Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Novel Gamma Spectroscopy Method Based on Coincident Measurement of Two Detectors - Paper 98

Spectrum measurement for megavoltage Bremsstrahlung x-rays has been a long-standing challenge. This is because high-energy photons mostly undergo Compton scattering interactions in a detector, and consequently rarely fully deposit their energies in the detector. Most published results of the megavoltage Bremsstrahlung photon spectra were obtained based on reconstruction (or unfolding) from the measured data. These results are unsatisfactory because the process of spectrum unfolding involves the use of the detector's response function which itself often contain large errors. In this experimental study, we developed and tested a new gamma spectrum measurement method that is based on coincident measurement of two detectors. The goal was to eliminate the spectrum unfolding process and thus to be able to obtain the photon spectrum more accurately. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma Spectroscopy of Neutron-Rich Nuclei with CLARA-PRISMA

The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. Results obtained in the vicinity of the doubly-magic nucleus {sup 48}Ca are presented here. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear structure study of {sup 19,21}N nuclei by {gamma} spectroscopy

The structure of neutron-rich nitrogen nuclei has been studied by use of neutron removal reaction and inelastic scattering. Mass and charge deformations have been deduced for the first excited state of {sup 21}N, which indicates the partial persistence of the N=14 subshell closure in nitrogen isotopes. The spectroscopic information obtained on the structure of {sup 19,21}N confirms the results from a previous experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Persistent decoupling of valence neutrons toward the dripline: Study of {sup 20}C by {gamma} spectroscopy

The very neutron-rich nucleus {sup 20}C has been investigated by inelastic scattering on {sup 208}Pb and liquid hydrogen targets. Through distorted wave analysis, the reduced electric quadrupole transition probability B(E2;0{sub g.s.}{sup +}{yields}2{sub 1}{sup +})<18.4 (stat) e{sup 2} fm{sup 4} and the neutron transition probability M{sub n}{sup 2}=292{+-}52 (stat) fm{sup 4} have been derived. A simple shell model calculation has shown a need for a factor of about 0.4 decrease of the normal polarization charges to elucidate the results. This is interpreted as a decoupling of the valence neutrons from the nuclear core in carbon isotopes heavier than {sup 14}C.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development, feasibility, and uncertainty of radioactive 22 Na tracer dilution and gamma spectroscopy for mass determination of molten salt for pyroprocessing spent nuclear fuels

Accurate knowledge of the total mass of molten salts both for pyroprocessing spent nuclear fuels and for molten salt reactors is necessary for safeguards purposes. However, it is challenging to know or measure the total mass of molten salt due to the complicated shapes as well as the compositional—and thus density—changes that occur over time during operation. Here, we investigated radioactive tracer dilution (RTD) as a potential safeguards technique for application to the total mass measurement of LiCl–KCl–UCl 3 salt used for uranium electrorefining, with a focus on the feasibility, uncertainty, and fission product effect of RTD for salt mass measurement. To this end, experimental-scale RTD tests (600–700 g of total mass) were initially carried out by adding 22 Na tracer salt into LiCl–KCl salt containing 0, 5, and 28wt% radioactive salts from an electrorefiner (ER) for refining uranium. Upon the completion of the experimental-scale RTD tests, we performed a scale-up RTD test by directly adding 22 Na tracer salts to the ER, which uses about 12 kg of LiCl–KCl–UCl 3 salt during normal operation. This paper reports the main features of RTD for total mass measurement of molten salt and summarizes the results of the experimental-scale and scale-up RTD tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Induced Radioactivity Analysis for the NSRL Linac in China Using Monte Carlo Simulations and Gamma Spectroscopy - Paper 141

The Synchrotron Radiation Facility of the National Synchrotron Radiation Laboratory (NSRL) located in Hefei, China consists of a 200-MeV electron linear accelerator and an 800-MeV electronic storage ring. Constructed in 1989, the 200-MeV Electron linac is one of the earliest high-energy electron linear accelerators in China. The NSRL is a large-scale experiment device, having been operated more than twenty years, so it is hard to give a historical recount about the injection of NSRL Linac. Lower-energy electrons emitted from the accelerator electron gun are progressively accelerated to about 200 MeV in five acceleration tubes, and then are injected into the electron storage ring, reaching the final energy of 800 MeV. The linear accelerator is a traveling wave linear accelerator, consisting of pre-injection, four 6-m acceleration segment, some beam sensing elements, and focusing inserts. The electrons are accelerated in the acceleration tubes to 32 MeV, 74 MeV, 116 MeV, 158 MeV, respectively, and the electronic energy reaches 200 MeV at the end of the acceleration trip. A scraper is used for beam collimation and is located at the end of each acceleration tube, with a length that increases with the energy to provide sufficient collimation. The NSRL Linac was retired in 2012 due to a plan to upgrade the facility. The decommissioning produced many real challenges related to the methods to handle the large size of the device and the time required to store structural materials until the radioactivity is reduced in the waste repository. These problems should be solved as soon as possible in order for the upgrade to proceed smoothly. At present, no prior decommissioning experience existed in China on such a high-energy electron linear accelerator. Therefore, the decommission project provided an opportunity to study and evaluate the challenges, in particular, involving the induced radioactivity for the purposes of radiation protection. For a well-shielded accelerator facility, the induced radioactivity is an important source of radiation for people who perform the decommissioning. In addition, information on the level of induced radioactivity is needed for disposing of the retired accelerator materials. Therefore it is significant to predict such radioactivity level accurately. However, the induced radioactivity study for such type high-energy electron linear accelerator is very seldom. Particle accelerators that operate at energy greater than 10 MeV will produce induced radioactivity due to well-known photonuclear interactions. However, the assessment of such as induced radioactivity of large-scale installations is a time-consuming process. Experimental methods are time-consuming and require special radiation safety measures to protection the investigators. On the other hand, empirical formula cannot yield sufficiently accurate results. Therefore, Monte Carlo simulation method is the primary means to study such problems. In the decommissioning process of the NSRL Linac, the induced radioactivity assessment will be based on Monte Carlo simulation method as the main auxiliary means to expand a series of studies. (authors)

43 PARTICLE ACCELERATORS↗

Environmental Characterization Scans Using Sodium-Iodide Gamma Spectroscopy to Determine Ra-226 Concentration in Surface Soil - 16326

The recent natural gas drilling boom has brought heightened attention to the issue of TENORM waste management. Radioactive residues from the extraction, treatment, and purification of materials containing uranium and thorium, or their progeny, pose a public health hazard primarily in the form of ground water contamination. Hydraulic fracturing can liberate formation waters from shale; the high salinity of which can cause radium to move with the water to the surface. The disposal and handling of this water has been a subject of public controversy. For soil remediation projects, radium-226 is generally one of the radionuclides of concern due to its alpha emissions. However performing a survey scan for Ra-226 is difficult because its photon emissions are low energy and have minimal probability of emission per decay (186.2 keV, 3.3% abundance). Additionally resolving its emission from U-235 (185.7 keV, 57% abundance) with field instrumentation is not feasible. Therefore detection of Ra-226 relies on the presence and photon emissions of its progeny. This paper outlines methodology for calculating the minimum detectable concentration of Ra-226 in characterization scans using a sodium-iodide detector array coupled with a multi-channel analyzer. Using progeny ingrowth as a detection proxy requires knowing decay time in order to determine progeny emission rates. Knowledge of site history, process, and prior survey results can be key in determining an accurate decay time. However in the absence of such information in-situ measurements can be used to estimate decay time by comparing observed progeny emission ratios against established values. These values are determined using Oak Ridge National Laboratory's ORIGEN-ARP program to generate photon energy spectra for Ra-226 and its progeny at specified time intervals. Once decay time is established, the detector's minimum detectable concentration can be calculated by synthesizing the expected emission spectra and Los Alamos National Laboratory's Monte Carlo N-Particle transport code to simulate detector response. Traditionally, one of the steps in calculating a system's minimum detectable concentration is to place an appropriate button source under the detector, record the response, and then move the source by a specified increment. This process is repeated until the detector's spatial efficiency has been mapped. Due to the impracticality of performing this with Ra-226 button sources of varying decay times, Monte Carlo N-Particle transport code was utilized to determine the detector's spatial efficiency. A dime sized source with the established emission spectra was placed into the center of a rectangle of soil. This rectangle, including the source, was used as a lattice element to fill the region of space below the detector. The simulation was designed to track the energy distribution of pulses created in the sodium iodide crystal using the F8 tally, and was setup to isolate each source; thereby correlating detector response to source position. The simulation output required post-processing to determine conversion factors from counts per second to disintegrations per second. Post-processing accounted for subtraction of the Compton continuum, and average the data over the scanning pattern to obtain the expected spatial sensitivity during a characterization study. This was performed for the following photo-peaks: 609 keV (Bi-214), and 1764 keV (Bi-214). For calculation of the scan minimum detectable concentration, the surveyor efficiency coefficient from NUREG 1507 was supplanted in favor of a scan speed deviation factor. This was used because the detector utilizes computerized data collection (spatial and spectral). This report finds that, for two shielded 10.16 cm x 10.16 cm x 40.64 cm sodium-iodide crystals with integrated multi-channel analyzers, the minimum detectable concentration in surface soils is less than 1 pCi per gram Ra-226 for a 1 second survey measurement. These results assume a volumetric source with a maximum depth of 15.24 cm and a minimum decay time of 21 days. Verification of the system's capabilities was performed by sending soil samples from scanned areas, and locations where in-situ measurements were performed, to an independent laboratory for analysis. The laboratory results demonstrated that scanned area was principally comprised of soil containing less than 1 pCi per gram Ra-226. This borders the system MDC and it underestimated the concentration of radium in the soil. The probable causes of this is escape of radon gas from the surface soil. Radon is the daughter of radium, and has a high mobility in soil. If the gas escapes, then the progeny used as the detection proxy will be present in lower than expected concentrations. Radionuclide identification using high volume sodium-iodide crystals in low level characterization scans is demonstrated to be possible. Further system refinement will focus on developing a methodology to estimate a radon escape factor for site specific use. Accounting for radon escape in the top 15.24 cm of soil will allow the system to better estimate Ra-226 concentrations in soil. This is a significant advancement over the gross counting statistics used in most studies to satisfy MARSSIM survey requirements, because it will increase stakeholder confidence. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contrastive Machine Learning with Gamma Spectroscopy Data Augmentations for Detecting Shielded Radiological Material Transfers

Data analysis techniques can be powerful tools for rapidly analyzing data and extracting information that can be used in a latent space for categorizing observations between classes of data. Machine learning models that exploit learned data relationships can address a variety of nuclear nonproliferation challenges like the detection and tracking of shielded radiological material transfers. The high resource cost of manually labeling radiation spectra is a hindrance to the rapid analysis of data collected from persistent monitoring and to the adoption of supervised machine learning methods that require large volumes of curated training data. Instead, contrastive self-supervised learning on unlabeled spectra can enhance models that are built on limited labeled radiation datasets. This work demonstrates that contrastive machine learning is an effective technique for leveraging unlabeled data in detecting and characterizing nuclear material transfers demonstrated on radiation measurements collected at an Oak Ridge National Laboratory testbed, where sodium iodide detectors measure gamma radiation emitted by material transfers between the High Flux Isotope Reactor and the Radiochemical Engineering Development Center. Label-invariant data augmentations tailored for gamma radiation detection physics are used on unlabeled spectra to contrastively train an encoder, learning a complex, embedded state space with self-supervision. A linear classifier is then trained on a limited set of labeled data to distinguish transfer spectra between byproducts and tracked nuclear material using representations from the contrastively trained encoder. The optimized hyperparameter model achieves a balanced accuracy score of 80.30%. Any given model—that is, a trained encoder and classifier—shows preferential treatment for specific subclasses of transfer types. Regardless of the classifier complexity, a supervised classifier using contrastively trained representations achieves higher accuracy than using spectra when trained and tested on limited labeled data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Europium concentration effects on the scintillation properties of Cs 4 SrI 6 :Eu and Cs 4 CaI 6 :Eu single crystals for use in gamma spectroscopy

Recently discovered scintillators Cs 4 SrI 6 :Eu and Cs 4 CaI 6 :Eu have shown promising properties for gamma-ray detection in homeland security applications, with <4% energy resolution (at 662 keV) and light yields above 50,000 ph/MeV. However, a thorough investigation of the effects of europium concentration has not yet been conducted. In this work, Eu 2+ concentration was varied from 0.5 mol% to 9 mol%, and Ø7 mm single crystals were grown from the melt via the vertical Bridgman method. Scintillation performance was evaluated as a function of Eu 2+ concentration to determine the optimal amount. The observed trend was improved energy resolution and higher light yield with increasing Eu 2+ concentration up to 7 mol%. The best energy resolution achieved was 3.2% for Cs 4 SrI 6 :Eu 7% and 3.6% for Cs 4 CaI 6 :Eu 7%. Their respective light yields were 71,000 ph/MeV and 69,000 ph/MeV.

36 MATERIALS SCIENCE↗

Progress Towards Microcalorimeter Gamma Spectroscopy Analysis for Nuclear Fuel Separations

The High Efficiency and Resolution Microcalorimeter Spectrometer, 400 pixels (HERMES-400) is an ultra-high resolution gamma-ray spectrometer at Idaho National Laboratory’s Materials and Fuels Complex. HERMES-400 is intended to enable precise nondestructive analysis of advanced fuel cycle materials. Key upgrades and repairs of the instrument were performed this year to improve performance. First, the fourth and final microcalorimeter detector module was installed, meeting the milestone for its integration into the system. Operation with all four modules enables higher detector efficiency than any previous microcalorimeter gamma-ray system. Second, a thinner magnetic shield was installed. This shields the sensitive microcalorimeter pixels from stray magnetic fields while allowing transmission of lower-energy gamma rays, which are important to isotopic analysis. Finally, the cryostat, which provides cooling of the modules to their operating temperature, was found to have a helium coolant leak, which was repaired. HERMES-400 is in a stable state to perform repeated, long-term gamma-ray measurements with good detector efficiency and energy resolution. In FY25, irradiated TRISO fuel and salts from advanced electrochemical recycling techniques are candidates for microcalorimeter measurements. A final upgrade of the magnetic shielding and vibration damping of the system is also planned to maximize the system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved plutonium and americium photon branching ratios from microcalorimeter gamma spectroscopy

Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution - (60–70 eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium ( 238 Pu, 239 Pu, 241 Pu) and 241 Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. Lastly, we show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2–3 for four branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Energy Delayed Gamma Spectroscopy for Plutonium Assay of Spent Fuel

The direct measurement of plutonium in spent reactor fuel is an unmet challenge in international safeguards. In this simulation study, we investigate the use of the delayed gamma rays from fission product nuclei to determine the amount of fissile isotopes (Pu-239, Pu-241, and U-235) in irradiated light water reactor fuel assemblies. Fission is stimulated with an interrogating neutron source, and the radiation from the short lived fission products is measured. This measured gamma spectrum is then fit to a linear combination of spectra from pure Pu-239, Pu-241, and U-235 to determine the proportion of fissile isotopes present. In this paper, we describe the modelling and analysis methods used to represent the background of radioemissions from long-lived isotopes originally present in the spent fuel and the short time scale delayed gamma signal. Results are presented for simulations using a nominal instrument design on a library of fuel assemblies with burnups ranging from 0 to 60 GWd/MTU.

Campbell, Luke W.↗

Full Rod Length Gamma Spectroscopy Measurements of LWR Used Fuel Rods

Twenty-five high-burnup pressurized water reactor used fuel rods were scanned in the Irradiated Fuels Examination Laboratory at Oak Ridge National Laboratory with a high-resolution gamma spectrometer. A planar high-purity germanium detector was used across an energy range from 60 keV to 3 MeV. Gamma spectra of individual fuel rods were collected in 4.5 mm steps along the entire length of each rod. Additional spectra were collected on select rods in rotational increments of 30 degrees to provide data on the distribution of fission products along the rod perimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Brief Introduction to Gamma Spectroscopy [Slides]

Radiation energy is measured in units of electron volts (eV). Photon energies are like a fingerprint that allow us to identify specific radioisotopes. Radiation interacts with our detector & deposits energy. That deposited energy produces a proportional signal. Signals are sorted and analyzed. Signals are placed in a histogram, making a gamma spectrum. Analyze gamma spectrum and identify the radioactive material.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Guide for Employing High-Resolution Gamma Spectroscopy for 252Cf Source Age and Isotopic Composition

Californium-252 is commonly used as a calibration source for neutron coincidence and neutron multiplicity counting in nuclear safeguards. Accurate knowledge of the neutron emission rate, age, and isotopics of the source (i.e., “source term”) are important for ensuring the best possible accuracies in item assay results. Californium-252 sources are not usually measured using gamma spectrometry, because of the assumption that their gamma-ray spectra appear to provide little information. However, gamma-ray signatures produced from 252Cf spontaneous fission products and odd-numbered Cf isotopes can be useful in determining source age and Cf isotopic composition. We demonstrate the utility of high-resolution gamma spectrometry in determining the age and isotopics of Cf neutron sources. In this work, five 252Cf sources were measured using a high-purity germanium detector. The neutron flux was small enough that radiation damage from prolonged neutron exposure was not substantial. Spectra were collected in 2-hour increments for 42–48 hours for quality control. The 2-hour spectra were added together to create a single spectrum for each source, and peak analyses were performed. Source ages were determined using a method that involved experimentally measuring the ratio of the gamma-ray emission rate of the 661.657 keV from 137Cs relative to a short-lived fission product and exploiting the dependence of this ratio on the source age. Source age was solved for using emission rates from four different gamma lines from four short-lived spontaneous fission products. Analysis results from all four fission products returned statistically similar source ages, but two had uncertainties greater than 25% because of high spontaneous fission product yield uncertainties as nominally high as 63%. Choosing short-lived fission products with small yield uncertainties is most important for accurately calculating source age. Additionally, the calculated ages did not always match the time since 248Cm separation well, which is often assumed to be the source age on the technical data sheet provided by the manufacturer. Activity ratios of 249Cf to 251Cf, the only Cf gamma emitters present in a 252Cf source, also did not match between experimental data and data on the technical data sheet provided by the vendor. It is thus recommended that newly purchased Cf sources be examined using gamma spectrometry to determine the source age and confirm isotopic composition of a 252Cf calibration source.

Watson, Mara M.↗

Instrument Development and Gamma Spectroscopy with Strontium Iodide

Development of the Europium-doped Strontium Iodide scintillator, SrI2(Eu), involves advances in crystal growth, optics and readout methodology for prototype detectors. We have demonstrated energy resolution of 3% at 662 keV for a 26 cm3 SrI2(Eu) crystal, which is comparable to the performance obtained with Cerium-doped Lanthanum Bromide of equivalent size. Compared to standard analog readout, use of a digital readout method allows improved energy resolution to be obtained with large-volume SrI2(Eu) crystals. Comparative gamma spectra acquired with LaBr3(Ce) and NaI(Tl) quantitatively depict the value of the high resolution and low intrinsic radioactivity of SrI2(Eu) in discriminating closely spaced gamma lines for radioisotope identification applications.

Cherepy, Nerine↗