Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geant4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Progress of Geant4 electromagnetic physics developments and applications

We report on developments of the Geant4 electromagnetic physics sub-libraries of Geant4 release 10.4 and beyond. Modifications are introduced to the models of photoelectric effect, bremsstrahlung, gamma conversion, single and multiple scattering. The theory-based Goudsmit-Saunderson model of electron/positron multiple scattering has been recently reviewed and a new improved version, providing the most accurate results for scattering of electrons and positrons, was made available. The updated interfaces, models and configurations have already been integrated into LHC applications and may be useful for any type of simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GQLink: an implementation of Quantized State Systems (QSS) methods in Geant4

Simulations in high energy physics (HEP) often require the numerical solution of ordinary differential equations (ODE) to determine the trajectories of charged particles in a magnetic field when particles move throughout detector volumes. Each crossing of a volume interrupts the underlying numerical method that solves the equations of motion, triggering iterative algorithms to estimate the intersection point within a given accuracy. The computational cost of this procedure can grow significantly depending on the application at hand. Quantized State System (QSS) is a recent family of discrete-event driven numerical methods exhibiting attractive features for this type of problems, such as native dense output (sequences of polynomial segments updated only by accuracy-driven events) and lightweight detection and handling of volume crossings. In this work we present GQLink, a proof-of-concept integration of QSS with the Geant4 simulation toolkit which stands as an interface for co-simulation that orchestrates robustly and transparently the interaction between the QSS simulation engine and aspects such as geometry definition and physics processes controlled by Geant4. In conclusion, we validate the accuracy and study the performance of the method in simple geometries (subject to intense volume crossing activity) and then in a realistic HEP application using a full CMS detector configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-149: Development of the Monte Carlo Simulation Platform Using Geant4 for Designing Heavy Ion Therapy Beam Nozzle

Purpose: The significant issue of particle therapy such as proton and carbon ion was a accurate dose delivery from beam line to patient. For designing the complex delivery system, Monte Carlo simulation can be used for the simulation of various physical interaction in scatters and filters. In this report, we present the development of Monte Carlo simulation platform to help design the prototype of particle therapy nozzle and performed the Monte Carlo simulation using Geant4. Also we show the prototype design of particle therapy beam nozzle for Korea Heavy Ion Medical Accelerator (KHIMA) project in Korea Institute of Radiological and Medical Science(KIRAMS) at Republic of Korea. Methods: We developed a simulation platform for particle therapy beam nozzle using Geant4. In this platform, the prototype nozzle design of Scanning system for carbon was simply designed. For comparison with theoretic beam optics, the beam profile on lateral distribution at isocenter is compared with Mont Carlo simulation result. From the result of this analysis, we can expected the beam spot property of KHIMA system and implement the spot size optimization for our spot scanning system. Results: For characteristics study of scanning system, various combination of the spot size from accerlator with ridge filter and beam monitor was tested as simple design for KHIMA dose delivery system. Conclusion: In this report, we presented the part of simulation platform and the characteristics study. This study is now on-going in order to develop the simulation platform including the beam nozzle and the dose verification tool with treatment planning system. This will be presented as soon as it is become available.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP3-04: Evaluation of the Dose Enhancement with Gold Nanoparticle in Microdosimetry Level Using the Geant4-DNA Toolkit

Purpose: This study investigated the dose enhancement effect of using gold nanoparticles (GNP) as radiation sensitizers radiated by different photon beam energies. Microdosimetry of photon-irradiated GNP was determined by the Geant4-DNA process in the DNA scale. Methods: Monte Carlo simulation was conducted using the Geant4 toolkit (ver. 10.2). A GNP with different sizes (30, 50, and 100nm diameter sphere) and a DNA were placed in a water cube (1µm{sup 3}). The GNP was irradiated by photon beams with different energies (50, 100, and 150keV) and produced secondary electrons to increase the dose to the DNA. Energy depositions were calculated for both with and without GNP and to investigate the dose enhancement effect at the DNA. The distance between the GNP and DNA was varied to optimize the best GNP position to the DNA. The photon beam source was set to 200nm from the GNP in each simulation. Results: It is found that GNP had a dose enhancement effect on kV photon radiations. For Monte Carlo results on different GNP sizes, distances between the GNP and DNA, and photon beam energies, enhancement ratio was found increasing as GNP size increased. The distance between the GNP and DNA affected the result that as distance increased while the dose enhancement ratio decreased. However, the effect of changing distance was not as significant as varying the GNP size. In addition, increasing the photon beam energy also increased the dose enhancement ratio. The largest dose enhancement ratio was found to be 3.5, when the GNP (100nm diameter) irradiated by the 150keV photon beam was set to 80nm from the DNA. Conclusion: Dose enhancement was determined in the DNA with GNP in the microdosimetry scale. It is concluded that the dose enhancement varied with the photon beam energy, GNP size and distance between the GNP and DNA.

60 APPLIED LIFE SCIENCES↗

Meson Photo-Production in GEANT4 for $E_\gamma = 0.225$ E γ = 0 . 225 -3.0 GeV using the $\gamma + p \rightarrow p + \pi^{0}$ reaction

The study of nuclear resonances in the intermediate energy regime requires accurate modeling of the experimental physics background. The cross sections in the GEANT4 toolkit do not adequately treat meson photo-production. The purpose of this study is to compare experimental data and theoretical models implemented in version 9.6.p02 of the GEANT4 Monte Carlo simulation toolkit for the exclusive and differential cross sections of $\pi^0$ photo-production. Two models were studied: the Chiral Invariant Phase Space (CHIPS) and Bertini Cascade (BERT). The cross section data from the models were compared to the experimental data from the CEBAF Large Acceptance Spectrometer (CLAS) of Jefferson Lab and the phenomenological Scattering Analysis Interactive Dial-in (SAID) model. Relativistic Breit-Wigner fits were used to compare the $\Delta(1232)$, N*(1520), N*(1650) and N*(1875) resonances from SAID, CLAS and CHIPS, giving agreements to within 3% for the mass of each resonance. The limited tabulated data set of BERT does not allow for an accurate description of the energy distribution, even following its improvement in version 10p02. The angular distributions of the cross sections show significant differences between CHIPS and both CLAS and SAID data, the latter being the most accurate model to describe the $\gamma p\rightarrow p\pi ^0$ exclusive cross section. Finally, the physics in CHIPS appears to be correct but it needs further development for the individual resonances contributions that could be useful since it is also the only model able to treat electromagnetically induced meson production for $A>1$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Introducing Tunes in Geant4 Hadronic Models

The talk will give an overview of tuning Geant4 model parameters via fits of simulated distributions to the experimental thin target data, and will introduce the concept of "tunes" in Geant4 hadronic models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Geant4 Introduction and Applications Workshop

This workshop talk overviews "Introduction to Geant4 simulation toolkit" which is consist of 1) Geant4 physics coverage, 2) Connecting to external physics engines such as Penelope and FLUKA and 3) Prospect toward heterogeneous computing with GPUs.

43 PARTICLE ACCELERATORS↗

Geant4 Material Definition

In Geant4, materials are defined using elements (G4Element) and isotopes (G4Isotope), supporting both single-element compositions and multi-element molecules or mixtures (by mass fraction). Each material is characterized by a mandatory density condition and optional parameters, such as state, temperature, and pressure. To simplify material definition and ensure accuracy, the G4NistManager is recommended for retrieving elements and materials from the NIST Material Database. These features make material specification in Geant4 flexible, efficient and consistent for describing complex detector geometry descriptions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of Geant4 Physics

Geant4 is a powerful toolkit for simulating particle interactions across a wide energy range (0 to ~TeV). It offers comprehensive physics processes for various particle types, allowing users to define custom processes using the G4VProcess interface. Major categories include electromagnetic, hadronic, decay, parameterized processes, and transportation. A critical feature is the PhysicsList, which specifies particles and processes for simulations. Users can choose between G4VUserPhysicsList for simpler environments or G4VModularPhysicsList for more complex scenarios, leveraging pre-defined or custom G4VPhysicsConstructors. Additionally, Geant4 provides reference physics lists and the G4PhysicsListFactory for well-established applications, facilitating simulation development in diverse domains.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Benchmarking a Defeatured Geant4 NIF Model with HTOAD and HNED Neutron Data

This study benchmarks a simplified Geant4 NIF Target Chamber (TC) model against foil measurements in two instruments: the HTOAD and HNED Snout. The number of product atoms per source neutron per gram ( N 0 /n/g ) is compared across multiple locations and material configurations. The model reproduces high energy threshold reactions dominated by 14 MeV neutrons to within a few percent, depending on location. Discrepancies occur where scattering and moderation are significant for low energy threshold reactions. The defeatured Geant4 model achieves comparable statistical precision with ∼400 times less CPU time than a full fidelity TC model in MCNP. The results can be produced locally on a laptop without the need for high performance computing. Low energy biasing can be improved by preserving room return pathways and implementing IRDFF cross section evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GADRAS + Geant4 Simulated Gamma Spectra Dataset

This dataset contains GADRAS and Geant4 simulated gamma-ray energy spectra used in the papers "Sim-to-real supervised domain adaptation for radioisotope identification" (https://doi.org/10.1016/j.nima.2025.171159) and "Unsupervised domain adaptation for radioisotope identification in gamma spectroscopy" (https://arxiv.org/abs/2603.05719). Each spectrum contains a mixture of several different radioisotopes, and the goal of the analysis is to leverage domain adaptation techniques to use a model trained on source-domain spectra (GADRAS) to classify target-domain spectra (Geant4).

Lalor, Peter William [Pacific Northwest National L↗

Combining Particle Tracking with Electromagnetic Radiation Showers: Merging GPT and Geant4 with Visualization

Field emitted electrons can seriously affect the operation of high-field, high-duty factor electron accelerators. Accelerated field emission can result in high average power beams which can radiation damage beamline components. In addition, localized losses generate thermal hot spots whose outgassing degrades the ultra-high vacuum required in photoinjectors and cryomodules. However, despite their importance, the effects of field emission are rarely included in the design and engineering of electron injectors. This work attempts to remedy this situation by combining two well-known and well-documented programs, GPT and Geant4, to track electrons and their losses in an injector beamline. This paper describes a system of programs which simulates electron paths and losses along the beamline. In addition, the tracking results can be zoomed and panned along and about the beampipe envelope using an open-source 3D CAD program. The scattering albedo calculations of the combined program, GPT-Geant4, are shown to be in good agreement with the literature albedos. The paper concludes with a dark current simulation for the LCLS-II injector from the cathode to the collimator at 1.5 m from the cathode.

Dowell, David H.↗

Optimization of {sup 6}LiF:ZnS(Ag) Scintillator Light Yield Using Geant4

Neutrons provide an effective tool to probe materials structure. Neutron diffraction is a method to determine the atomic and magnetic structure of a material based on neutron scattering. By this method a collimated incident beam of thermal neutrons heat the examined sample and based on the obtained diffraction pattern information on the structure of the material is provided. Research for developing a novel cold neutron detector for Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is underway at the NIST center for neutron research. The system unique design is aimed to provide over ten times fold faster analysis of materials than conventional system. In order to achieve the fast analysis a large number of neutron detectors is required. A key design constraint for this detector is the thickness of the neutron sensitive element. This is met using {sup 6}LiF:ZnS(Ag) scintillation material with embedded wavelength shifting (WLS) fibers conducting scintillation light to silicon photomultiplier photo-sensors. The detector sensitivity is determined by both the neutron capture probability ({sup 6}Li density) and the detectable light output produced by the ZnS(Ag) ionization, the latter of which is hindered by the fluorescence absorption of the scintillation light by the ZnS. Tradeoffs between the neutron capture probability, stimulated light production and light attenuation for determining the optimal stoichiometry of the {sup 6}LiF and ZnS(Ag) as well as the volume ratio of scintillator and fiber. Simulations performed using the GEANT4 Monte Carlo package were made in order to optimize the detector design. GEANT4 enables the investigation of the neutron interaction with the detector, the ionization process and the light transfer process following the nuclear process. The series of conversions required for this detector were modelled: - A cold neutron enters the sensor and is captured by {sup 6}Li in the scintillator mixture ({sup 6}Li (n,α) {sup 3}H reaction). The study of investigating the capture process probability for neutron energy of 5.1 meV to 2.27 meV (4 - 6 A) is presented. - Alpha particles and tritons travel for a few microns in the scintillation material (α ∼0.007 mm, T ∼0.04 mm) losing energy and ionizing the ZnS. The mean free path of the two particles in each of the component materials and the complete compound was investigated. - The ionization of the ZnS(Ag) scintillation material produces blue light photons with luminescence wavelength of 450 nm. The amount of light output produced for different grain sizes of ZnS is discussed. - A large portion of the scintillation photons are reabsorbed during their passage through the scintillation material. - The blue photons that reach the WLS fibers are absorbed by fluorescent dye and are re-emitted as green photons, conducted by the fiber to the SiPM photo-sensor. This work presents the CANDOR unique design and its design constrains, the results measured by the ultra-thin {sup 6}LiF:ZnS(Ag)-based neutron detector versus the simulation results for several binder concentrations. The light measurement attenuation results along with the measured stopping power were utilized to predict the sensitivity results of configuration with different ZnS grain size, weight ratios and fibers geometry (number and location). The simulations enable to optimize the final sensor design. This design successfully achieved both the high gamma rejection with a sensitive and accurate neutron event detection of 80 percent. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of dark bremsstrahlung in Geant4

A technique for the simulation of dark bremsstrahlung for electrons and muons in GEANT4 is presented. The total cross section is calculated using the Weizsäcker-Williams approximation and the outgoing kinematics are produced by scaling events produced in MadGraph/MadEvent to lower incident lepton energies, allowing the simulation to account for thick targets and lepton sources without fixed energies. In conclusion, compared with dedicated samples produced at an arbitrary particle energy, typical precision of better than 5% is achieved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Initial validation of ALFRED: A Monte Carlo code built on Geant4 for TREAT energy deposition

Predicting the energy deposited in the specimen during an experiment in the Transient Reactor Test (TREAT) Facility is a complex problem due to the nature of the transients occurring in the reactor. In addition, the many particles contributing to energy deposition have different behavior in time and space. ALFRED, a new Geant4 based code, is developed to transport and simulate each particle generated in the core. This code is verified against OpenMC (Open Monte Carlo) on the Godiva benchmark and a simple TREAT model. Next, the energy deposition in TREAT is calculated: 181.05 ± 0.01 MeV for the “instantaneous” energy deposition (which accounts for the energy deposited within 1 s after neutron emission) in fuel and 189.90 ± 0.01 MeV for the total energy deposition in fuel. We discuss these results in this paper with previous calculations and experimental evaluations. This work demonstrates ALFRED’s potential as a high-fidelity tool for computing the spatial and temporal energy deposition in TREAT paving the way for a better understanding of the energy coupling factors in TREAT.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of Geant4 fragmentation for Heavy Ion Therapy

12 C ion therapy has had growing interest in recent years for its excellent dose conformity. However at therapeutic energies, which can be as high as 400 MeV/u, carbon ions produce secondary fragments. For an incident 400 MeV/u 12 C ion beam, ~70% of the beam will undergo fragmentation before the Bragg Peak. The dosimetric and radiobiological impact of these fragments must be accurately characterised, as it can result in increasing the risk of secondary cancer for the patient as well as altering the relative biological effectiveness. Here, this work investigates the accuracy of three different nuclear fragmentation models available in the Monte Carlo Toolkit Geant4, the Binary Intranuclear Cascade (BIC), the Quantum Molecular Dynamics (QMD) and the Liege Intranuclear Cascade (INCL++). The models were benchmarked against experimental data for a pristine 400 MeV/u 12 C beam incident upon a water phantom, including fragment yield, angular and energy distribution. For fragment yields the three alternative models agreed between ~5 and ~35% with experimental measurements, the QMD using the “Frag” option gave the best agreement for lighter fragments but had reduced agreement for larger fragments. For angular distributions INCL++ was seen to provide the best agreement among the models for all elements with the exception of Hydrogen, while BIC and QMD was seen to produce broader distributions compared to experiment. BIC and QMD performed similar to one another for kinetic energy distributions while INCL++ suffered from producing lower energy distributions compared to the other models and experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗