m2 K) during melting and solidification, respectively. The stability of the system in suppressing supercooling was validated over 800 cycles with nucleating agent and active homogenous nucleation techniques. The supercooling was reduced to 3 °C with zinc hydroxyl nitrate as nucleating agent and less than 1 °C with the active homogenous nucleation technique. The LHTESS showed less than 6% degradation in energy storage capacity over 800 cycles.

42 ENGINEERING↗

Thermion: Verification of a thermionic heat pipe in microgravity

The Idaho National Engineering Laboratory (INEL) is conducting intensive research in the design and development of a small excore heat-pipe-thermionic space nuclear reactor power system (SEHPTR). The SEHPTR spacecraft will be able to supply 40 kW of power in any given orbit. The key components in this reactor are the thermionic heat pipes. The heat pipes have two major functions: (1) to convert heat energy into electrical energy, and (2) to radiate the excess heat to space. Thermionic power conversion is the process of converting heat energy into electrical energy with no moving parts. Heat is applied to the cathode surface. This heat will boil off electrons that will jump across the gap to the cooler surface of the anode, which will cause a potential difference between the two plates and induce a current through the load. Thermionic power conversion is incorporated as part of the heat pipe. The heat pipe, which is being developed by Thermacore Inc., is actually two heat pipes. It uses a radial heat pipe, called the emitter, and an axial heat pipe collector. The emitter heat pipe will pass the heat from the nuclear core to the cathode surface. The collector heat pipe keeps the anode surface cooler by transferring the heat from the anode surface and radiating it to space.

Source record↗

Integrated Heat Exchanger/Thermal Energy Storage System for CSP Plants

The research and development during the project focused on the design and optimization of an integrated heat exchanger/thermal energy storage (HX/TES) system, the charging and discharging performance of the developed HX/TES system, and the experimental investigation of lab-scale prototypes based on the full-scale system.

42 ENGINEERING↗

Benefits assessment of cool skin and ventilated cavity skin: Saving energy and mitigating heat and grid stress

This study assessed the energy-saving and climate-adaptive potential of cool skin and ventilated cavity skin facade technologies in Seoul's high-rise apartment buildings. We created weather scenarios for historical, mid-term future, and long-term future conditions using Coordinated Regional Downscaling EXperiment (CORDEX) method. Building energy simulations were conducted on a South Korean high-rise apartment model to evaluate their performance under different weather conditions. The results indicate that cool skin and ventilated cavity skin technologies can save cooling energy during summers but lead to heating energy penalties in winters. Ventilated cavity skin outperforms cool skin, offering better cooling energy savings and reduced heating penalties. Combining both technologies yields the highest overall energy savings, with 7 %, 9 %, and 10 % cooling energy savings for cool skin, ventilated cavity skin, and the combined package, respectively. However, cool skin increases heating energy consumption by 5 %, while ventilated cavity skin has minimal impact on heating energy. These envelope technologies also reduce peak electricity demand by at least 5 %, 8 %, and 9 %, respectively. They contribute to heat stress reduction, enhance resilience, and decrease extreme heat risks for occupants during power outages by at least 18 % under various weather conditions. Considering the prevalence of aging high-rise apartments in South Korea, adopting these envelope renovation strategies can effectively reduce cooling loads, enhance thermal comfort, and boost resilience under future climates, while avoiding costly reconstruction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Low to high temperature energy conversion system

A method for converting heat energy from low temperature heat sources to higher temperature was developed. It consists of a decomposition chamber in which ammonia is decomposed into hydrogen and nitrogen by absorbing heat of decomposition from a low temperature energy source. A recombination reaction then takes place which increases the temperature of a fluid significantly. The system is of use for the efficient operation of compact or low capital investment turbine driven electrical generators, or in other applications, to enable chemical reactions that have a critical lower temperature to be used. The system also recovers heat energy from low temperature heat sources, such as solar collectors or geothermal sources, and converts it to high temperatures.

Miller, C. G.↗

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Consensus DOE Advanced Fuels Campaign TREAT/SATS Test Plan [Slides]

This record is comprised of summary slides of the Combined TREAT-LOC & SATS Integral LOCA Experiment Plan. The experimental program has been developed to specifically address data gaps and opportunities identified through detailed review of the existing public knowledgebase on LOCA FFRD and specific experimental development for prototypic LOCA conditions for LWR systems. The test program relies on a unique combination of in-pile and out-of-pile experimental approaches to (1) provide clear tieback to the existing integral and semi-integral LOCA experiment database using state-of-the-art facilities. More importantly, this program will systematically investigate the impacts of: (2) prototypic HBu fuel and cladding thermomechanical behaviors under postulated LWR LOCA conditions never fully investigated before. These conditions correspond with prototypic decay-energy heat up (DEH) and stored-energy heat up (SEH) conditions. Unique TREAT capability will provide first evaluation of SEH conditions on HBu fuels. The test program includes an emphasis on developing improved mechanistic understanding of key phenomena through independent experimental systems, development of a database to support fuel performance modeling tools, world leading advanced materials characterization, and the most advanced approach to in-situ diagnostics ever deployed to evaluate FFRD. The results will represent a significant leap forward in the evaluation of prototypic conditions and novel data to support modeling development and validation, as well as to inform the technical basis of LOCA-induced FFRD.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗