Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIP programming”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dynamic posture analysis of Spacelab-1 crew members

Dynamic posture testing was conducted on the science crew of the Spacelab-1 mission on a single axis linear motion platform. Tests took place in pre- and post-flight sessions lasting approximately 20 min each. The pre-flight tests were widely spaced over the several months prior to the mission while the post-flight tests were conducted over the first, second, fourth, and sixth days after landing. Two of the crew members were also tested on the day of landing. Consistent with previous postural testing conducted on flight crews, these crew members were able to complete simple postural tasks to an acceptable level even in the first few hours after landing. Our tests were designed to induce dynamic postural responses using a variety of stimuli and from these responses, evaluate subtle changes in the postural control system which had occurred over the duration of the flight. Periodic sampling post-flight allowed us to observe the time course of readaptation to terrestrial life. Our observations of hip and shoulder position, when subjected to careful analysis, indicated modification of the postural response from pre- to post-flight and that demonstrable adjustments in the dynamic control of their postural systems were taking place in the first few days after flight. For transient stimuli where the platform on which they were asked to stand quickly moved a few centimeters fore or aft then stopped, ballistic or open loop 'programs' would closely characterize the response. During these responses the desired target position was not always achieved and of equal importance not always properly corrected some 15 seconds after the platform ceased to move. The persistent observation was that the subjects had a much stronger dependence on visual stabilization post-flight than pre-flight. This was best illustrated by a slow or only partial recovery to an upward posture after a transient base-of-support movement with eyes open. Postural responses to persistent wideband pseudorandom base-of-support translation were modeled as time invarient linear systems arrived at by Kalman adaptive filter techniques. Derived model parameters such as damping factor and fundamental frequency of the closed loop system showed significant modification between pre- and post-flight. This phenomenon is best characterized by movement of the poles toward increasing stability. While pre-flight data tended to show shoulders and hips moving in phase with each other, post-flight data showed a more disjoint behavior.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

On a Simplified Approach to Achieve Parallel Performance and Portability Across CPU and GPU Architectures

This paper presents software advances to easily exploit computer architectures consisting of a multi-core CPU and CPU+GPU to accelerate diverse types of high-performance computing (HPC) applications using a single code implementation. The paper describes and demonstrates the performance of the open-source C++ matrix and array (MATAR) library that uniquely offers: (1) a straightforward syntax for programming productivity, (2) usable data structures for data-oriented programming (DOP) for performance, and (3) a simple interface to the open-source C++ Kokkos library for portability and memory management across CPUs and GPUs. The portability across architectures with a single code implementation is achieved by automatically switching between diverse fine-grained parallelism backends (e.g., CUDA, HIP, OpenMP, pthreads, etc.) at compile time. The MATAR library solves many longstanding challenges associated with easily writing software that can run in parallel on any computer architecture. This work benefits projects seeking to write new C++ codes while also addressing the challenges of quickly making existing Fortran codes performant and portable over modern computer architectures with minimal syntactical changes from Fortran to C++. We demonstrate the feasibility of readily writing new C++ codes and modernizing existing codes with MATAR to be performant, parallel, and portable across diverse computer architectures.

97 MATHEMATICS AND COMPUTING↗

A Study of Performance Portability of Low-bit Fused Matrix-Vector Multiplication Kernels in SYCL

Understanding the causes of performance gaps between a portable programming model and a vendor-specific programming model is important for improving performance portability. This paper studies performance portability of low-bit fused general matrix-vector multiplication kernels in SYCL on vendors’ graphics processing units (GPUs). This work introduces the use case, explains the kernel implementations in detail, evaluates the performance of the CUDA, HIP, and SYCL kernels on datacenter, desktop, and laptop GPUs, and investigates the causes of performance gaps. The results show that loop unrolling, kernel dispatch overhead, and sum reduction contribute to the gaps.

Jin, Zheming [ORNL] (ORCID:000000027197780X)↗

Evaluation of U10Mo Fuel Plate Performance Modeling Over Hot Isostatic Press and Hydraulic Bending for MURR DDE Plates

The United States High Performance Research Reactor Program’s objective is to reduce the amount of highly enriched uranium currently implemented in research reactors. The conversion of these research reactors requires designing a monolithic U10Mo plate fuel, with the fuel plate geometry being dependent on each research reactor. The process of forming the plates includes a hot isostatic pressing (HIP) to manufacture a prototypic plate. In the case of the Missouri University Research Reactor (MURR) design demonstration element (DDE) plate manufacture, plates that have been through HIP are then curved using dies and a hydraulic press to impart the desired curvature. Both fabrication processes impart residual stresses into each fuel plate region, with the curvature of the plates taking some regions of the fuel plate up to their material yield stresses, accompanied by plastic strain. The amount of plastic strain and stress imparted onto each MURR DDE plate is determined by the radius of curvature, thickness of each region, and overall width of the fuel plates. Furthermore, this work aims to predict the yield stresses and strain using ABAQUS to simulate the proposed fabrication process of the MURR DDE plates, accompanied by discussion over the stresses and strains as to their relation to nuclear fuel performance and the impact they will have during early irradiation.

ABAQUS↗

Configuration and Projected Capabilities of the Common Habitat Medical Care Facility

The Common Habitat is a large, long-duration habitat being explored as part of a conceptual study (not an active NASA program) that uses an SLS core stage Liquid Oxygen (LOX) tank as its primary structure. It is intended for use on the Moon as part of a permanently occupied outpost, on Mars as part of an outpost that will be occupied for hundreds of days at a time, and in deep space as part of the Deep Space Exploration Vehicle where it will support crewed missions up to 1200 days in duration. A study of internal orientation and crew size resulted in a Common Habitat configuration sized for a crew of eight with a three-deck horizontal orientation. Additional work outside the scope of this paper is developing a vertical translation system, a crew mobility aids system based on wearable gecko-derived grippers, and a crew seating/restraint system. These systems are all assumed for use in conjunction with the Medical Care Facility, which is needed to maintain crew well-being during these missions, where distance from Earth precludes the possibility of evacuation to Earth. This paper describes recent improvements in the Common Habitat Medical Care Facility and associated benefits for crew survivability in long duration missions beyond Earth orbit. These improvements were made with the assistance of a NASA Pathways intern whose experience includes a tour of duty in Afghanistan as an Army combat medic with the 691st GHOST-T, attached to the 1st and 7th US Special Forces Groups as part of Operation Freedom’s Sentinel, where he helped provide far-forward surgical capabilities in austere combat environments. The initial baseline Medical Care Facility was developed working in conjunction with University of Houston Space Architecture graduate students. The facility was placed on the upper deck of the Common Habitat in a location that provided privacy, operational volume, and was close to the vertical translation pathway. The notional outfitting repurposed component CAD models from unrelated studies and notionally indicated a level of care roughly equivalent to that aboard the International Space Station. The CAD modeling provided notional stowage volumes, a deployable surface, some fixed equipment, an ultrasound, and a potentially reconfigurable treatment table. While this facility is clearly a competent arrangement, it was desired to leverage available expertise and upgrade the station given the vast distances from Earth to be experienced by the Common Habitat. Key driving requirements applied to the upgrade included to provide Medical Level of Care V, offer enhanced telemedicine capabilities, provide patient physical accommodation, provide caregiver access to the patient from all sides, include sliding pocket doors for access to hygiene and to the Vertical Translation System, and to add any additional capability possible for the best achievable medical care. The first step in the facility upgrade was to quantify the current medical inventory on the International Space Station and ensure that sufficient stowage volume was present for this purpose. To that end, the ISS medical kits were reviewed, and eight full size mid deck lockers were placed in the facility. A number of additional devices were also added, based on the intern’s combat medic experience. Also, two fixed shelves and one horizontal work surface were added to the Medical Care Facility, with the shelves providing storage space for the additional devices and the work surface providing a location for the caregiver to work or stage equipment. Four display monitors were added to the wall above the horizontal work surface, supporting data display, telemedicine, conferencing, or other needs. The existing treatment table was replaced with a mobile surgical stretcher-chair. Two additional doors were added to the Medical Care Facility. One leads directly to the hygiene compartment, allowing it to support medical operations in addition to providing galley/wardroom support. The other door leads directly into the Vertical Translation System. The wall adjacent to the subsystems bay was moved, adding additional volume to the Medical Care Facility. This improved caregiver access to the patient and allowed for a larger number of caregivers to be present. It also provided options for relocation of support equipment relative to the patient as needed. In the upgraded Medical Care Facility, the Surgical Stretcher-Chair and the Vertical Translation System can work together to provide incapacitated crew member transport from a site of injury on any deck of the Common Habitat to the Medical Care Facility. It can also support patient treatment in a variety of positions including a variety of sitting postures and a supine posture at a variety of pitch angles. The facility can also support caregiver office work for review of examination results, private consultation, inventory and maintenance, and a variety of other purposes. A forward activity will be to conduct evaluations of the Medical Care Facility with different medical scenarios. Additionally, ambient and task lighting selections remain as forward work. The eight mid deck lockers can be augmented to use as portable equipment carts, similar to a manner in which maintenance facility stowage was used as portable carts during the NASA Desert Research and Technology Studies in the Constellation Program. Trash accommodation will also need forward work to assess, including provision for wet trash, dry trash, and biological waste. It will be important to assess a redesign of the surgical stretcher-chair. The commercial version used in the upgrade can only enable vertical translation in the seated configuration, requiring the patient to bend both hips and knees. A possible redesign of the chair will allow for vertical translation without requiring any bending at the hip or knees. Also, the commercial version is wheeled, making it mobile in gravity but unanchored in microgravity. Work will be needed to adapt the chair for gravity-independent performance. The hygiene compartment can be redesigned for dual-use medical scrub and galley handwash facility. Pending sufficient volume, it may also be possible to place sanitation equipment in this location to clean medical tools. Finally, most space architectures have never allowed for more than one incapacitated crew member, but several scenarios could potentially injure two or more crew in the same incident. This facility could be assessed to determine its present ability to address two or more injured crew in parallel and determine the potential upper limit for number of treatable crew in a multi-crew injury scenario, or to treat polytrauma of a single patient.

Habitat↗

Configuration and Projected Capabilities of the Common Habitat Medical Care Facility

The Common Habitat is a large, long-duration habitat being explored as part of a conceptual study (not an active NASA program) that uses an SLS core stage Liquid Oxygen (LOX) tank as its primary structure. It is intended for use on the Moon as part of a permanently occupied outpost, on Mars as part of an outpost that will be occupied for hundreds of days at a time, and in deep space as part of the Deep Space Exploration Vehicle where it will support crewed missions up to 1200 days in duration. A study of internal orientation and crew size resulted in a Common Habitat configuration sized for a crew of eight with a three-deck horizontal orientation. Additional work outside the scope of this paper is developing a vertical translation system, a crew mobility aids system based on wearable gecko-derived grippers, and a crew seating/restraint system. These systems are all assumed for use in conjunction with the Medical Care Facility, which is needed to maintain crew well-being during these missions, where distance from Earth precludes the possibility of evacuation to Earth. This paper describes recent improvements in the Common Habitat Medical Care Facility and associated benefits for crew survivability in long duration missions beyond Earth orbit. These improvements were made with the assistance of a NASA Pathways intern whose experience includes a tour of duty in Afghanistan as an Army combat medic with the 691st GHOST-T, attached to the 1st and 7th US Special Forces Groups as part of Operation Freedom’s Sentinel, where he helped provide far-forward surgical capabilities in austere combat environments. The initial baseline Medical Care Facility was developed working in conjunction with University of Houston Space Architecture graduate students. The facility was placed on the upper deck of the Common Habitat in a location that provided privacy, operational volume, and was close to the vertical translation pathway. The notional outfitting repurposed component CAD models from unrelated studies and notionally indicated a level of care roughly equivalent to that aboard the International Space Station. The CAD modeling provided notional stowage volumes, a deployable surface, some fixed equipment, an ultrasound, and a potentially reconfigurable treatment table. While this facility is clearly a competent arrangement, it was desired to leverage available expertise and upgrade the station given the vast distances from Earth to be experienced by the Common Habitat. Key driving requirements applied to the upgrade included to provide NASA’s Medical Level of Care V, offer enhanced telemedicine capabilities, provide patient physical accommodation, provide caregiver access to the patient from all sides, include sliding pocket doors for access to hygiene and to the Vertical Translation System, and to add any additional capability possible for the best achievable medical care. The first step in the facility upgrade was to quantify the current medical inventory on the International Space Station and ensure that sufficient stowage volume was present for this purpose. To that end, the ISS medical kits were reviewed, and eight full size mid deck lockers were placed in the facility. A number of additional devices were also added, based on the co-author’s combat medic experience. Also, two fixed shelves and one horizontal work surface were added to the Medical Care Facility, with the shelves providing storage space for the additional devices and the work surface providing a location for the caregiver to work or stage equipment. Four display monitors were added to the wall above the horizontal work surface, supporting data display, telemedicine, conferencing, or other needs. The existing treatment table was replaced with a mobile surgical stretcher-chair. Two additional doors were added to the Medical Care Facility. One leads directly to the hygiene compartment, allowing it to support medical operations in addition to providing galley/wardroom support. The other door leads directly into the Vertical Translation System. The wall adjacent to the subsystems bay was moved, adding additional volume to the Medical Care Facility. This improved caregiver access to the patient and allowed for a larger number of caregivers to be present. It also provided options for relocation of support equipment relative to the patient as needed. In the upgraded Medical Care Facility, the Surgical Stretcher-Chair and the Vertical Translation System can work together to provide incapacitated crew member transport from a site of injury on any deck of the Common Habitat to the Medical Care Facility. It can also support patient treatment in a variety of positions including a variety of sitting postures and a supine posture at a variety of pitch angles. The facility can also support caregiver office work for review of examination results, private consultation, inventory and maintenance, and a variety of other purposes. A forward activity will be to conduct evaluations of the Medical Care Facility with different medical scenarios. Additionally, ambient and task lighting selections remain as forward work. The eight middeck lockers can be augmented to use as portable equipment carts, similar to a manner in which maintenance facility stowage was used as portable carts during the NASA Desert Research and Technology Studies in the Constellation Program. Trash accommodation will also need forward work to assess, including provision for wet trash, dry trash, and biological waste. It will be important to assess a redesign of the surgical stretcher-chair. The commercial version used in the upgrade can only enable vertical translation in the seated configuration, requiring the patient to bend both hips and knees. A possible redesign of the chair will allow for vertical translation without requiring any bending at the hip or knees. Also, the commercial version is wheeled, making it mobile in gravity but unanchored in microgravity. Work will be needed to adapt the chair for gravity-independent performance. The hygiene compartment can be redesigned to serve both as a medical scrub facility and for galley hand washing. Pending sufficient volume, it may also be possible to place sanitation equipment in this location to clean medical tools. Finally, most space architectures have never allowed for more than one incapacitated crew member, but several scenarios could potentially injure two or more crew in the same incident. This facility could be assessed to determine its present ability to address two or more injured crew in parallel and determine the potential upper limit for number of treatable crew in a multi-crew injury scenario, or to treat polytrauma of a single patient.

Common Habitat↗

Impact of Irradiation on Microstructure and Mechanical Properties of Materials Produced by Advanced Manufacturing

Advanced non-light water reactor designs, known as Generation IV (Gen IV) reactors, typically operate at higher temperatures and under more extreme radiation conditions than conventional light water reactors. A critical aspect of the successful deployment and advancement of Gen IV reactor designs is the selection of appropriate structural materials for specific applications, which necessitates the timely development of new materials and manufacturing processes. Advanced manufacturing (AM) offers numerous opportunities for innovative designs, enabling the production of high-performance components with potentially shorter development cycles compared to traditional manufacturing methods. However, a significant challenge in deploying AM technologies in the nuclear energy sector is the current lack of data on the irradiation performance of AM-produced components. This presentation will discuss neutron and ion irradiation results of AM materials, including stainless steel 316L, Grade 91, SA508, Inconel 718, and Inconel 625 materials. The materials were manufactured by AM, such as Powder Metallurgy Hot Isostatic Pressing (PM HIP), Laser Powder Bed Fusion (LPBF) and Directed Energy Deposition (DED). The effects of neutron irradiation on microstructure (e.g., dislocations, loops, and nanoclusters), tensile properties (e.g., strength and ductility), and ion irradiation on Irradiation-Assisted Stress Corrosion Cracking (IASCC) will be explored. Results are collected from several projects supported by the Nuclear Science User Facilities (NSUF) program.

36 - MATERIALS SCIENCE↗

Micro X-ray computed tomography examination of mini plate fuel with hot isostatic pressed aluminum cladding

In order to minimize proliferation risks and improve security of nuclear material, the United States high performance research and test reactors (USHPRR) program is tasked with converting nuclear reactors that are fueled with highly enriched uranium (HEU) fuels to operate with low-enriched uranium (LEU) nuclear fuels. One favorable LEU fuel configuration is plate fuel with a metallic uranium-molybdenum foil clad within an aluminum alloy (AA 6061). In this fuel, the aluminum cladding is bonded with a hot isostatic pressing (HIP) method to seal the cladding around the fuel meat. However, the HIP process parameters influence the cladding performance, as a defective or incomplete bond can cause a pathway for corrosion. Micro X-ray computed tomography (XCT), a nondestructive technique that provides volumetric imaging, can be applied to inspect fuel plate cladding at the engineering scale. In this work, XCT methodology was developed and successfully utilized to not only observe the bond line of unirradiated mini fuel plates, but to also identify subsurface abnormalities in the plates’ cladding. Importantly, in future work, this technique could be applied to fuel plates, pre- and post-irradiation, to quantify irradiation effects on cladding defects and bond line integrity.

36 MATERIALS SCIENCE↗

Mechanical properties of high gradient and hot isostatically pressed PWA 1480

This program has been designed to evaluate the potential benefits to alloy 1480 material properties due to high thermal gradient casting, hot isostatic pressing, and alternative heat treatment. Alloy 1480 castings have been obtained from vendors representing the extremes of commercial casting thermal gradients. Quantitative characterization of the dendrite arm spacing (DAS) and pore distributions has been conducted. A hot isostatic pressing (HIP) schedule, which avoids the many pitfalls of single crystal HIP has been devised for alloy 1480. In addition, an alternate heat treatment for alloy 1480 has been devised which provides benefits in mechanical properties. The standard gradient cast test material is being evaluated in the standard heat treat condition as a baseline and in the HIP plus alternate heat treated condition. The fhigh gradient cast material is being evaluated in alternate heat treat and HIP plus alternate heat treated conditions. Evaluations focus on demonstration of the benefits due to the applied processes, especially in the area of cyclic life.

Fritzemeier, L. G.↗

NASA Research Announcement Phase 2 Final Report for the Development of a Power Assisted Space Suit Glove

The main goal of this program was to develop an unobtrusive power-assisted EVA glove metacarpalphalangeal (MCP) joint that could provide the crew member with as close to nude body performance as possible, and to demonstrate the technology feasibility of power assisted space suit components in general. The MCP joint was selected due to its being representative of other space suit joints, such as the shoulder, hip and carpometacarpal joint, that would also greatly benefit from this technology. In order to meet this objective, a development team of highly skilled and experienced personnel was assembled. The team consisted of two main entities. The first was comprised of ILC's experienced EVA space suit glove designers, who had the responsibility of designing and fabricating a low torque MCP joint which would be compatible with power assisted technology. The second part of the team consisted of space robotics experts from the University of Maryland's Space Systems Laboratory. This team took on the responsibility of designing and building the robotics aspects of the power-assist system. Both parties addressed final system integration responsibilities.

Lingo, Robert↗

Development of Metal Boride/Carbide Precursors for MOCVD Applications

This report describes the proposed efforts for a three-year (CY23-25) program to develop refractory metal boride/carbide precursors for metal-organic chemical vapor deposition (MOCVD) applications. Reported are the CY24 results on the thermal processing of bis-cyclopentadienyl dialkyl and tetra-alkyl precursors to obtain metal carbide products. Precursors evaluated are commercially available. Materials were processed within in a custom-built MOCVD system at 1000 ⁰C, as well as in a hot isostatic press (HIP) at temperatures of 1000 ⁰C or 1650 ⁰C at pressures of 5000 psi. The products were identified as metal carbide, metal oxide, or a mixture of carbide and oxide phases depending on the starting material and process used. Density functional theory calculations were performed to determine the decomposition mechanism and to inform how ligand choice led to the products.

36 MATERIALS SCIENCE↗

Resistance exercise as a countermeasure to disuse-induced bone loss

During spaceflight, skeletal unloading results in loss of bone mineral density (BMD). This occurs primarily in the spine and lower body regions. This loss of skeletal mass could prove hazardous to astronauts on flights of long duration. In this study, intense resistance exercise was used to test whether a training regimen would prevent the loss of BMD that accompanies disuse. Nine subjects (5 men, 4 women) participated in a supine maximal resistance exercise training program during 17 wk of horizontal bed rest. These subjects were compared with 18 control subjects (13 men, 5 women) who followed the same bed rest protocol without exercise. Determination of treatment effect was based on measures of BMD, bone metabolism markers, and calcium balance obtained before, during, and after bed rest. Exercisers and controls had significantly (P < 0.05) different means, represented by the respective following percent changes: lumbar spine BMD, +3% vs. -1%; total hip BMD, +1% vs. -3%; calcaneus BMD, +1% vs. -9%; pelvis BMD, -0.5% vs. -3%; total body BMD, 0% vs. -1%; bone-specific alkaline phosphatase, +64% vs. 0%; alkaline phosphatase, +31% vs. +5%; osteocalcin, +43% vs. +10%; 1,25 dihydroxyvitamin D, +12% vs. -15%; parathyroid hormone intact molecule, +18% vs. -25%; and serum and ionized calcium, -1% vs. +1%. The difference in net calcium balance was also significant (+21 mg/day vs. -199 mg/day, exercise vs. control). The gastrocnemius and soleus muscle volumes decreased significantly in the exercise group, but the loss was significantly less than observed in the control group. The results indicate that resistance exercise had a positive treatment effect and thus might be useful as a countermeasure to prevent the deleterious skeletal changes associated with long-duration spaceflight.

Clinical Trial↗

Articulating Support for Horizontal Resistive Exercise

A versatile mechanical device provides support for a user engaged in any of a variety of resistive exercises in a substantially horizontal orientation. The unique features and versatility of the device promise to be useful in bedrest studies, rehabilitation, and specialized strength training. The device affords a capability for selectively loading and unloading of portions of the user s body through its support mechanisms, so that specific parts of the body can be trained with little or no effect on other parts that may be disabled or in the process of recovery from injury. Thus, the device is ideal for rehabilitation exercise programs prescribed by physicians and physical therapists. The capability for selective loading and support also offers potential benefits to strength and conditioning trainers and athletes who wish to selectively strengthen selected parts. The principal innovative aspect of the device is that it supports the subject s weight while enabling the subject, lying substantially horizontally, to perform an exercise that closely approximates a full standing squat. The device includes mechanisms that support the subject in such a way that the hips are free to translate both horizontally and vertically and are free to rotate about the line connecting the hips. At the same time, the shoulders are free to translate horizontally while the upper back is free to rotate about the line connecting the shoulders. Among the mechanisms for hip motion and support is a counterbalance that offsets the weight of the subject as the subject s pelvis translates horizontally and vertically and rotates the pelvis about the line connecting the hips. The counterbalance is connected to a pelvic support system that allows these pelvic movements. The subject is also supported at the shoulder by a mechanism that can tilt to provide continuous support of the upper back while allowing the rotation required for arching the back as the pelvis is displaced. The shoulder support also affords a capability for horizontal motion, and acts as the point of attachment of a load that is provided for squat and heel-raise exercises. The device is compatible with any resistive-exercise machine that provides bilateral loading via a moving cable or other mechanical linkage. The hip-translation and shoulder-translation and -rotation degrees of freedom of the supports can be locked individually or in combination in order to support the subject as necessary for exercises other than the standing squat. If necessary, for such exercises, the load can be applied directly to the subject by use of various attachments. In addition to the aforementioned heel raise, such exercises include the upright row, leg press, curls, extension of the triceps, front raise, lateral raise, and rear raise.

Gundo, Daniel↗

Evaluation of powder metallurgy superalloy disk materials

A program was conducted to develop nickel-base superalloy disk material using prealloyed powder metallurgy techniques. The program included fabrication of test specimens and subscale turbine disks from four different prealloyed powders (NASA-TRW-VIA, AF2-1DA, Mar-M-432 and MERL 80). Based on evaluation of these specimens and disks, two alloys (AF2-1DA and Mar-M-432) were selected for scale-up evaluation. Using fabricating experience gained in the subscale turbine disk effort, test specimens and full scale turbine disks were formed from the selected alloys. These specimens and disks were then subjected to a rigorous test program to evaluate their physical properties and determine their suitability for use in advanced performance turbine engines. A major objective of the program was to develop processes which would yield alloy properties that would be repeatable in producing jet engine disks from the same powder metallurgy alloys. The feasibility of manufacturing full scale gas turbine engine disks by thermomechanical processing of pre-alloyed metal powders was demonstrated. AF2-1DA was shown to possess tensile and creep-rupture properties in excess of those of Astroloy, one of the highest temperature capability disk alloys now in production. It was determined that metallographic evaluation after post-HIP elevated temperature exposure should be used to verify the effectiveness of consolidation of hot isostatically pressed billets.

Evans, D. J.↗

Risk of Bone Fracture due to Spaceflight-induced Changes to Bone

The Human Research Program (HRP) is taking a biomechanical approach to assessing subsequent fracture risk in active astronauts as a consequence of spaceflight exposure. Triennial testing of active and retired astronauts continues as Space Medicine monitors for a premature diagnosis of primary osteoporosis, which is associated with age-related bone loss and skeletal fragility. This updated 2023 Fracture Evidence Report has expanded the description of skeletal changes to capture the full effects of spaceflight on bone: • Recent analysis of fractures from health records of the full astronaut cohort, suggests an increased incidence rate of hip and spine fractures in astronauts following longer spaceflight duration flights compared to incident rates found in shorter duration flights. • Routine preflight-to-postflight surveillance by DXA (dual-energy x-ray absorptiometry) does not provide the full detection of loss and recovery in the long-duration (LD) astronaut nor the full recovery of hip trabecular bone. • The inclusion of hip quantitative computed tomography (QCT) in flight studies delineates effects of spaceflight, of countermeasures, and of post-flight recovery on cortical and trabecular bone parameters—some of which are verified predictors of hip fracture in the aged. • QCT detects and compares the distinct countermeasure effects of the pharmaceutical alendronate and of resistive exercise (on the Advanced Resistive Exercise Device, ARED) in specific cortical and trabecular bone sub-regions during spaceflight. • A published comparison of QCT-determined loss rates of hip trabecular bone in LD astronauts compared to terrestrial cohorts suggest that accelerated loss rates in trabecular volumetric BMD (vBMD) during spaceflight might be analogous to skeletal effects of accelerated loss rates in females due to menopause, potentially leading to disruptions in trabecular microarchitecture. • A dataset of finite element (FE) estimates of hip bone strength in aging terrestrial cohorts (spanning astronaut age-range) provides comparative context for changes in the FE of hip bone strength in LD astronauts, including comparison (force unit of newton) to percentiles (50th, 75th, and 100th) of sex-matched aged humans with hip fractures. • Risk of fracture, due to the mechanical overloading of bones, is being updated with IMPACT, the next-generation tool suite for probabilistic risk assessment (PRA) for exploration missions being created by the Exploration and Medical Capability Element (ExMC) at NASA. IMPACT is currently in development and will not be included in this 2024 update. The risk for fracture necessitates understanding the relationship between applied loads to bone and the biomechanical competence of bone. The Risk for Early Onset Osteoporosis focuses on the weakened condition of bone (including development of new technologies, measurements of novel skeletal attributes, translation of multiple measures to an index of bone fragility, and interpretations of data used to reflect a weakened bone), while the Risk for Fracture assesses factors that influence the probability an astronaut would encounter applied loads exceeding the biomechanical competence of bones, resulting in fracture. This Evidence Report combines the research gaps and tasks associated with both risks.

Fracture↗

Development of a gas pressure bonded four-pole alternator rotor

Methods were developed for fabrication of a solid four pole alternator rotor by hot isostatic pressure welding. The rotor blanks welded in this program had complex geometrical mating interfaces and were of considerable bulk, being approximately 3-1/2 inches (0.089 meters) in diameter and 14 inches (0.356 meters) long. Magnetic end pieces were machined from AlSl 4340 steel, while the non-magnetic central section was of Inconel 718. Excellent welds were produced which were shown to be responsive to post weld heat treatments which substantially improved joint strength. Prior to welding the rotors, test specimens of complex geometry were welded to demonstrate that complex surfaces with intentional mechanical misfit could be readily joined using HIP welding. This preliminary work demonstrated not only that interface compliance is achieved during welding but that welding pressure is developed in these thick sections sufficient to produce sound joints. Integral weld-heat treatment cycles were developed that permitted the attainment of magnetic properties while minimizing residual stress associated with the allotropic transformation of 4340 steel.

Lessmann, G. G.↗

Failure Simulation Testing of the Z-1 Spacesuit Titanium Bearing Assemblies

The Z-2 is a candidate for NASA's next generation spacesuit, designed for a range of possible missions with enhanced mobility for spacewalks both on planetary surfaces and in microgravity. Increased mobility was accomplished through innovations in shoulder and hip joints, using a number of new bearings to allow spacesuit wearers to dip, walk, and bend with ease; all important tasks for a planetary explorer collecting samples or traveling over rough terrain. The Advanced Spacesuit Development Team of NASA Johnson Space Center requested that the NASA White Sands Test Facility (WSTF) perform a series failure simulation tests on three titanium bearing assemblies, an elemental part of the joint construction used in new spacesuit designs. This testing simulated two undetected failures within the bearings and as a result the objective of this test program was to evaluate whether a failed or failing bearing could result in ignition of the titanium race material due to friction. The first failure was an inner seal leak sufficient to pressurize the race with +99 percent oxygen. The second failure was an improperly installed or mismatched ball port that created a protrusion in the ball bearing race, partially obstructing the nominal rolling path of each ball bearing. When the spacesuit bearings are assembled, bearing balls are loaded into the assembly via a ball port. The ball port is specific and unique to each bearing assembly (matched pair). The simulated mismatched ball port is a significant source of friction, which would be caused by an assembly error. To evaluate this risk, the bearings were cycled in a simulated worst-case scenario environment, with operational loads, and potential flaw conditions. During test the amount of actuation torque required and heat generated through continuous operation were measured and the bearings were observed for sparks or burning events. This paper provides detailed descriptions of the test hardware, methodology, and results.

de Baca, Richard C.↗

Portability for GPU-accelerated molecular docking applications for cloud and HPC: can portable compiler directives provide performance across all platforms?

High-throughput structure-based screening of drug-like molecules has become a common tool in biomedical research. Recently, acceleration with graphics processing units (GPUs) has provided a large performance boost for molecular docking programs. Both cloud and high-performance computing (HPC) resources have been used for large screens with molecular docking programs; while NVIDIA GPUs have dominated cloud and HPC resources, new vendors such as AMD and Intel are now entering the field, creating the problem of software portability across different GPUs. Ideally, software productivity could be maximized with portable programming models that are able to maintain high performance across architectures. While in many cases compiler directives have been used as an easy way to offload parallel regions of a CPU-based program to a GPU accelerator, they may also be an attractive programming model for providing portability across different GPU vendors, in which case the porting process may proceed in the reverse direction: from low-level, architecture-specific code to higher-level directive-based abstractions. MiniMDock is a new mini-application (miniapp) designed to capture the essential computational kernels found in molecular docking calculations, such as are used in phar-maceutical drug discovery efforts, in order to test different solutions for porting across GPU architectures. Here we extend MiniMDock to GPU offloading with OpenMP directives, and compare to performance of kernels using CUDA and HIP on NVIDIA and AMD GPUs, respectively, as well as across different compilers, exploring performance bottlenecks. We document this reverse-porting process, from highly optimized device code to a higher-level version using directives, compare code structure, and describe barriers that were overcome in this effort.

Thavappiragasam, Mathialakan↗