Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fast neutron activation of ubiquitous materials

Nuclear explosions expose ubiquitous materials to large numbers of neutrons, producing a variety of radioactive isotopes. To simulate such phenomena from both fission and thermonuclear explosions, we irradiated 29 different targets with approximately 3 and 14 MeV neutrons and measured the beta-delayed gamma rays using germanium detectors. Therefore, for each neutron energy, the expected radioisotopes, half-lives, and gamma ray energies were deduced. From measurements of the ratios of activities of the radionuclides produced by neutron irradiations, we were able to identify several materials that are particularly sensitive to the neutron energy spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The 40 Ar(d,p) 41 Ar cross section between 3–7 MeV

To determine the safety of using argon as a deuteron beam stopping material, the 40 Ar(d,p) 41 Ar cross section was measured at average deuteron energies of 3.6 MeV, 5.5 MeV, and 7.0 MeV using an activation method. A 16-MeV deuteron beam produced by Lawrence Berkeley National Laboratory’s 88-Inch Cyclotron was degraded to each energy by nickel foils and the front wall of an aluminum gas chamber. The reduced-energy deuterons were used to activate a sample of nat Ar gas. After each irradiation, the gas chamber’s 41 Ar activation was measured with a high-purity germanium detector. The cross sections measured were larger than a previous measurement by ~40%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved Cumulative Fission Yield Measurements with Fission Spectrum Neutrons on 238U

Two isotopically-characterized targets of high-purity (99.961±0.002%) 238U metal and a neutron dosimetry package were exposed to a pulsed neutron irradiation using the Godiva IV critical assembly at the National Criticality Experiments Research Center to measure the integral fission product yields produced in a Watt fission neutron-energy spectrum. Following irradiation, the fissioned targets were counted with two broad energy germanium detectors. Estimates of the total fissions for each target were made using measurements of well-known fission products. The total number of fissions in each target were then used to measure the fission yields of 33 fission products, 18 of which are published as new measurements. Twelve of the 18 isotopes were in agreement with ENDF/B- VIII.0 using the zeta test and treating ENDF/B-VIII.0 as the true mean: 84mBr, 93Y, 94Y, 104Tc, 134I, 135I, 138Xe, 141Ba, 142Ba, 142La, 146Ce, and 149Nd. The ENDF/B-VIII.0 fission yield for 139Ba was only slightly outside of 1-s relative to the uncertainty measured in this work. Uncertainties for 5 fission product yields were markedly improved over those reported in ENDF/B-VIII.0: 128Sn, 129Sb, 130gSb, 131mTe, and 133I. The fission yields measured for 128Sn, 131mTe, and 133I were in good agreement with the ENDF/B-VIII.0 predicted fission yields. However, fission yields measurements of the isotopes 129Sb, and 130gSb deviated from the ENDF/B-VIII.0 value. Both of these isotopes reside near the doubly magic nuclear shell closures of 50 protons and 82 neutrons. These fission yields may be suppressed because of the odd-odd nuclear structure of 130gSb and the odd-even structure of 129Sb and isomer splitting. Comparisons to other recent work and a brief review with citations are included to support this conclusion.

Fission Yields↗

Comparison of gamma-ray spectral analysis methods for thick-walled UF 6 cylinders

Three data analysis methods were compared for gamma ray spectra collected by planar and coaxial high-purity germanium detectors (HPGe) on thick-walled uranium hexafluoride cylinders. The cylinder contents range from natural to low-enriched uranium (4.95% 235 U). Each spectrum was analyzed with the traditional 185.7 keV enrichment meter method, a 185.7/1001 keV ratio method, and the Fixed Energy Response Function Analysis with Multiple Efficiency (FRAM) software that utilizes low- and high-energy gamma rays and X-rays. When results for all cylinders were compared, the enrichment meter method and the 185.7/1001 keV peak ratio method consistently provided the most accurate data for all detector types. The error on the enrichment calculations analyzed with FRAM did not meet the international target value whereas those calculated with the enrichment meter and ratio method did. Enrichments calculated by FRAM were found to skew to higher values on natural uranium and to lower values on low-enriched uranium. FRAM calculated the least-precise enrichments; replicate analyses of single cylinders resulted in 235 U values that varied by as much as 19%. FRAM does have the significant advantages in that it does not require the use of calibration cylinders, infinite thickness criteria are not necessary, and it can be applied to any HPGe detector. Finally, if calibration cylinders are available, the enrichment meter and 185.7/1001 peak ratio are the recommended methods as they are the most accurate and precise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Short-lived photofission product yields from 238 U and 232 Th at Bremsstrahlung X-ray endpoint energies of 8, 14, and 20 MeV for nuclear forensics isotope production applications

The existing photofission product yield data sets are often based on nuclear models, and limited experimental measurements of these fission product yields have been performed. These experiments resulted in measured cumulative fission product yields (CFPYs) for 238 U and 232 Th for the bremsstrahlung X-ray endpoint energies of 8, 14, and 20 MeV. The half-lives of the reported fission products range from 1.07–40.8 s. This work is motivated by a demonstrated need for novel isotope production methods for nuclear forensics and improved nuclear data to support the nonproliferation community. A high-purity germanium detector and a pneumatic transfer system were employed for measurements of short-lived fission products, collecting data between cycles of accelerator irradiation and measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Modeling athermal phonons in novel materials using the G4CMP simulation toolkit

Understanding phonon and charge propagation in superconducting devices plays an important role in both performing low-threshold dark matter searches and limiting correlated errors in superconducting qubits. The Geant4 Condensed Matter Physics (G4CMP) package, originally developed for the Cryogenic Dark Matter Search (CDMS) experiment, models charge and phonon transport within silicon and germanium detectors and has been validated by experimental measurements of phonon caustics, mean charge-carrier drift velocities, and heat pulse propagation times. Here, in this work, we present a concise framework for expanding the capabilities for phonon transport to a number of other novel substrate materials of interest to the dark matter and quantum computing communities, including sapphire (Al 2 O 3 ), gallium arsenide (GaAs), lithium fluoride (LiF), calcium tungstate (CaWO 4 ), and calcium fluoride (CaF 2 ). We demonstrate the use of this framework in generating phonon transport properties of these materials and compare these properties with experimentally-determined values where available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sim-to-real supervised domain adaptation for radioisotope identification

Machine learning has the potential to improve the speed and reliability of radioisotope identification using gamma spectroscopy. However, meticulously labeling an experimental dataset for training is often prohibitively expensive, while training models purely on synthetic data is risky due to the domain gap between simulated and experimental measurements. In this research, we demonstrate that supervised domain adaptation can substantially improve the performance of radioisotope identification models by transferring knowledge between synthetic and experimental data domains. We consider two domain adaptation scenarios: (1) a simulation-to-simulation adaptation, where we perform multi-label proportion estimation using simulated high-purity germanium detectors, and (2) a simulation-to-experimental adaptation, where we perform multi-class, single-label classification using measured spectra from handheld lanthanum bromide (LaBr) and sodium iodide (NaI) detectors. We begin by pretraining a spectral classifier on synthetic data using a custom transformer-based neural network. After subsequent fine-tuning on just 64 labeled experimental spectra, we achieve a test accuracy of 96% in the sim-to-real scenario with a LaBr detector, far surpassing a synthetic-only baseline model (75%) and a model trained from scratch (80%) on the same 64 spectra. Furthermore, we demonstrate that domain-adapted models learn more human-interpretable features than experiment-only baseline models. Overall, our results highlight the potential for supervised domain adaptation techniques to bridge the sim-to-real gap in radioisotope identification, enabling the development of accurate and explainable classifiers even in real-world scenarios where access to experimental data is limited.

Lalor, Peter W.↗

Dense autoencoders, clustering techniques, and semi-supervised learning for HPGe $γ$-spectra

Classifying high-resolution gamma spectra by their isotopic content is an essential task in nuclear forensics and other applications. Traditional analysis methods are often time-intensive, but machine learning (ML) may help analysts quickly process many spectra. Such methods tend to rely on abundant, well-labeled data for training. Historical gamma data exists in various fields but is not uniformly useful for supervised ML due to inconsistent labeling. Here, to address some of these challenges, we present a method to classify and organize unlabeled data from high-purity germanium detectors using an autoencoding neural network (autoencoder). We trained dense autoencoders to compress gamma data into latent representations that enable efficient data characterization. By clustering the encoded spectra or lower-dimensional mappings of them, we identified and removed portions of over-abundant data categories, resulting in a more balanced dataset and improved autoencoder performance. This encoding and clustering pipeline also enabled the organization of spectra into self-consistent categories. Finally, we found that encoded representations showed potential as inputs for semi-supervised learning of nuclide identification (NID) labels, achieving an average F1 score of 0.85 ± 0.03 when mapping encodings to a set of 65 isotope labels.

Autoencoders↗

Coupling of TIGRESS and EMMA with Auxiliary Array TIP at TRIUMF

The combination of a germanium detector array and recoil mass spectrometer allows for high-sensitivity experiments in nuclear structure and astrophysics by enabling high-energy-resolution -ray spectroscopy and reaction measurements of weak fusion-evaporation, transfer or radiative-capture reactions in the presence of dominant background reaction channels. The TIGRESS -ray spectrometer with an upgraded data acquisition system has been coupled with the EMMA mass spectrometer alongside a suite of auxiliary detectors housed within TIGRESS such as TIP. This paper reviews the unique combination of radioactive beams at TRIUMF with the capabilities of TIGRESS and EMMA in the context of fusion-evaporation with TIP and radiative-capture reactions without an auxiliary array.

A/Q identification↗

Measurements of excitation functions and photoneutron cross sections of 96,98,99,104 Ru and 100 Mo

Photoneutron cross sections were extracted for isotopes of ruthenium and molybdenum on natural abundance targets via a reduced chi-squared analysis on excitation functions, or activation yields, as function of electron beam energy. Bremsstrahlung photons were produced via an electron linear accelerator and a tungsten radiator at the Idaho Accelerator Center. A total of 16 irradiations were performed with electron beam energies ranging from approximately 8 MeV to 23 MeV. Induced radioactivity was measured using a high purity germanium detector. The cross sections were extracted assuming a three parameter Lorentzian fit with a smooth truncated rise at reaction threshold.

07 - ISOTOPES AND RADIATION SOURCES↗

Search for charge non-conservation and Pauli exclusion principle violation with the M AJORANA D EMONSTRATOR

Charge conservation and the Pauli exclusion principle result from fundamental symmetries in the standard model of particle physics, and are typically taken as axiomatic. High-precision tests for small violations of these symmetries could point to new physics. Here we consider three models for violation of these processes, which would produce detectable ionization in the high-purity germanium detectors of the M AJORANA D EMONSTRATOR experiment. Using a 37.5 kg yr exposure, we report a lower limit on the electron mean lifetime, improving the previous best limit for the e → v e $\overline{v_e}$ v e decay channel by more than an order of magnitude. Here, we also present searches for two types of violation of the Pauli exclusion principle, setting limits on the probability of an electron to be found in a symmetric quantum state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First on-line detection of radioactive fission isotopes produced by laser-accelerated protons

Abstract The on-going developments in laser acceleration of protons and light ions, as well as the production of strong bursts of neutrons and multi- $$\hbox {MeV}$$ MeV photons by secondary processes now provide a basis for novel high-flux nuclear physics experiments. While the maximum energy of protons resulting from Target Normal Sheath Acceleration is presently still limited to around $$100 \, \hbox {MeV}$$ 100 MeV , the generated proton peak flux within the short laser-accelerated bunches can already today exceed the values achievable at the most advanced conventional accelerators by orders of magnitude. This paper consists of two parts covering the scientific motivation and relevance of such experiments and a first proof-of-principle demonstration. In the presented experiment pulses of $$200 \, \hbox {J}$$ 200 J at $$\approx \, 500 \, \hbox {fs}$$ ≈ 500 fs duration from the PHELIX laser produced more than $$10^{12}$$ 10 12 protons with energies above $$15 \, \hbox {MeV}$$ 15 MeV in a bunch of sub-nanosecond duration. They were used to induce fission in foil targets made of natural uranium. To make use of the nonpareil flux, these targets have to be very close to the laser acceleration source, since the particle density within the bunch is strongly affected by Coulomb explosion and the velocity differences between ions of different energy. The main challenge for nuclear detection with high-purity germanium detectors is given by the strong electromagnetic pulse caused by the laser-matter interaction close to the laser acceleration source. This was mitigated by utilizing fast transport of the fission products by a gas flow to a carbon filter, where the $$\upgamma$$ γ -rays were registered. The identified nuclides include those that have half-lives down to $$39 \, \hbox {s}$$ 39 s . These results demonstrate the capability to produce, extract, and detect short-lived reaction products under the demanding experimental condition imposed by the high-power laser interaction. The approach promotes research towards relevant nuclear astrophysical studies at conditions currently only accessible at nuclear high energy density laser facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Cross sections of 147–149 Sm( 6 Li,x) reactions for the production of 149 Tb for targeted alpha therapy

Terbium-149g (t 1/2 = 4.12 h) is of particular interest for targeted alpha therapy cancer treatment due to its ability to decay via both alpha and positron emission, making it a potential theranostic nuclide. Due to many challenges facing its production, there are limited facilities worldwide that have demonstrated the ability to produce this nuclide in quantities sufficient for medical research. Since the Cyclotron Institute at Texas A&M University is a specialized accelerator facility capable of accelerating a wide variety of ions, we are investigating production pathway options. One of the major challenges facing its production is the known co-production of the excited isomeric state, 149m Tb (t 1/2 = 4.1 min). However, this state does not decay to the ground state of 149g Tb, negating any potential contribution to its yield. Due to its short-half life, the cross section for the population of this state has never been measured. After calculating several potential reaction yields using predictive models, the reactions of 147–149 Sm( 6 Li,xn) 149 Tb were identified as candidates. Lithium-6 beams of varied energies between 45-65 MeV were impinged on enriched 147 Sm, 148 Sm, and 149 Sm targets at the Cyclotron Institute at Texas A&M University, and the reaction products were measured immediately following irradiation using high-purity germanium detectors, enabling detection of both 149m Tb and 149g Tb. Cross sections for all nuclides produced in sufficient activity in these reactions were also measured and reported here. We conclude that the population of 149m Tb is much preferred over population of the ground state for these 6 Li-induced reactions, and it is necessary to explore other options for 149g Tb production.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Counting facilities at the Black Hills Underground Campus

The Black Hills Underground Campus (BHUC) houses a low background counting facility on the 4850’ level of the Sanford Underground Research Facility (SURF) with ~4300 m w.e. of rock overburden. Currently there are five ultra-low-background, high-purity germanium detectors operating inside of a class-1,000 cleanroom at the Davis Campus, with a sixth anticipated to be installed within a year. Here, a robust nitrogen purge system and on-site personnel assistance allow these detectors to run continuously to support groups that need low background counting of materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radioisotope production using lasers: From basic science to applications

The discovery of chirped pulse amplification has led to great improvements in laser technology, enabling energetic laser beams to be compressed to pulse durations of tens of femtoseconds and focused to a few micrometers. Protons with energies of tens of MeV can be accelerated using, for instance, target normal sheath acceleration and focused on secondary targets. Under such conditions, nuclear reactions can occur, with the production of radioisotopes suitable for medical application. The use of high-repetition lasers to produce such isotopes is competitive with conventional methods mostly based on accelerators. In this paper, we study the production of 67Cu, 63Zn, 18F, and 11C, which are currently used in positron emission tomography and other applications. At the same time, we study the reactions 10B(p,α)7Be and 70Zn(p,4n)67Ga to put further constraints on the proton distributions at different angles, as well as the reaction 11B(p,α)8Be relevant for energy production. The experiment was performed at the 1 PW laser facility at Vega III in Salamanca, Spain. Angular distributions of radioisotopes in the forward (with respect to the laser direction) and backward directions were measured using a high purity germanium detector. Our results are in reasonable agreement with numerical estimates obtained following the approach of Kimura and Bonasera [Nucl. Instrum. Methods Phys. Res., Sect. A 637, 164–170 (2011)].

11C↗

Monitoring Methods for Early Detection of Inadvertent Fission Product Release at the Advanced Test Reactor

Isotope effluent data obtained during three instances of experiment failures at the Advanced Test Reactor (ATR) are analyzed to provide an overview of the methods used to detect initial signs of unintended fission product release. The data is contextualized with the operational experience, including means of identification and subsequent mitigation strategies, gained during these events. General trends as well as variations in isotopic behavior between the three failures are explored. Background on the Real Time Monitor, a High Purity Germanium detector, and other fission product monitoring systems utilized at the Advanced Test Reactor is also provided. The presented analysis was used to establish administrative action levels which are currently utilized by ATR for early detection of experiment fission product release. Early identification provides time to make programmatic decisions before approaching safety and environmental limits.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Results of the MAJORANA DEMONSTRATOR’s Search for Double-Beta Decay of 76 Ge to Excited States of 76 Se

The MAJORANA DEMONSTRATOR is searching for double-beta decay of 76 Ge to excited states (E.S.) in 76Se using a modular array of high purity Germanium detectors. 76 Ge can decay into three E.S.s of 76 Se. The E.S. decays have a clear event signature consisting of a ββ-decay with the prompt emission of one or two γ-rays, resulting in with high probability in a multi-site event. The granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 21.3 kg-y of isotopic exposure, the DEMONSTRATOR has set world leading limits for each E.S. decay, with 90% CL lower half-life limits in the range of (0.56 – 2.1) • 10 24 y. In particular, for the 2v transition to the first 0 + E.S. of 76 Se, a lower half-life limit of 0.68 • 10 24 at 90% CL was achieved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)

Poly Ethylene Naphthalate (PEN) is an industrial polymer plastic which is investigated as a low background, transparent, scintillating and wavelength shifting structural material. PEN scintillates in the blue region and has excellent mechanical properties both at room and cryogenic temperatures. Thus, it is an ideal candidate for active structural components in experiments for the search of rare events like neutrinoless double-beta decay or dark matter recoils. Such optically active structures improve the identification and rejection efficiency of backgrounds events, like this improving the sensitivity of experiments. This paper reports on the production of radiopure and transparent PEN plates These structures can be used to mount germanium detectors operating in cryogenic liquids (LAr, LN). Thus, as first application PEN holders will be used to mount the Ge detectors in the LEGEND-200 experiment. The whole process from cleaning the raw material to testing the PEN active components under final operational conditions is reported.

47 OTHER INSTRUMENTATION↗