Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

Towards AI Based Data Classification for Decision Making During Testing

During the development of high-consequence items, test systems should be capable of differentiating between test failures resulting from narrowly missing requirements versus those indicating potentially catastrophic faults. In many instances, classifying the data corresponds to simply identifying whether measured waveforms have approximately the anticipated shape. Cast in this light, the problem reduces to converting raw data into a form optimal for use with neural network classifiers. This manuscript investigates different means of representing raw data for image classification. Raw data plots and Short Time Fourier Transform (STFT) spectrograms are classified by both custom built, small-scale, Convolution Neural Networks (CNN) and open-source, multi-million parameter, pre-trained deep CNNs. In the case of time varying frequency content, the STFTs provide images with greater detail and can be accurately classified with simpler networks. This requires less memory and runs faster than classifying the raw data using the more sophisticated options—making STFTs optimal for applications with memory constraints. STFTs are not a panacea. In some cases the time-domain signal contains useful information that should not be discarded. Rather than using raw data or STFTs, the images can be constructed from both by using red and green channels of an RGB image to visualize the real and imaginary components of the transform, with the raw data occupying the blue channel.

97 MATHEMATICS AND COMPUTING↗

Computational scanning tunneling microscope image database

We introduce the systematic database of scanning tunneling microscope (STM) images obtained using density functional theory (DFT) for two-dimensional (2D) materials, calculated using the Tersoff-Hamann method. It currently contains data for 716 exfoliable 2D materials. Examples of the five possible Bravais lattice types for 2D materials and their Fourier-transforms are discussed. All the computational STM images generated in this work are made available on the JARVIS-STM website ( https://jarvis.nist.gov/jarvisstm ). We find excellent qualitative agreement between the computational and experimental STM images for selected materials. As a first example application of this database, we train a convolution neural network model to identify the Bravais lattice from the STM images. We believe the model can aid high-throughput experimental data analysis. These computational STM images can directly aid the identification of phases, analyzing defects and lattice-distortions in experimental STM images, as well as be incorporated in the autonomous experiment workflows.

47 OTHER INSTRUMENTATION↗

Toward Revealing Microcystin Distribution in Mouse Liver Tissue Using MALDI-MS Imaging

Cyanotoxins can be found in water and air during cyanobacterial harmful algal blooms (cHABs) in lakes and rivers. Therefore, it is very important to monitor their potential uptake by animals and humans as well as their health effects and distribution in affected organs. Herein, the distribution of hepatotoxic peptide microcystin-LR (MC-LR) is investigated in liver tissues of mice gavaged with this most common MC congener. Preliminary matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) imaging experiments performed using a non-automated MALDI matrix deposition device and a MALDI-time-of-flight (TOF) mass spectrometer yielded ambiguous results in terms of MC-LR distribution in liver samples obtained from MC-LR-gavaged mice. The tissue preparation for MALDI-MS imaging was improved by using an automated sprayer for matrix deposition, and liver sections were imaged using an Nd:YAG MALDI laser coupled to a 15 Tesla Fourier-transform ion cyclotron resonance (FT-ICR)-mass spectrometer. MALDI-FT-ICR-MS imaging provided unambiguous detection of protonated MC-LR (calculated m/z 995.5560, z = +1) and the sodium adduct of MC-LR (m/z 1017.5380, z = +1) in liver sections from gavaged mice with great mass accuracy and ultra-high mass resolution. Since both covalently bound and free MC-LR can be found in liver of mice exposed to this toxin, the present results indicate that the distribution of free microcystins in tissue sections from affected organs, such as liver, can be monitored with high-resolution MALDI-MS imaging.

59 BASIC BIOLOGICAL SCIENCES↗

Using coherent dipion photoproduction to image gold nuclei

Vector meson photoproduction offers the opportunity to image target nuclei. The two-dimensional Fourier transform d\sigma_{coherent}/dt d σ c o h e r e n t / d t of coherent vector meson photoproduction gives the two-dimensional distribution of interaction sites in the target. Since vector meson photoproduction occurs, at lowest order, via two-gluon exchange, this is sensitive to gluon shadowing. We present an analysis of \pi^+\pi^- π + π − photoproduction using data from the STAR detector and a study of d\sigma_{coherent}/dt d σ c o h e r e n t / d t , with an emphasis on probing the nuclear shape and its systematic uncertainties.

Klein, Spencer↗

Out of distribution evaluation for neural image compression

Official code for the NeurIPS 2023 paper "Neural Image Compression: Generalization, Robustness, and Spectral Biases". This code can be used to: - Computing spectral distortion errors of images compressed with traditional codes or neural image compression models (as proposed in the aformentioned paper) - Visualize power spectral densities and fourier heatmaps (as proposed in the aformentioned paper) - Train and test a variety of neural image compression models

Lieberman, KelseyA↗

Quantum JPEG

The joint photographic expert group algorithm compresses a digital image by filtering its high spatial-frequency components. Similarly, we introduce a quantum algorithm that uses the quantum Fourier transform to discard the high spatial-frequency qubits of an image, downsampling it to a lower resolution. This allows one to capture, compress, and send images even with limited quantum resources for storage and communication. We show under which conditions this protocol is advantageous with respect to its classical counterpart.

97 MATHEMATICS AND COMPUTING↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗

Study of azimuthal anisotropy of $\Upsilon$ (1S) mesons in pPb collisions at $\sqrt{S_{NN}}$ = 8.16 TeV

The azimuthal anisotropy of Image 1 mesons in high-multiplicity proton-lead collisions is studied using data collected by the CMS experiment at a nucleon-nucleon center-of-mass energy of 8.16 TeV. The Image 1 mesons are reconstructed using their dimuon decay channel. The anisotropy is characterized by the second Fourier harmonic coefficients, found using a two-particle correlation technique, in which the Image 1 mesons are correlated with charged hadrons. A large pseudorapidity gap is used to suppress short-range correlations. Nonflow contamination from the dijet background is removed using a low-multiplicity subtraction method, and the results are presented as a function of Image 1 transverse momentum. The azimuthal anisotropies are smaller than those found for charmonia in proton-lead collisions at the same collision energy, but are consistent with values found for Image 1 mesons in lead-lead interactions at a nucleon-nucleon center-of-mass energy of 5.02 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum Super-resolution Bioimaging using Massively Entangled Multimode Squeezed Light

This report presents a new method for realizing a super-resolution quantum imaging using massively entangled multimode squeezed light (MEMSL). Each branch of the entangled multimode light interacts with the sample and bears the spatially varying optical phase delay. When imaging optics with finite pupil sizes are used, information is lost. Thanks to the analyticity in the Fourier plane, a noiseless measurement would recover the lost information and accomplish super resolution imaging beating the Rayleigh diffraction limit. I proved rigorously in a fully quantum formalism and presented that (1) such information recovery is possible and (2) the information recovery can be accomplished with much less resources when MEMSL is used than those needed in any non-entangled or non-squeezed classical imaging method. Furthermore, the action of the optical loss in the imaging system that degrades the imaging performance is also rigorously analyzed and presented. Several bioimaging applications that can benefit tremendously from the proposed quantum imaging scheme are also suggested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive 3D convolutional neural network-based reconstruction method for 3D coherent diffraction imaging

We present a novel adaptive machine-learning based approach for reconstructing three-dimensional (3D) crystals from coherent diffraction imaging. We represent the crystals using spherical harmonics (SH) and generate the corresponding synthetic diffraction patterns. We utilize 3D convolutional neural networks (CNNs) to learn a mapping between 3D diffraction volumes and the SH, which describe the boundary of the physical volumes from which they were generated. We use the 3D CNN-predicted SH coefficients as the initial guesses, which are then fine-tuned using adaptive model-independent feedback for improved accuracy. We also adaptively tune the locations, intensities, and decay rates of collections of radial basis functions in order to reproduce the non-uniform internal structure of 3D objects and demonstrate the method for a synthetic volume that has an internal void and a density ramp.

36 MATERIALS SCIENCE↗

Computing diffraction patterns of microstructures from phase-field simulations

The diffraction pattern of a material contains information not only on the crystal structures of its constituting phases, but also on its mesoscale spatial distributions of phases, grains, and ferroelastic, ferroelectric, and ferromagnetic domains. While diffraction patterns from experiments such as X-ray diffraction are presented in the reciprocal or Fourier space, mesoscale microstructure models such as the phase-field method naturally produce real-space images of spatial distribution of chemical composition, structural, and ferroic domains. Although one could rather readily compute the Fourier amplitudes of chemical and structural domain distributions generated by mesoscale simulations, they only contain information about the length scale and alignment of the real-space chemical and structure domains. Therefore, a direct comparison between diffraction experiments and mesoscale microstructure simulations is not possible. Here, we develop a theoretical approach to directly compute the crystal diffraction patterns of microstructures predicted by phase-field simulations. In particular, we consider five representative examples of microstructure patterns involving purely compositional domains, a single pair of tetragonal twin structures, multiple twin variants in a hexagonal system, ferroelectric polar vortices, and polycrystalline grains. The results are compared with previous experimental observations as well as X-ray diffraction experiments performed in the present study. Furthermore, the theoretical framework allows one to directly connect material microstructures and diffraction patterns predicted from phase-field simulations and the corresponding diffraction patterns from experiments, and thus providing guidance to experimental diffraction characterization and interpretation of microstructures.

36 MATERIALS SCIENCE↗

Autonomous convergence of STM control parameters using Bayesian optimization

Scanning tunneling microscopy (STM) is a widely used tool for atomic imaging of novel materials and their surface energetics. However, the optimization of the imaging conditions is a tedious process due to the extremely sensitive tip–surface interaction, thus limiting the throughput efficiency. In this paper, we deploy a machine learning (ML)-based framework to achieve optimal atomically resolved imaging conditions in real time. The experimental workflow leverages the Bayesian optimization (BO) method to rapidly improve the image quality, defined by the peak intensity in the Fourier space. The outcome of the BO prediction is incorporated into the microscope controls, i.e., the current setpoint and the tip bias, to dynamically improve the STM scan conditions. We present strategies to either selectively explore or exploit across the parameter space. As a result, suitable policies are developed for autonomous convergence of the control parameters. The ML-based framework serves as a general workflow methodology across a wide range of materials.

97 MATHEMATICS AND COMPUTING↗

Fourier-based three-dimensional multistage transformer for aberration correction in multicellular specimens

High-resolution tissue imaging is often compromised by sample-induced optical aberrations that degrade resolution and contrast. Although wavefront sensor-based adaptive optics (AO) can measure these aberrations, such hardware solutions are typically complex, expensive to implement and slow when serially mapping spatially varying aberrations across large fields of view. Here we introduce AOViFT (adaptive optical vision Fourier transformer)—a machine learning-based aberration sensing framework built around a three-dimensional multistage vision transformer that operates on Fourier domain embeddings. AOViFT infers aberrations and restores diffraction-limited performance in puncta-labeled specimens with substantially reduced computational cost, training time and memory footprint compared to conventional architectures or real-space networks. We validated AOViFT on live gene-edited zebrafish embryos, demonstrating its ability to correct spatially varying aberrations using either a deformable mirror or postacquisition deconvolution. By eliminating the need for the guide star and wavefront sensing hardware and simplifying the experimental workflow, AOViFT lowers technical barriers for high-resolution volumetric microscopy across diverse biological samples.

Alshaabi, Thayer [Howard Hughes Medical Institute,↗

Two-phase accurate multiplexed structured image capture (2pAc-MUSIC)

Multiplexed Structural Image Capture (MUSIC) technique uses modulation of light from a scene prior to imaging to encode the temporal evolution of target into spatial frequency shifts, with each shift corresponding to a unique time and resulting in individual distinct snapshots. Computational-processing of the multiplexed single-shot image can recover the nanosecond-resolution scene evolution. One of the limitations is the loss of spatial resolution of the recovered image due to limitations of the low-pass spatial frequency filtering depth. Here we demonstrated that two images with complementary spatial phases can be used to enhance the spatial resolutions. For this application, 2 Phase Accurate (2pAc)-MUSIC is implemented that a scene is encoded with two complementary phases. The increased spatial information captured reduces the lower frequency noise in the Fourier domain found in single-phase MUSIC. A recovery algorithm combines the 180-degree spatial frequency shifted images into a single scene and applies a spatial filter in the Fourier domain that has a larger depth than previously possible to achieve a scene with increased spatial resolution. The 2pAc-MUSIC can effectively enhance the spatial resolution by removing the overlapping zero-order spatial frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collimated phase measuring deflectometry

Phase measuring deflectometry has been applied for free-form specular surface metrology, but its measured slope results are sensitive to the depth of sample positioning, which is also called the height-slope ambiguity. The objective of this work is to tackle this height-slope ambiguity problem. The main idea is to introduce collimated camera rays using a telecentric imaging lens and collimated structured-light illumination with a Fourier lens. This setup makes the fringe phases become only sensitive to the surface slopes and insensitive to the depth of the sample positioning. In this way, the slope calculation is theoretically independent of the sample depth. We call this new deflectometry technique Collimated Phase Measuring Deflectometry (CPMD). With our developed CPMD experimental setup, the measurement is insensitive to the depth of sample positioning, e.g., the measured height dispersion is less than 30 nm RMS within a 10 mm depth range when measuring a 50-mm-diameter spherical mirror with a 200 mm radius of curvature. In conclusion, the merits and limitations of the proposed CPMD technique are discussed, revealing its prospects in practical metrology applications and potential future investigations.

36 MATERIALS SCIENCE↗

Missing Wedge Completion via Unsupervised Learning with Coordinate Networks

Cryogenic electron tomography (cryoET) is a powerful tool in structural biology, enabling detailed 3D imaging of biological specimens at a resolution of nanometers. Despite its potential, cryoET faces challenges such as the missing wedge problem, which limits reconstruction quality due to incomplete data collection angles. Recently, supervised deep learning methods leveraging convolutional neural networks (CNNs) have considerably addressed this issue; however, their pretraining requirements render them susceptible to inaccuracies and artifacts, particularly when representative training data is scarce. To overcome these limitations, we introduce a proof-of-concept unsupervised learning approach using coordinate networks (CNs) that optimizes network weights directly against input projections. This eliminates the need for pretraining, reducing reconstruction runtime by 3–20× compared to supervised methods. Our in silico results show improved shape completion and reduction of missing wedge artifacts, assessed through several voxel-based image quality metrics in real space and a novel directional Fourier Shell Correlation (FSC) metric. Our study illuminates benefits and considerations of both supervised and unsupervised approaches, guiding the development of improved reconstruction strategies.

42 ENGINEERING↗