Resistance exercise prevents plantar flexor deconditioning during bed rest

Because resistance exercise (REX) and unloading induce opposing neuromuscular adaptations, we tested the efficacy of REX against the effects of 14 d of bed rest unloading (BRU) on the plantar flexor muscle group. Sixteen men were randomly assigned to no exercise (NOE, N = 8) or REX (N = 8). REX performed 5 sets x 6-10 repetitions to failure of constant resistance concentric/eccentric plantar flexion every other day during BRU. One-repetition maximum (1RM) strength was tested on the training device. The angle-specific torque-velocity relationship across 5 velocities (0, 0.52, 1.05, 1.75, and 2.97 rad.s-1) and the full range-of-motion power-velocity relationship were assessed on a dynamometer. Torque-position analyses identified strength changes at shortened, neutral, and stretched muscle lengths. Concentric and eccentric contractile work were measured across ten repetitions at 1.05 rad.s-1. Maximal neural activation was measured by surface electromyography (EMG). 1RM decreased 9% in NOE and improved 11% in REX (P < 0.05). Concentric (0.52 and 1.05 rad.s-1), eccentric (0.52 and 2.97 rad.s-1), and isometric angle-specific torques decreased (P < 0.05) in NOE, averaging 18%, 17%, and 13%, respectively. Power dropped (P < 0.05) in NOE at three eccentric (21%) and two concentric (14%) velocities. REX protected angle-specific torque and average power at all velocities. Concentric and eccentric strength decreased at stretched (16%) and neutral (17%) muscle lengths (P < 0.05) in NOE while REX maintained or improved strength at all joint positions. Concentric (15%) and eccentric (11%) contractile work fell in NOE (P < 0.05) but not in REX. Maximal plantar flexor EMG did not change in either group. In summary, constant resistance concentric/eccentric REX completely prevented plantar flexor performance deconditioning induced by BRU. The reported benefits of REX should prove useful in prescribing exercise for astronauts in microgravity and for patients susceptible to functional decline during bed- or chair-bound hospital stays.

NASA Discipline Musculoskeletal↗

Noble gases and shock effects in the Odessa octahedrite

Noble gas contents and shock effects have been studied in 21 Odessa irons from known geographic locations. Cosmogenic He-3, Ne-21, Ar-38 contents and He-3/Ne-21 ratios vary by factors of 62, 91, 68, and 1.55, respectively, while Ne-22/Ne-21 ratios are virtually constant at 1.07. The samples fall into two groups differing by a factor of 4.1 in exposure age, 1000 in source mass, or some combination of these. Three samples show significant shock effects, two of them to above 130 kbar, probably arising during terrestrial impact from the crater-forming explosion. As in Canyon Diablo plains specimens, noble gas contents do not correlate with siting or shock.

Herzog, G. F.↗

Submillimeter horizontal position determination using very long baseline interferometry

An analysis of interferometric phase delays from 15 years of Mark I and Mark III very long baseline interferometry (VLBI) experiments carried out with two radio telescopes in Westford, Massachusetts, about 1.24 km apart, yields weighted root-mean-square (WRMS) scatters about the mean locally horizontal coordinates of 1.0 and 2.0 mm in the north and east directions, respectively. It is concluded that VLBI antennas of at least of the structural quality of the pair in Westford satisfy a necessary but not sufficient condition for being able to maintain a global reference system with submillimeter per year accuracy for intervals in excess of a decade. These data are also used to determine an error model for the VLBI group delay measurements, and, for this particular pair of telescopes, they indicate that the WRMS difference between group and phase delays is composed of a constant part (5.4 mm, for the most recent data) and a SNR term which is about 10 percent larger than that computed theoretically.

Herring, T. A.↗

Rime-, mixed- and glaze-ice evaluations of three scaling laws

This report presents the results of tests at NASA Lewis to evaluate three icing scaling relationships or 'laws' for an unheated model. The laws were LWC x time = constant, one proposed by a Swedish-Russian group and one used at ONERA in France. Icing tests were performed in the NASA Lewis Icing Research Tunnel (IRT) with cylinders ranging from 2.5- to 15.2-cm diameter. Reference conditions were chosen to provide rime, mixed and glaze ice. Scaled conditions were tested for several scenarios of size and velocity scaling, and the resulting ice shapes compared. For rime-ice conditions, all three of the scaling laws provided scaled ice shapes which closely matched reference ice shapes. For mixed ice and for glaze ice none of the scaling laws produced consistently good simulation of the reference ice shapes. Explanations for the observed results are proposed, and scaling issues requiring further study are identified.

Anderson, David N.↗

Variable-Depth Liner Evaluation Using Two NASA Flow Ducts

Four liners are investigated experimentally via tests in the NASA Langley Grazing Flow Impedance Tube. These include an axially-segmented liner and three liners that use reordering of the chambers. Chamber reordering is shown to have a strong effect on the axial sound pressure level profiles, but a limited effect on the overall attenuation. It is also shown that bent chambers can be used to reduce the liner depth with minimal effects on the attenuation. A numerical study is also conducted to explore the effects of a planar and three higher-order mode sources based on the NASA Langley Curved Duct Test Rig geometry. A four-segment liner is designed using the NASA Langley CDL code with a Python-based optimizer. Five additional liner designs, four with rearrangements of the first liner segments and one with a redistribution of the individual chambers, are evaluated for each of the four sources. The liner configuration affects the sound pressure level profile much more than the attenuation spectra for the planar and first two higher-order mode sources, but has a much larger effect on the SPL profiles and attenuation spectra for the last higher-order mode source. Overall, axially variable-depth liners offer the potential to provide improved fan noise reduction, regardless of whether the axially variable depths are achieved via a distributed array of chambers (depths vary from chamber to chamber) or a group of zones (groups of chambers for which the depth is constant).

Jones, M. G.↗

The Effect of Habitual Smoking on VO2max

VO2max is associated with many factors, including age, gender, physical activity, and body composition. It is popularly believed that habitual smoking lowers aerobic fitness. PURPOSE: to determine the effect of habitual smoking on VO2max after controlling for age, gender, activity and BMI. METHODS: 2374 men and 375 women employed at the NASA/Johnson Space Center were measured for VO2max by indirect calorimetry (RER>=1.1), activity by the 11 point (0-10) NASA Physical Activity Status Scale (PASS), BMI and smoking pack-yrs (packs day*y of smoking). Age was recorded in years and gender was coded as M=1, W=0. Pack.y was made a categorical variable consisting of four levels as follows: Never Smoked (0), Light (1-10), Regular (11-20), Heavy (>20). Group differences were verified by ANOVA. A General Linear Models (GLM) was used to develop two models to examine the relationship of smoking behavior on VO2max. GLM #1(without smoking) determined the combined effects of age, gender, PASS and BMI on VO2max. GLM #2 (with smoking) determined the added effects of smoking (pack.y groupings) on VO2max after controlling for age, gender, PASS and BMI. Constant errors (CE) were calculated to compare the accuracy of the two models for estimating the VO2max of the smoking subgroups. RESULTS: ANOVA affirmed the mean VO2max of each pack.y grouping decreased significantly (p<0.01) as the level of smoking exposure increased. GLM #1 showed that age, gender, PASS and BMI were independently related with VO2max (R2 = 0.642, SEE = 4.90, p<0.001). The added pack.y variables in GLM #2 were statistically significant (R2 change = 0.7%, p<0.01). Post hoc analysis showed that compared to Never Smoked, the effects on VO2max from Light and Regular smoking habits were -0.83 and -0.85 ml.kg- 1.min-1 respectively (p<0.05). The effect of Heavy smoking on VO2max was -2.56 ml.kg- 1.min-1 (p<0.001). The CE s of each smoking group in GLM #2 was smaller than the CE s of the smoking group counterparts in GLM #1. CONCLUSIONS: After accounting for the effects of gender, age, PASS and BMI the effect of habitual smoking on reducing VO2max is minimal, about 0.85 ml/kg/min, until the habit exceeds 20 pack.y at which point an additional decrease of 1.71 ml/kg/min is noted. Adding pack.y data improves the accuracy of predicting the VO2max of smokers.

Wier, Larry T.↗

Aromatic Polyimides With Low Dielectric Constants

Linear aromatic polyimides developed containing dimethylsilane linkages in dianhydride portions of molecules and at least one trifluoromethyl group in each of diamine portions. Polyimides offer advantages of thermal stability, low density, resistance to ionizing radiation, toughness, flexibility, and exhibit lower dielectric constants. Also polyimides nearly transparent and colorless; an advantage in protective coating of solar photovoltaic cells, optical components, and antennas.

St. Clair, Anne K.↗

Solar Cell Calibration and Measurement Techniques

The increasing complexity of space solar cells and the increasing international markets for both cells and arrays has resulted in workshops jointly sponsored by NASDA, ESA and NASA. These workshops are designed to obtain international agreement on standardized values for the AMO spectrum and constant, recommend laboratory measurement practices and establish a set of protocols for international comparison of laboratory measurements. A working draft of an ISO standard, WD15387, "Requirements for Measurement and Calibration Procedures for Space Solar Cells" was discussed with a focus on the scope of the document, a definition of primary standard cell, and required error analysis for all measurement techniques. Working groups addressed the issues of Air Mass Zero (AMO) solar constant and spectrum, laboratory measurement techniques, and te international round robin methodology. A summary is presented of the current state of each area and the formulation of the ISO document.

Bailey, Sheila↗

Solar Cell Calibration and Measurement Techniques

The increasing complexity of space solar cells and the increasing international markets for both cells and arrays has resulted in workshops jointly sponsored by NASDA, ESA and NASA. These workshops are designed to obtain international agreement on standardized values for the AMO spectrum and constant, recommend laboratory measurement practices and establish a set of protocols for international comparison of laboratory measurements. A working draft of an ISO standard, WDI 5387, 'Requirements for Measurement and Calibration Procedures for Space Solar Cells' was discussed with a focus on the scope of the document, a definition of primary standard cell, and required error analysis for all measurement techniques. Working groups addressed the issues of Air Mass Zero (AMO) solar constant and spectrum, laboratory measurement techniques, and the international round robin methodology. A summary is presented of the current state of each area and the formulation of the ISO document.

Bailey, Sheila↗

Natural environment design criteria for the space station program definition phase

The natural environment design criteria requirements for use in the Space Station and its Elements (SSPE) definition phase studies are presented. The atmospheric dynamic and thermodynamic environments, meteoroids, radiation, physical constants are addressed. It is intended to enable all groups involved in the definition phase studies to proceed with a common and consistent set of natural environment criteria requirements.

Vaughan, W. W.↗

Natural environment design criteria for the Advanced X-ray Astrophysics Facility (AXAF) definition and preliminary design

This document provides the natural environment design criteria requirements for use in the Advanced X-Ray Astrophysics Facility (AXAF) definition and preliminary design studies. The atmospheric dynamic and thermodynamic environments, meteoroids, radiation, magnetic fields, and physical constants are all addressed. This information will enable all groups involved in the definition and preliminary design studies to proceed with a common and consistent set of natural environment criteria requirements.

Greene, W. M.↗

On Characterization of Laminar to Turbulent Transitional Flow in the Truncated IHF Semi-Elliptical Nozzle

This paper reports computational analysis and experimental data to characterize the laminar to turbulent flow transition in a high-enthalpy panel test facility at NASA Ames Research Center. The recently developed facility configuration uses a truncated version of an existing semi-elliptical nozzle in the 60-MW Interaction Heating Facility, and it provides testing capability for panel test articles as large as 43.2 cm x 43.2 cm (17 in x 17 in). A water-cooled calibration plate, which is attached to the semi-elliptical nozzle bottom surface and instrumented with twenty Gardon-gage heat flux calorimeters and twelve pressure gages, is used to characterize the convective heating environment over the panel test articles. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, and the flowfields over panel test articles, and comparisons with the measured test data. Both laminar and turbulent simulations are performed. Constant current studies are performed: the measured data are grouped at the same arc current levels with varying mass flow rates, and they are compared with corresponding computations. For all currents studied, these studies indicate that the semi-elliptical nozzle flow is transitional at relatively higher mass flow rates within the facility operating envelope.

Arc-jets↗

On Characterization of Laminar to Turbulent Transitional Flow in the Truncated IHF Semi-Elliptical Nozzle

This paper reports computational analysis and experimental data to characterize the laminar to turbulent flow transition in a high-enthalpy panel test facility at NASA Ames Research Center. The recently developed facility configuration uses a truncated version of an existing semi-elliptical nozzle in the 60-MW Interaction Heating Facility, and it provides testing capability for panel test articles as large as 43.2 cm x 43.2 cm (17 in x 17 in). A water-cooled calibration plate, which is attached to the semi-elliptical nozzle bottom surface and instrumented with twenty Gardon-gage heat flux calorimeters and twelve pressure gages, is used to characterize the convective heating environment over the panel test articles. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, and the flowfields over panel test articles, and comparisons with the measured test data. Both laminar and turbulent simulations are performed. Constant current studies are conducted: the measured data are grouped at the same arc current levels with varying mass flow rates, and they are compared with corresponding computations. For all currents considered, these studies indicate that the semi-elliptical nozzle flow is transitional at relatively higher mass flow rates within the facility operating envelope. An approximate facility map for the transitional flow characterization is developed, showing laminar and transitional to turbulent flow regions.

Arc-jets↗

Imaging performance of annular apertures

An investigation is conducted of images which are formed by aberration free optical systems with annular apertures in the whole range of central obstructions ratios approaching 1.0. It was found that annular apertures form central and surrounding ring groups. The energy fractions in the central and surrounding ring groups do not decrease with increasing obstruction ratio, but remain constant for all obstruction ratios and for all fractional energy levels. Images formed by unobstructed apertures are quantitatively superior because they are smaller than those formed by annular apertures.

Tschunko, H. F. A.↗

Natural environment design criteria for the Space Station definition and preliminary design

The natural environment design criteria for the Space Station Program (SSP) definition and preliminary design are presented. Information on the atmospheric, dynamic and thermodynamic environments, meteoroids, radiation, magnetic fields, physical constants, etc. is provided with the intension of enabling all groups involved in the definition and preliminary design studies to proceed with a common and consistent set of natural environment criteria requirements. The space station program elements (SSPE) shall be designed with no operational sensitivity to natural environment conditions during assembly, checkout, stowage, launch, and orbital operations to the maximum degree practical.

Vaughan, W. W.↗

Crystallization of the Fab from a human monoclonal antibody against gp 41 of human immunodeficiency virus type I

A monoclonal IgG antibody directed against gp 41 from the human immunodeficiency virus (HIV-1) has been crystallized in both intact and Fab forms. Crystals of the intact antibody grow as tetragonal-like prisms too small for conventional X-ray analysis. However, the Fab portion of the antibody produces suitable platelike crystals which belong to the space group P2(1)2(1)2(1) with unit cell constants of a = 66.5 A, b = 74.3 A, and c = 105.3 A. There is one molecule of Fab in the asymmetric unit. The Fab crystals show diffraction to d-spacings less than 3.0 A.

Casale, Elena↗

Space Qualification of Laser Diode Arrays

Laser instruments have great potential in enabling a new generation of remote-sensing scientific instruments. NASA s desire to employ laser instruments aboard satellites, imposes stringent reliability requirements under severe conditions. As a result of these requirements, NASA has a research program to understand, quantify and reduce the risk of failure to these instruments when deployed on satellites. Most of NASA s proposed laser missions have base-lined diode-pumped Nd:YAG lasers that generally use quasi-constant wave (QCW), 808 nm Laser Diode Arrays (LDAs). Our group has an on-going test program to measure the performance of these LDAs when operated in conditions replicating launch and orbit. In this paper, we report on the results of tests designed to measure the effect of vibration loads simulating launch into space and the radiation environment encountered on orbit. Our primary objective is to quantify the performance of the LDAs in conditions replicating those of a satellite instrument, determine their limitations and strengths which will enable better and more robust designs. To this end we have developed a systematic testing strategy to quantify the effect of environmental stresses on the optical and electrical properties of the LDA.

Troupaki, Elisavet↗

Microstructural Characterization of Thin Polyimide Films by Positron Lifetime Spectroscopy

Positron lifetimes have been measured in a series of thin aromatic polyimide films. No evidence of positronium formation was observed in any of the films investigated. All test films exhibited only two positron lifetime components, the longer component corresponding to the positrons annihilating at shallow traps. Based on these trapped positron lifetimes, free volume fractions have been calculated for all the films tested. A free volume model has been developed to calculate the dielectric constants of thin polyimide films. The experimental and the calculated values for the dielectric constants of the films tested are in reasonably good agreement. It has been further noted that the presence of bulky CF(sub 3) groups and meta linkages in the polyimide structure results in higher free volume fraction and, consequently, lower dielectric constant values for the films studied.