Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GODIVA REACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Investigating Fission Reaction Rate Ratio Sensitivities [Abstract]

Reaction rate ratios are a measurable parameter for reactor and criticality applications. A number of foil irradiations and fission chamber measurements have been performed for critical assemblies at Los Alamos National Laboratory starting in the 1950’s including (i) Godiva, a bare HEU spherical assembly; (ii) Flattop-25, a spherical assembly consisting of an HEU core and a natural uranium reflector; (iii) Jezebel, a bare 239 Pu assembly; and (iv) Flattop-Pu, a spherical assembly consisting of a 239Pu core and a natural uranium reflector. Fission ratio data for 238 U(n,f)/ 235 U(n,f), 237 Np(n,f)/ 235 U(n,f), 233 U(n,f)/ 235 U(n,f) and 239 Pu(n,f)/ 235 U(n,f) were obtained and reported. The EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) project at Los Alamos National Laboratory (LANL) aims to constrain nuclear data by using a suite of measurement types beyond k-effective. Recent investigations include the use of pulsed spheres for nuclear data validation and other measurement methods of interest. One focus of the work is to determine if other methods are complimentary to the critical experiments utilized for nuclear data validation. It is anticipated the investigations will help inform methods that may be utilized in machine learning algorithms for nuclear validation. In order to use a measurement type for nuclear validation, it is necessary to obtain cross-section sensitivities for parameters. This work looks at reaction rate ratio sensitivities with SENSMG and Monte Carlo N-Particle R Code Version 6.21.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Monte Carlo estimation of an effect of uncertainties in initial data on solving the transport equation by means of the MCU code

A new version of the tally module of the MCU software package is developed in which the approach for taking directly into account the uncertainty in initial data is implemented that is recommended by the international standard on estimating the uncertainty in results of measuring (ISO 13005). The new module makes it possible to evaluate the effect of uncertainty in initial data (caused by technological tolerances in fabrication of structural members of the core) on neutronic characteristics of the reactor. The developed software is adapted to parallel computing with the use of multiprocessor computers, which significantly reduces the computation time: the parallelization coefficient is almost equal to 1. Testing is performed by examples of solving the problem on criticality for the Godiva benchmark experiment and also for the infinite lattice of fuel assemblies of the VVER-440, VVER-1000, and VVER-1200. The results of calculations of the uncertainty in neutronic characteristics (effective multiplication factor, fission reaction rate), which is caused by uncertainties in initial data due to technological tolerances, are compared (in the first case) to the published results obtained using the precision MCNP5 code and (in the second case) to those obtained by means of the RADAR engineering program. A good agreement of results is achieved for all cases.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experiment Design and Preparation for a Shielding Benchmark Utilizing Godiva-IV

An experiment is currently being designed to provide a high-quality shielding benchmark for Criticality Accident Alarm System (CAAS) modeling. Previous benchmarks have suffered from uncertainty primarily due to two factors. The first factor is radiation that is not directly coming from the source, also known as room return. Room return is notoriously difficult to account for in experimental data and to model in benchmarks. The second factor is uncertainty associated with the source term itself. In order to reduce these two sources of uncertainty, this experiment will utilize a room return shield [1] that will reduce the effect of room return and previous work performed to ensure the reproducibility of the source term. The experiment will use the Godiva IV [2] assembly located at the National Criticality Experiments Research Center (NCERC) to provide a neutron source representative of a criticality accident. Previous experiments [3]-[4] have shown that Godiva IV is capable of producing both bursts and steady-state emissions of equal magnitude which will allow for reduced uncertainty in the source term. The room return shield will house and isolate the shielding samples, neutron activation foils, and other detectors. Data collected will provide a comparison of the neutron and gamma dose for shielded and unshielded configurations. This data will be used to validate shielding data used for modeling criticality accident alarm systems. Shielding samples included in this benchmark are C, Fe, NaCl, Pb, high density polyethylene, and SiO 2 . This paper details the design of the room return shield, the experimental plan, challenges, and mitigation strategies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AWE neutron spectrometry results from Godiva-IV (NCERC) characterization - Paper 135

In recent years, it was deemed necessary for the Godiva-IV critical assembly - along with other assemblies collectively forming what is now known as the National Critical Experiments Research Center (NCERC) - to relocate to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). An experiment was proposed (IER-148) under the Nuclear Criticality Safety Program for an international inter-comparison of Nuclear Accident Dosimetry (NAD) using the Godiva-IV assembly, in order to arrest the long term decline in the testing and validation of these systems. Due to the knock-on effect of the change of location on the neutron leakage spectrum, however, new reference points must be established. As a precursor to the intercomparison an additional experiment (IER-147) was proposed with the aim of measuring these reference values for the current Godiva-IV radiation field in the DAF. To establish the reference values Godiva was run in both a sub-critical steady-state mode and a super prompt-critical, pulsed mode. AWE provided neutron spectrometry capabilities in the form of a ROSPEC and Bonner sphere Spectrometer (BSS) for the steady-state experiment, and a Passive Bonner sphere Spectrometer (PBSS) for the pulsed experiment. Neutron leakage spectrum measurements carried out by AWE have been used to determine reference doses around Godiva which can be used for future NAD inter-comparisons. A good comparison of steady-state and pulsed spectra indicates a strong likelihood of being able to relate the power level of both operational methods of the reactor for future work in other fields. Further work is required to determine the fidelity of the thermal peak and it is the intention of AWE to bring additional thermal information to the unfolding process through the incorporation of supplementary activation foils used in the irradiations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transitions From Stochastic to Point Kinetics Models In Fissile Solutions

Fissile solutions form an integral part of the fuel cycle, being used to store and process both fresh fuel and waste. Fissile solutions are also found within Aqueous Homogeneous Reactors (AHRs) including research reactors such as CRAC and SILENE and also potential future systems which could be used for the production of medical isotopes. In the case of fissile solutions in the fuel cycle, avoiding criticality is a priority but accidents have occurred in which a significant number of fissions occurred. In the case of AHRs, a sustained neutron population and fission rate is desired. In both cases the ability to simulate transients where changes in reactivity cause the neutron population to increase are important. A popular method for the simulation of such transients is the point kinetic method which allows the capture of the major features of a transient at a fraction of the computational runtime and code complexity of more comprehensive modelling technologies. A limitation of the point kinetics method and other mainstream methods of predicting neutron behaviour is that they assume the neutron population is large enough that the mean behaviour will be observed. When the neutron population is low, however, the deviation around the mean behaviour is expected to be relatively large as there is an aleatoric uncertainty arising from the uncertain fate of individual neutrons. Such limitations are of particular importance when the reactivity of a system is rapidly increasing while the neutron population is low, which is often true in accident scenarios involving fissile solutions. This provides the motivation for the coupling of point kinetics and a probabilistic models of fissile solutions. This summary aims to explore some of the behaviours resulting from a low neutron population and rising reactivity using a coupled probabilistic and point kinetics model of a fissile solution. As the effects of a low neutron population are the primary concern of this summary, the point kinetics and thermal hydraulic models used will be relatively simple but these models should be sufficient to capture the most important behaviours of the system in the first minute or so of a transient. This work is an extension of the work found in [1]. In that work the methodology was applied to fast pulses produced by systems such as Godiva and its results were found to compare favourably to experimental and analytical results, such as the burst wait time, in [2]. This work focuses on the application of this methodology to a fissile solution but the method could be applied to a number of criticality safety or reactor operation scenarios through suitable modification of the point kinetics model and would produce a more accurate prediction of the peak power obtained when a system first becomes critical compared to the use of a standard point kinetics model. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Research on Fast-Doppler-Broadening of neutron cross sections

A Fast-Doppler-Broadening method is developed in this work to broaden Continuous Energy neutron cross-sections for Monte Carlo calculations. Gauss integration algorithm and parallel computing are implemented in this method, which is unprecedented in the history of cross section processing. Compared to the traditional code (NJOY, SIGMA1, etc.), the new Fast-Doppler-Broadening method shows a remarkable speedup with keeping accuracy. The purpose of using Gauss integration is to avoid complex derivation of traditional broadening formula and heavy load of computing complementary error function that slows down the Doppler broadening process. The OpenMP environment is utilized in parallel computing which can take full advantage of modern multi-processor computers. Combination of the two can reduce processing time of main actinides (such as {sup 238}U, {sup 235}U) to an order of magnitude of 1{approx}2 seconds. This new method is fast enough to be applied to Online Doppler broadening. It can be combined or coupled with Monte Carlo transport code to solve temperature dependent problems and neutronics-thermal hydraulics coupled scheme which is a big challenge for the conventional NJOY-MCNP system. Examples are shown to determine the efficiency and relative errors compared with the NJOY results. A Godiva Benchmark is also used in order to test the ACE libraries produced by the new method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial validation of ALFRED: A Monte Carlo code built on Geant4 for TREAT energy deposition

Predicting the energy deposited in the specimen during an experiment in the Transient Reactor Test (TREAT) Facility is a complex problem due to the nature of the transients occurring in the reactor. In addition, the many particles contributing to energy deposition have different behavior in time and space. ALFRED, a new Geant4 based code, is developed to transport and simulate each particle generated in the core. This code is verified against OpenMC (Open Monte Carlo) on the Godiva benchmark and a simple TREAT model. Next, the energy deposition in TREAT is calculated: 181.05 ± 0.01 MeV for the “instantaneous” energy deposition (which accounts for the energy deposited within 1 s after neutron emission) in fuel and 189.90 ± 0.01 MeV for the total energy deposition in fuel. We discuss these results in this paper with previous calculations and experimental evaluations. This work demonstrates ALFRED’s potential as a high-fidelity tool for computing the spatial and temporal energy deposition in TREAT paving the way for a better understanding of the energy coupling factors in TREAT.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Godiva-IV Critical Assembly [Slides]

Objectives: Familiarization of the Godiva-IV assembly; Understand the criticality safety parameters that effect Godiva IV; Understand the differences between subcritical, delayed-critical, and prompt-critical operations; and, Understand the concept of temperature-dependent reactivity feedback.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Prompt Neutron Decay for Delayed Critical Bare and Natural-Uranium-Reflected Metal Spheres of Plutonium and Highly Enriched Uranium

Prompt neutron decay at delayed criticality was measured by Oak Ridge National Laboratory for uranium-reflected highly enriched uranium (HEU) and Pu metal spheres (FLATTOP), for an unreflected Pu metal (4.5% {sup 240}Pu) sphere (JEZEBEL) at Los Alamos National Laboratory (LANL) and for an unreflected HEU metal sphere at Oak Ridge Critical Experiments Facility. The average prompt neutron decay constants from hundreds of Rossi-{alpha} and randomly pulsed neutron measurements with {sup 252}Cf at delayed criticality are as follows: 3.8458 {+-} 0.0016 x 10{sup 5} s{sup -1}, 2.2139 {+-} 0.0022 x 10{sup 5} s{sup -1}, 6.3126 {+-} 0.0100 x 10{sup 5} s{sup -1}, and 1.1061 {+-} 0.0009 x 10{sup 6} s{sup -1}, respectively. These values agree with previous measurements by LANL for FLATTOP, JEZEBEL, and GODIVA I as follows: 3.82 {+-} 0.02 x 10{sup 5} s{sup -1} for a uranium core; 2.14 {+-} 0.05 x 10{sup 5} s{sup -1} and 2.29 x 10{sup 5} s{sup -1} (uncertainty not reported) for a plutonium core; 6.4 {+-} 0.1 x 10{sup 5} s{sup -1}, and 1.1 {+-} 0.1 x 10{sup 6} s{sup -1}, respectively, but have smaller uncertainties because of the larger number of measurements. For the FLATTOP and JEZEBEL assemblies, the measurements agree with calculations. Traditionally, the calculated decay constants for the bare uranium metal sphere GODIVA I and the Oak Ridge Uranium Metal Sphere were higher than experimental by {approx}10%. Other energy-dependent quantities for the bare uranium sphere agree within 1%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Godiva 4 CAAS Shielding Benchmark: Pre CED-3A Overview [Slides]

Thiis presentation shows the character of an integral experiment. It covers the question why Godiva 4? Additionally, this presentation touches on the IER 498 benchmark quantity, activities facilitated by IER 498, proposed CED-2 test matrix, and what happened during the IER 498’s gap year.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

3D spherical functional expansion tallies in Serpent 2 Monte Carlo code

This work extends the application of functional expansion tallies to 3D spherical geometries. The 3D Zernike polynomials are set as an orthonormal polynomials basis for the functional reconstruction. The study describes the construction of the complete set of polynomials, a natural expansion of the spherical harmonics polynomials where 3D Zernike moments can be evaluated as a linear combination of the geometrical moments. The 3D Zernike polynomials formulation and the computational approach implemented in Serpent 2 are presented and tested through the Godiva model from the ICSBEP criticality benchmark test cases. The implementation results are in agreement with a reference solution described in a fine-resolution mesh, enhancing also the performance and memory demand. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status report on multigroup cross section generation code development for high-fidelity deterministic neutronics simulation system.

Under the fast reactor simulation program launched in April 2007, development of an advanced multigroup cross section generation code was initiated in July 2007, in conjunction with the development of the high-fidelity deterministic neutron transport code UNIC. The general objectives are to simplify the existing multi-step schemes and to improve the resolved and unresolved resonance treatments. Based on the review results of current methods and the fact that they have been applied successfully to fast critical experiment analyses and fast reactor designs for last three decades, the methodologies of the ETOE-2/MC{sup 2}-2/SDX code system were selected as the starting set of methodologies for multigroup cross section generation for fast reactor analysis. As the first step for coupling with the UNIC code and use in a parallel computing environment, the MC{sup 2}-2 code was updated by modernizing the memory structure and replacing old data management package subroutines and functions with FORTRAN 90 based routines. Various modifications were also made in the ETOE-2 and MC{sup 2}-2 codes to process the ENDF/B-VII.0 data properly. Using the updated ETOE-2/MC{sup 2}-2 code system, the ENDF/B-VII.0 data was successfully processed for major heavy and intermediate nuclides employed in sodium-cooled fast reactors. Initial verification tests of the MC{sup 2}-2 libraries generated from ENDF/B-VII.0 data were performed by inter-comparison of twenty-one group infinite dilute total cross sections obtained from MC{sup 2}-2, VIM, and NJOY. For almost all nuclides considered, MC{sup 2}-2 cross sections agreed very well with those from VIM and NJOY. Preliminary validation tests of the ENDF/B-VII.0 libraries of MC{sup 2}-2 were also performed using a set of sixteen fast critical benchmark problems. The deterministic results based on MC{sup 2}-2/TWODANT calculations were in good agreement with MCNP solutions within {approx}0.25% {Delta}{rho}, except a few small LANL fast assemblies. Relative to the MCNP solution, the MC{sup 2}-2/TWODANT results overestimated the multiplication factor by 0.22 {approx} 0.35% {Delta}{rho} for these small systems with very hard neutron spectrum. Comparisons of measured and calculated values for the fission reaction rate ratios of Godiva and Jezebel assemblies also showed that the MC{sup 2}-2/TWODANT results agreed well with measurements within 2.7%. From a series of methodology review and ENDF/B-VII.0 data processing, several improvement needs to enhance accuracy were also identified for the ETOE-2/MC{sup 2}-2 code system, including the multigroup slowing-down solution for whole-energy range, proper treatment for anisotropy of inelastic scattering, improved evaluation of inelastic and high-order anisotropic scattering source in RABANL calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Yield and PDV Measurements of the Godiva-IV Critical Assembly

A high dynamic range, scinillator based detector, the MHD-240, was used to measure the gamma and neutron flux of several prompt critical bursts of the Godiva-IV assembly. The measurements provided the alpha and FWHM for several different burst temperatures. Calibrations of the MHD240 gamma and neutron sensitivity along with MCNP based simulation of the Godiva-IV assembly allowed us to also determine the total fission yield of the burst integrated over approximately 5 ms. In addition a Photo Doppler Velocimetry measurement was conducted to determine the surface motion vibrational frequency of Godiva-IV assembly during the bursts. The combined data were collected to be used as input to multi-physics simulation of the Godiva-IV assembly. This is a preliminary report, there is an ongoing effort to update the MCNP simulations used in the analysis and develop a correction for the room return component of the measured signal.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Orsphere: Physics measurements for bare, HEU(93.2)- metal sphere

In the early 1970s Dr. John T. Mihalczo (team leader), J.J. Lynn, and J.R. Taylor performed experiments at the Oak Ridge Critical Experiments Facility (ORCEF) with highly enriched uranium (HEU) metal (called Oak Ridge Alloy or ORALLOY) in an attempt to recreate GODIVA I results with greater accuracy than those performed at Los Alamos National Laboratory in the 1950s (HEU-MET-FAST-001). The purpose of the Oak Ridge ORALLOY Sphere (ORSphere) experiments was to estimate the unreflected and unmoderated critical mass of an idealized sphere of uranium metal corrected to a density, purity, and enrichment such that it could be compared with the GODIVA I experiments. “The very accurate description of this sphere, as assembled, establishes it as an ideal benchmark for calculational methods and cross-section data files” (Reference 1). While performing the ORSphere experiments care was taken to accurately document component dimensions (±0.0001 inches), masses (±0.01 g), and material data. The experiment was also set up to minimize the amount of structural material in the sphere proximity. Two, correlated spheres were evaluated and judged to be acceptable as criticality benchmark experiments. This evaluation is given in HEU-MET-FAST-100. The second, smaller sphere was used for additional reactor physics measurements. Worth measurements (Reference 1, 2, 3 and 4), the delayed neutron fraction (Reference 3, 4 and 5) and surface material worth coefficient (Reference 1 and 2) are all measured and judged to be acceptable as benchmark data. The prompt neutron decay (Reference 6), relative fission density (Reference 7) and relative neutron importance (Reference 7) were measured, but are not evaluated. Information for the evaluation was compiled from References 1 through 7, the experimental logbooks 8 and 9 ; additional drawings and notes provided by the experimenter; and communication with the lead experimenter, John T. Mihalczo.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Orsphere: Physics Measurments For Bare, HEU(93.2)-Metal Sphere

In the early 1970s Dr. John T. Mihalczo (team leader), J.J. Lynn, and J.R. Taylor performed experiments at the Oak Ridge Critical Experiments Facility (ORCEF) with highly enriched uranium (HEU) metal (called Oak Ridge Alloy or ORALLOY) in an attempt to recreate GODIVA I results with greater accuracy than those performed at Los Alamos National Laboratory in the 1950s (HEU-MET-FAST-001). The purpose of the Oak Ridge ORALLOY Sphere (ORSphere) experiments was to estimate the unreflected and unmoderated critical mass of an idealized sphere of uranium metal corrected to a density, purity, and enrichment such that it could be compared with the GODIVA I experiments. “The very accurate description of this sphere, as assembled, establishes it as an ideal benchmark for calculational methods and cross-section data files” (Reference 1). While performing the ORSphere experiments care was taken to accurately document component dimensions (±0.0001 inches), masses (±0.01 g), and material data. The experiment was also set up to minimize the amount of structural material in the sphere proximity. Two, correlated spheres were evaluated and judged to be acceptable as criticality benchmark experiments. This evaluation is given in HEU-MET-FAST-100. The second, smaller sphere was used for additional reactor physics measurements. Worth measurements (Reference 1, 2, 3 and 4), the delayed neutron fraction (Reference 3, 4 and 5) and surface material worth coefficient (Reference 1 and 2) are all measured and judged to be acceptable as benchmark data. The prompt neutron decay (Reference 6), relative fission density (Reference 7) and relative neutron importance (Reference 7) were measured, but are not evaluated. Information for the evaluation was compiled from References 1 through 7, the experimental logbooks 8 and 9 ; additional drawings and notes provided by the experimenter; and communication with the lead experimenter, John T. Mihalczo.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

National criticality experiments research center: Status and update - 14575

Four critical assembly machines (Comet, Planet, Flat-Top, and Godiva-IV) constitute the critical experiment capabilities at the National Criticality Experiments Research Center. All four machines are operational. Between these machines, systems ranging from the thermal through the intermediate to the fast spectrum may be assembled. Steady-State, transient, and super-prompt critical conditions may be explored. In this paper, the status and capabilities of NCERC are discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗