Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “H- source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Incremental performance improvements for a surface-convergency H- ion source

We discuss some of the interventions on LANSCE's surface-conversion negative-hydrogen ion sources to increase reliability; lifetime and output without any major re-design of the machine. LANSCE's source presently delivers a baseline 16 mA, 60 Hz, 12% duty factor beam. We describe how better quality control and processing of tungsten filaments allow the comfortable completion of 28-day run cycles, how improved temperature control of the ion source body yields an increased H{sup -} output, how higher input power through an additional filament allows operations at plasma densities while maintaining the filament lifetime and how adequate electrode biasing inside the source provide some control over the beam Twiss parameters on exit.

43 PARTICLE ACCELERATORS↗

RF H- Ion Source with Saddle Antenna

In this project we are developing an RF H- surface plasma source (SPS) which will synthesize the most important developments in the field of negative ion sources to provide high pulsed and average current, higher brightness, longer lifetime and higher reliability by improving a power efficiency. Several versions of new plasma generators with different antennas and magnetic field configurations were tested in a small AlN test chamber in the SNS ion source Test Stand. Then a prototype saddle antenna was installed in the Test Stand with a larger, normal-sized SNS AlN chamber that achieved a peak current of 67 mA and an apparent efficiency of 1.6 mA/kW. These values are comparable to those of the present SNS sources and can be expected to be improved when the prototype is developed into an operational version in the next phase of the project.

43 PARTICLE ACCELERATORS↗

H- Ion Source Development for the FNAL 750keV Injector Upgrade

The new FNAL 750keV injector upgrade for the replacement of the 40 year old Fermi National Laboratory (FNAL) Cockcroft-Walton accelerators with a new ion source and 200MHz Radio Frequency Quadrupole (RFQ), Low Energy Beam Transport (LEBT) and Medium Energy Beam Transport (MEBT) [1], has been built and is now being tested prior to installation during the 2012 shutdown. The new H-' ion source is a round aperture magnetron which was developed at Brookhaven National Lab (BNL) by Jim Alessi[2]. Operational experience from BNL has shown that this type of source is more reliable with a longer lifetime (on the order of 6 to 9 months) due to better power efficiency. With a similar duty factor to BNL, we expect to have a comparable lifetime between source changes. The new source design reliably produces 90mA of H-' beam current at 15Hz rep-rate, 250mus pulse width, and a duty factor of 0.38%A The measured emittances at the end of the LEBT are horizontally H = 0.21I mm- mrad and vertically V = 0.17I mm- mrad. With 35kV extraction the power efficiency is 60mA/kW. The source design, along with data from a test stand and the LEBT, will be presented in this paper.

43 PARTICLE ACCELERATORS↗

Commissioning of the new H{sup -} source for Linac4

As part of the CERN accelerator complex upgrade, a new linear accelerator for H{sup -} (Linac4) will start its operation in 2014. The source for this linac will be a 2 MHz rf driven H{sup -} source which is a copy of the very successful source from DESY. In this paper the design and the first results of the commissioning are reported. The commissioning has progressed successfully, and no major obstacles have been identified which will prevent reaching the goal of 80 mA H{sup -} beam current, 45 keV beam energy, 0.4 ms pulse length, and 2 Hz repetition rate. The source is producing up until now a stable beam of 23 mA, 35 keV, and with a repetition rate of 0.83 Hz.

43 PARTICLE ACCELERATORS↗

Tests of Cs-Free Operation of the SNS RF H⁻ Ion Sources

Tests were performed at SNS in collaboration with visiting colleagues from ISIS, UK to evaluate the uncesiated beam performance of the SNS RF H⁻ ion sources. Two spare experimental sources, one with internal antenna and one with external antenna were used for the tests. The beam currents achieved with Cs-free operations accounted for about 1/3 to 1/2 of the beam currents produced with cesiated operations. ~17 mA uncesiated H⁻ current was demonstrated within the tested RF power range up to 65 kW with the internal antenna source and ~15 mA with up to 40 kW RF with the external antenna source. In Cs-free operations, the power supply for the electron dumping electrode was loaded down below its set voltage but was not too drastic to tamper the operation.

Han, Baoxi↗

Recent Performance of the SNS H- ion source and low-energy beam transport system

Recent measurements of the H beam current show that SNS is injecting about 55 mA into the RFQ compared to 45 mA in 2010. Since 2010, the H beam exiting the RFQ dropped from 40 mA to 34 mA, which is sufficient for 1 MW of beam power. To minimize the impact of the RFQ degradation, the service cycle of the best performing source was extended to 6 weeks. The only degradation is fluctuations in the electron dump voltage towards the end of some service cycles, a problem that is being investigated. Very recently, the RFQ was retuned, which partly restored its transmission. In addition, the electrostatic low-energy beam transport system was reengineered to double its heat sinking and equipped with a thermocouple that monitors the temperature of the ground electrode between the two Einzel lenses. The recorded data show that emissions from the source at high voltage dominate the heat load. Emissions from the partly Cs-covered first lens cause the temperature to peak several hours after starting up. On rare occasions, the temperature can also peak due to corona discharges between the center ground electrode and one of the lenses.

H- source↗

The RHIC Polarized H{sup -} Source

The depolarization factors in the multi-step spin-transfer polarization technique and basic limitations on maximum polarization in the Optically-Pumped Polarized H- Ion Source (OPPIS) are discussed. Results of simulations and experimental studies of the Sona-transition polarization transfer process are presented. The experimentally observed polarization oscillations and polarization maximum peak were reproduced in simulations. Detailed studies of polarization losses in the RHIC OPPIS and the source parameters optimization resulted in the OPPIS polarization increase to 86-90%. This contributed to increasing polarization in the AGS and RHIC to 65approx70%.

43 PARTICLE ACCELERATORS↗

Performance of the H- Ion Source Supporting 1-MW Beam Operations at SNS

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory reached 1-MW of beam power in September 2009, and now routinely operates near 1-MW for the production of neutrons. This paper reviews the performance, operational issues, implemented and planned mitigations of the SNS H- ion source to support such high power-level beams with high availability. Some results from R&D activities are also briefly described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Next Generation H- Ion Sources for the SNS

The U.S. Spallation Neutron Source (SNS) is the leading accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure meeting operational requirements as well as providing for future facility beam power upgrades, a multifaceted H{sup -} ion source development program is ongoing. This work discusses several aspects of this program, specifically the design and first beam measurements of an RF-driven, external antenna H{sup -} ion source based on an AlN ceramic plasma chamber, elemental and chromate Cs-systems, and plasma ignition gun. Unanalyzed beam currents of up to {approx}100 mA (60Hz, 1ms) have been observed and sustained currents >60 mA (60Hz, 1ms) have been demonstrated on the test stand. Accelerated beam currents of {approx}40 mA have also been demonstrated into the SNS front end. Data are also presented describing the first H{sup -} beam extraction experiments from a helicon plasma generator based on the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) engine design.

33 ADVANCED PROPULSION SYSTEMS↗

DEVELOPMENT OF THE SNS EXTERNAL ANTENNA H- ION SOURCE

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility currently in the process of ramping up neutron production. To meet present and future beam current and reliability requirements we are developing an RF-driven, H- ion source based on a ceramic aluminium nitride (AlN) plasma chamber surrounded by an external RF antenna. This report recounts the design of the prototype source, describes the Cs collar variations tested, enumerates recent modifications made to the source to prepare a production version, and summarizes the results of runs on the SNS test stand and Front End (FE) of the SNS accelerator. Up to ~100 mA unanalyzed beam currents (60Hz, 1ms) have been measured on the SNS ion source test stand, and up to 42mA have been successfully accelerated by the RFQ on the SNS front-end at lower RF power.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

H- Ion Sources for High Intensity Proton Drivers

Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H + and H - ion generation around 3 to 5 mA/cm 2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm 2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

43 PARTICLE ACCELERATORS↗

The SNS External Antenna H- Ion Source

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure that we will meet our operational commitments as well as provide for future facility upgrades with high reliability, we have developed an RF-driven, H- ion source based on a ceramic aluminum nitride (AlN) plasma chamber [1]. This source is expected to be utilized by the SNS for neutron production starting in 2009. This report details the design of the production source which features an AlN plasma chamber, 2-layer external antenna, cooled-multicusp magnet array, Cs2CrO4 cesium system and a Molybdenum plasma ignition gun. Performance of the production source both on the SNS accelerator and SNS test stand is reported. The source has also been designed to accommodate an elemental Cs system with an external reservoir which has demonstrated unanalyzed beam currents up to ~100mA (60Hz, 1ms) on the SNS ion source test stand.

43 PARTICLE ACCELERATORS↗

THE CONTINUED DEVELOPMENT OF THE SNS EXTERNAL ANTENNA H- ION SOURCE

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure that the SNS will meet operational commitments as well as provide for future facility upgrades with high reliability, we are developing an RF-driven, H- ion source based on a water-cooled, ceramic aluminum nitride (AlN) plasma chamber. To date, early versions of this source has delivered up to 42 mA to the SNS Front End (FE) and unanalyzed beam currents up to ~ 100mA (60Hz, 1ms) to the ion source test stand. This source was operated on the SNS accelerator from February to April 2009 and produced ~35mA (beam current required by the ramp up plan) with availability of ~97%. During this run several ion source failures identified reliability issues which must be addressed before the source re-enters routine operation: plasma ignition, antenna lifetime, magnet cooling and cooling jacket integrity. This report discusses these issues, details proposed engineering solutions and notes progress to date.

43 PARTICLE ACCELERATORS↗

Lifetime of the Highly Efficient H- Ion Sources

Factors limiting the operating lifetime of Compact Surface Plasma Sources (CSPS) are analyzed and possible treatments for lifetime enhancement are considered. Noiseless discharges with lower gas and cesium densities are produced in experiments with modified discharge cells. With these discharge cells it is possible to increase the emission aperture and extract the same beam with a lower discharge current and with correspondingly increased source lifetime. A design of an advanced CSPS is presented. Optimization of the discharge cells in a Penning H{sup -} ion source is a viable method for increasing the phase space of the stable region for noiseless discharge production. With this method, cesium usage would be decreased, potentially resulting in longer source lifetimes.

43 PARTICLE ACCELERATORS↗

Detailed beam and plasma measurements on the vessel for extraction and source plasma analyses (VESPA) Penning H{sup −} ion source

A vessel for extraction and source plasma analyses (VESPA) is operational at the Rutherford Appleton Laboratory (RAL). This project supports and guides the overall ion source R&D effort for the ISIS spallation neutron and muon facility at RAL. The VESPA produces 100 mA of pulsed H{sup −} beam, but perveance scans indicate that the source is production-limited at extraction voltages above 12 kV unless the arc current is increased. A high resolution optical monochromator is used to measure plasma properties using argon as a diagnostic gas. The atomic hydrogen temperature increases linearly with arc current, up to 2.8 eV for 50 A; whereas the electron temperature has a slight linear decrease toward 2.2 eV. The gas density is 10{sup 21} m{sup −3}, whilst the electron density is two orders of magnitude lower. Densities follow square root relationships with arc current, with gas density decreasing whilst electron (and hence ion) density increases. Stopping and range of ions in matter calculations prove that operating a high current arc with an argon admixture is extremely difficult because cathode-coated cesium is heavily sputtered by argon.

43 PARTICLE ACCELERATORS↗

A compact high-resolution X-ray ion mobility spectrometer

For the ionization of gaseous samples, most ion mobility spectrometers employ radioactive ionization sources, e.g., containing {sup 63}Ni or {sup 3}H. Besides legal restrictions, radioactive materials have the disadvantage of a constant radiation with predetermined intensity. In this work, we replaced the {sup 3}H source of our previously described high-resolution ion mobility spectrometer with 75 mm drift tube length with a commercially available X-ray source. It is shown that the current configuration maintains the resolving power of R = 100 which was reported for the original setup containing a {sup 3}H source. The main advantage of an X-ray source is that the intensity of the radiation can be adjusted by varying its operating parameters, i.e., filament current and acceleration voltage. At the expense of reduced resolving power, the sensitivity of the setup can be increased by increasing the activity of the source. Therefore, the performance of the setup can be adjusted to the specific requirements of any application. To investigate the relation between operating parameters of the X-Ray source and the performance of the ion mobility spectrometer, parametric studies of filament current and acceleration voltage are performed and the influence on resolving power, peak height, and noise is analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The microwave and H-alpha sources of the 1992 January 13 flare

We compare X-ray, microwave and H-alpha observations for the 1992 January 13 limb flare. The soft and hard X-ray images of the flare have been studied thoroughly by Masuda et al. (1994) with Yohkoh SXT and HXT images. We find that during the hard X-ray emission peak there is no H-alpha brightening on the disk nor at the limb, so the main ribbons of this flare must be beyond the limb. The microwave source maintains a fixed distance about 10 arcsecs from the optical limb in the frequency range 2.8-14.0 GHz. We interpret this limit in source position as due to the presence of a microwave limb that extends higher than the white-light limb -- to a height of 7300 +/- 1500 km. We believe that the high-frequency microwave emissions are occulted by this extended limb, while the soft and hard X-ray emissions are able to pass through largely unaffected. We also believe, however, that the hard X-ray footpoints are also partially occulted by the photospheric limb, despite the appearance of 'footpoint sources' in HXT data shown by Masuda et al. The smooth X-ray and microwave time profiles, microwave-rich emission relative to hard X-rays, and progressive hard X-ray spectral hardening through the flare peak are all characteristics that we interpret as being a direct result of the occultation of footpoint emission.

Wang, H.↗