Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEARTBEAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Reconfigurable perovskite nickelate electronics for artificial intelligence

Reconfigurable devices offer the ability to program electronic circuits on demand. Here, in this work, we demonstrated on-demand creation of artificial neurons, synapses, and memory capacitors in post-fabricated perovskite NdNiO 3 devices that can be simply reconfigured for a specific purpose by single-shot electric pulses. The sensitivity of electronic properties of perovskite nickelates to the local distribution of hydrogen ions enabled these results. With experimental data from our memory capacitors, simulation results of a reservoir computing framework showed excellent performance for tasks such as digit recognition and classification of electrocardiogram heartbeat activity. Using our reconfigurable artificial neurons and synapses, simulated dynamic networks outperformed static networks for incremental learning scenarios. The ability to fashion the building blocks of brain-inspired computers on demand opens up new directions in adaptive networks.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ATAC-Seq Reveals an Isl1 Enhancer That Regulates Sinoatrial Node Development and Function

Cardiac pacemaker cells (PCs) in the sinoatrial node (SAN) have a distinct gene expression program that allows them to fire automatically and initiate the heartbeat. Although critical SAN transcription factors, including Isl1 (Islet-1), Tbx3 (T-box transcription factor 3), and Shox2 (short-stature homeobox protein 2), have been identified, the cis-regulatory architecture that governs PC-specific gene expression is not understood, and discrete enhancers required for gene regulation in the SAN have not been identified. Here, to define the epigenetic profile of PCs using comparative ATAC-seq (assay for transposase-accessible chromatin with sequencing) and to identify novel enhancers involved in SAN gene regulation, development, and function.

59 BASIC BIOLOGICAL SCIENCES↗

Quantifying tissue mechanical properties using photoplethysmography

Photoplethysmography (PPG) is a non-invasive optical method that can be used to detect blood volume changes in the microvascular bed of tissue. The PPG signal comprises two components; a pulsatile waveform (AC) attributed to changes in the interrogated blood volume with each heartbeat, and a slowly varying baseline (DC) combining low frequency fluctuations mainly due to respiration and sympathetic nervous system activity. In this report, we investigate the AC pulsatile waveform of the PPG pulse for ultimate use in extracting information regarding the biomechanical properties of tissue and vasculature. By analyzing the rise time of the pulse in the diastole period, we show that PPG is capable of measuring changes in the Young s Modulus of tissue mimicking phantoms with a resolution of 4 KPa in the range of 12 to 61 KPa. In addition, the shape of the pulse can potentially be used to diagnose vascular complications by differentiating upstream from downstream complications. A Windkessel model was used to model changes in the biomechanical properties of the circulation and to test the proposed concept. The modeling data confirmed the response seen in vitro and showed the same trends in the PPG rise and fall times with changes in compliance and vascular resistance.

Akl, Tony↗

Convergence of Emerging Technologies - EAGL Test Information

The Emergency Automatic Gunshot Detection and Lockdown (EAGL) system provides automatic, autonomous, and timely gunshot detection in both indoor and outdoor environments. This system uses both wired and wireless devices. Self-contained wireless EAGL sensors passively “listen” for gunshot events. These devices also perform a single, daily supervisory heartbeat (HB) function to include a device self-check with reporting capability. Transmissions are received by an assigned EAGL Gateway, which translates the RF sensor data to a PoE network format solely for use by the EAGL system server. The server then performs additional processes after data receipt, which include but are not limited to: event validation and logging, GUI presentation, notifications, and other independent operations.

47 OTHER INSTRUMENTATION↗

TIDALLY INDUCED PULSATIONS IN KEPLER ECLIPSING BINARY KIC 3230227

KIC 3230227 is a short period (P ≈ 7.0 days) eclipsing binary with a very eccentric orbit ( e = 0.6). From combined analysis of radial velocities and Kepler light curves, this system is found to be composed of two A-type stars, with masses of M {sub 1} = 1.84 ± 0.18 M {sub ⊙}, M {sub 2} = 1.73 ± 0.17 M {sub ⊙} and radii of R {sub 1} = 2.01 ± 0.09 R {sub ⊙}, R {sub 2} = 1.68 ± 0.08 R {sub ⊙} for the primary and secondary, respectively. In addition to an eclipse, the binary light curve shows a brightening and dimming near periastron, making this a somewhat rare eclipsing heartbeat star system. After removing the binary light curve model, more than 10 pulsational frequencies are present in the Fourier spectrum of the residuals, and most of them are integer multiples of the orbital frequency. These pulsations are tidally driven, and both the amplitudes and phases are in agreement with predictions from linear tidal theory for l = 2, m = −2 prograde modes.

79 ASTRONOMY AND ASTROPHYSICS↗

EKG isolator

Light beam transmits heartbeat signal from electrodes on patient to electrocardiograph without exposing patient to possible severe electrical shock. System provides complete isolation between patient and EKG instrumentation.

Palmer, E.↗

Digital cardiotachometer system Patent

Digital cardiotachometer incorporating circuit for measuring heartbeat rate of subject over predetermined portion of one minute also converting rate to beats per minute

Mitchell, V. M.↗

Cardiotachometer displays heart rate on a beat-to-beat basis

Electronics for this system may be chosen so that complete calculation and display may be accomplished in a few milliseconds, far less than even the fastest heartbeat interval. Accuracy may be increased, if desired, by using higher-frequency timing oscillator, although this will require large capacity registers at increased cost.

Rasquin, J. R.↗

Mobile automatic metabolic analyzer

Two flexible pipes, attached to face mask, are connected to spirometers in mobile cart. Inhaled air volume is measured as it is drawn from one spirometer, and exhaled air volume is measured as it is breathed into second spirometer. Sensor is used to monitor heartbeat rate.

Bynum, B. G.↗

A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.

Lund, G. F.↗

Human sinus arrhythmia as an index of vagal cardiac outflow

The human central vagal mechanisms were investigated by measuring the intervals between heartbeats during controlled breathing (at breathing intervals of 2.5-10 s and nominal tidal volumes of 1000 and 1500 ml) in six young men and women. It was found that as the breathing interval increased, the longest heart periods became longer, the shortest heart periods became shorter, and the peak-valley P-P intervals increased asymptotically. Peak-valley intervals also increased in proportion to tidal volume, although this influence was small. The phase angles between heart period changes and respiration were found to vary as linear functions of breathing interval. Heart period shortening began in inspiration at short breathing intervals and in expiration at long breathing intervals, while heart period lengthening began in early expiration at all breathing intervals studied. It is concluded that a close relationship exists between variations of respiratory depth and interval and the quantity, periodicity, and timing of vagal cardiac outflow in conscious humans. The results indicate that at usual breathing rates, phasic respiration-related changes of vagal motoneuron activity begin in expiration, progress slowly, and are incompletely expressed at fast breathing ratges.

Eckberg, D. L.↗

Transducers For Heat Research

Series of transducers with seven different configurations enable measurement of forces and displacements in heart wall. New transducers small, cause minimal perturbation of heart function and attached and detached without causing excessive tissue damage. All units implanted or removed during single heartbeat, permitting rapid relocation for detail mapping.

Feldstein, C.↗

Amplitude distributions of the spider heartpulse in response to gravitational stimuli

The arachnid Nuctenea sclopetaria (Clerck) which possesses a neurogenic heart, measuring the heartbeat is under efferent control through a dorsal nerve arising from a brain center is discussed. It was shown that the heartrate of this spider is also modulated by an afferent input associated with small increments of gravity. A compressive force on the order of 40 micron is sufficient to elicit a threshold change in heart rate for a typical (100mg) spider. This obtains in a hyper-Gz field less than 1.001. The functional relationship between gravity and heartrate is logarithmic between the absolute threshold and at least 1.5 Gz. A model was proposed in which equilibrium and movement are maintained by changes in blood pressure. It is concluded that the arachnid equilibrium system is like a weight detector which employs a hydraulic compensatory mechanism.

Finck, A.↗

A simple electrical-mechanical model of the heart applied to the study of electrical-mechanical alternans

Recent evidence has shown that a subtle alternation in the surface ECG (electrical alternans) may be correlated with the susceptibility to ventricular fibrillation. In the present work, the author presents evidence that a mechanical alternation in the heartbeat (mechanical alternans) generally accompanies electrical alternans. A simple finite-element computer model which emulates both the electrical and the mechanical activity of the heart is presented. A pilot animal study is also reported. The computer model and the animal study both found that (1) there exists a regime of combined electrical-mechanical alternans during the transition from a normal rhythm towards a fibrillatory rhythm, (2) the detected degree of alternation is correlated with the relative instability of the rhythm, and (3) the electrical and mechanical alternans may result from a dispersion in local electrical properties leading to a spatial-temporal alternation in the electrical conduction process.

Clancy, Edward A.↗

Implantable Heart Aid

CPI's human-implantable automatic implantable defibrillator (AID) is a heart assist system, derived from NASA's space circuitry technology, that can prevent erratic heart action known as arrhythmias. Implanted AID, consisting of microcomputer power source and two electrodes for sensing heart activity, recognizes onset of ventricular fibrillation (VF) and delivers corrective electrical countershock to restore rhythmic heartbeat.

Source record↗

Implantable Heart Aid

Medrad utilized NASA's Apollo technology to develop a new device called the AID implantable automatic pulse generator which monitors the heart continuously, recognizes the onset of ventricular fibrillation and delivers a corrective electrical shock. AID pulse generator is, in effect, a miniaturized version of the defibrillator used by emergency squads and hospitals to restore rhythmic heartbeat after fibrillation, but has the unique advantage of being permanently available to the patient at risk. Once implanted, it needs no specially trained personnel or additional equipment. AID system consists of a microcomputer, a power source and two electrodes which sense heart activity.

Source record↗

The Pascal Mars Scout Mission

Except for Earth, Mars is the planet most amenable to surface-based climate studies. Its surface is accessible, and the kind of observations that are needed, such as meteorological measurements from a long-lived global network, are readily achievable. Weather controls the movement of dust, the exchange of water between the surface and atmosphere, and the cycling of CO2 between the poles. We know there is a weather signal, we know how to measure it, and we know how to interpret it. Pascal seeks to understand the long-term global behavior of near-surface weather systems on Mars, how they interact with its surface, and, therefore, how they control its climate system. To achieve this, Pascal delivers 18 Science Stations to the surface of the planet that operate for three Mars years (5.6 Earth years). The network has stations operating in the tropics, midlatitudes, and polar regions of both hemispheres. During entry, descent, and landing, each Pascal probe acquires deceleration measurements to determine thermal structure, and descent images to characterize local terrain. On the surface, each Science Station takes daily measurements of pressure, opacity, temperature, wind speed, and water vapor concentration and monthly panoramic images of the landing environment. These data will characterize the planet's climate system and how atmosphere-surface interactions control it. The Pascal mission is named after 17th century French Scientist, Blaise Pascal, who pioneered measurements of atmospheric pressure. Pressure is the most critical measurement because it records the "heartbeat" of the planet's general circulation and climate system.

Haberle, R. M.↗