Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Gaseous detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Modulating Concentration Of Hydrazine Vapor To Aid Detection

Three techniques, flow modulation, filament modulation, and reactive-filter modulation developed to obtain selective response to hydrazine or to methyl hydrazines from photoionization detector. Implemented in portable selective hydrazine detectors, useful where continuous or rapid, repetitive quantitative measurements of concentrations of vapors of these toxic substances required. Measure concentration of gaseous hydrazines in presence of other gases like cyclohexane, chlorofluorocarbons, and ammonia. Produce modulated signal, amplitude and phase indicating amount of hydrazine, monomethyl hydrazine, or 1,1-dimethyl hydrazine present in mixture. Used with such other detectors as electrochemical cells.

Stetter, Joseph R.

On charged particle tracks in cellulose nitrate and Lexan

Investigations were performed aimed at developing plastic nuclear track detectors into quantitative tools for recording and measuring multicharged, heavy particles. Accurate track etch rate measurements as a function of LET were performed for cellulose nitrate and Lexan plastic detectors. This was done using a variety of incident charged particle types and energies. The effect of aging of latent tracks in Lexan in different gaseous atmospheres was investigated. Range distributions of high energy N-14 particle bevatron beams in nuclear emulsion were measured. Investigation of charge resolution and Bragg peak measurements were carried out using plastic nuclear track detectors.

Benton, E. V.

Balloon-borne cryogenic spectrometer for measurement of lower stratospheric trace constituents

A liquid-nitrogen cooled, multidetector Fourier transform spectrometer has been constructed to measure minor stratospheric constituents via high resolution, earth-limb emission spectroscopy from a balloon-borne platform. Cryogenic cooling, combined with the use of extrinsic silicon photoconductor detectors cooled to liquid-helium temperature, allows the detection of weak emission features of gaseous species. The spectrometer has two basic scan modes: the first mode records the continuous spectrum from 650-2100/cm with 0.2/cm resolution; the second simultaneously records four preselected narrow intervals (about 175/cm bandpass each) with 0.02/cm resolution, unapodized. Filtering of the interferogram signal is done by real-time, digital signal processing. The most important feature of this flat mirror Michelson system, with respect to remote balloon-borne operation, is the dynamic alignment system which maintains the relative parallelism of the two flat reflectors of the interferometer. Species identified to date in data obtained during a Nov. 6, 1984, flight include: CO2, O3, H2O, CH4, HNO3, N2O, NO2, NO, CCl3F (Freon-11) and CF2Cl2 (Freon-12).

Brasunas, J. C.

Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure

High-resolution submillimeter/terahertz spectroscopy is important for studying atmospheric and interstellar molecular gaseous species. It typically uses heterodyne receivers where an unknown (weak) signal is mixed with a strong signal from the local oscillator (LO) operating at a slightly different frequency. The non-linear mixer devices for this frequency range are unique and are not off-the-shelf commercial products. Three types of THz mixers are commonly used: Schottky diode, superconducting hot-electron bolometer (HEB), and superconductor-insulation-superconductor (SIS) junction. A HEB mixer based on the two-dimensional electron gas (2DEG) formed at the interface of two slightly dissimilar semiconductors was developed. This mixer can operate at temperatures between 100 and 300 K, and thus can be used with just passive radiative cooling available even on small spacecraft.

Karasik, Boris S.

Sensitive gaseous hydrogen detection system

System utilizing new type hydrogen sensor has overall detection sensitivity and response speed higher than conventional hot-wire or hot-thermistor detectors. System measures concentrations of from 2 parts per million to 30 percent and is adaptable as leak detector and hazard alarm wherever hydrogen is used.

Macintyre, J. R.

Photoacoustic Chemical Detector

A laser vibrometer for measurement of ambient chemical species includes a laser that produces a beam that is split into a reference readout beam and a signal readout beam. A probe laser beam is tuned to an absorption feature of a molecular transition, and generates acoustic signals when incident on a gaseous species via the photo acoustic effect. The scattered acoustic signals are incident on a thin membrane that vibrates. The readout laser beam reflected from the vibrating membrane is mixed with the reference beam at the surface of a photo-EMF detector. Interferrometric fringes are generated at the surface of the photo-EMF detector. Electric current is generated in the photo-EMF detector when the fringes are in motion due to undulations in the signal readout beam imparted by the vibrating membrane. A highly sensitive photo-EMF detector is capable of detecting picoJoules or less laser energy generated by vibrating processes.

Prasad, Narasimha S.

Indicator Devices for Detection of Trace Gaseous Hydrazines

The relatively recent decrease in the acceptable time-weighted-average for hydrazines from 100 parts-per-billion (ppb) to 10 ppb rendered many trace hydrazine detectors either insensitive or inaccurate. Development of a rapid detection method for hydrazines at the new 10-ppb concentration was necessary so that test area personnel could reliably assess airborne hydrazines concentrations of a potentially contaminated area prior to entry. The reduction of Au(III) to Au(0) by hydrazines is a well characterized reaction and application of the corresponding yellow to purple color change was selected as a potentially useful means for detection of trace hydrazines in air. Tests with small quantities of KAuCl4 deposited on a variety of substrates were conducted using verified sources of 1,1-dimethylhydrazine, methylhydrazine, and hydrazine at approximately 10 ppb in air. Substrates tested were glass fiber filter paper, glass beads, anion exchange resin (AuCl4- form), and diatomaceous earth. The most successful of these substrates were glass fiber filter paper and diatomaceous earth. The KAuC14 impregnated glass fiber filter paper appeared to be somewhat light sensitive so further tests were conducted using the diatomaceous earth substrate. KAuCl4 concentration, substrate particle size, and sampler configuration were evaluated. Based on these tests, the device selected for further evaluation was a 5mm OD by 50mm glass tube containing 0.02-0.03g of 45/60 mesh diatomaceous earth coated with 2 percent KAuCl4. When connected to a sampling pump, response of the device to changes in relative humidity, ambient light, and high levels of other fluids, which might also be found in a propellant test area, was evaluated. False positive responses were not detected for exposures to relative humidity changes from 10 to 80 percent, sunlight for greater than 10 minutes, or percent levels of ammonia, isopropyl alcohol, nitrogen dioxide, and hydrogen. In addition, body emissions did not produce a false positive response in view of potential application for use inside protective clothing. The device was shown to reliably detect less than 10 ppb of the hydrazines tested using a 10 to 20L sample followed by a 2 to 5 minute color development time. Some field tests were conducted in parallel with conventional acidic firebrick sorbent tubes. There was generally very good agreement between the devices and firebrick sorbent tubes when greater than 10 ppb of a hydrazine was present.

Dee, Lou A.

Cross sections relevant to gamma ray astronomy

Gamma-ray production cross sections were measured for protons and alpha particles incident on targets consisting of nuclei of high cosmic abundance: C-12, N-14, O-16, Ne-20, Mg-24, Si-28 and Fe-56. Solid or gaseous targets were bombarded by monoenergetic beams of protons and alpha particles, and gamma rays were detected by two Ge(Li) detectors. The proton energy for each target was varied from threshold to about 24 MeV (lab); for alphas the range was from threshold to about 27 MeV. For most transitions, it was possible to measure the total cross section by placing the detectors at 30.5 deg and 109.9 deg where the fourth-order Legendre polynomial is zero. For the case of the 16O (E sub gamma = 6.13 MeV, multipolarity E3) cross sections, yields were measured at four angles. Absolute cross sections were obtained by integrating the beam current and by measuring target thicknesses and detector efficiencies. The Ge(Li) detector resolution was a few keV (although the peak widths were greater, due to Doppler broadening).

Dyer, P.

Design and construction of the X-ray instrumentation onboard the HaloSat CubeSat

HaloSat is the first mission funded by NASA’s Astrophysics Division to use the CubeSat platform. Using three co-aligned silicon drift detectors, the HaloSat observatory measures soft (0.4 to 7 keV) x-ray emission from sources of diffuse emission such as the hot, gaseous halo of the Milky Way. We describe the design and construction of the science payload on HaloSat and the reasoning behind many of the choices. As a direct result of the design choices and adherence to best practices during construction, the HaloSat science payload continues to perform well after more than one year on-orbit.

Daniel M. LaRocca

Development of an In Situ Fission Gas Release Instrument for Fuel Sample Irradiations in the High Flux Isotope Reactor

Experimental measurement of gaseous fission product release with respect to temperature and burnup is a critical aspect of understanding nuclear fuel performance, validating predictive models, and qualifying new fuels. To measure this phenomenon in real-time, Oak Ridge National Laboratory has developed an instrument for measuring in situ fission gas release from small-scale fuel samples irradiated in the High Flux Isotope Reactor (HFIR). The instrument uses a continuous flow of Heover the fuel samples to sweep gaseous fission products from a sealed capsule in the HFIR Be reflector to an instrument station adjacent to the reactor. The instrument station houses two high-purity germanium (HPGe) detectors that measure decay gamma rays from fission products passing through a room temperature dwell chamber placed over the detector crystal. The sealed capsules in the reactor are designed to modulate fuel sample temperatures between 700 and 1,100°C by changing the Ar/He gas mixture surrounding the capsules during irradiation. N-type thermocouples are incorporated into the capsule housing to record real-time fuel temperatures. The capsules are heated primarily by prompt gamma rays emitted from the HFIR core with minimal heat contributions from fission in the fuel samples to minimize temperature gradients in the specimens for separate-effects characterization of the material. This paper describes modeling of time-dependent nuclear heating and fission product formation in fuel samples, thermal characteristics of the in-core capsules, and expected gaseous fission product gamma spectra at the HPGe instrument station.

Mulligan, Padhraic L [ORNL] (ORCID:000000025826540

Correcting beam space charge effects in Active-Target Time Projection Chamber

By providing a large gaseous volume for nuclear interactions while simultaneously recording the tracks of resulting reaction products, an active target serves as both a thick target and a detector. Once a reaction occurs, the emitted charged fragments strip electrons from the target gas along their path as they transverse the detector. Collection of these stripped electrons allow for detection of the product tracks. As beam intensity increases, the resulting ionization in the active target can significantly distort this collection of electrons. If left uncorrected, the resulting measurements could be wrong. In this paper, we investigate the impact of the space charge produced by heavy radioactive beams within the Active Target - Time Projection Chamber at Michigan State University. The beams are injected parallel to the electric field of the time projection chamber which is operated without a magnetic field for this experiment. Furthermore, we analyze the rate dependence of the space charge effects and demonstrate that they can be modeled and effectively corrected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Feedback-Controlled Regulation of Gas Pressure

Internal pressure maintained over wide range of external pressures and exhaust rates. Gaseous pressure in liquid-nitrogen Dewar regulated by movable tapered plug, positioned automatically in response to signals generated by piezoelectric pressure transducer. Designed specifically to maintain airborne infrared detectors at constant temperature in evaporating liquid nitrogen, system modified to regulate pressure in other enclosed systems.

Smith, J. C.

Methods of use for sensor based fluid detection devices

Methods of use and devices for detecting analyte in fluid. A system for detecting an analyte in a fluid is described comprising a substrate having a sensor comprising a first organic material and a second organic material where the sensor has a response to permeation by an analyte. A detector is operatively associated with the sensor. Further, a fluid delivery appliance is operatively associated with the sensor. The sensor device has information storage and processing equipment, which is operably connected with the device. This device compares a response from the detector with a stored ideal response to detect the presence of analyte. An integrated system for detecting an analyte in a fluid is also described where the sensing device, detector, information storage and processing device, and fluid delivery device are incorporated in a substrate. Methods for use for the above system are also described where the first organic material and a second organic material are sensed and the analyte is detected with a detector operatively associated with the sensor. The method provides for a device, which delivers fluid to the sensor and measures the response of the sensor with the detector. Further, the response is compared to a stored ideal response for the analyte to determine the presence of the analyte. In different embodiments, the fluid measured may be a gaseous fluid, a liquid, or a fluid extracted from a solid. Methods of fluid delivery for each embodiment are accordingly provided.

Lewis, Nathan S.

The Athena/X-IFU, from Detector Development to Scientific Feasibility Studies via Simulations

The investigation of the physical hot and energetic phenomena in the Universe will further improve our understanding of the assembly of the largest structures and massive halos of galaxies, and of the role of black holes in shaping the Universe as we see it. Spatially resolved X-ray high-resolution spectroscopy will be a crucial tool to achieve these scientific goals. The X-IFU instrument onboard the Athena observatory will provide us with these capabilities through the use of arrays of Transition edge microcalorimeters detectors. These superconducting devices will deliver the required exquisite spectral resolution needed to achieve the core science objectives, such as the characterization of turbulence and bulk motions in the hot gaseous atmospheres of groups and clusters of galaxies in order to unveil the process of large scale structures assembly. I will present the Transition Edge Sensors principle, the status of the instrumental development for the X-IFU instrument, and discuss their performance in view of the scientific objectives of the Athena mission. I will further present the case of a feasibility study and optimisation of the observing strategy for the characterization of the internal dynamics of the intra-cluster medium, through the use of mock simulations of observations with the X-IFU instrument.

Sophie Beaumont

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION

Method and means for helium/hydrogen ratio measurement by alpha scattering

An apparatus for determining helium to hydrogen ratios in a gaseous sample is presented. The sample is bombarded with alpha particles created by a self contained radioactive source and scattering products falling within a predetermined forward scattering angular range impact a detector assembly. Two detectors are mounted in tandem, the first completely blocking the second with respect to incident scattering products. Alpha particle/hydrogen or alpha particle/helium collisions are identified by whether scattering product impacts occur simultaneously in both detectors or only in the first detector. Relative magnitudes of the two pulses can be used to further discriminate against other effects such as noise and cosmic ray events.

Whitehead, A. B.

A gas chromatographic air analyzer fabricated on a silicon wafer

A miniature gas analysis system has been built based on the principles of gas chromatography (GC). The major components are fabricated in silicon using photolithography and chemical etching techniques, which allows size reductions of nearly three orders of magnitude compared to conventional laboratory instruments. The chromatography system consists of a sample injection valve and a 1.5-m-long separating capillary column, which are fabricated on a substrate silicon wafer. The output thermal conductivity detector is separately batch fabricated and integrably mounted on the substrate wafer. The theory of gas chromatography has been used to optimize the performance of the sensor so that separations of gaseous hydrocarbon mixtures are performed in less than 10 s. The system is expected to find application in the areas of portable ambient air quality monitors, implanted biological experiments, and planetary probes.

Terry, S. C.

Fire Detection Organizing Questions

Verified models of fire precursor transport in low and partial gravity: a. Development of models for large-scale transport in reduced gravity. b. Validated CFD simulations of transport of fire precursors. c. Evaluation of the effect of scale on transport and reduced gravity fires. Advanced fire detection system for gaseous and particulate pre-fire and fire signaturesa: a. Quantification of pre-fire pyrolysis products in microgravity. b. Suite of gas and particulate sensors. c. Reduced gravity evaluation of candidate detector technologies. d. Reduced gravity verification of advanced fire detection system. e. Validated database of fire and pre-fire signatures in low and partial gravity.

Source record