Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HOSPITALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Acute Hospital Encounters in Cancer Patients Treated With Definitive Radiation Therapy

Acute hospital encounters in patients undergoing curative-intent radiation therapy (RT) have not previously been well characterized. Understanding acute visit patterns among RT patients yields insights for risk assessments and cancer urgent care clinics that could decrease hospitalization rates and reduce health care costs. This study aims to identify patient, disease-site, and treatment characteristics associated with emergency department visits and inpatient admissions in cancer patients treated with definitive RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental observation of acoustic emissions generated by a pulsed proton beam from a hospital-based clinical cyclotron

Purpose: To measure the acoustic signal generated by a pulsed proton spill from a hospital-based clinical cyclotron. Methods: An electronic function generator modulated the IBA C230 isochronous cyclotron to create a pulsed proton beam. The acoustic emissions generated by the proton beam were measured in water using a hydrophone. The acoustic measurements were repeated with increasing proton current and increasing distance between detector and beam. Results: The cyclotron generated proton spills with rise times of 18 μs and a maximum measured instantaneous proton current of 790 nA. Acoustic emissions generated by the proton energy deposition were measured to be on the order of mPa. The origin of the acoustic wave was identified as the proton beam based on the correlation between acoustic emission arrival time and distance between the hydrophone and proton beam. The acoustic frequency spectrum peaked at 10 kHz, and the acoustic pressure amplitude increased monotonically with increasing proton current. Conclusions: The authors report the first observation of acoustic emissions generated by a proton beam from a hospital-based clinical cyclotron. When modulated by an electronic function generator, the cyclotron is capable of creating proton spills with fast rise times (18 μs) and high instantaneous currents (790 nA). Measurements of the proton-generated acoustic emissions in a clinical setting may provide a method for in vivo proton range verification and patient monitoring.

60 APPLIED LIFE SCIENCES↗

LED Surgical Task Lighting Scoping Study: A Hospital Energy Alliance Project

Tungsten-halogen (halogen) lamps have traditionally been used to light surgical tasks in hospitals, even though they are in many respects ill-suited to the application due to the large percentage of radiant energy outside the visible spectrum and issues with color rendering/quality. Light-emitting diode (LED) technology offers potential for adjustable color and improved color rendition/quality, while simultaneously reducing side-effects from non-visible radiant energy. It also has the potential for significant energy savings, although this is a fairly narrow application in the larger commercial building energy use sector. Based on analysis of available products and Hospital Energy Alliance member interest, it is recommended that a product specification and field measurement procedure be developed for implementation in demonstration projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hospital Energy Benchmarking Guidance - Version 1.0

This document describes an energy benchmarking framework for hospitals. The document is organized as follows. The introduction provides a brief primer on benchmarking and its application to hospitals. The next two sections discuss special considerations including the identification of normalizing factors. The presentation of metrics is preceded by a description of the overall framework and the rationale for the grouping of metrics. Following the presentation of metrics, a high-level protocol is provided. The next section presents draft benchmarks for some metrics; benchmarks are not available for many metrics owing to a lack of data. This document ends with a list of research needs for further development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large Hospital 50% Energy Savings: Technical Support Document

This Technical Support Document documents the technical analysis and design guidance for large hospitals to achieve whole-building energy savings of at least 50% over ANSI/ASHRAE/IESNA Standard 90.1-2004 and represents a step toward determining how to provide design guidance for aggressive energy savings targets. This report documents the modeling methods used to demonstrate that the designrecommendations meet or exceed the 50% goal. EnergyPlus was used to model the predicted energy performance of the baseline and low-energy buildings to verify that 50% energy savings are achievable. Percent energy savings are based on a nominal minimally code-compliant building and whole-building, net site energy use intensity. The report defines architectural-program characteristics for typicallarge hospitals, thereby defining a prototype model; creates baseline energy models for each climate zone that are elaborations of the prototype models and are minimally compliant with Standard 90.1-2004; creates a list of energy design measures that can be applied to the prototype model to create low-energy models; uses industry feedback to strengthen inputs for baseline energy models andenergy design measures; and simulates low-energy models for each climate zone to show that when the energy design measures are applied to the prototype model, 50% energy savings (or more) are achieved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Miscellaneous and Electronic Device Energy Use in Hospitals

Miscellaneous and electronic loads (MELs) consume about one-thirdof the primary energy used in US buildings, and their energy use is increasing faster than other end-uses. In healthcare facilities, 30percent of the annual electricity was used by MELs in 2008. This paper presents methods and challenges for estimating medical MELs energy consumption along with estimates of energy use in a hospital by combining device-level metered data with inventories and usage information. An important finding is that common, small devices consume large amounts of energy in aggregate and should not be ignored when trying to address hospital energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EnergySmart Hospitals

A fact sheet describing the EnergySmart Hospitals Initiative, which supports the hospital sector in reducing energy use and costs.

commercial↗

Low Carbon Technology Strategies: Hospital

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon hospitals within their existing building portfolios. Hospitals typically include complex heating and cooling systems and specialty medical equipment.

analytics↗

Diagnostic imaging of hepatocellular carcinoma at community hospitals and their tertiary referral center in the era of LI-RADS: a quality assessment study

Purpose: To assess guideline compliance and quality of hepatocellular carcinoma, (HCC) diagnostic imaging within community hospitals (CH) and their Tertiary referral center (TRC) in a moderately high incidence region. Methods: Initial diagnostic workup CT/MRI scans of 251 patients (122 CH, 112 TRC, 17 Non-TRC academic) with HCC over a 15-month period were assessed for Liver reporting and Data System (LI-RADS) guideline compliance. 269 scans (182 CT, 87 MRI) were qualitatively evaluated by 2 independent blinded radiologists for arterial timing, overall image quality, noise and sharpness, with quantification of interobserver variability. The contrast enhancement ratio (CER) for the largest HCC on each scan was calculated using pre- and post-contrast images. Results: 103/104 (99%) of TRC and 44/78 (56%) of CH CTs adhered to LI–RADS imaging guidelines (P < 0.0001). Lack of delayed phase accounted for 32/34 (94%) of noncompliant CH CTs. Regarding MRI, 19/19 (100%) of TRC and 60/68 (88%) of CH scans were adherent (P = 0.12). For both modalities, overall image quality, noise and sharpness were rated significantly higher for TRC than CH. There was moderate interobserver agreement with intraclass correlation coefficient of 0.73, 0.70 and 0.63, respectively. Arterial-phase timing was rated adequate for CT in 75/104 TRC (72%) and 10/68 (14%) CH scans (P < 0.0001) and for MRI in 8/19 (42%) TRC and 23/68 (33%) CH scans (P = 0.17). The CER was significantly higher for TRC versus CH (2.9 vs. 1.9, P < 0.001) and MRI (0.9 vs. 0.7, P = 0.03). Conclusions: Community hospital HCC diagnostic scans significantly lag in critical quality parameters of tumor enhancement, arterial phase timing, perceived image quality, and LI-RADS CT technique compliance compared to a TRC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of changes in protective behaviors and out-of-household activities by age on COVID-19 transmission and hospitalization in Chicago, Illinois

Even with an efficacious vaccine, protective behaviors (social distancing, masking) are essential for preventing COVID-19 transmission and could become even more important if current or future variants evade immunity from vaccines or prior infection. Here we created an agent-based model representing the Chicago population and conducted experiments to determine the effects of varying adult out-of-household activities (OOHA), school reopening, and protective behaviors across age groups on COVID-19 transmission and hospitalizations. From September-November 2020, decreasing adult protective behaviors and increasing adult OOHA both substantially impacted COVID-19 outcomes; school reopening had relatively little impact when adult protective behaviors and OOHA were maintained. As of November 1, 2020, a 50% reduction in young adult (age 18-40) protective behaviors resulted in increased latent infection prevalence per 100,000 from 15.93 (IQR 6.18, 36.23) to 40.06 (IQR 14.65, 85.21)and 19.87 (IQR 6.83, 46.83) to 47.74 (IQR 18.89, 118.77) with 15% and 45% school reopening. Increasing adult (age ≥18) OOHA from 65% to 80% of pre-pandemic levels resulted in increased latent infection prevalence per 100,000 from 35.18 (IQR 13.59, 75.00) to 69.84 (IQR 33.27, 145.89) and 38.17 (IQR 15.84, 91.16) to 80.02 (IQR 30.91, 186.63) with 15% and 45% school reopening. Similar patterns were observed for hospitalizations. In areas without widespread vaccination coverage, interventions to maintain adherence to protective behaviors, particularly among younger adults and in out-of-household settings, remain a priority for preventing COVID-19 transmission.

60 APPLIED LIFE SCIENCES↗

Antiviral and clinical activity of bamlanivimab in a randomized trial of non-hospitalized adults with COVID-19

Abstract Anti-SARS-CoV-2 monoclonal antibodies are mainstay COVID-19 therapeutics. Safety, antiviral, and clinical efficacy of bamlanivimab were evaluated in the randomized controlled trial ACTIV-2/A5401. Non-hospitalized adults were randomized 1:1 within 10 days of COVID-19 symptoms to bamlanivimab or blinded-placebo in two dose-cohorts (7000 mg, n = 94; 700 mg, n = 223). No differences in bamlanivimab vs placebo were observed in the primary outcomes: proportion with undetectable nasopharyngeal SARS-CoV-2 RNA at days 3, 7, 14, 21, and 28 (risk ratio = 0.82–1.05 for 7000 mg [ p (overall) = 0.88] and 0.81–1.21 for 700 mg [ p (overall) = 0.49]), time to symptom improvement (median 21 vs 18.5 days [ p = 0.97], 7000 mg; 24 vs 20.5 days [ p = 0.08], 700 mg), or grade 3+ adverse events. However, bamlanivimab was associated with lower day 3 nasopharyngeal viral levels and faster reductions in inflammatory markers and viral decay by modeling. This study provides evidence of faster reductions in nasopharyngeal SARS-CoV-2 RNA levels but not shorter symptom durations in non-hospitalized adults with early variants of SARS-CoV-2. Trial Registration: ClinicalTrials.gov Identifier: NCT04518410.

60 APPLIED LIFE SCIENCES↗

Early initiation of prophylactic anticoagulation for prevention of coronavirus disease 2019 mortality in patients admitted to hospital in the United States: cohort study

Early initiation of prophylactic anticoagulation compared with no anticoagulation among patients admitted to hospital with covid-19 was associated with a decreased risk of 30 day mortality and no increased risk of serious bleeding events. These findings provide strong real world evidence to support guidelines recommending the use of prophylactic anticoagulation as initial treatment for patients with covid-19 on hospital admission.

59 BASIC BIOLOGICAL SCIENCES↗

Jackson Park Hospital Green Building Medical Center

Jackson Park Hospital completed the construction of a new Medical Office Building on its campus this spring. The new building construction has adopted the City of Chicago's recent focus on protecting the environment, and conserving energy and resources, with the introduction of green building codes. Located in a poor, inner city neighborhood on the South side of Chicago, Jackson Park Hospital has chosen green building strategies to help make the area a better place to live and work.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploratory Use of Microaerosol Decontamination Technology (PAEROSOL) in Enclosed, Unoccupied Hospital Setting

The goal of this study was to validate the previously observed high biological kill performance of PAEROSOL, a semi-dry, micro-aerosol decontamination technology, against common HAI in a non-human subject trial within a hospital setting of Madigan Army Medical Center (MAMC) on Joint Base Lewis-McChord in Tacoma, Washington. In addition to validating the disinfecting efficacy of PAEROSOL, the objectives of the trial included a demonstration of PAEROSOL environmental safety, (i.e., impact to hospital interior materials and electronic equipment exposed during testing) and PAEROSOL parameters optimization for future deployment.

Rainina, Evguenia I.↗

Scoping Report: Advanced Technologies for Multi-Load Washers in Hospitality and Healthcare

The purpose of this demonstration project is to quantify the energy savings and water efficiency potential of commercial laundry wastewater recycling systems and low-temperature detergent supply systems to help promote the adoption of these technologies in the commercial sector. This project will create a set of technical specifications for efficient multi-load laundry systems (both new and retrofit) tailored for specific applications and/or sectors (e.g., hospitality, health care). The specifications will be vetted with the appropriate Better Buildings Alliance (BBA) members (e.g., Commercial Real Estate Energy Alliance, Hospital Energy Alliance), finalized, published, and disseminated to enable widespread technology transfer in the industry and specifically among BBA partners.

Parker, Graham B.↗

A reproducible study design for the MIMIC-IV in-hospital mortality task

Open, tabular electronic health record (EHR) datasets such as MIMIC-III and MIMIC-IV have become critical resources for developing machine learning (ML) models addressing clinical prediction tasks, including hospital readmission, length of stay, and in-hospital mortality (IHM). While MIMIC-III has benefited from well-established preprocessing pipelines and standardized feature sets, MIMIC-IV remains comparatively challenging to work with because there are no standardized benchmarks to support reproducibility and comparability across studies. To address this limitation, we present a rigorously curated MIMIC-IV custom feature set optimized for IHM prediction, constructed through a reproducible preprocessing pipeline and feature selection strategy.

97 MATHEMATICS AND COMPUTING↗