Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

(DG)2 (Distributed Generation for Distribution Grids) [SWR-18-63]

(DG)2 is an impact analysis tool for electrical utilities to perform spatio-temporal analysis with solar and battery energy storage systems. The purpose of the tool is to help distribution utilities with identifying impacts and costs associated with locating a MW-scale solar farm and energy storage system at a certain location over other choices. This tool also assists utilities to assess the amount of reverse power flow at the transmission lines.

Latif, Aadil↗

Technical Bulletin 005: NTP Monitoring

The Center for Alternative Synchronization and Timing (CAST) views Precision Time Protocol (PTP) and Network Time Protocol (NTP) as critical elements of the grid, from generation to the grid edge. This tech bulletin discusses the operation of NTP. The document shows not only commercial but also open-source applications. In some cases, the commercial applications may already have existing feature sets to secure and monitor NTP streams. From a security standpoint, using subscription NTP is risky unless the open bidirectional ports on local firewalls and routers are properly monitored and controlled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electric Grid Visualization: Hourly Generation, Load, Unserved Load, and Locational Marginal Prices during a 2018 Heatwave

Visualization of hourly generation, load, unserved load, and locational marginal energy prices in the western United States during a July 22-28 heatwave event in 2018. In addition to hourly time series data of each of the parameters, choropleth maps showing the hourly value for each balancing authority are provided as well as a county-level choropleth map of temperature.

Mongird, Kendall (ORCID:0000000328077088)↗

Residual estimation for grid modification in wall-modeled large eddy simulation using unstructured high-order methods

Here, the accuracy and computational cost of a large eddy simulation are highly dependent on the computational grid. Building optimal grids manually from a priori knowledge is not feasible in most practical use cases; instead, solution-adaptive strategies can provide a robust and cost-efficient method to generate a grid with the desired accuracy. We adapt the residual estimation algorithm developed by Toosi and Larsson for Discontinuous Galerkin Spectral Elements Methods (DGSEM) to guide the grid-adaptation process. The core of the method is the computation of the estimated modeling residual using the polynomial basis functions used in DGSEM, and the averaging of the estimated residual over each element. The final method is assessed in multiple channel flow test cases and for the transonic flow over an airfoil, in both cases making use of mortar interfaces between elements with hanging nodes. The method is found to be robust and reliable, and to provide solutions on grids with significantly fewer elements at comparable accuracy compared to when using human-generated grids.

97 MATHEMATICS AND COMPUTING↗

Providing Ancillary Services with Photovoltaic Generation in Multi-Timescale Grid Operation: Preprint

With photovoltaic (PV) generation substantially increases, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV generation. On the one hand, the increase of PV generation necessitates the needs of more flexible resources. On the other hand, PV generation, because of its low operation cost, has been replacing the conventional generation in the system which is the main flexible resources in the current system. Consequently, there is a trend to require the renewable generation including PV to provide flexible ancillary services to further accommodate more PV integration. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. It shows that not only the system reliability but also PV's profitability can be improved with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Coordinated Frequency Regulation in Grid-Forming Storage Network via Safety-Consensus

Inverter-based storages are poised to play a prominent role in future power grid with massive renewable generation. Grid-forming inverters (GFMs) are emerging as a dominant technology with synchronous generators (SG)-like characteristics through primary control loops. Advanced secondary-layer control schemes, e.g., consensus algorithms, allow GFM-interfaced storage units to participate in frequency regulations and restore nominal frequency following grid disturbances. However, it is imperative to ensure critical frequency safety limits are not violated while the grid transitions from pre- to post-disturbance operating point. This paper presents a novel safety-enforced consensus method, having three distinct objectives: safe transient frequency evolution, minimizing frequency deviation, and coordinated power sharing. The proposed technique is illustrated using a GFM-interfaced grid-wide storage network on the IEEE 68-bus system under multiple grid transient scenarios.

consensus control↗

High-Fidelity Dataset Generation for Sensor Anomalies in Power Grids using Hardware-in-the-Loop Testbed

Sensor anomalies in power grids can have significant impacts on the operation of the grid due to the increased reliance of the grid operation on data-driven applications. However, there is a lack of datasets that accurately capture these anomalies as many of the anomalies go undetected using the current bad data detectors. High-fidelity labeled datasets are essential for developing robust applications that can detect and mitigate the impacts of anomalies. In this paper, we propose a hardware-in-the-loop testbed model that can emulate the grid behavior with high-fidelity. This testbed is used to inject anomalies at various levels in the grid architecture and generate labeled datasets. These high-fidelity datasets can be used for development and validation of data-driven applications for detection and mitigation of anomalies in grids and other cyber-physical systems.

Hyder, Burhan↗

Data and Multistage Optimization for the New Grid

Three essential capabilities for using exascale computing resources on next generation power grid applications are: generating large renewable energy datasets, modeling damage and operations during and after extreme events, and employing multi-stage optimization for infrastructure planning. Powerscenarios, developed as part of the ExaSGD project, addresses these capabilities by enabling users to build synthetic wind farms for large test systems using numerical weather prediction-based data sources. We share examples of using Powerscenarios to build out wind farms on the ACTIVSg2000 test system, to enable simulated operations and emergency asset allocation during a hurricane strike, and to compute multi-stage infrastructure buildouts.

economic dispatch↗

The Locus Algorithm III: A Grid Computing system to generate catalogues of optimised pointings for Differential Photometry

This paper discusses the hardware and software components of the Grid Computing system used to implement the Locus Algorithm to identify optimum pointings for differential photometry of 61,662,376 stars and 23,799 quasars. The scale of the data, together with initial operational assessments demanded a High Performance Computing (HPC) system to complete the data analysis. Grid computing was chosen as the HPC solution as the optimum choice available within this project. The physical and logical structure of the National Grid computing Infrastructure informed the approach that was taken. That approach was one of layered separation of the different project components to enable maximum flexibility and extensibility.

Creaner, Oisń↗

Near wake evolution of a tidal stream turbine due to asymmetric sheared turbulent inflow with different integral length scales

Tidal stream turbines deployed at highly energetic open water sites are subjected to sheared inflow in the rotor plane. The inflow shear is expected to cause asymmetric loading on the rotor blades and affect the downstream wake. In the current study, two different turbulent inflow conditions, static-high shear and dynamic shear, were generated via an active-grid turbulence generator. A 1:20 scaled three-bladed horizontal axis tidal turbine model was tested in those conditions. The results were compared to a quasi-laminar case with no imposed turbulence or shear. The results show that the high shear reduces the average performance, with a drop of up to 16% in the optimal power coefficient. Besides, the shear profiles increase torque fluctuations and induce significant differences in wake hydrodynamics between the high-speed (upper) and low-speed (lower) regions. The large integral length scales further enhance the load fluctuations perceived by the rotor but have a negligible effect on the mean wake field quantities and the wake recovery. The lower half region featured a faster breakdown of tip vortex structure and a rapid drop of swirl number, a phenomenon conjectured to be a consequence of the strong turbulence intensities and Reynolds stresses in the lower half region. Furthermore, the sheared turbulent inflow also results in a very intensive energy redistribution process towards large-scale, low-frequency motions, which is important to the downstream turbines.

16 TIDAL AND WAVE POWER↗

Experimental Characterization Test of a Grid-Forming Inverter for Microgrid Applications

Standardized experimental testing protocols for grid forming (GFM) inverters to ensure expected operation under both normal and contingency conditions do not exist. Such protocols increase the confidence of system owner/operators that an inverter deployed in a proposed system will engage in typical behaviors to ensure interoperability with other units and ancillary equipment (e.g. protection equipment). This paper presents systematic and comprehensive test protocols to evaluate the performance of GFM inverters under the following operational configurations: islanded operation, heterogeneous islanded operation (parallel with a synchronous generator), grid-connected operation, and transition operation. A commercial GFM inverter is used to verify the test protocols and to understand the inverter's performance and functionalities. In particular, required configuration and tuning of the inverter will be explained in the full paper to enrich the testing protocol.

black start↗

Performance Evaluation of a Microgrid System with Grid-Forming and Grid-Following Inverters with Diesel Generators: Insights From Hardware Experiments

This paper presents a comprehensive performance evaluation of a microgrid system integrating grid-forming (GFM) inverters, grid-following (GFL) inverters, and a diesel generator, focusing on their interactions and behavior under various dynamic events. The study is conducted using a pure hardware setup comprising two GFM inverters, one GFL inverter, a diesel generator, load banks, a point of common coupling (PCC), and an emulated main grid. The evaluation specifically examines dynamic scenarios, including voltage jumps, phase jumps, rate of change of frequency (ROCOF), synchronization, and islanding operations, which pose critical challenges to system stability. Among all the tests conducted, the overloading and phase jump tests proved to be the most challenging. The capacity of the DC side is crucial for withstanding overloading and grid disturbance tests; otherwise, GFM inverters frequently trip due to DC undervoltage. Throughout all grid disturbance tests, the diesel generator consistently stands out as the most robust and reliable GFM unit in the system. Overall, insights from these hardware experiments shed light on the response characteristics of different generation types during grid disturbances and identify potential stability concerns in such hybrid microgrid systems.

14 SOLAR ENERGY↗

Impact Analysis of Utility-Scale Energy Storage on the ERCOT Grid in Reducing Renewable Generation Curtailments and Emissions

This paper explores the solutions for minimizing renewable energy (RE) curtailment in the Texas Electric Reliability Council of Texas (ERCOT) grid. By utilizing current and future planning data from ERCOT and the System Advisor Model from the National Renewable Energy Laboratory, we examine how future renewable energy (RE) initiatives, combined with utility-scale energy storage, can reduce CO2 emissions while reshaping Texas’s energy mix. The study projects the energy landscape from 2023 to 2033, considering the planned phase-out of fossil fuel plants and the integration of new wind/solar projects. By comparing emissions under different load scenarios, with and without storage, we demonstrate storage’s role in optimizing RE utilization. The findings of this paper provide actionable guidance for energy stakeholders, underscoring the need to expand wind and solar projects with strategic storage solutions to maximize Texas's RE capacity and substantially reduce CO2 emissions.

14 SOLAR ENERGY↗

Enhancing power grid resilience to winter storms via generator winterization with equity considerations

Here we develop two-stage stochastic programming models for generator winterization that enhance power grid resilience while incorporating social equity. The first stage in our models captures the investment decisions for generator winterization, and the second stage captures the operation of a degraded power grid, with the objective of minimizing load shed and social inequity. To incorporate equity into our models, we propose a concept called adverse effect probability that captures the disproportionate effects of power outages on communities with varying vulnerability levels. Grid operations are modeled using DC power flow, and equity is captured through mean or maximum adverse effects experienced by communities. We apply our models to a synthetic Texas power grid, using winter storm scenarios created from the generator outage data from the 2021 Texas winter storm. Our extensive numerical experiments show that more equitable outcomes, in the sense of reducing adverse effects experienced by vulnerable communities during power outages, are achievable with no impact on total load shed through investing in winterization of generators in different locations and capacities.

24 POWER TRANSMISSION AND DISTRIBUTION↗