Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The importance of sub-meter-scale snow roughness on conductive heat flux of Arctic sea ice

Abstract The conductive heat flux through the snow and ice is a critical component of the mass and energy budgets in the Arctic sea ice system. We use high horizontal resolution (3–15 cm) measurements of snow topography to explore the impacts of sub-meter-scale snow surface roughness on heat flux as simulated by the Finite Element method. Simulating horizontal heat flux in a variable snow cover modestly increases the total simulated heat flux. With horizontal heat flux, as opposed to simple 1D-vertical heat flux modeling, the simulated heat flux is 10% greater than that for uniform snow with the same mean snow thickness for a 31.5 × 21 m region of sea ice (the largest region we studied). Vertical-only (1D) heat flux simulates just a 6% increase for the same region. However, this is highly dependent on observation resolution. Had we measured the snow cover at 1 m horizontal spacing or greater, simulating horizontal heat flux would not have changed the net heat flux from that simulated with vertical-only heat flux. These findings suggest that measuring and modeling snow roughness at sub-meter horizontal scales may be necessary to accurately represent horizontal heat flux on level Arctic sea ice.

Geology↗

Synergy of Satellite Radiation, Precipitation, and Other Meteorological Variable Observations for Global Mean Sea Surface Turbulent Heat Flux Estimation

Sea surface turbulent heat flux is one of the key components in global freshwater and energy balances and plays an important role in atmospheric dynamics, thermodynamics and general circulation. This turbulent heat flux is dominantly decided by sea surface latent heat release with some contribution from sensible heat exchange. The flux and its anomaly could significantly affect ocean heat storage and ocean circulation. They are part of and have great impacts on climate variability. Though the turbulent heat flux is extremely important for the climate and weather systems, only very limited ship and buoy observations of the flux are available over open oceans. There are no global, operational, direct measurements of this crucial meteorological variable. Global estimates are, basically, indirectly calculated from bulk turbulent flux parameterization with a combination of satellite column water vapor, sea surface water temperature, and wind speed observations. Critical parameters such as sea surface air temperature and humidity are estimated from empirical relations of theses variables with the water vapor and sea surface water temperature, respectively. Lacking accurate knowledge on surface air temperature and humidity, uncertainties in the parameterization and potential changes in the non-linear turbulent processes with long-term climate variations could cause large errors in estimated long-term turbulent fluxes from the indirect method as shown in current global sea surface turbulent flux datasets. This study uses synergized data of satellite global radiation, precipitation, and other meteorological variable observations to estimate sea surface turbulent heat fluxes. The radiation observations are made by the satellite Clouds and the Earth’s Radiant Energy System (CERES) sensors, while the global precipitation data is from NASA’s satellite Global Precipitation Climatology Project (GPCP). Other data includes satellite sea surface water temperature and wind speed observations. These datasets are obtained from a wide range of space sensors from passive to active instruments and from visible and near infrared to thermal infrared and microwave spectral sounders. One significant feature of these datasets is that they have multi-decades long climate records. Top-of-atmosphere (TOA) radiation and its anomaly represents the net heat energy input to the climate system, and the oceanic precipitation and ocean-land moisture transport can be used to quantify sea surface latent heat release. Based on the synergized datasets and the principle of global water and energy balances, global mean turbulent heat fluxes are estimated. The turbulent heat anomalies for the first two decades of the 21st century are, then, obtained mainly from global CERES radiation and GPCP precipitation anomalies, along with CERES derived ocean-land heat transports. Analysis indicates that the uncertainties in the estimated turbulent flux anomalies may be reduced considerably. The results suggest a strong needs in synchronized and synergized observations of atmospheric radiation, precipitation, and oceanic meteorological variables for long-term climate studies.

Bing Lin↗

Small hydrogen/oxygen rocket flowfield behavior from heat flux measurements

The mixing and heat transfer phenomena in small rocket flow fields with fuel film cooling is not well understood. An instrumented, water-cooled chamber with a gaseous hydrogen/gaseous oxygen injector was used to gather steady-state inner and outer wall temperature profiles. The chamber was tested at 414 kPa (60 psia) chamber pressure, from mixture ratios of 3.41 to 8.36. Sixty percent of the fuel was used for film cooling. These temperature profiles were used as boundary conditions in a finite element analysis program, MSC/NASTRAN, to calculate the local radial and axial heat fluxes in the chamber wall. The normal heat fluxes were then calculated and used as a diagnostic of the rocket's flow field behavior. The normal heat fluxes determined were on the order of 1.0 to 3.0 MW/meters squared (0.6 to 1.8 Btu/sec-inches squared). In the cases where mixture ratio was 5 or above, there was a sharp local heat flux maximum in the barrel section of the chamber. This local maximum seems to indicate a reduction or breakdown of the fuel film cooling layer, possibly due to increased mixing in the shear layer between the film and core flows. However, the flow was thought to be completely laminar, as the throat Reynolds numbers were below 50,000 for all the cases. The increased mixing in the shear layer in the higher mixture ratio cases appeared not to be due to the transition of the flow from laminar to turbulent, but rather due to increased reactions between the hydrogen film and oxidizer-rich core flows.

Reed, Brian D.↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Experimental and Numerical Characterization of High Heat Fluxes During Transient Blackbody Calibrations

High heat fluxes are encountered in numerous applications, such as hypersonic vehicles in flight, fires, and engines, Calibration of heat flux gages may be performed in a dual cavity cylindrical blackbody resulting in a transient calibration environment. To characterize the transient heat fluxes. experiments were performed on a dual cavity cylindrical blackbody at nominal temperatures varying from 800 C to 1900 C in increments of 100 C. Based on experiments, the optimum heat flux sensor insertion location as measured from the center partition was determined. The pre-insertion steady state axial temperature profile is compared experimentally, numerically, and analytically. The effect of convection in the blackbody cavity during the insertion is calculated and found to be less than 2 per cent. Also, an empirical correlation for predicting the emissivity of the blackbody is included. Detailed transient thermal models have been developed to simulate the heat flux calibration process at two extreme fluxes. The high (1MW/sq m) and relatively low (70 kw/sq m) fluxes are reported in this article. The transient models show the effect of inserting a heat flux gage at room temperature on the thermal equilibrium of the blackbody at 1800 C and 800 C nominal temperatures, respectively. Also, heat flux sensor outputs are derived from computed sensor temperature distributions and compared to experimental results.

Abdelmessih, Amanie N.↗

Dual Active Surface Heat Flux Gage Probe

A unique plug-type heat flux gage probe was tested in the NASA Ames Research Center 2x9 turbulent flow duct facility. The probe was fabricated by welding a miniature dual active surface heat flux gage body to the end of a hollow metal cylindrical bolt containing a metal inner tube. Cooling air flows through the inner tube, impinges onto the back of the gage body and then flows out through the annulus formed between the inner tube and the hollow bolt wall. Heat flux was generated in the duct facility with a Huels arc heater. The duct had a rectangular cross section and one wall was fabricated from 2.54 centimeter thick thermal insulation rigid surface material mounted onto an aluminum plate. To measure heat flux, the probe was inserted through the plate and insulating materials with the from of the gage located flush with the hot gas-side insulation surface. Absorbed heat fluxes measured with the probe were compared with absorbed heat fluxes measured with six water-cooled reference calorimeters. These calorimeters were located in a water-cooled metal duct wall which was located across from the probe position. Correspondence of transient and steady heat fluxes measured with the reference calorimeters and heat flux gage probe was generally within a satisfactory plus or minus 10 percent. This good correspondence was achieved even though the much cooler probe caused a large surface temperature disruption of 1000K between the metal gage and the insulation. However, this temperature disruption did not seriously effect the accuracy of the heat flux measurement. A current application for dual active surface heat flux gages is for transient and steady absorbed heat flux, surface temperature and heat transfer coefficient measurements on the surface of an oxidizer turbine inlet deflector operating in a space shuttle test bed engine.

Liebert, Curt H.↗

Heat flux sensor assembly

Heat flux sensor assembly with proviso for heat shield to reduce radiative transfer between sensor elements

Crofts, D. E.↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

ABSTRACT: Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Convective heat flux in a laser-heated thruster

An analysis is performed to estimate the convective heating to the wall in a laser-heated thruster on the basis of a solution of the laminar boundary-layer equations with variable transport properties. A local similiarity approximation is used, and it is assumed that the gas phase is in equilibrium. For the thruster described by Wu (1976), the temperature and pressure distributions along the nozzle are obtained from the core calculation. The similarity solutions and heat flux are obtained from the freestream conditions of the boundary layer, in order to determine if it is necessary to couple the boundary losses directly to the core calculation. In addition, the effects of mass injection on the convective heat transfer across the boundary layer with large density-viscosity product gradient are examined.

Wu, P. K. S.↗

Steady-State and Frequency Response of a Thin-Film Heat Flux Gauge

A new and simpler design of thin-film heat flux gauge has been developed for use In high-heat-flux environments. Heat flux gauges of the same design were fabricated on three different substrates and tested. The heat flux gauge comprises a thermopile and a thermocouple junction, which measures the surface temperature. The thermopile has 40 pairs of S-type thermocouples and is covered by two thermal resistance layers. Calibration and testing of these gauges were first carried out in an arc-lamp calibration facility. Sensitivity of the gauge was discussed in terms of the relative conductivity and surface temperature. The heat flux calculated from the gauge output was In good agreement with the precalibrated standard sensor. The steady-state and the transient response characteristics of the heat flux gauge were also investigated using a carbon dioxide pulse laser as a heat source. The dynamic frequency response was evaluated in terms of the nondimensional amplitude ratio with respect to the frequency spectrum of a chopped laser bcam. The frequency response of the gauge was determined to be about 3 kHz. The temperature profiles in the thin-film heat flux gauge were obtained numerically in steady-state conditions using FLUENT and compared with the experimental results.

Fralick, Gustave C.↗

Numerical study of the effects of boundary conditions on the measurement and calibration of gardon type heat flux sensors

To monitor the high-intensity heat flux conditions that occur in the space shuttle main engine (SSME), it is necessary to use specifically designed heat flux sensors. These sensors, which are of the Gardon-type, are exposed on the measuring face to high-intensity radiative and convective heat fluxes and on the other face to convective cooling. To improve the calibration and measurement accuracy of these gauges, researchers are studing the effect that the thermal boundary conditions have on gauge performance. In particular, they are studying how convective cooling effects the field inside the sensor and the measured heat flux. The first phase of this study involves a numerical study of these effects. Subsequent phases will involve experimental verification. A computer model of the heat transfer around a Garden-type heat flux sensor was developed. Two specific geometries are being considered are: (1) heat flux sensor mounted on a flat-plate; and (2) heat flux sensor mounted at the stagnation point of a circular cylinder. Both of these configurations are representative of the use of heat flux sensors in the components of the SSME. The purpose of the analysis is to obtain a temperature distribution as a function of the boundary conditions.

Krane, M.↗

Heat flux measuring system Patent

Heat flux sensor adapted for mounting on aircraft or spacecraft to measure aerodynamic heat flux inflow to aircraft skin

Baxter, R. D.↗

Parameterization of surface heat fluxes above forest with satellite thermal sensing and boundary-layer soundings

The paper is concerned with the feasibility of determining the surface flux of sensible heat from forest using surface temperatures measured by a satellite together with soundings of temperature aloft in the unstable atmospheric boundary layer. Consideration is also given to the effect of the spatial scale of the surface temperature measurement on the parameterization by means of the scalar roughness. The latent heat flux is derived from the sensible heat flux by means of the energy budget. The data used in the study have been obtained during the HAPEX-MOBILHY experiment of 1986. The approach is based on turbulence similarity for the unstable atmospheric boundary layer.

Brutsaert, Wilfried↗

Parameterization of surface heat fluxes above a forest with satellite thermal sensing

The authors discuss the feasibility of determining the surface flux of sensible heat from forests with surface temperatures measured by satellites together with temperature soundings in the unstable atmospheric boundary layer (ABL). The latent heat flux is derived from the sensible heat flux by means of the energy budget. The study makes use of data collected during HAPEX-MOBILHY (Hydrologic Atmospheric Pilot Experiment-Modelization du Bilan Hydrique). The methodology is based on turbulence similarity for the unstable ABL. The surface temperature data were derived from measurements by the advanced very high resolution radiometer (AVHRR) aboard the NOAA-9 satellite; the atmospheric profiles were obtained by radiosondes.

Brutsaert, Wilfried↗

Benchmark Wall Heat Flux Data for a GO2/GH2 Single Element Combustor

Wall heat flux measurements in a 1.5 in. diameter circular cross-section rocket chamber for a uni-element shear coaxial injector element operating on gaseous oxygen (GOz)/gaseous hydrogen (GH,) propellants are presented. The wall heat flux measurements were made using arrays of Gardon type heat flux gauges and coaxial thermocouple instrumentation. Wall heat flux measurements were made for two cases. For the first case, GOZ/GHz oxidizer-rich (O/F=l65) and fuel-rich preburners (O/F=1.09) integrated with the main chamber were utilized to provide vitiated hot fuel and oxidizer to the study shear coaxial injector element. For the second case, the preburners were removed and ambient temperature gaseous oxygen/gaseous hydrogen propellants were supplied to the study injector. Experiments were conducted at four chamber pressures of 750, 600, 450 and 300psia for each case. The overall mixture ratio for the preburner case was 6.6, whereas for the ambient propellant case, the mixture ratio was 6.0. Total propellant flow was nominally 0.27-0.29 Ibm/s for the 750 psia case with flowrates scaled down linearly for lower chamber pressures. The axial heat flux profile results for both the preburner and ambient propellant cases show peak heat flux levels a t axial locations between 2.0 and 3.0 in. from the injector face. The maximum heat flux level was about two times greater for the preburner case. This is attributed to the higher injector fuel-to-oxidizer momentum flux ratio that promotes mixing and higher initial propellant temperature for the preburner case which results in a shorter reaction zone. The axial heat flux profiles were also scaled with respect to the chamber pressure to the power 0.8. The results at the four chamber pressures for both cases collapsed to a single profile indicating that at least to first approximation, the basic fluid dynamic structures in the flow field are pressure independent as long as the chamber/njector/nozzle geometry and injection velocities remain the same.

Marshall, William M.↗

Thin-Film Resistance Heat-Flux Sensors

Thin-film heat-flux sensors of a proposed type would offer advantages over currently available thin-film heat flux sensors. Like a currently available thin-film heat-flux sensor, a sensor according to the proposal would be based on measurement of voltages related to the temperatures of thin metal films on the hotter and colder faces of a layer of an electrically insulating and moderately thermally conductive material. The heat flux through such a device is proportional to the difference between the temperatures and to the thermal conductivity of the layer. The advantages of the proposed sensors over the commercial ones would arise from the manner in which the temperature-related voltages would be generated and measured.

Fralick, Gustave C.↗

New heat flux model for non-axisymmetric divertor infrared structures

A convective heat flux model for perturbed plasmas, based on guiding center ion drift in vacuum elds (A. Wingen, et al., Phys. Plasmas 21 (2014) 012509), has been updated. The old model only considered ion heat flux, while here also electron heat flux is included. The updated model predicts divertor heat flux distributions in non-axisymmetric (3D) plasmas with applied Resonant Magnetic Perturbation (RMP) fields, and includes electric scalar potentials. It is found that a radial electric field in the near Scrape-o Layer (SOL) can considerably shift the footprints toroidally, leading to a smearing out eff ect of the incident heat flux, while a simple model for sheath potential has little impact on footprints. Various approaches to model electron heat flux are studied. A convective electron model, based on collisionless free streaming, is found to yield the best agreement with measurements, while a conductive model requires a at temperature gradient inside lobes to yield acceptable peak heat ux values. A heuristic heat flux layer approach, based on a fixed layer width also requires a limited heat flux inside the last closed flux surface (LCFS); by selecting various locations of the LCFS, the results of the conductive or convective model can be recovered respectively. The sum of ion and electron heat fluxes, both obtained by the convective model, is compared to experimental data for multiple time slices in DIII-D. Strike point splitting is observed with peak heat fluxes and layer widths that compare well to infrared camera (IR) measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗