Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GDL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

70 records · Page 4

Durability of Polymer Electrolyte Membrane Fuel Cells Operated at Subfreezing Temperatures

The structure, composition, and interfaces of membrane electrode assemblies (MEA) and gas-diffusion layers (GDLs) have a significant effect on the performance of single-proton-exchange-membrane (PEM) fuel cells operated isothermally at subfreezing temperatures. During isothermal constant-current operation at subfreezing temperatures, water forming at the cathode initially hydrates the membrane, then forms ice in the catalyst layer and/or GDL. This ice formation results in a gradual decay in voltage. High-frequency resistance initially decreases due to an increase in membrane water content and then increases over time as the contact resistance increases. The water/ice holding capacity of a fuel cell decreases with decreasing subfreezing temperature (-10°C vs. -20°C vs. -30°C) and increasing current density (0.02 A cm -2 vs. 0.04 A cm -2 ). Ice formation monitored using in-situ high-resolution neutron radiography indicated that the ice was concentrated near the cathode catalyst layer at low operating temperatures (≈-20°C) and high current densities (0.04 A cm -2 ). Significant ice formation was also observed in the GDLs at higher subfreezing temperatures (≈-10°C) and lower current densities (0.02 A cm -2 ). These results are in good agreement with the long-term durability observations that show more severe degradation at lower temperatures (-20°C and -30°C).

30 DIRECT ENERGY CONVERSION↗

Reduction in Fabrication Costs of Gas Diffusion Layers

Ballard Material Products (BMP) performed a pre-design technical and cost analysis of state of the art production technologies feasible for high volume GDL manufacturing. Based upon criteria that also included environmental health and safety, customer quality requirements, and future needs, BMP selected technologies that can be integrated into its current manufacturing process. These selections included Many-At-A-Time (MAAT) coating and continuous mixing technologies, as well as various on-line process control tools. These processes have allowed BMP to produce high performance GDLs at lower cost for near-term markets, as well as to define the inputs needed to develop a conceptual Greenfield facility to meet the cost targets for automotive volumes of 500,000 vehicles per year.

08 HYDROGEN↗

WaterTransport in PEM Fuel Cells: Advanced Modeling, Material Selection, Testing and Design Optimization

Water management in Proton Exchange Membrane, PEM, Fuel Cells is challenging because of the inherent conflicts between the requirements for efficient low and high power operation. Particularly at low powers, adequate water must be supplied to sufficiently humidify the membrane or protons will not move through it adequately and resistance losses will decrease the cell efficiency. At high power density operation, more water is produced at the cathode than is necessary for membrane hydration. This excess water must be removed effectively or it will accumulate in the Gas Diffusion Layers, GDLs, between the gas channels and catalysts, blocking diffusion paths for reactants to reach the catalysts and potentially flooding the electrode. As power density of the cells is increased, the challenges arising from water management are expected to become more difficult to overcome simply due to the increased rate of liquid water generation relative to fuel cell volume. Thus, effectively addressing water management based issues is a key challenge in successful application of PEMFC systems. In this project, CFDRC and our partners used a combination of experimental characterization, controlled experimental studies of important processes governing how water moves through the fuel cell materials, and detailed models and simulations to improve understanding of water management in operating hydrogen PEM fuel cells. The characterization studies provided key data that is used as inputs to all state-of-the-art models for commercially important GDL materials. Experimental studies and microscopic scale models of how water moves through the GDLs showed that the water follows preferential paths, not branching like a river, as it moves toward the surface of the material. Experimental studies and detailed models of water and airflow in fuel cells channels demonstrated that such models can be used as an effective design tool to reduce operating pressure drop in the channels and the associated costs and weight of blowers and pumps to force air and hydrogen gas through the fuel cell. Promising improvements to materials structure and surface treatments that can potentially aid in managing the distribution and removal of liquid water were developed; and improved steady-state and freeze-thaw performance was demonstrated for a fuel cell stack under the self-humidified operating conditions that are promising for stationary power generation with reduced operating costs.

30 DIRECT ENERGY CONVERSION↗

488-1D Ash Basin closure cap help modeling- Microdrain® liner option

At the request of Area Completion Engineering and in support of the 488-1D Ash Basin closure, the Savannah River National Laboratory (SRNL) performed hydrologic simulations of the revised 488-1D Ash Basin closure cap design using the Hydrologic Evaluation of Landfill Performance (HELP) model. The revised design substitutes a MicroDrain Liner®—60-mil low-density polyethylene geomembrane structurally integrated with 130-mil drainage layer—for the previously planned drainage/barrier system—300-mil geosynthetic drainage layer (GDL), 300-mil geosynthetic clay liner (GCL), and 6-inch common fill soil layer. For a 25-year, 24-hour storm event, HELP model v3.07 was employed to (1) predict the peak maximum daily hydraulic head for the geomembrane layer, and (2) ensure that South Carolina Department of Health and Environmental Control (SCDHEC) requirements for the barrier layer (i.e., ≤ 12 inches hydraulic head on top of a barrier having a saturated hydraulic conductivity ≤ 1.0E-05 cm/s) will not be exceeded. A 25-year, 24-hour storm event at the Savannah River Site (SRS) is 6.1 inches rainfall (Weber 1998). HELP model v3.07 results based upon the new planned cap design suggest that the peak maximum daily hydraulic head on the geomembrane barrier layer will be 0.15 inches for a minimum slope equal to 3%, which is two orders of magnitude below the SCDHEC upper limit of 12 inches.

58 GEOSCIENCES↗

488-1D Ash basin closure cap help modeling-Microdrain® liner option

At the request of Area Completion Engineering and in support of the 488-1D Ash Basin closure, the Savannah River National Laboratory (SRNL) performed hydrologic simulations of the revised 488-1D Ash Basin closure cap design using the Hydrologic Evaluation of Landfill Performance (HELP) model. The revised design substitutes a MicroDrain Liner®—50-mil linear low-density polyethylene geomembrane structurally integrated with 130-mil drainage layer—for the previously planned drainage/barrier system—300-mil geosynthetic drainage layer (GDL), 300-mil geosynthetic clay liner (GCL), and 6-inch common fill soil layer. For a 25-year, 24-hour storm event, HELP model v3.07 was employed to (1) predict the peak maximum daily hydraulic head for the geomembrane layer, and (2) ensure that South Carolina Department of Health and Environmental Control (SCDHEC) requirements for the barrier layer (i.e., ≤ 12 inches hydraulic head on top of a barrier having a saturated hydraulic conductivity ≤ 1.0E-05 cm/s) will not be exceeded. A 25-year, 24-hour storm event at the Savannah River Site (SRS) is 6.1 inches rainfall (Weber 1998). HELP model v3.07 results based upon the new planned cap design suggest that the peak maximum daily hydraulic head on the geomembrane barrier layer will be 0.179 inches for a minimum slope equal to 3%, which is approximately two orders of magnitude below the SCDHEC upper limit of 12 inches.

54 ENVIRONMENTAL SCIENCES↗

Electrodeposition of Nanostructured Copper on Gas Diffusion Layers as Electrocatalysts for Carbon Dioxide Reduction

The aim of the summer project was to immobilize copper nanostructures on gas diffusion layers to serve as electrocatalysts for the electrochemical reduction of CO 2 . Gas diffusion layers are typically bilayer structures consisting of a macro-porous backing material (carbon fiber paper) and a microporous, carbon-based layer (MPL). Classically, the copper catalysts are loaded on the microporous layer. Furthermore, the GDL is intrinsically hydrophobic due to polytetrafluoroethylene (PTFE)in its chemical composition, with the MPL having a more hydrophobic character due to its higher PTFE content. While beneficial for rendering the MPL impervious to electrolytes during actual CO 2 reduction, the hydrophobicity precludes sufficient wetting of the MPL layer, preventing conformal, uniformly distributed and strongly adhered deposits. A two electrode electrodeposition system was used to facilitate copper deposition. An implication of this system is the inability to ascertain or accurately modulate the cathodic over-potential. Hence, galvanostatic (current control) procedures are utilized for all deposition. To improve the wetting behavior of the MPL, the surface is subjected to surface pretreatment protocols prior to electrodeposition. In addition, as morphology of deposits play a role in their efficacy as catalysts in terms of selectivity and conversion, we systematically investigate the effects of different galvanostatic deposition procedures on copper morphology.

36 MATERIALS SCIENCE↗

Integrated Solutions for Optimized Performance (ISOP) Final Technical Report

The goal of this project was to demonstrate technical feasibility of an integrated approach for deep energy retrofits by packaging innovative technologies with smart communicating controls that represent the next generation of energy efficiency. The integrated solutions for optimized performance (ISOP) package integrates (i) advanced lighting and plug load controls; (ii) intelligent daylight harvesting through automated self-powered shades and window films; (iii) advanced HVAC controls sequences (ASHRAE Guideline (GDL) 36); and (iv) fault detection and diagnosis (FDD) and continuous commissioning (CCx) using advanced analytics. These technologies address energy use across multiple building end uses that represent more than 60% of the energy consumption in all commercial buildings. The project was structured to be implemented over three budget periods: Budget Period 1 scope included site selection, project design, site-specific customization of technology packages, procurement of technologies, initiation of installation of technologies, the development of a measurement and verification plan and collection of pre-retrofit data collection. The first year go/no-go decision was based on securing host sites representing 250,000 sq. ft. of occupied operational spaces, savings analysis, technology procurement and initiation of installation. Budget Period 2 planned to complete technology installations and initiate data collection of post-retrofit performance data. The second year go/no-go was to be the completion of technology installations and commissioning, metering and data collecting to support the requirements laid out in site specific M&V plans. Budget Period 3 planned to collect and analyze post-retrofit performance data and provide data and reporting to support energy efficiency rebate programs. After the team completed activities planned for Budget Period 1, the team reached a Go/No-Go Decision Point. At that point, TRC recommended that DOE discontinue the project without prejudice due to challenges with securing demonstration sites to meet the full 250,000 sf of occupied operational spaces and DOE concurred. In Budget Period 1, the TRC team developed criteria to recruit and evaluate potential demonstration host sites. TRC worked with Princeton University, the project demonstration partner, to identify buildings on their campus as potential candidates for the demonstration. Following the selection of demonstration sites, the TRC team customized energy technology packages according to the needs and characteristics of each site. TRC defined technology specifications, identified vendors, and conducted analysis to estimate energy and cost savings potential. The project team then developed schedules for technology procurement processes and scheduled for installation at all selected demonstration sites. The project team worked with Princeton University and DOE to develop an approach to verify energy savings achieved through measurement and verification (M&V) 2.0 methods. Princeton University initiated open bids to procure the necessary materials and installation contractors. Bid results came back higher than estimates due to a couple of factors – lack of familiarity of the bidders with the proposed technologies and lack of local trained installers to execute the installation of these new measures. Due to the higher bids, projects no longer met the internal cost-effectiveness criteria used by Princeton to proceed with procurement of the full suite of technologies as proposed in ISOP. Princeton had already procured parts of the ISOP package as part of a campus-wide initiative for FDD and lighting retrofits, but with the higher costs for other ISOP components, Princeton could no longer commit to the full ISOP package on the selected sites. Based on this, the team reached the Go/No-Go decision point, where they decided not to proceed with the project. Princeton is separately installing portions of the ISOP package where they individually meet Princeton’s payback criteria but on a different schedule than would have been needed for the DOE ISOP project. The team has learned several lessons from project progress in the first budget period. The team will utilize these lessons in future projects, as should any team which proceeds with a project around the ISOP technology. The first lesson is that more information about the proposed sites is required earlier in the process (perhaps even at the proposal stage) in order to have a successful demonstration. Technical details not evident earlier in the process (such as the TLED limitations for ALCS) can derail project execution. The second lesson is that pricing of emerging technologies is highly variable due to lack of familiarity of local installers and distributor with the proposed technologies as well as alternate bids using products they were more familiar with, but that cost more than the ones proposed by TRC. Finally, the last major lesson is that the host site’s internal project criteria is of critical importance. Based on these higher installed costs and lack of an informed installer base for the products proposed for this project, the project does not meet Princeton’s simple payback goals of five years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Establishment of a Vertically Integrated Domestic Manufacturing Process for Production of Substrates Needed for Manufacture of Gas Diffusion Layers

In this project, AvCarb, LLC evaluated the baseline performance metrics of commercial carbon veils and their corresponding Gas Diffusion Layers (GDLs) with the goal of establishing an optimized, vertically integrated production system for wet-laid nonwoven substrates used in gas diffusion media for electrochemical energy storage and conversion devices. Mechanical testing and microstructural characterization were conducted and used to develop a multiscale computational model capable of simulating and predicting the performance of GDLs in fuel cells. Although the project successfully generated foundational transport and modeling data, it was terminated prior to identifying the critical GDL design parameters necessary for full optimization. The program aimed to improve carbon veil fabrication through enhanced fiber dispersion, fiber-fiber adhesion control, and improved web formation, enabling the production of high-quality, uniform substrates. Simulations were intended to guide mixing and solution delivery system design and process conditions, followed by production-scale trials to evaluate fiber dispersion, web uniformity, and mechanical robustness. At full deployment, the proposed production line would have been capable of producing approximately 650,000 m² of carbon veil annually. This capability remains strategically important, as the United States currently lacks a domestic source of wet-laid nonwoven carbon substrates that satisfy the stringent quality requirements for fuel-cell GDLs and electrolyzers representing an ongoing supply-chain vulnerability. Beyond supply-chain benefits, the project established a robust benchmarking dataset for existing commercial carbon veils while advancing next-generation material concepts targeting improved performance and manufacturing consistency.

Olson, Cynthia Lemay↗

Closed-cycle gas dynamic laser design investigation

A conceptual design study was made of a closed cycle gas-dynamic laser to provide definition of the major components in the laser loop. The system potential application is for long range power transmission by way of high power laser beams to provide satellite propulsion energy for orbit changing or station keeping. A parametric cycle optimization was conducted to establish the thermodynamic requirements for the system components. A conceptual design was conducted of the closed cycle system and the individual components to define physical characteristics and establish the system size and weight. Technology confirmation experimental demonstration programs were outlined to develop, evaluate, and demonstrate the technology base needed for this closed cycle GDL system.

Ketch, G. W.↗

Numerical optimization of gasdynamic lasers

A sophisticated numerical optimization procedure has been coupled to a detailed theoretical model of the carbon dioxide gasdynamic laser (GDL) for the purpose of systematically evaluating the performance of these systems. The integrated model was used to predict the performance of a wide variety of combustion-driven gasdynamic lasers and was then used to maximize the theoretical available specific energy of these lasers. Up to six design variables and three nonlinear constraints were used in these optimizations, although the method is not limited to this number. Results are presented to show the performance of typical lasers before and after optimization. Improvements approaching a factor of two in the available specific energy are found, suggesting that numerical optimization techniques are valuable in improving the design of gasdynamic lasers.

Saunders, R. C., III↗

Systems efficiency and specific mass estimates for direct and indirect solar-pumped closed-cycle high-energy lasers in space

Based on expected advances in technology, the maximum system efficiency and minimum specific mass have been calculated for closed-cycle CO and CO2 electric-discharge lasers (EDL's) and a direct solar-pumped laser in space. The efficiency calculations take into account losses from excitation gas heating, ducting frictional and turning losses, and the compressor efficiency. The mass calculations include the power source, radiator, compressor, fluids, ducting, laser channel, optics, and heat exchanger for all of the systems; and in addition the power conditioner for the EDL's and a focusing mirror for the solar-pumped laser. The results show the major component masses in each system, show which is the lightest system, and provide the necessary criteria for solar-pumped lasers to be lighter than the EDL's. Finally, the masses are compared with results from other studies for a closed-cycle CO2 gasdynamic laser (GDL) and the proposed microwave satellite solar power station (SSPS).

Monson, D. J.↗

Enhanced Water Management of Polymer Electrolyte Fuel Cells with Additive-Containing Microporous Layers

This work describes the performance improvement of a polymer electrolyte fuel cell with a novel class of microporous layers (MPLs) that incorporates hydrophilic additives: one with 30 μm aluminosilicate fibers and another with multiwalled carbon nanotubes with a domain size of 5 μm. Higher current densities at low potentials were observed for cells with the additive-containing MPLs compared to a baseline cell with a conventional MPL, which correlate with improvements in water management. This is also observed for helium and oxygen experiments and by the lower amount of liquid water in the cell, as determined by neutron radiography. Furthermore, carbon-nanotube-containing MPLs demonstrates improved durability compared to the baseline MPL. Microstructural analyses including nanotomography demonstrate that the filler material in both the additive-containing MPLs provide preferential transport pathways for liquid water, which correlate with ex situ measurements. In conclusion, the main advantage provided by these MPLs is improved liquid-water removal from the cathode catalyst layer, resulting in enhanced oxygen delivery to the electrocatalyst sites.

25 ENERGY STORAGE↗

High Performance Gas Diffusion Layer (Phase I Final Report)

Hydrogen fuel cells are of interest for automotive applications because they produce zero emissions. However, fuel cells currently suffer from the high cost associated with the fuel cell stack. Power is limited by water management in the cathode. In this project, pH Matter, LLC synthesized and demonstrated the performance of next generation fuel cell Gas Diffusion Layers (GDLs). The materials out-performed current GDLs in terms of power density and cost per power. The materials were shown to meet the application requirements for key properties. At the commercial scale, these materials will be less expensive than GDLs currently used in hydrogen fuel cells, and enable higher power density, thus reducing fuel cell stack costs. Fuel cell system applications that will benefit most from the technology include automotive, materials handling (i.e. forklifts), fleet vehicles, and stationary back-up power.

25 ENERGY STORAGE↗

Collaboration on SBIR/TTO Phase II Project for Optical QC Device and Collaboration on SBIR/TTO Phase II-b Project for Advanced Quality Inspection Device Development: Cooperative Research and Development CRADA Number CRD-16-00652 (Final Report)

The overall goal of this program is to develop and commercialize a turnkey quality control solution for the entire PEM fuel cell manufacturing process including membrane, gas diffusion layers, catalyst, and assembled systems. This quality control solution is unique to each customer’s specific needs but includes a suite of in-line quality control systems for roll-to-roll manufacturing that can target thin, transparent membrane as well as opaque membrane, catalyst, and GDLs. The Phase II developed the CPNUVV system for thin, transparent membrane that operates using polarized filters to enhance defect resolution and determine thickness. However, PEM material manufacturers want a complete, turnkey solution for all components of the PEM fuel cell. In the Phase IIB, Mainstream will partner with NREL, and transition reflectance technology NREL developed (US Patent 9,234,843) to operate in real-time on a web-line to develop a total solution to PEM quality control. The device will identify and mark defects as well as monitor materials thickness in real-time to improve line efficiency and to reduce waste. The research performed at NREL under this CRADA increases the basis of knowledge about optical inspection methods, how they perform with regards to fuel cell component materials, and how they can be implemented in in-line, real-time configurations to provide quality inspection for roll-to-roll (R2R) manufacturing. Methods explored were found to be sensitive to catalyst loading in electrodes on both membrane and gas diffusion media substrates and to membrane thickness, across a broad range of thickness. The latter capability is novel and now patented and provides a previously unstudied and undemonstrated capability for R2R manufacturing of membranes.

30 DIRECT ENERGY CONVERSION↗

Hydrogen Infrastructure Modeling and Optimization

HyET, established in 2008, is a small business developing electro-chemical hydrogen compressors. HyET’s goals are for a low-cost, efficient, high-pressure compressor ready for market and installation into hydrogen infrastructure stations servicing mobile fuel cell applications. NLR has been working on hydrogen infrastructure research for over a decade and includes electrolyzer production via electrolysis, storage, compression, dispensing, safety, and performance validation. Accelerating technologies into the marketplace is one goal of NLR’s hydrogen research. Therefore, HyET and NLR have teamed up to provide one year of support for HyET’s modeling and small-scale experiments optimization efforts for HyET’s next-generation electro-chemical compressor.

08 HYDROGEN↗