Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid services”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Data-based Aggregate Model of Refrigerators for Electric Power Grid Services

Electrical power system stability under high penetration of intermittent renewable energy generation, such as wind and solar energy, has become a high concern. It is unpredictable and hard to control due to little inertial behavior characteristic to these generation resources. To help mitigate possibly undesirable frequency excursions, demand-side frequency control presents an emerging solution. By observing the frequency deviation, devices could switch operating modes for a short time to rebalance generation. To analyze device level control algorithms, aggregate models for their behavior are needed. Refrigerators are household devices that could help with load modulation. This paper uses real measured data to analyze the refrigerator behavior, learn about its operating mode and power consumption ranges. A Markov chain process is proposed to model the transition of a refrigerator population from one operating mode to another, such that the overall load is modulated according to the control input. The Markov-chain model can be used to design control so that the overall load is modulated according to the control input.

Markov chain model, demand response, refrigerator,↗

Grid Services Load Shift Baseline Degradation Analysis Methodology v1

As demand flexibility becomes more common, the mix and frequency of a range of demand flexibility strategies will introduce potential biases into baselines, i.e., the time period immediately prior to a LS event may include other LS or DF events. Baseline degradation assessment provides an approach to quantify how these biases begin to compromise predictive accuracy. Heatmaps, based on each month of the year provides a granular view of a given model's predictive capability. However, for comparing multiple algorithms, separately for weekdays and weekends, aggregating results to seasons provides a simpler means of comparison while still allowing for review of variations by time of day and time of year

Fernandes, Samuel↗

Beyond DERMS: Demonstration of Automated Grid Services, Mode Transition, and Resilience

This report describes the results of more advanced use cases including Ancillary Services, Black-sky-day operation, and Mode Switching from Phase 3 of the “Beyond DERMS” project aiming to build, deploy, and demonstrate a holistic platform that supports the integrated operation and planning of future power distribution networks with bi-directional power flows, many diverse distributed energy resources (DERs), and inverter-based resources. These test results demonstrated how a Beyond DERMS platform can fuse together AMI, SCADA, and DER data to provide a utility with deep insights into distribution network operations and planning, extending the value of DERMS and BTM DER resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Efficiency Analysis and Grid Service Results for Commercial Buildings using the VOLTRON IoT Platform

In fiscal year 2021 (FY21), the Commercial Buildings Integration Program (CBI) within the Building Technologies Office (BTO), funded PNNL to conduct a field evaluation of the AIRCx and ILC using an Internet-of-Things (IoT) platform, VOLTTRON. The primary goal of the project is to show that software solutions deployed and delivered through an IoT-platform can identify energy efficiency opportunities and manage peak load (beyond the traditional demand response) in commercial buildings. There are also two secondary goals: 1) show that the energy efficiency solutions will result in identification of significant savings opportunities (10% to 30%) as well as energy cost reductions (10% to 15%) by managing the peak load in commercial buildings, and 2) show that an IoT-based software solution is more cost-effective compared to a manual process in meeting the Re-tuning/retro commissioning (RCx) mandates and there is a pathway for broader adoption of this approach. This report provides AIRCx and ILC results for two building located in District of Columbia managed by the energy service provider Intellimation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Delivering Energy Efficiency and Grid Services for Commercial Buildings on an IoT-Platform: Field Evaluation Plan

In FY20, the Commercial Buildings Integration Program (CBI) within Building Technologies Office (BTO) has funded PNNL to conduct field evaluation of the AIRCx and intelligent load control (ILC) using an Internet-of-Things (IoT) platform, VOLTTRON. The primary goal of the project is to show that software solutions deployed and delivered through an IoT-platform can identify energy efficiency opportunities and manage peak load in commercial buildings. There are also two secondary goals: 1) show that the energy efficiency solutions will result in identification of significant savings (10% to 30%) opportunities as well as energy cost reductions (10% to 15%) by managing the peak load in commercial buildings, and 2) show that an IoT-based software solution is more cost-effective in meeting the Re-tuning mandates than traditional retro commissioning (RCx) and there is a pathway for broader adoption of this approach. This report details how the field evaluation will be conducted, including what enhancements will be made to the software technologies, how PNNL will recruit energy service providers, types of buildings where the technology will be evaluated, metric of success for the field evaluation, and how the metric of success will be measured.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Evaluation of Cyber-Attacks on Grid-Interactive Efficient Buildings

Grid-interactive efficient buildings (GEBs) are not only exposed to passive threats (e.g., physical faults) but also active threats such as cyber-attacks launched on the network-based control systems. The impact of cyber-attacks on GEB operation are not yet fully understood, especially as regards the performance of grid services. To quantify the consequences of cyber-attacks on GEBs, this paper proposes a modeling and simulation framework that includes different cyber-attack models and key performance indexes to quantify the performance of GEB operation under cyber-attacks. The framework is numerically demonstrated to model and evaluate cyber-attacks such as data intrusion attacks and Denial-of-Service attacks on a typical medium-sized office building that uses the BACnet/IP protocol for communication networks. Simulation results show that, while different types of attacks could compromise the building systems to different extents, attacks via the remote control of a chiller yield the most significant consequences on a building system’s operation, including both the building service and the grid service. It is also noted that a cyber-attack impacts the building systems during the attack period as well as the post-attack period, which suggests that both periods should be considered to fully evaluate the consequences of a cyber-attack.

Fu, Yanyang↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

advanced metering infrastructure (AMI)↗

Commercialization of Distribution System Load Modeling Tool for Improved DER Interconnection Studies

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

14 SOLAR ENERGY↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation and the results have proved the effectiveness of this method.

AMI↗

Evaluating the Risk of Enabling Energy Storage Systems to Provide Multiple Services

Battery energy storage systems (BESS) are emerging as a promising, versatile technology for modern power grids due to their inherent distributed nature, their ability to inject bidirectional power flows and to provide multiple grid services. With the proliferation of intermittent renewable energy resources, the BESS procurement is also expected to increase, thereby creating systematic and strategic opportunities for BESS to various revenue streams for providing multiple grid services. Utilizing a co-simulation architecture, this work presents evaluation framework for enabling Utility-scale BESS with simultaneous provision of multiple services. The proposed framework is implemented on a real-life feeder modeled in GridLAB-D, leveraging multi-service grid support. A Risk-Aware control strategy is also implemented in this work that that takes into account the uncertain nature of some of the stochastic services and ensures the BESS to deliver their service commitments. This promotes overall grid reliability and encourages BESS implementation through the revenue streams from providing multiple grid services.

Theisen, John↗

A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset

This project developed a publicly available, high-fidelity dataset about the interactions among humans, homes, and heat pumps supporting grid interactive efficient buildings to balance demand on the grid with comfort for occupants. Laboratory measurements and simulations of the hardware capture the second-scale electric power dynamics of heat pumps providing grid services like load shifting and load shedding. Field measurements, behavior tracking, and qualitative surveys of people in their homes over multiple years—including experimentally adjusting the heating and cooling system to provide grid services—to capture the reciprocal effect of human behavior on grid services, and grid services on human comfort. Taken together, these data capture the complete Hardware and Human in the loop system for residential heat pumps, reducing large uncertainties in simulation for design, and models for control of heat pumps, and grid-interactive buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid ancillary services using electrolyzer-Based power-to-Gas systems with increasing renewable penetration

Increasing penetrations of renewable-based generation have led to a decrease in the bulk power system inertia and an increase in intermittency and uncertainty in generation. Energy storage is considered to be an important factor to help manage renewable energy generation at greater penetrations. Hydrogen is a viable long-term storage alternative. This paper analyzes and presents use cases for leveraging electrolyzer-based power-to-gas systems for electric grid support. The paper also discusses some grid services that may favor the use of hydrogen-based storage over other forms such as battery energy storage. Real-time controls are developed, implemented and demonstrated using a power-hardware-in-the-loop(PHIL) setup with a 225-kW proton-exchange-membrane electrolyzer stack. These controls demonstrate frequency and voltage support for the grid for different levels of renewable penetration (0%, 25%, and 50%). A comparison of the results shows the changes in respective frequencies and voltages as seen as different buses as a result of support from the electrolyzers and notes the impact on hydrogen production as a result of grid support. Finally, the paper discusses the practical nuances of implementing the tests with physical hardware, such as inverter/electrolyzer efficiency, as well as the related constraints and opportunities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters

Smart inverters (SIs) have demonstrated their potential to provide grid services for both transmission and distribution systems. One of these grid services, distribution network voltage regulation by SIs, has the potential to improve network voltage regulation through controlling the reactive and active power output of the SIs. Voltage regulation by SIs will be distributed and might be better suited to controlling local conditions to complement traditional voltage-regulating assets, e.g., tap-changing transformers, capacitor banks, and line voltage regulators. There is a gap in the literature on comparing the SI response characteristics when the SIs are controlled by a local controller or external control signals. This paper presents an experimental study to characterize SI reactive power regulation responses to two different control methods: autonomous control and remote dispatch. We found that SI reactive power regulation responses exhibit important differences between these methods in terms of delays and ramp rate. Finally, power-hardware-in-the-loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL test results show that the SI response characteristics for autonomous control and remote dispatch need to be considered when planning for distribution network voltage regulation using SIs.

autonomous control↗